Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Monitoring the Possible Effects of Corroding Fuel Cladding in Nuclear Ponds: a Modified ROV for Storage Ponds - 20144

Nuclear ponds are used worldwide to store radioactive nuclear material, often for extended periods of time. The pond water conditions need to be closely monitored so that mitigation strategies can be put in place should any leakage of radioactive material occur. This paper describes the selection, development and on-site deployment of a bespoke system whose design was based on of-the-shelf components. The system is able to identify, locate and differentiate the leakage of radioactive material stored in nuclear ponds from the background activity of the water in the pond. The selection of an appropriate detector and monitoring geometry was supported by MCNP modelling which allowed a high degree of confidence in the proposed design. The development of the system allowed a real-time indication of the canister integrity, without incurring the increased operator doses from manual sampling operations that were previously used on site. The benefits of the developed system include the fact that the system is lightweight, easily deployable, retrievable, decontaminable and results in negligible waste products. Moreover, it is able to analyse the samples in-situ, in this way reducing the time needed to manually collect and send the samples to a laboratory for lengthy analysis. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a series of Korean pediatric and adult head computational phantoms and application to nuclear medicine dosimetry - Paper 26

Over the past decades, advances in Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) imaging techniques and an increasing number of new radiopharmaceuticals have resulted in a surge of neuroimaging applications in nuclear medicine on pediatric and adult patients. It is not feasible to directly measure the absorbed dose to the organs of the human body from nuclear medicine procedures. The formalism of the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine has been adopted as the calculation method to estimate radiation dose to target organs from radionuclides distributed in source organs. The absorbed dose to a target organ from different types of radionuclides distributed within source organs can be estimated by the products of the time-integrated activity in each source region and organ dose conversion coefficients, called S values (Gy/MBq-s). S values are computed from a comprehensive set of Specific Absorbed Fraction (SAF), which are calculated from computational human phantoms with realistic anatomical structures coupled with Monte Carlo transport technique. The current SAF data for pediatric and adult head and brain dosimetry is based on a series of stylized computational phantoms. However, dosimetric errors caused by the unrealistic anatomy of stylized phantoms in internal dosimetry calculations have been reported by several studies. In the current study, we developed a series of realistic computational head phantoms representing 6, 9, 12, 15, and 22-year-old standard Korean males, and computed a comprehensive set of SAFs using the phantoms coupled with Monte Carlo transport technique. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Genotoxicity testing of peptides: Folate deprivation as a marker of exaggerated pharmacology

The incidence of micronucleated-cells is considered to be a marker of a genotoxic event and can be caused by direct- or indirect-DNA reactive mechanisms. In particular, small increases in the incidence of micronuclei, which are not associated with toxicity in the target tissue or any structurally altering properties of the compound, trigger the suspicion that an indirect mechanism could be at play. In a bone marrow micronucleus test of a synthetic peptide (a dual agonist of the GLP-1 and GIP receptors) that had been integrated into a regulatory 13-week repeat-dose toxicity study in the rat, small increases in the incidence of micronuclei had been observed, together with pronounced reductions in food intake and body weight gain. Because it is well established that folate plays a crucial role in maintaining genomic integrity and pronounced reductions in food intake and body weight gain were observed, folate levels were determined from plasma samples initially collected for toxicokinetic analytics. A dose-dependent decrease in plasma folate levels was evident after 4 weeks of treatment at the mid and high dose levels, persisted until the end of the treatment duration of 13-weeks and returned to baseline levels during the recovery period of 4 weeks. Based on these properties, and the fact that the compound tested (peptide) per se is not expected to reach the nucleus and cause DNA damage, the rationale is supported that the elevated incidence of micronucleated polychromatic erythrocytes is directly linked to the exaggerated pharmacology of the compound resulting in a decreased folate level. - Highlights: • A synthetic peptide has been evaluated for potential genotoxicity • Small increases in an integrated (13-weeks) micronucleus test were observed • Further, animals had a pronounced reductions in food intake and body weight gain • A dose-dependent decrease in plasma folate levels was evident from week 4 onwards • Elevated micronuclei-incidence due to the exaggerated pharmacology.

60 APPLIED LIFE SCIENCES↗

SU-G-201-01: An Automated Treatment Plan Quality Assurance Program for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this system for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.

60 APPLIED LIFE SCIENCES↗

Comparing probabilistic and descriptive analyses of time–dose–toxicity relationship for determining no-observed-adverse-effect level in drug development

The no-observed-adverse-effect level (NOAEL) of a drug defined from animal studies is important for inferring a maximal safe dose in human. However, several issues are associated with its concept, determination and application. It is confined to the actual doses used in the study; becomes lower with increasing sample size or dose levels; and reflects the risk level seen in the experiment rather than what may be relevant for human. We explored a pharmacometric approach in an attempt to address these issues. We first used simulation to examine the behaviour of the NOAEL values as determined by current common practice; and then fitted the probability of toxicity as a function of treatment duration and dose to data collected from all applicable toxicology studies of a test compound. Our investigation was in the context of an irreversible toxicity that is detected at the end of the study. Simulations illustrated NOAEL's dependency on experimental factors such as dose and sample size, as well as the underlying uncertainty. Modelling the probability as a continuous function of treatment duration and dose simultaneously to data from multiple studies allowed the estimation of the dose, along with its confidence interval, for a maximal risk level that might be deemed as acceptable for human. The model-based data integration also reconciled between-study inconsistency and explicitly provided maximised estimation confidence. Such alternative NOAEL determination method should be explored for its more efficient data use, more quantifiable insight to toxic doses, and the potential for more relevant animal-to-human translation. - Highlights: • Simulations revealed issues with NOAEL concept, determination and application. • Probabilistic modelling was used to address these issues. • The model integrated time-dose-toxicity data from multiple studies. • The approach uses data efficiently and may allow more meaningful human translation.

60 APPLIED LIFE SCIENCES↗

ITER Generic Diagnostic Upper Port Plug Nuclear Heating and Personnel Dose Rate Assesment Neutronics Analysis using the ATTILA Discrete Ordinates Code

Neutronics analysis to find nuclear heating rates and personnel dose rates were conducted in support of the integration of diagnostics in to the ITER Upper Port Plugs. Simplified shielding models of the Visible-Infrared diagnostic and of the ECH heating system were incorporated in to the ITER global CAD model. Results for these systems are representative of typical designs with maximum shielding and a small aperture (Vis-IR) and minimal shielding with a large aperture (ECH). The neutronics discrete-ordinates code ATTILA® and SEVERIAN® (the ATTILA parallel processing version) was used. Material properties and the 500 MW D-T volume source were taken from the ITER “Brand Model” MCNP benchmark model. A biased quadrature set equivelant to Sn=32 and a scattering degree of Pn=3 were used along with a 46-neutron and 21-gamma FENDL energy subgrouping. Total nuclear heating (neutron plug gamma heating) in the upper port plugs ranged between 380 and 350 kW for the Vis-IR and ECH cases. The ECH or Large Aperture model exhibited lower total heating but much higher peak volumetric heating on the upper port plug structure. Personnel dose rates are calculated in a three step process involving a neutron-only transport calculation, the generation of activation volume sources at pre-defined time steps and finally gamma transport analyses are run for selected time steps. ANSI-ANS 6.1.1 1977 Flux-to-Dose conversion factors were used. Dose rates were evaluated for 1 full year of 500 MW DT operation which is comprised of 3000 1800-second pulses. After one year the machine is shut down for maintenance and personnel are permitted to access the diagnostic interspace after 2-weeks if dose rates are below 100 μSv/hr. Dose rates in the Visible-IR diagnostic model after one day of shutdown were 130 μSv/hr but fell below the limit to 90 μSv/hr 2-weeks later. The Large Aperture or ECH style shielding model exhibited higher and more persistent dose rates. After 1-day the dose rate was 230 μSv/hr but was still at 120 μSv/hr 4-weeks later. __________________________________________________

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-392: Superior Brainstem and Cochlea Sparing with VMAT for Glioblastoma Multiforme

Purpose: Volumetric arc therapy (VMAT) can provide similar target coverage and normal tissue sparing as IMRT but with shorter treatment times. At our institution VMAT was adopted for the treatment glioblastoma multiforme (GBM) after a small number of test plans demonstrated its non-inferiority. In this study, we compare actual clinical treatment plans for a larger cohort of patients treated with either VMAT or IMRT. Methods: 90 GBM patients were included in this study, 45 treated with IMRT and 45 with VMAT. All planning target volumes (PTVs) were prescribed a dose of 50 Gy, with a simultaneous integrated boost to 60 Gy. Most IMRT plans used 5 non-coplanar beams, while most VMAT plans used 2 coplanar beams. Statistical analysis was performed using Fisher’s exact test or the Wilcoxon-Mann-Whitney rank sum test. Included in the analysis were patient and treatment characteristics as well as the doses to the target volumes and organs at risk. Results: Treatment times for the VMAT plans were reduced by 5 minutes compared with IMRT. The PTV coverage was similar, with at least 95% covered for all plans, while the median boost PTV dose differed by 0.1 Gy between the IMRT and VMAT cohorts. The doses to the brain, optic chiasm, optic nerves and eyes were not significantly different. The mean dose to the brainstem, however, was 9.4 Gy less with VMAT (p<0.001). The dose to the ipsilateral and contralateral cochleae were respectively 19.7 and 9.5 Gy less (p<0.001). Conclusion: Comparison of clinical treatment plans for separate IMRT and VMAT cohorts demonstrates that VMAT can save substantial treatment time while providing similar target coverage and superior sparing of the brainstem and cochleae. To our knowledge this is the first study to demonstrate this benefit of VMAT in the management of GBM.

60 APPLIED LIFE SCIENCES↗

SU-E-T-56: A Novel Approach to Computing Expected Value and Variance of Point Dose From Non-Gated Radiotherapy Delivery

Purpose: Randomness in patient internal organ motion phase at the beginning of non-gated radiotherapy delivery may introduce uncertainty to dose received by the patient. Concerns of this dose deviation from the planned one has motivated many researchers to study this phenomenon although unified theoretical framework for computing it is still missing. This study was conducted to develop such framework for analyzing the effect. Methods: Two reasonable assumptions were made: a) patient internal organ motion is stationary and periodic; b) no special arrangement is made to start a non -gated radiotherapy delivery at any specific phase of patient internal organ motion. A statistical ensemble was formed consisting of patient’s non-gated radiotherapy deliveries at all equally possible initial organ motion phases. To characterize the patient received dose, statistical ensemble average method is employed to derive formulae for two variables: expected value and variance of dose received by a patient internal point from a non-gated radiotherapy delivery. Fourier Series was utilized to facilitate our analysis. Results: According to our formulae, the two variables can be computed from non-gated radiotherapy generated dose rate time sequences at the point’s corresponding locations on fixed phase 3D CT images sampled evenly in time over one patient internal organ motion period. The expected value of point dose is simply the average of the doses to the point’s corresponding locations on the fixed phase CT images. The variance can be determined by time integration in terms of Fourier Series coefficients of the dose rate time sequences on the same fixed phase 3D CT images. Conclusion: Given a non-gated radiotherapy delivery plan and patient’s 4D CT study, our novel approach can predict the expected value and variance of patient radiation dose. We expect it to play a significant role in determining both quality and robustness of patient non-gated radiotherapy plan.

60 APPLIED LIFE SCIENCES↗

Phase I Trial of Simultaneous In-Field Boost With Helical Tomotherapy for Patients With One to Three Brain Metastases

Purpose: Stereotactic radiosurgery is an alternative to surgical resection for selected intracranial lesions. Integrated image-guided intensity-modulated-capable radiotherapy platforms such as helical tomotherapy (HT) could potentially replace traditional radiosurgery apparatus. The present study's objective was to determine the maximally tolerated dose of a simultaneous in-field boost integrated with whole brain radiotherapy for palliative treatment of patients with one to three brain metastases using HT. Methods and Materials: The inclusion/exclusion criteria and endpoints were consistent with the Radiation Therapy Oncology Group 9508 radiosurgery trial. The cohorts were constructed with a 3 + 3 design; however, additional patients were enrolled in the lower dose tolerable cohorts during the toxicity assessment periods. Whole brain radiotherapy (30 Gy in 10 fractions) was delivered with a 5-30-Gy (total lesion dose of 35-60 Gy in 10 fractions) simultaneous in-field boost delivered to the brain metastases. The maximally tolerated dose was determined by the frequency of neurologic Grade 3-5 National Cancer Institute Common Toxicity Criteria, version 3.0, dose-limiting toxicity events within each Phase I cohort. Results: A total of 48 patients received treatment in the 35-Gy (n = 3), 40-Gy (n = 16), 50-Gy (n = 15), 55-Gy (n = 8), and 60-Gy (n = 6) cohorts. No patients experienced dose-limiting toxicity events in any of the trial cohorts. The 3-month RECIST assessments available for 32 of the 48 patients demonstrated a complete response in 2, a partial response in 16, stable disease in 6, and progressive disease in 8 patients. Conclusion: The delivery of 60 Gy in 10 fractions to one to three brain metastases synchronously with 30 Gy whole brain radiotherapy was achieved without dose-limiting central nervous system toxicity as assessed 3 months after treatment. This approach is being tested in a Phase II efficacy trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integration of an Axcelis Optima HD Single Wafer High Current Implanter for p- and n-S/D Implants in an Existing Batch Implanter Production Line

This paper is focused on the integration and qualification of an Axcelis Optima HD single wafer high current spot beam implanter in an existing 200 mm production line with different types of Axcelis batch implanters for high current applications. Both the design of the beamline and the beam shape are comparable between single wafer and batch high current spot beam implanters. In contrast to the single wafer high current ribbon beam implanter, energy contamination is not a concern for the considered spot beam tool because the drift mode can be used down to energies in the 2 keV region. The most important difference between single wafer and batch high current implanters is the significantly higher dose rate and, therefore, the higher damage rate for the single wafer tool due to the different scanning architecture. The results of the integration of high dose implantations, mainly for p- and n-S/D formation, for DRAM 110 nm without pre-amorphization implantation (PAI), CMOS Logic from around 250 nm down to 90 nm without and with PAI, are presented and discussed. Dopant concentration profile analysis using SIMS was performed for different technologies and implantation conditions. The impurity activation was measured using sheet resistance and in some cases spreading resistance technique was applied. The amorphous layer thickness was measured using TEM. Finally, device data are presented in combination with dose, energy and beam current variations. The results have shown that the integration of implantation processes into crystalline structure without PAI is more complex and time consuming than implantations into amorphous layer where the damage difference due to the different dose rates is negligible.

36 MATERIALS SCIENCE↗

A Comparison of the FW-CADIS and MR-CADIS Variance Reduction Methods

The Consistent Adjoint Driven Importance Sampling (CADIS) method, which uses an adjoint deterministic estimate for making variance reduction parameters that optimize Monte Carlo (MC) shielding calculations, was introduced in 1998. This method was designed to optimize a single tally, typically an integrated response such as a detector count rate or a dose rate. Because both deterministic and stochastic methods are employed, CADIS is referred to as a hybrid method. In 2007, the forward-weighted CADIS (FW-CADIS) method was introduced to optimize several tallies at once, giving more uniform relative uncertainties among the tallies for both high-flux and low-flux areas of the problem. This method can be used for several small detectors, for semi-global problems (mesh tally over a large fraction of the problem), or for global problems (mesh tally over the entire problem). Optimization can be done for an integrated response such as a dose rate D(r) as a function of position, the total flux {phi}(r) as a function of position, or the space/energy flux {phi}(r,E). Both the CADIS and FW-CADIS methods have been in the MAVRIC sequence of SCALE for three versions (6.0 in 2009, 6.1 in 2011, and 6.2 in 2016). The ADVANTG package released in 2015 uses the CADIS and FW-CADIS methods to accelerate MCNP neutron/photon shielding calculations. In 2014, the multi-response CADIS (MR-CADIS) method was presented as a way to obtain even more uniform relative uncertainties for problems with multiple tallies than those obtained with FW-CADIS. The method does not use a forward deterministic calculation but instead uses one adjoint calculation for every tally to be optimized in the Monte Carlo calculation. This work compares the above methods.

42 ENGINEERING↗

Parameters Favorable to Intraprostatic Radiation Dose Escalation in Men With Localized Prostate Cancer

Purpose: To identify , within the framework of a current Phase I trial, whether factors related to intraprostatic cancer lesions (IPLs) or individual patients predict the feasibility of high-dose intraprostatic irradiation. Methods and Materials: Endorectal coil MRI scans of the prostate from 42 men were evaluated for dominant IPLs. The IPLs, prostate, and critical normal tissues were contoured. Intensity-modulated radiotherapy plans were generated with the goal of delivering 75.6 Gy in 1.8-Gy fractions to the prostate, with IPLs receiving a simultaneous integrated boost of 3.6 Gy per fraction to a total dose of 151.2 Gy, 200% of the prescribed dose and the highest dose cohort in our trial. Rectal and bladder dose constraints were consistent with those outlined in current Radiation Therapy Oncology Group protocols. Results: Dominant IPLs were identified in 24 patients (57.1%). Simultaneous integrated boosts (SIB) to 200% of the prescribed dose were achieved in 12 of the 24 patients without violating dose constraints. Both the distance between the IPL and rectum and the hip-to-hip patient width on planning CT scans were associated with the feasibility to plan an SIB (p = 0.002 and p = 0.0137, respectively). Conclusions: On the basis of this small cohort, the distance between an intraprostatic lesion and the rectum most strongly predicted the ability to plan high-dose radiation to a dominant intraprostatic lesion. High-dose SIB planning seems possible for select intraprostatic lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-240: EPID-Based Quality Assurance for Dosimetric Credentialing

Purpose: We propose a novel dosimetric audit method for clinical trials using EPID measurements at each center and a standardized EPID to dose conversion algorithm. The aim of this work is to investigate the applicability of the EPID method to different linear accelerator, EPID and treatment planning system (TPS) combinations. Methods: Combination of delivery and planning systems were three Varian linacs including one Pinnacle and two Eclipse TPS and, two ELEKTA linacs including one Pinnacle and one Monaco TPS. All Varian linacs had the same EPID structure and similarly for the ELEKTA linacs. Initially, dose response of the EPIDs was investigated by acquiring integrated pixel value (IPV) of the central area of 10 cm2 images versus MUs, 5-400 MU. Then, the EPID to dose conversion was investigated for different system combinations. Square field size images, 2, 3, 4, 6, 10, 15, 20, 25 cm2 acquired by all systems were converted to dose at isocenter of a virtual flat phantom then the dose was compared to the corresponding TPS dose. Results: All EPIDs showed a relatively linear behavior versus MU except at low MUs which showed irregularities probably due to initial inaccuracies of irradiation. Furthermore, for all the EPID models, the model predicted TPS dose with a mean dose difference percentage of 1.3. However the model showed a few inaccuracies for ELEKTA EPID images at field sizes larger than 20 cm2. Conclusion: The EPIDs demonstrated similar behavior versus MU and the model was relatively accurate for all the systems. Therefore, the model could be employed as a global dosimetric method to audit clinical trials. Funding has been provided from Department of Radiation Oncology, TROG Cancer Research and the University of Newcastle. Narges Miri is a recipient of a University of Newcastle postgraduate scholarship.

43 PARTICLE ACCELERATORS↗

Assessing the feasibility of volumetric-modulated arc therapy using simultaneous integrated boost (SIB-VMAT): An analysis for complex head-neck, high-risk prostate and rectal cancer cases

Intensity-modulated radiotherapy (IMRT) allowed the simultaneous delivery of different doses to different target volumes within a single fraction, an approach called simultaneous integrated boost (SIB). As consequence, the fraction dose to the boost volume can be increased while keeping low doses to the elective volumes, and the number of fractions and overall treatment time will be reduced, translating into better radiobiological effectiveness. In recent years, volumetric-modulated arc therapy (VMAT) has been shown to provide similar plan quality with respect to fixed-field IMRT but with large reduction in treatment time and monitor units (MUs) number. However, the feasibility of VMAT when used with SIB strategy has few investigations to date. We explored the potential of VMAT in a SIB strategy for complex cancer sites. A total of 15 patients were selected, including 5 head-and-neck, 5 high-risk prostate, and 5 rectal cancer cases. Both a double-arc VMAT and a 7-field IMRT plan were generated for each case using Oncentra MasterPlan treatment planning system for an Elekta Precise linac. Dosimetric indexes for targets and organs at risk (OARs) were compared based on dose-volume histograms. Conformity index, homogeneity index, and dose-contrast index were used for target analyses. The equivalent uniform doses and the normal tissue complication probabilities were calculated for main OARs. MUs number and treatment time were analyzed to score treatment efficiency. Pretreatment dosimetry was performed using 2-dimensional (2D)-array dosimeter. SIB-VMAT plans showed a high level of fluence modulation needed for SIB treatments, high conformal dose distribution, similar target coverage, and a tendency to improve OARs sparing compared with the benchmark SIB-IMRT plans. The median treatment times reduced from 13 to 20 minutes to approximately 5 minutes for all cases with SIB-VMAT, with a MUs reduction up to 22.5%. The 2D-array ion-chambers' measurements reported an agreement of more than 95% for a criterion of 3% to 3 mm. SIB-VMAT was able to combine the advantages of conventional SIB-IMRT with its highly conformal dose distribution and OARs sparing and the advantages of 3D-conformal radiotherapy with its fast delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-69: Cloud-Based Monte Carlo Patient-Specific Quality Assurance (QA) Method for Volumetric Modulated Arc Therapy (VMAT)

Purpose: Patient-specific QA for VMAT is incapable of providing full 3D dosimetric information and is labor intensive in the case of severe heterogeneities or small-aperture beams. A cloud-based Monte Carlo dose reconstruction method described here can perform the evaluation in entire 3D space and rapidly reveal the source of discrepancies between measured and planned dose. Methods: This QA technique consists of two integral parts: measurement using a phantom containing array of dosimeters, and a cloud-based voxel Monte Carlo algorithm (cVMC). After a VMAT plan was approved by a physician, a dose verification plan was created and delivered to the phantom using our Varian Trilogy or TrueBeam system. Actual delivery parameters (i.e., dose fraction, gantry angle, and MLC at control points) were extracted from Dynalog or trajectory files. Based on the delivery parameters, the 3D dose distribution in the phantom containing detector were recomputed using Eclipse dose calculation algorithms (AAA and AXB) and cVMC. Comparison and Gamma analysis is then conducted to evaluate the agreement between measured, recomputed, and planned dose distributions. To test the robustness of this method, we examined several representative VMAT treatments. Results: (1) The accuracy of cVMC dose calculation was validated via comparative studies. For cases that succeeded the patient specific QAs using commercial dosimetry systems such as Delta- 4, MAPCheck, and PTW Seven29 array, agreement between cVMC-recomputed, Eclipse-planned and measured doses was obtained with >90% of the points satisfying the 3%-and-3mm gamma index criteria. (2) The cVMC method incorporating Dynalog files was effective to reveal the root causes of the dosimetric discrepancies between Eclipse-planned and measured doses and provide a basis for solutions. Conclusion: The proposed method offers a highly robust and streamlined patient specific QA tool and provides a feasible solution for the rapidly increasing use of VMAT treatments in the clinic.

60 APPLIED LIFE SCIENCES↗

Verification of source and collimator configuration for Gamma Knife Perfexion using panoramic imaging

Purpose: The new model of stereotactic radiosurgery system, Gamma Knife Perfexion, allows automatic selection of built-in collimation, eliminating the need for the time consuming manual collimator installation required with previous models. However, the configuration of sources and collimators inside the system does not permit easy access for the verification of the selected collimation. While the conventional method of exposing a film at the isocenter is useful for obtaining composite dose information, it is difficult to interpret the data in terms of the integrity of each individual source and corresponding collimation. The primary aim of this study was to develop a method of verifying the geometric configuration of the sources and collimator modules of the Gamma Knife Perfexion. In addition, the method was extended to make dose measurements and verify the accuracy of dose distributions calculated by the mathematical formalism used in the treatment planning system, Leksell Gamma Plan. Methods: A panoramic view of all of 192 cobalt sources was simultaneously acquired by exposing a radiochromic film wrapped around the surface of a cylindrical phantom. The center of the phantom was mounted at the isocenter with its axis aligned along the longitudinal axis of the couch. The sizes and shapes of the source images projected on the phantom surface were compared to those calculated based on the manufacturer's design specifications. The measured dose at various points on the film was also compared to calculations using the algorithm of the planning system. Results: The panoramic images allowed clear identification of each of the 192 sources, verifying source integrity and selected collimator sizes. Dose on the film surface is due to the primary beam as well as phantom scatter and leakage contributions. Therefore, the dose at a point away from the isocenter cannot be determined simply based on the proportionality of collimator output factors; the use of a dose computation algorithm is required. Scatter and leakage dose contributions from neighboring sources were calculated and found to be 6.3% (ranging from 4.5% to 7.4%), 16.7% (12.5%-19.3%), and 66.6% (38%-78%) for the 4, 8, and 16 mm collimators, respectively, at the centers of the source images. The measured average dose on films with 16 mm collimators agrees with the dose model of the treatment planning system to within 1.0%. The average doses on the film were 24.0, 60.8, and 186.2 cGy for 4, 8, and 16 mm diameter collimators, respectively, when the machine was set to deliver a reference dose of 100 Gy to the center of an 80 mm radius spherical dosimetry phantom. Conclusions: A method of simultaneously capturing and analyzing the panoramic images of 192 cobalt sources has been developed to verify the source and collimator configuration of GK systems. The method was extended to verify the dose calculation model of the treatment planning system by comparing the measured doses on the panoramic film images and the corresponding calculated doses. The method presented can play a significant role in comprehensive commissioning and routine quality assurance testing of the Gamma Knife systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-88: Margin Reduction of Level II/III Planning Target Volume for Image-Guided Simultaneous Integrated Boost Head-And-Neck Treatment

Purpose: To investigate the feasibility of improved normal tissue sparing for head-and-neck (H'N) image-guided radiotherapy (IGRT) by employing tighter CTV-to-PTV margins for target level II/III though a GPU-based deformable image registration and dose accumulation framework. Methods: Ten H'N simultaneous integrated boost cases treated on TomoTherapy were retrospectively analyzed. Weekly kVCT scans in addition to daily MVCT scans were acquired for each patient. Reduced margin plans were generated with 0- mm margin for level II and III PTV (while 3-5 mm margin for PTV1) and compared with the standard margin plan using 3-5mm margin to all CTV1-3 (reference plan). An in-house developed GPU-based 3D image deformation tool was used to register and deform the weekly KVCTs with the planning CT and determine the delivered mean/minimum/maximum dose, dose volume histograms (DVHs), etc. Results: Compared with the reference plans, the averaged cord maximum, the right and left parotid doses reduced by 22.7 %, 16.5 %, and 9 % respectively in the reduced margin plans. The V95 for PTV2 and PTV3 were found within 2 and 5% between the reference and tighter margin plans. For the reduced margin plans, the averaged cumulative mean doses were consistent with the planned dose for PTV1, PTV2 and PTV3 within 1.5%, 1.7% and 1.4%. Similar dose variations of the delivered dose were seen for the reference and tighter margin plans. The delivered maximum and mean doses for the cord were 3.55 % and 2.37% higher than the planned doses; a 5 % higher cumulative mean dose for the parotids was also observed for the delivered dose than the planned doses in both plans. Conclusion: By imposing tighter CTV-to-PTV margins for level II and III targets for H'N irradiation, acceptable cumulative doses were achievable when coupled with weekly kVCT guidance while improving normal structure sparing.

60 APPLIED LIFE SCIENCES↗

Spot Scanning Proton Therapy for Malignancies of the Base of Skull: Treatment Planning, Acute Toxicities, and Preliminary Clinical Outcomes

Purpose: To describe treatment planning techniques and early clinical outcomes in patients treated with spot scanning proton therapy for chordoma or chondrosarcoma of the skull base. Methods and Materials: From June 2010 through August 2011, 15 patients were treated with spot scanning proton therapy for chordoma (n=10) or chondrosarcoma (n=5) at a single institution. Toxicity was prospectively evaluated and scored weekly and at all follow-up visits according to Common Terminology Criteria for Adverse Events, version 3.0. Treatment planning techniques and dosimetric data were recorded and compared with those of passive scattering plans created with clinically applicable dose constraints. Results: Ten patients were treated with single-field-optimized scanning beam plans and 5 with multifield-optimized intensity modulated proton therapy. All but 2 patients received a simultaneous integrated boost as well. The mean prescribed radiation doses were 69.8 Gy (relative biological effectiveness [RBE]; range, 68-70 Gy [RBE]) for chordoma and 68.4 Gy (RBE) (range, 66-70) for chondrosarcoma. In comparison with passive scattering plans, spot scanning plans demonstrated improved high-dose conformality and sparing of temporal lobes and brainstem. Clinically, the most common acute toxicities included fatigue (grade 2 for 2 patients, grade 1 for 8 patients) and nausea (grade 2 for 2 patients, grade 1 for 6 patients). No toxicities of grades 3 to 5 were recorded. At a median follow-up time of 27 months (range, 13-42 months), 1 patient had experienced local recurrence and a second developed distant metastatic disease. Two patients had magnetic resonance imaging-documented temporal lobe changes, and a third patient developed facial numbness. No other subacute or late effects were recorded. Conclusions: In comparison to passive scattering, treatment plans for spot scanning proton therapy displayed improved high-dose conformality. Clinically, the treatment was well tolerated, and with short-term follow-up, disease control rates and toxicity profiles were favorable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗