Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Kinetic Isotope Effects: Interpretation and Prediction Using Degrees of Rate Control

Kinetic isotope effects (KIEs) have been used for decades in catalysis research as a tool for clarifying reaction mechanisms. Significant primary kinetic isotope effects have usually been interpreted as being a result of isotope substitution at a site of bond breaking (or forming) in the rate-determining step in the reaction mechanism. However, quantitative analysis of the magnitude of the KIE in complex multistep reaction mechanisms is seldom reported. We prove here that the logarithm of the rate ratio for two isotopes is the weighted average over all species in the mechanism of their standard-state free energy difference between the two isotopes, divided by RT. The weighting factor is the degree of rate control (DRC) for that species (e.g., transition state, intermediate, reactant) when the rate is measured separately for each isotope. It is instead the degree of selectivity ratio control (DSRC) when the KIE is measured as the product selectivity in a parallel competition between two isotopes within the same reactant molecule. Since only a few species have non-zero DRCs (or DSRCs) for most reactions, only these few contribute to this weighted average and the KIE. We show that this provides a simple way to interpret and quantitatively predict kinetic isotope effects that is powerful in the insights it provides, allowing one to evaluate directly which species contribute most to the KIE. By applying it to H/D KIEs in several example mechanisms, we further show that the traditional way of interpreting KIEs that focuses only on the rate-determining step can easily lead to misunderstanding of KIE and the reaction mechanism. Finally, this highlights the importance to consider the effect of isotope substitution on the energies of all species with large DRCs (i.e, those whose energies are kinetically relevant). This method also offers opportunities for quantitative validation of mechanism-based microkinetic models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using Carbon Isotope Fractionation to Constrain the Extent of Methane Dissolution Into the Water Column Surrounding a Natural Hydrocarbon Gas Seep in the Northern Gulf of Mexico

A gas bubble seep located in the northern Gulf of Mexico was investigated over several days to determine whether changes in the stable carbon isotopic ratio of methane can be used as a tracer for methane dissolution through the water column. Gas bubble and water samples were collected at the seafloor and throughout the water column for isotopic ratio analysis of methane. Our results show that changes in methane isotopic ratios are consistent with laboratory experiments that measured the isotopic fractionation from methane dissolution. A Rayleigh isotope model was applied to the isotope data to determine the fraction of methane dissolved at each depth. On average, the fraction of methane dissolved surpasses 90% past an altitude of 400 m above the seafloor. Methane dissolution was also investigated using a modified version of the Texas A&M Oil spill (Outfall) Calculator (TAMOC) where changes in methane isotopic ratios could be calculated. The TAMOC model results show that dissolution depends on depth and bubble size, explaining the spread in measured isotopic ratios during our investigations. Both the Rayleigh and TAMOC models show that methane bubbles quickly dissolve following emission from the seafloor. Together, these results show that it is possible to use measurements of natural methane isotopes to constrain the extent of methane dissolution following seafloor emission.

58 GEOSCIENCES↗

New K-feldspar Pb isotope results for Mesozoic arc crust in the Pacific Northwest, U.S.A. and Canada: comparison with the Mojave-Salinia province of southern California and Implications for Baja-BC

Measurements of lead isotopic compositions in detrital K-feldspar have been increasingly used as a tool to assess sediment provenance. We compiled a database of previously published Pb isotope data from 700 bedrock K-feldspar samples and 1,423 age-corrected bedrock whole rock samples from western North American igneous and metamorphic bodies. Additionally, we report 66 new K-feldspar Pb isotope data for plutons throughout the Pacific Northwest region of the United States and British Columbia. Results show that the Pb isotope values of plutonic K-feldspar depend on the isotopically juvenile or evolved nature of underlying crust. Samples obtained from the mid Cretaceous – mid Eocene Coast Plutonic Complex, North Cascades, and Intermontane superterrane that occur west of the initial 87 Sr/ 86 Sr (Sri) = 0.706 isopleth exhibit a highly restricted 207 Pb/ 206 Pb and 208 Pb/ 206 Pb values centred upon 0.83 and 2.03, respectively. Conversely, rocks overlying older continental crust further east such as the Middle Jurassic – Late Cretaceous Omineca crystalline belt, Idaho batholith, and Boulder Batholith exhibit far greater variation of Pb isotope values that parallel the 100 Ma isochron calculated from a two-stage Pb evolution model. We demonstrate that Pb isotopic results from the Idaho and Boulder Batholith region can be used to define distinctive subregions for Pb isotopic provenance analysis, and compare these signatures to the Mojave-Salinian batholith of southern California and western Arizona, as these two areas have previously been proposed as source regions for extraregional sediment that was deposited within the Nanaimo Basin during the Campanian – Maastrichtian. Future Pb isotopic analysis of detrital K-feldspar from the Nanaimo Basin of southwestern British Columbia may effectively distinguish between potential extraregional sources separated by thousands of kilometres.

Coast Plutonic Complex↗

Isotopic Signatures of Lithium Carbonate and Lithium Hydroxide Monohydrate Measured Using Raman Spectroscopy

Lithium isotopic ratios have wide ranging applications as chemical signatures, including improved understanding of geochemical processes and battery development. Measurement of isotope ratios using optical spectroscopies would provide an alternative to traditional mass spectrometric methods, which are expensive and often limited to a chemical laboratory. In this work, Raman spectra of 7 Li 2 CO 3 , 6 Li 2 CO 3 , 7 LiOH*H 2 O and 6 LiOH*H 2 O have been measured to determine the effect of lithium isotope substitution on the Raman molecular vibrations. Thirteen peaks were observed in the spectrum of lithium carbonate, with discernable isotopic shifts occurring in eleven of the thirteen vibrations, two of which have not been previously reported in the literature. The spectrum of lithium hydroxide monohydrate contained nine peaks, with discernable isotopic shifts occurring in eight of the nine vibrations, four of which have not been previously reported in the literature. The Raman spectral data reported here for lithium carbonate and lithium hydroxide monohydrate are in agreement with the previously reported works in the literature, in which the Raman active modes of these molecules were first identified and assigned. However, due to the stability and resolution of the detection system used in this work, isotopic shifts with a magnitude less than one wavenumber have been identified. Principal Component Regression was used to evaluate the sensitivity to isotopic content of small Raman peak shifts in Li 2 CO 3 and indicates differences greater than 2 atom-% could be reliably determined. These measurements add to the body of work on lithium isotope Raman spectroscopy for these two compounds and increases the number of Raman bands which could be used for lithium isotope content analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EBIS/T charge breeding for intense rare isotope beams at MSU

Experiments with reaccelerated beams are an essential component of the science program of existing and future rare isotope beam facilities. NSCL is currently constructing ReA3, a reaccelerator for rare isotopes that have been produced by projectile fragmentation and in-flight fission and that have been thermalized in a gas stopper. The resulting low-energy beam will be brought to an Electron Beam Ion Source/Trap (EBIS/T) in order to obtain highly charged ions at an energy of 12 keV/u. This charge breeder is followed by a compact linear accelerator with a maximum beam energy of 3MeV/u for U-238 and higher energies for lighter isotopes. Next-generation rare isotope beam facilities like the Facility for Rare Isotope Beams FRIB, but also existing Isotope Separator On-line (ISOL) facilities are expected to provide rare-isotope beam rates in the order of 10(11) particles per second for reacceleration. At present the most promising scheme to efficiently start the reacceleration of these intense beams is the use of a next-generation high-current charge-breeder based on an EBIS/T. MSU has formed a collaboration to develop an EBIT for this purpose. A new high-current EBIS/T breeder will be developed and constructed at MSU, where also first tests on achievable beam rate capability will be performed. The EBIT is planned to be installed at the Isotope Separator and Accelerator facility ISAC at TRIUMF laboratory for on-line tests with rare isotope beams and to provide intense energetic reaccelerated radioactive beams. The status of the ReA3-EBIS/T in the NSCL reaccelerator project is given with a brief summary of results, followed by a discussion of plans for the future high-intensity EBIS/T charge breeder.

43 PARTICLE ACCELERATORS↗

Iron Isotopic Compositions of Troilite (FeS) Inclusions from Iron Meteorites

We report non-mass-dependent Fe isotopic data for troilite (FeS) inclusions from 10 iron meteorites, representing both non-magmatic (IAB) and magmatic groups (IIAB, IIIAB, IVA). No resolvable variations are present in the most neutron-rich isotope ({sup 58}Fe), but small deficits (≈−0.1 ε ) in {sup 56}Fe were observed in several inclusions. With the exception of several Ca–Al-rich inclusions in primitive meteorites, these are the first reported non-mass-dependent variations in Fe isotopes for material formed in the early solar system. Nucleosynthetic variations in Ni isotopes were previously reported in these same samples. The effects in Fe isotopes are not correlated with those in Ni, which suggests that the origins of the isotopic variations are decoupled from one another. The {sup 56}Fe deficits may represent incomplete mixing of the precursor dust in the protoplanetary disk. Alternatively, a parent body process (e.g., irradiation by galactic cosmic rays) may have modified the Fe isotopic compositions of some inclusions, which initially had homogeneous Fe isotopic compositions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of Stable Isotopes in Forensic Analysis of Microorganisms

The use of isotopic signatures for forensic analysis of biological materials is well-established, and the same general principles that apply to interpretation of stable isotope content of C, N, O, and H apply to the analysis of microorganisms. Heterotrophic microorganisms derive their isotopic content from their growth substrates, which are largely plant and animal products, and the water in their culture medium. Thus the isotope signatures of microbes are tied to their growth environment. The C, N, O, and H isotope ratios of spores have been demonstrated to constitute highly discriminating signatures for sample matching. They can rule out specific samples of media and/or water as possible production media, and can predict isotope ratio ranges of the culture media and water used to produce a given sample. These applications have been developed and tested through analyses of approximately 250 samples of Bacillus subtilis spores and over 500 samples of culture media, providing a strong statistical basis for data interpretation. A Bayesian statistical framework for integrating stable isotope data with other types of signatures derived from microorganisms has been able to characterize the culture medium used to produce spores of various Bacillus species, leveraging isotopic differences in different medium types and demonstrating the power of data integration for forensic investigations.

59 BASIC BIOLOGICAL SCIENCES↗

Bound and mobile soil water isotope ratios are affected by soil texture and mineralogy, whereas extraction method influences their measurement

Questions persist about interpreting isotope ratios of bound and mobile soil water pools, particularly relative to clay content and extraction conditions. Interactions between pools and resulting extracted water isotope composition are presumably related to soil texture, yet few studies have manipulated the bound pool to understand its influence on soil water processes. Using a series of drying and spiking experiments, we effectively labelled bound and mobile water pools in soils with varying clay content. Soils were first vacuum dried to remove residual water, which was then replaced with heavy isotope-enriched water prior to oven drying and spiking with heavy isotope-depleted water. Water was extracted via centrifugation or cryogenic vacuum distillation (at four temperatures) and analysed for oxygen and hydrogen isotope ratios via isotope ratio mass spectrometry. Water from centrifuged samples fell along a mixing line between the two added waters but was more enriched in heavy isotopes than the depleted label, demonstrating that despite oven drying, a residual pool remains and mixes with the mobile water. Soils with higher clay + silt content appeared to have a larger bound pool. Water from vacuum distillation samples have a significant temperature effect, with high temperature extractions yielding progressively more heavy isotope-enriched values, suggesting that Rayleigh fractionation occurred at low temperatures in the vacuum line. By distinctly labelling bound and mobile soil water pools, we detected interactions between the two that were dependent on soil texture. Although neither extraction method appeared to completely extract the combined bound and mobile (total water) pool, centrifugation and high temperature cryogenic vacuum distillations were comparable for both δ 2 H and δ 18 O of soil water isotope ratios.

54 ENVIRONMENTAL SCIENCES↗

A Comprehensive Review of Selected Major Categories of Lithium Isotope Separation Techniques

The ability to generate materials with an enriched isotopic abundance, that is one that differs from natural abundance, is critical in terms of technology. Isotopes are used in a wide range of applications, including radioactive tracers, nondestructive tests, radiotherapy in human medicine, nuclear fuels, and isotope‐substituted compounds for chemistry and biology research, as well as environmental geochemical signature tracers. A commonly discussed research topic is the isotopic separation of various elements—uranium, hydrogen, lithium, and iodine, among many others. Among these isotopes, lithium isotopes are especially important in various applications including strategic areas. These isotopes are light and hence their separation techniques are not very obvious. Herein, all the main categories of Li isotope separation are reviewed in depth with a focus on electrochemical technologies for stable lithium isotope separation.

Murali, Arun↗

Efficacy of passive sampler collection for atmospheric NO 2 isotopes under simulated environmental conditions

Rationale Nitrogen oxides or NO x (NO x = NO + NO 2 ) play an important role in air quality, atmospheric chemistry, and climate. The isotopic compositions of anthropogenic and natural NO 2 sources are wide‐ranging, and they can be used to constrain sources of ambient NO 2 and associated atmospheric deposition of nitrogen compounds. While passive sample collection of NO 2 isotopes has been used in field studies to determine NO x source influences on atmospheric deposition, this approach has not been evaluated for accuracy or precision under different environmental conditions. Methods The efficacy of NO 2 passive sampler collection for NO 2 isotopes was evaluated under varied temperature and relative humidity (RH) conditions in a dynamic flux chamber. The precision and accuracy of the filter NO 2 collection as nitrite (NO 2 – ) for isotopic analysis were determined using a reference NO 2 gas tank and through inter‐calibration with a modified EPA Method 7. The bacterial denitrifer method was used to convert 20 μM of collected NO 2 – or nitrate (NO 3 – ) into N 2 O and was carried out on an Isoprime continuous flow isotope ratio mass spectrometer. Results δ 15 N‐NO 2 values determined from passive NO 2 collection, in conditions of 11–34 °C, 1–78% RH, have an overall accuracy and precision of ±2.1 ‰, and individual run precision of ±0.6 ‰. δ 18 O‐NO 2 values obtained from passive NO 2 sampler collection, under the same conditions, have an overall precision of ± 1.3 ‰. Conclusions Suitable conditions for passive sampler collection of NO 2 isotopes are in environments ranging from 11 to 34 °C and 1 to 78% RH. The passive NO 2 isotope measurement technique provides an accurate method to determine variations in atmospheric δ 15 N‐NO 2 values and a precise method for determining atmospheric δ 18 O‐NO 2 values. The ability to measure NO 2 isotopes over spatial gradients at the same temporal resolution provides a unique perspective on the extent and seasonality of fluctuations in atmospheric NO 2 isotopic compositions. Copyright © 2017 John Wiley & Sons, Ltd.

Coughlin, Justin G.↗

Neutron Irradiation Induced Changes in Isotopic Abundance of 6Li and 3D Nanoscale Distribution of Tritium in LiAlO2 Pellets Analyzed by Atom Probe Tomography

Tritium, a radioactive isotope of hydrogen is produced by neutron irradiation of 6Li enriched LiAlO2 pellets in Tritium producing burnable absorber rods (TPBARs). Three-dimensional nanoscale mapping of Tritium in irradiated pellets is critical to understand its spatial variation and its association with various microstructural features in the pellets. Spatially resolved analysis of 6Li isotopic enrichment in such ceramic pellets before and after irradiation can provide insights to heterogeneities in Li isotopic distribution. However, Li being a light isotope, its spatially resolved compositional or isotopic analysis is a challenging task to most analytical methods. Here we used atom probe tomography, to evaluate the Li isotopic enrichment in both the LiAlO¬2 matrix and the Li deficient secondary phase LiAl5O8 before irradiation. These results were then compared with 6Li isotopic ratio measured by APT analysis of neutron irradiated pellets to clearly demonstrate the unique capability of APT to quantitatively analyze the isotopic enrichment of 6Li as well as for other light elements present in these materials. Evidence for heterogenous nanoscale distribution of 3H and O3H within irradiated pellet microstructure is also provided, which is attributed to 3H trapping in irradiation induced vacancy clusters or voids within the LiAlO2 matrix. The characterization results given here, now prove the feasibility for using APT for analyzing nanoscale spatially resolved isotopic enrichment of Li as well as other light elements such as Tritium in TPBARs. This work also paves way to adopt APT for analyzing light elements such as Li and tritium in materials used for nuclear fusion reactor applications, geochemistry, astrophysics as well as for energy storage applications.

Devaraj, Arun↗

BENCHMARKING ORTEC ISOTOPIC MEASUREMENTS AND CALCULATIONS

This report represents a description of compiled benchmark tests conducted to probe and to demonstrate the extensive utility of the Ortec ISOTOPIC {gamma}-ray analysis computer program. The ISOTOPIC program performs analyses of {gamma}-ray spectra applied to specific acquisition configurations in order to apply finite-geometry correction factors and sample-matrix-container photon absorption correction factors. The analysis program provides an extensive set of preset acquisition configurations to which the user can add relevant parameters in order to build the geometry and absorption correction factors that the program determines from calculus and from nuclear g-ray absorption and scatter data. The Analytical Development Section field nuclear measurement group of the Savannah River National Laboratory uses the Ortec ISOTOPIC analysis program extensively for analyses of solid waste and process holdup applied to passive {gamma}-ray acquisitions. Frequently the results of these {gamma}-ray acquisitions and analyses are to determine compliance with facility criticality safety guidelines. Another use of results is to designate 55-gallon drum solid waste as qualified TRU waste3 or as low-level waste. Other examples of the application of the ISOTOPIC analysis technique to passive {gamma}-ray acquisitions include analyses of standard waste box items and unique solid waste configurations. In many passive {gamma}-ray acquisition circumstances the container and sample have sufficient density that the calculated energy-dependent transmission correction factors have intrinsic uncertainties in the range 15%-100%. This is frequently the case when assaying 55-gallon drums of solid waste with masses of up to 400 kg and when assaying solid waste in extensive unique containers. Often an accurate assay of the transuranic content of these containers is not required, but rather a good defensible designation as >100 nCi/g (TRU waste) or <100 nCi/g (low level solid waste) is required. In these cases the ISOTOPIC analysis program is especially valuable because it allows a rapid, defensible, reproducible analysis of radioactive content without tedious and repetitive experimental measurement of {gamma}-ray transmission through the sample and container at multiple photon energies. The ISOTOPIC analysis technique is also especially valuable in facility holdup measurements where the acquisition configuration does not fit the accepted generalized geometries where detector efficiencies have been solved exactly with good calculus. Generally in facility passive {gamma}-ray holdup measurements the acquisition geometry is only approximately reproducible, and the sample (object) is an extensive glovebox or HEPA filter component. In these cases accuracy of analyses is rarely possible, however demonstrating fissile Pu and U content within criticality safety guidelines yields valuable operating information. Demonstrating such content can be performed with broad assumptions and within broad factors (e.g. 2-8) of conservatism. The ISOTOPIC analysis program yields rapid defensible analyses of content within acceptable uncertainty and within acceptable conservatism without extensive repetitive experimental measurements. In addition to transmission correction determinations based on the mass and composition of objects, the ISOTOPIC program performs finite geometry corrections based on object shape and dimensions. These geometry corrections are based upon finite element summation to approximate exact closed form calculus. In this report we provide several benchmark comparisons to the same technique provided by the Canberra In Situ Object Counting System (ISOCS) and to the finite thickness calculations described by Russo in reference 10. This report describes the benchmark comparisons we have performed to demonstrate and to document that the ISOTOPIC analysis program yields the results we claim to our customers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ni isotopic compositions in Allende and other meteorites

A new technique for high-precision isotopic analyses of Ni is applied to terrestrial samples, Allende inclusions, and materials from other meteorites. It is noted that most of the Allende inclusions analyzed here were previously reported to contain isotopically anomalous Ti. In contrast, the Ni isotopic abundances are found to be indistinguishable from normal within presently obtainable precision, with only one possible exception. The latter inclusion has been shown by others to contain a significantly fractionated magnesium isotopic pattern of 9 parts per thousand/amu. A normal Ni isotopic pattern has also been observed for the chromite/carbon fraction of an Allende acid residue, which is known to have heavy noble gases of highly anomalous isotopic composition. All other meteoritic samples analyzed reveal normal isotopic compositions of Ni; no evidence for effects from now extinct Fe-60 could be detected. Despite ubiquitous isotopic anomalies in Ti from normal Allende inclusions there is no signature of isotopic variations in Ni from the same samples.

Shimamura, T.↗

Isotopic inferences of ancient biochemistries - Carbon, sulfur, hydrogen, and nitrogen

In processes of biological incorporation and subsequent biochemical processing sizable isotope effects occur as a result of both thermodynamic and kinetic fractionations which take place during metabolic and biosynthetic reactions. In this chapter a review is provided of earlier work and recent studies on isotope fractionations in the biogeochemical cycles of carbon, sulfur, hydrogen, and nitrogen. Attention is given to the biochemistry of carbon isotope fractionation, carbon isotope fractionation in extant plants and microorganisms, isotope fractionation in the terrestrial carbon cycle, the effects of diagenesis and metamorphism on the isotopic composition of sedimentary carbon, the isotopic composition of sedimentary carbon through time, implications of the sedimentary carbon isotope record, the biochemistry of sulfur isotope fractionation, pathways of the biogeochemical cycle of nitrogen, and the D/H ratio in naturally occurring materials.

Schidlowski, M.↗

Stable carbon and sulfur isotopes as records of the early biosphere

The abundance ratios of the stable isotopes of light elements such as carbon and sulfur can differ between various naturally-occurring chemical compounds. If coexisting compounds have achieved mutual chemical and isotopic equilibrium, then the relative isotopic composition can record the conditions at which equilibrium was last maintained. If coexisting chemical compounds indeed formed simultaneously but had not achieved mutual equilibrium, then their relative isotopic compositions often reflect the conditions and mechanisms associated with the kinetically controlled reactions responsible for their production. In the context of Mars, the stable isotopic compositions of various minerals might record not only the earlier environmental conditions of the planet, but also whether or not the chemistry of life ever occurred there. Two major geochemical reservoirs occur in Earth's crust, both for carbon and sulfur. In rocks formed in low temperature sedimentary environments, the oxidized forms of these elements tend to be enriched in the isotope having the larger mass, relative to the reduced forms. In sediments where the organics and sulfides were formed by biological processes, these isotopic contrasts were caused by the processes of biological CO2 fixation and dissimilatory sulfate reduction. Such isotopic contrasts between oxidized and reduced forms of carbon and sulfur are permitted by thermodynamics at ambient temperatures. However, nonbiological chemical reactions associated with the production of organic matter and the reduction of organics and sulfides are extremely slow at ambient temperatures. Thus the synthesis of organics and sulfides under ambient conditions illustrates life's profound role as a chemical catalyst that has altered the chemistry of Earth's crust. Because the stable isotopes of carbon and sulfur can reflect their chemistry, they are useful probes of the Martian surface.

Desmarais, David J.↗

Rare-isotope and kinetic studies of Pt/SnO2 catalysts

Closed-cycle pulsed CO2 laser operation requires the use of an efficient CO-O2 recombination catalyst for these dissociation products which otherwise would degrade the laser operation. The catalyst must not only operate at low temperatures but also must operate efficiently for long periods. In the case of the Laser Atmospheric Wind Sounder (LAWS) laser, an operational lifetime of 3 years is required. Additionally, in order to minimize atmospheric absorption and enhance aerosol scatter of laser radiation, the LAWS system will operate at 9.1 micrometers with an oxygen-18 isotope CO2 lasing medium. Consequently, the catalyst must not only operate at low temperatures but must also preserve the isotopic integrity of the rare-isotope composition in the recombination mode. Several years ago an investigation of commercially available and newly synthesized recombination catalysts for use in closed-cycle pulsed common and rare-isotope CO2 lasers was implemented at the NASA Langley Research Center. Since that time, mechanistic efforts utilizing both common and rare oxygen isotopes have been implemented and continue. Rare-isotope studies utilizing commercially available platinum-tin oxide catalyst have demonstrated that the catalyst contributes oxygen-16 to the product carbon dioxide thus rendering it unusable for rare-isotope applications. A technique has been developed for modification of the surface of the common-isotope catalyst to render it usable. Results of kinetic and isotope label studies using plug flow, recycle plug flow, and closed internal recycle plug flow reactor configuration modes are discussed.

Upchurch, Billy T.↗

Cryogenic Calcite: A Morphologic and Isotopic Analog to the ALH84001 Carbonates

Martian meteorite ALH84001 carbonates preserve large and variable microscale isotopic compositions, which in some way reflect their formation environment. These measurements show large variations (>20%) in the carbon and oxygen isotopic compositions of the carbonates on a 10-20 micron scale that are correlated with chemical composition. However, the utilization of these data sets for interpreting the formation conditions of the carbonates is complex due to lack of suitable terrestrial analogs and the difficulty of modeling under non-equilibrium conditions. Thus, the mechanisms and processes are largely unknown that create and preserve large microscale isotopic variations in carbonate minerals. Experimental tests of the possible environments and mechanisms that lead to large microscale isotopic variations can help address these concerns. One possible mechanism for creating large carbon isotopic variations in carbonates involves the freezing of water. Carbonates precipitate during extensive CO2 degassing that occurs during the freezing process as the fluid s decreasing volume drives CO2 out. This rapid CO2 degassing results in a kinetic isotopic fractionation where the CO2 gas has a much lighter isotopic composition causing an enrichment of 13C in the remaining dissolved bicarbonate. This study seeks to determine the suitability of cryogenically formed carbonates as analogs to ALH84001 carbonates. Specifically, our objective is to determine how accurately models using equilibrium fractionation factors approximate the isotopic compositions of cryogenically precipitated carbonates. This includes determining the accuracy of applying equilibrium fractionation factors during a kinetic process, and determining how isotopic variations in the fluid are preserved in microscale variations in the precipitated carbonates.

Niles, P. B.↗

Endemic Mo Isotopic Anomalies in Iron and Carbonaceous Meteorites

Mo in refractory interstellar grains shows large isotope anomalies. Recent Mo studies showed isotope effects in Allende and Murchison, and in iron meteorites, mesosiderites, and pallasites. Excesses of p- and r-process isotopes (or depletion of sprocess isotopes) of up to 3.5 epsilon units (epsilon u=parts in 10(exp 4)) were reported. We have reported on endemic isotope anomalies in Ru. Other workers have resolved no isotope anomalies for Mo or Ru and have claimed that the work by others is incorrect. Because Ru isotopes can interfere at Mo-96, Mo-98, Mo-100, we improved the chemical separations and eliminated interferences. For Mo work, we used the same solutions from which we separated and analyzed Ru. Three of the iron meteorites (Coahuila, Cape York, and Cape of Good Hope) were chosen for their large Mo isotopic effects. Mo was loaded on outgassed Re filaments, and then reduced; we used Ba(OH)2-NaOH as emitter, and measured Mo in static mode, as MoO3(-). We used Mo-98/Mo-96 for the mass fractionation correction (exponential law). No interferences from Ru or Zr isotopes were detected using the electron multiplier and no corrections were needed. For results on Mo standards we show 2 sigma(not 2 sigma mean) external precision better than: 0.7 epsilon u for Mo-94/Mo-96 and Mo-95/Mo-96; 1.0 epsilon u for Mo-92/Mo-96 and Mo-97/Mo-96; 1.4 epsilon u for Mo-100/Mo-96. Reproducibility for Mo standards is shown as contours (blue lines).

Chen, J. H.↗