Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION MICROSCOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

In situ SEM and ToF-SIMS analysis of IgG conjugated gold nanoparticles at aqueous surfaces

In this study, we report new results of in situ study of 5 nm goat anti-mouse IgG gold nanoparticles in a novel portable vacuum compatible microfluidic device using scanning electron microscope (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The unique feature of the liquid flow cell is that the detection window is open to the vacuum allowing direct probing of the liquid surface. The flow cell is composed of a silicon nitride (SiN) membrane and polydimethylsiloxane (PDMS), and it is fully compatible with vacuum operations for surface analysis. The aperture can be drilled through the 100 nm SiN membrane using a focused ion beam. Characteristic signals of the conjugated gold nanoparticles were successfully observed through the aperture by both energy-dispersive X-ray spectroscopy (EDX) in SEM and ToF-SIMS. Comparison was also made among wet samples, dry samples, and liquid sample in the flow cell using SEM/EDX. Stronger gold signal can be observed in our novel portable device by SEM/EDX compared with the wet or dry samples, respectively. Our results indicate that analyses of the nanoparticle components are better made in their native liquid environment. This is made possible using our unique microfluidic flow cell.

aqueous surface↗

Probing Heterogeneity in Bovine Enamel Composition through Nanoscale Chemical Imaging using Atom Probe Tomography

Objective: The aim of this study was to determine the heterogeneity in chemical composition of bovine enamel using atom probe tomography, and thereby evaluate the suitability of bovine enamel as a substitute for human enamel in in vitro dental research. Design: Enamel samples from extracted bovine incisor teeth were first sectioned using a diamond saw and then milled into needle-like samples (<100 nm diameter) by focused ion beam (FIB) coupled with a scanning electron microscope (SEM). The samples were then analyzed in the atom probe to acquire three-dimensional (3D) images and quantify the atomic chemistry and distribution in bovine enamel. Results: For the first time, the atomic-level composition and clustering of major constituents and impurities within bovine enamel were determined and imaged. We discovered that the chemical composition of bovine enamel is spatially inhomogeneous at the atomic scale. The average bulk Ca/P ratio, ~1.4, was in agreement with previously reported literature values from alternative conventional methods. When assessed locally at the atomic scale, the Ca/P ratio varied between 1.1 and 2.03. We also discovered that the Mg impurities were significantly segregated throughout the enamel, and such clustering influenced the variation of Ca/P ratios. The increase in Mg concentrations, near the Mg clusters, correlated with increased Ca and decreased P concentrations. Conclusion: In conclusion, the presented findings of variability in local composition should be taken into account when interpreting dental research results from bovine enamel.

59 BASIC BIOLOGICAL SCIENCES↗

Synthesis and crystallographic study of Pb-Sr hydroxyapatite solid solutions by high temperature mixing method under hydrothermal conditions

The solid solutions in the system of Pb and Sr hydroxyapatite, Sr{sub 10-x}Pb{sub x}HAp (x = 0-10), were successfully synthesized by high-temperature mixing method (HTMM) at 160 deg. C for 12 h under hydrothermal conditions. The samples were characterized by X-ray diffraction, chemical analysis and electron microscopic observation, and the site of the metal ions in the solid solutions was analyzed with the Rietveld method. The lattice constants, both a and c, of the solid solutions varied linearly with Pb content. It was found that Pb ions in the solid solutions preferentially occupied the M(2) site in the apatite structure. HTMM gives Sr-Pb HAp solid solutions much better crystallization. However, due to the formation of intermediate compound of Pb{sub 3}O{sub 2}(OH){sub 2} in the Pb(NO{sub 3}){sub 2}.4H{sub 2}O solution before mixing with (NH{sub 4}){sub 2}HPO{sub 4} solution at 160 deg. C, HTMM causes the decrease of crystallization of the samples with high Pb content.

36 MATERIALS SCIENCE↗

Irradiation-Induced Grain Growth of gamma-Fe2O3 and Fe3O4 at Cryogenic Temperatures

This work reports the first observations of grain growth under irradiation of Fe oxides, specifically maghemite gamma-Fe2O3 and magnetite Fe3O4. The Fe oxide thin films were grown by Pulsed Laser Deposition and irradiated in-situ in a Transmission Electron Microscope at - 223°C using 1 MeV Kr2+ ions up to 8.75 x 10^19 ions/m^2 to study grain growth kinetics under irradiation. Grain growth at such low temperatures appears to follow kinetics that can be accounted for by the thermal spike model developed for metals in the literature. The corresponding activation energies were calculated and compared with other oxides. The results demonstrate that gamma-Fe2O3, despite its larger initial grain size, exhibits surprisingly fast grain growth in comparison with Fe3O4, likely due to the presence of iron vacancies in the crystal structure that facilitate faster atomic diffusion under irradiation.

Kretov, Dmitrii↗

Nano-Scale Fission Product Phases in an Irradiated U-7Mo Alloy Nuclear Fuel

Irradiated nuclear fuel is a very difficult material to characterize. Due to the large radiation fields associated with these materials, they are hard to handle and typically have to be contained in large hot cells. Even the equipment used for performing characterization is housed in hot cells or shielded glove boxes. The result is not only a limitation in the techniques that can be employed for characterization, but also a limitation in the size of features that can be resolved The most standard characterization techniques include light optical metallography (WM), scanning electron microscopy (SEM), and electron probe microanalysis (EPMA). These techniques are applied to samples that are typically prepared using grinding and polishing approaches that will always generate some mechanical damage on the sample surface. As a result, when performing SEM analysis, for example, the analysis is limited by the quality of the sample surface that can be prepared. However, a new approach for characterizing irradiated nuclear fuel has recently been developed at the Idaho National Laboratory (INL) in Idaho Falls, Idaho. It allows for a dramatic improvement in the quality of characterization that can be performed when using an instrument like an SEM. This new approach uses a dual-beam scanning microscope, where one of the beams isa focused ion beam (FIB), which can be used to generate specimens of irradiated fuel (-10µm x 10µm) for microstructural characterization, and the other beam is the electron beam of an SEM. One significant benefit of this approach is that the specimen surface being characterized has received much less damage (and smearing) than is caused by the more traditional approaches, which enables the imaging of nanometer­ sized microstructural features in the SEM. The process details are for an irradiated low-enriched uranium (LEU) U-Mo alloy fuel Another type of irradiated fuel that has been characterized using this technique is a mixed oxide fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of low temperature baking in nitrogen on the performance of a niobium superconducting radio frequency cavity

Here, we report the rf performance of a single-cell superconducting radiofrequency cavity after low temperature baking in a nitrogen environment. A significant increase in quality factor has been observed when the cavity was heat treated in the temperature range of 120-160 °C with a nitrogen partial pressure of ~25 mTorr. This increase in quality factor as well as the Q-rise phenomenon (anti-Q-slope) is similar to those previously obtained with high temperature nitrogen doping as well as titanium doping. In this study, a cavity N 2 -treated at 120 °C and at 140 °C, showed no degradation in accelerating gradient, however the accelerating gradient was reduced by ~25% with a 160 °C N 2 treatment, compared to the baseline tests after electropolishing. Sample coupons treated in the same conditions as the cavity were analyzed by scanning electron microscope, x-ray photoelectron spectroscopy and secondary ion mass spectroscopy revealed a complex surface composition of Nb 2 O 5 , NbO and NbN (1-x) O x within the rf penetration depth. Furthermore, magnetization measurements showed no significant change on bulk superconducting properties.

36 MATERIALS SCIENCE↗

Running the gamut of high energy nuclear collisions

We present calculations of bulk properties and multiparticle correlations in a large variety of collision systems within a hybrid formalism consisting of IP-Glasma initial conditions, Music viscous relativistic hydrodynamics, and UrQMD microscopic hadronic transport. In particular, we study heavy ion collisions at the Large Hadron Collider (LHC), including Pb + Pb, Xe + Xe, and O + O collisions, and Au + Au, U + U, Ru + Ru, Zr + Zr, and O + O collisions at the Relativistic Heavy Ion Collider (RHIC). We further study asymmetric systems, including p + Au, d + Au, 3 He + Au, and p + Pb collisions at various energies as well as p+p collisions at 0.5 and 13 TeV. Here, we describe experimental observables in all heavy ion systems well with one fixed set of parameters, validating the energy and system dependence of the framework. As a result, many observables in the smaller systems are also well described, although they test the limits of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In situ analysis of potential distribution in Li-ion Batteries

This project accomplished the goal of developing an in situ method of imaging and analysis of local potential distribution in model and composite Li-ion electrodes during charge/discharge process. A scanning probe microscope was used to detect and image potential differences within the composite LCO electrode and the corresponding variations of the active material local state of charge.

25 ENERGY STORAGE↗

Analysis of SEI film on graphitic anode material using NFIR and LIBS

This project accomplished the goal of developing SPM imaging and analysis of local composition of the SEI layer on graphite electrodes in model and composite Li-ion electrodes during charge/discharge process. A scanning probe microscope was used to detect and image chemical composition and structure changes in the SEI layer on graphite electrode at different state of charge.

25 ENERGY STORAGE↗

Request for Information: Access to Quantum Systems

Quantum science and technology is a focal point of research at Lawrence Livermore National Laboratory (LLNL). Quantum-coherent devices offer the potential for unprecedented precision in sensing and the ability to directly simulate complex quantum phenomena that have no known efficient classical algorithms. Thus, development and implementation of quantum technologies is expected to have a significant impact on our ability to address some of the most complex national security problems. LLNL maintains projects involving a broad spectrum of Quantum Information Science (QIS) research activities including investigating sources of decoherence, the 3DQ microscope, studies into quantum interconnects, 3-D printed ion traps, fusion energy and nuclear physics simulations, modeling for data-starved environments, and quantum sensing, including accelerometry and timing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exploring internal structures and properties of terpolymer fibers via real-space characterizations

While significant research has investigated the processing and properties of high-performance terpolymer fibers, much remains to be understood about the internal nano- and microstructures of these fibers, and how these morphologies relate to fiber properties. Here we use a focused ion beam notch technique and multifrequency atomic force microscope mapping to characterize the internal structure and local mechanical properties within Technora ® fibers. We find a highly fibrillated structure that appears to connect with both the fiber’s molecular chemistry and full-fiber mechanical properties. In addition, through detailed comparisons with Kevlar ® K29 fibers, we find remarkable differences between the internal structures of the two fibers, and posit connections between our measurements and multifunctional performance studies from the literature.

36 MATERIALS SCIENCE↗

Ion-beam texturing of materials

Xenon ion-beam source is used to create microscopically-rough surface texture by sputter-etching surface while simultaneously sputter depositing lower yield material onto surface.

Hudson, W. R.↗

The survival of solar flare tracks in interplanetary dust silicates on deceleration in the earth's atmosphere

Pulse heating experiments on magnesium-rich olivine and pyroxene, two silicates often found in micrometeorites collected in the stratosphere, show that iron ion tracks remain detectable in the transmission electron microscope for temperature maxima up to approximately 600 C. Assuming thermal emissivities near unity, this implies that micrometeorites with surface densities above 1 mg/sq cm are likely to have their track record erased, and that tracks in reentrant or low-density micrometeorites smaller than 7 microns in size are likely to survive atmospheric entry.

Fraundorf, P.↗

Proton Radiography for the Diagnostics of a Dense Plasma

The possibility of using high-energy proton radiography for dense plasma diagnostics is discussed. The designed telescopic ion optical system for a proton radiography installation with a 1 GeV beam is presented. The schematic diagram of the proton microscope is given. It is shown that the estimate of spatial resolution for the installation obtained with consideration of chromatic aberrations of magnetic quadrupole lenses is limited from below.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison study of medium-modified QCD shower evolution scenarios

The computation of hard processes in hadronic collisions is a major success of perturbative quantum chromodynamics (pQCD). In such processes, pQCD not only predicts the hard reaction itself, but also the subsequent evolution in terms of parton branching and radiation, leading to a parton shower and ultimately to an observable jet of hadrons. If the hard process occurs in a heavy-ion collision, a large part of this evolution takes place in the soft medium created along with the hard reaction. An observation of jets in heavy-ion collision thus allows a study of medium-modified QCD shower evolution. In vacuum, Monte Carlo (MC) simulations are well established tools to describe such showers. For jet studies in heavy-ion collisions, MC models for in-medium showers are currently being developed. However, the shower-medium interaction depends on the nature of the microscopic degrees of freedom of the medium created in a heavy-ion collision which is the very object one would like to investigate. This paper presents a study in comparison between three different possible implementations for the shower-medium interaction, two of them based on medium-induced pQCD radiation, one of them a medium-induced drag force, and shows for which observables differences between the three scenarios become visible. We find that while single hadron observables such as R{sub AA} are incapable of differentiating between the scenarios, jet observables such as the longitudinal momentum spectrum of hadrons in the jet show the potential to do so.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-D-BRF-01: FEATURED PRESENTATION - Investigating Particle Track Structures Using Fluorescent Nuclear Track Detectors and Monte Carlo Simulations

Purpose: To report on the efforts funded by the AAPM seed funding grant to develop the basis for fluorescent nuclear track detector (FNTD) based radiobiological experiments in combination with dedicated Monte Carlo simulations (MCS) on the nanometer scale. Methods: Two confocal microscopes were utilized in this study. Two FNTD samples were used to find the optimal microscope settings, one FNTD irradiated with 11.1 MeV/u Gold ions and one irradiated with 428.77 MeV/u Carbon ions. The first sample provided a brightly luminescent central track while the latter is used to test the capabilities to observe secondary electrons. MCS were performed using TOPAS beta9 version, layered on top of Geant4.9.6p02. Two sets of simulations were performed, one with the Geant4-DNA physics list and approximating the FNTDs by water, a second set using the Penelope physics list in a water-approximated FNTD and a aluminum-oxide FNTD. Results: Within the first half of the funding period, we have successfully established readout capabilities of FNTDs at our institute. Due to technical limitations, our microscope setup is significantly different from the approach implemented at the DKFZ, Germany. However, we can clearly reconstruct Carbon tracks in 3D with electron track resolution of 200 nm. A second microscope with superior readout capabilities will be tested in the second half of the funding period, we expect an improvement in signal to background ratio with the same the resolution.We have successfully simulated tracks in FNTDs. The more accurate Geant4-DNA track simulations can be used to reconstruct the track energy from the size and brightness of the observed tracks. Conclusion: We have achieved the goals set in the seed funding proposal: the setup of FNTD readout and simulation capabilities. We will work on improving the readout resolution to validate our MCS track structures down to the nanometer scales.

60 APPLIED LIFE SCIENCES↗

A novel facility for 3D micro-irradiation of living cells in a controlled environment by MeV ions

We present a novel facility for micro-irradiation of living targets with ions from a 1.7 MV tandem accelerator. We show results using 1 MeV protons and 2 MeV He{sup 2+}. In contrast to common micro-irradiation facilities, which use electromagnetic or electrostatic focusing and specially designed vacuum windows, we employ a tapered glass capillary with a thin end window, made from polystyrene with a thickness of 1–2 μm, for ion focusing and extraction. The capillary is connected to a beamline tilted vertically by 45°, which allows for easy immersion of the extracted ions into liquid environment within a standard cell culture dish. An inverted microscope is used for simultaneously observing the samples as well as the capillary tip, while a stage-top incubator provides an appropriate environment for the samples. Furthermore, our setup allows to target volumes in cells within a μm{sup 3} resolution, while monitoring the target in real time during and after irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helium ion beam enhanced local etching of silicon nitride

We investigated the effect of the helium ion implantation on the etching rate of silicon nitride in hydrofluoric acid. Helium ions were implanted into 500-nm-thick silicon nitride film with energies from 15 keV to 35 keV. The ion fluence from 10{sup 14} cm{sup −2} to 10{sup 17} cm{sup −2} was used. All samples were investigated with a scanning electron microscope and atomic force microscope. The dependence of the etching rate on the concentration of ion-induced defects is obtained.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗