Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INFRARED SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Composition of the Martian aerosols through near-IR spectroscopy

Near-infrared spectroscopy is a powerful technique to study the composition of planetary surfaces, as the main minerals exhibit absorption bands in this spectral range. It gave important information on the mineralogy and petrology of Mars in the past twenty years although in this case it is well known that a large fraction of light is scattered by the airborne particles before reaching the surface. The measured signal is thus the sum of two different contributions that should be studied separately: One from the surface and one from the aerosols that depends on their density, size distribution and composition. Data from the ISM imaging spectrometer are used here to derive the aerosols spectrum. They consist in sets of spectra (from 0.76 to 3.16 microns) of approximately 3000 pixels approximately 25x25 sq km in size. The resulting spectrum exhibits both water-ice and clay mineral features superimposed on a scattering continuum.

Erard, Stephane↗

Infrared Emission Spectroscopy as a Reliability Tool

In this paper we report on a technique based on infrared emission spectroscopy which has been found to be useful for non-contact measurement of the temperature of a hot spot in the gate channel of a GaAs metal/semiconductor field effect transistor (MESFET). The technique was demonstrated on a powered and un-powered GaAs MESFET attaining a spatial resolution of 0.5 microns. A non-destructive submicron-size spot laser beam provided by an HeNe laser excites an extremely small local area of the gate channel of a GaAs MESFET under various operating conditions. Given the state of the experimental test system, we estimate a spatial resolution of about 0.1 microns and a spectral resolution of about 0. I Angstroms. This provides 15 - 100 times finer spatial resolution than can be obtained using the best passive IR systems available. The temperature resolution (less than 0.02 K/micron) of this technique is depend upon the spectrometer used, and that it can be improved further. The information obtained from this technique can be used to estimate device lifetimes for critical applications and for measurement of channel temperature of devices under actual operating conditions. Another potential use of the novel technique can be as a cost-effective prescreening tool for determining the "hot spot" channel temperature of devices under normal operating conditions which can further improve device design, yield enhancement, and reliable operation

Kim, Q.↗

Evaluation of infrared emission spectroscopy for mapping the Moon's surface composition from lunar orbit

Infrared thermal emission spectroscopy is evaluated for its possible application to compositional mapping of the Moon's surface from lunar orbit. Principles of the mid-IR (approximately 4-25 microns) technique, previous lunar ground-based observations, and laboratory studies of Moon samples are reviewed and summarized. A lunar thermal emission spectrometer experiment is described, patterned after a similar instrument on the Mars Observer spacecraft. Thermal emission spectrometry from a polar-orbiting lunar spacecraft could provide a valuable mapping tool to aid in exploration for lunar resources and help provide understanding of the origin of the Moon and history of lunar surface processes.

Nash, Douglas B.↗

Infrared Transmission Spectroscopy of the Exoplanets HD 209458b and XO-1b Using the Wide Field Camera-3 on the Hubble Space Telescope

Exoplanetary transmission spectroscopy in the near-infrared using the Hubble Space Telescope (HST) NICMOS (Near Infrared Camera and Multi-Object Spectrometer) is currently ambiguous because different observational groups claim different results from the same data, depending on their analysis methodologies. Spatial scanning with HST/WFC3 (Wide Field Camera-3) provides an opportunity to resolve this ambiguity.We here report WFC3 spectroscopy of the giant planets HD 209458b and XO-1b in transit, using spatial scanning mode for maximum photon-collecting efficiency. We introduce an analysis technique that derives the exoplanetary transmission spectrum without the necessity of explicitly decorrelating instrumental effects, and achieves nearly photon-limited precision even at the high flux levels collected in spatial scan mode. Our errors are within 6 percent (XO-1) and 26 percent (HD 209458b) of the photon-limit at a resolving power of lambda divided by delta times lambda approximating 70, and are better than 0.01 percent per spectral channel. Both planets exhibit water absorption of approximately 200 ppm at the water peak near 1.38 m. Our result for XO-1b contradicts the much larger absorption derived from NICMOS spectroscopy. The weak water absorption we measure for HD209458b is reminiscent of the weakness of sodium absorption in the first transmission spectroscopy of an exoplanet atmosphere by Charbonneau et al. Model atmospheres having uniformly distributed extra opacity of 0.012 square centimeters per gram account approximately for both our water measurement and the sodium absorption. Our results for HD 209458b support the picture advocated by Pont et al. in which weak molecular absorptions are superposed on a transmission spectrum that is dominated by continuous opacity due to haze and or dust. However,the extra opacity needed for HD 209458b is grayer than for HD 189733b, with a weaker Rayleigh component.

planetary systems↗

Mars: Near-infrared comparative spectroscopy during the 1986 opposition

Near-infrared spectral observations of Mars during the 1986 opposition were performed at the Mauna Kea Observatory utilizing the University of Hawaii's 88 inch telescope. Spectra were obtained of several Martian locations using a continuously variable filter (CVF) spectrometer with a resolution of 1.25 percent. Spot-to-spot ratios were produced between spectra taken in different geological regions.

Bell, James F., III↗

Single photon infrared emission spectroscopy: a study of IR emission from UV laser excited PAHs between 3 and 15 micrometers

Single-photon infrared emission spectroscopy (SPIRES) has been used to measure emission spectra from polycyclic aromatic hydrocarbons (PAHs). A supersonic free-jet expansion has been used to provide emission spectra of rotationally cold and vibrationally excited naphthalene and benzene. Under these conditions, the observed width of the 3.3-micrometers (C-H stretch) band resembles the bandwidths observed in experiments in which emission is observed from naphthalene with higher rotational energy. To obtain complete coverage of IR wavelengths relevant to the unidentified infrared bands (UIRs), UV laser-induced desorption was used to generate gas-phase highly excited PAHs. Lorentzian band shapes were convoluted with the monochromator-slit function in order to determine the widths of PAH emission bands under astrophysically relevant conditions. Bandwidths were also extracted from bands consisting of multiple normal modes blended together. These parameters are grouped according to the functional groups mostly involved in the vibration, and mean bandwidths are obtained. These bandwidths are larger than the widths of the corresponding UIR bands. However, when the comparison is limited to the largest PAHs studied, the bandwidths are slightly smaller than the corresponding UIR bands. These parameters can be used to model emission spectra from PAH cations and cations of larger PAHs, which are better candidate carriers of the UIRs.

Non-NASA Center↗

Planetary spectroscopy

Infrared spectroscopic studies of the solar system in support of spacecraft investigations were researched. The studies include the physical behavior of comets, the atmospheres of the gaseous planets, and the solid surfaces of satellites and asteroids. Studies of the gaseous and solid emanations of comets using the techniques of CCD spectroscopy and imaging were focused on. An intensive observational effort was mounted, to observe comet Halley with the recently developed state of the art CCD camera system. Comet P/Giacobini-Zinner was observed. The major emphasis was placed on spectroscopy and a synoptic spectrum at least once a month was obtained. A large number of images of Halley for particular emission species and continuum regions were also obtained. The species in vestigated were: C3 (4060 A), CO+ (4505), C2 (5139), NH2 (5980), H2O+ (6185), OI (6300) and CN (9180).

Fink, U.↗

Preliminary parameter studies to form pellets of hard materials for optical constants derived via single-angle reflectance spectroscopy

Infrared reflectance spectra can be influenced by many factors: the substrate and the thickness of the layer for liquids and the surface micromorphology, the form (powder, crystal) and the particle size for solids. All these parameters can play a role in the appearance of the measured spectrum. To avoid collecting multitudes of spectra to cover all such scenarios, the optical constants n and k, which are intrinsic properties of a material, can instead be used to model the reflectance spectrum. For solids, two techniques are often used to derive optical constants: ellipsometry and single-angle reflectance spectroscopy. For both methods, best results are usually obtained from single crystals. We have recently demonstrated for ammonium sulfate (a relatively soft material) that by optimizing certain conditions, high quality pellets with specularly reflective surfaces can be used in lieu of crystals. This was confirmed by the excellent agreement between the optical constants derived by these two methods. This work focuses on the possible extension of these methods to harder materials, starting with sodium sulfate. The first goal is to see if high quality pellet surfaces can be obtained as for ammonium sulfate. The reflectance values and the associated optical constants can also be obtained.

Diaz, Emmanuela↗

Insight into the Chemistry of PETN Under Shock Compression Through Ultrafast Broadband Mid-Infrared Absorption Spectroscopy

In this study, thin films of pentaerythritol tetranitrate (PETN) were shock compressed using the laser driven shock apparatus at Los Alamos National Laboratory (LANL). Two spectroscopic probes were available to this apparatus: visible white light transient absorption spectroscopy (VIS) from 400 to 700 nm and mid-infrared transient absorption spectroscopy (MIR) from 1150 to 3800 cm –1 . Important PETN vibrational modes are the symmetric and antisymmetric NO 2 stretches at 1280 and 1650 cm –1 , respectively, as well as CH stretches at ~2900 cm –1 . Shock strength was varied from approximately 3 to 55 GPa to span from the chemically unreactive regime to the regime in which fast chemical reaction took place on the 250 ps time scale of the measurements. VIS and MIR results suggest irreversible chemistry was induced in PETN at pressures above 30 GPa. At lower shock pressures, the spectroscopy showed minimal changes attributable to pressure induced effects. Under the higher-pressure reactive conditions, the frequency region at the antisymmetric NO 2 stretch mode had a significantly increased absorption while the region around the symmetric NO 2 stretch did not. No observable increased absorption occurred in the higher frequency regions where CH-, NH-, and OH- bond absorptions would be observed. A broad absorption appeared on the shoulder at the red-edge of the CO 2 vibrational band around 2200 cm –1 . In addition to the experiments, reactive molecular dynamics were carried out under equivalent shock conditions to correlate the evolution of the infrared spectrum to molecular processes. The simulations show results consistent to experiments up to 30 GPa but suggest that NO and NO 2 related features provided the strongest contributions to the shocked infrared changes. Proposed mechanisms for shocked PETN chemistry are analyzed as consistent or inconsistent with the data presented here. Our experimental data suggests C≡O or N 2 O bond formation, nitrite formation, and absence of significant hydroxyl or amine concentrations in the initial chemistry steps in PETN shocked above 30 GPa.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of dynamic emission spectra from lubricant films in an elastohydrodynamic contact using Fourier transform spectroscopy

Infrared emission spectra were obtained through a diamond window from lubricating fluids in an operating sliding elastohydrodynamic contact and analyzed by comparison with static absorption spectra under similar pressures. Different loads, shear rates and temperatures were used. Most of the spectra exhibited polarization characteristics, indicating directional alignment of the lubricant in the EHD contact. Among the fluids studied were a "traction" fluid, an advanced ester, and their mixtures, a synthetic paraffin, a naphthenic reference fluid (N-1), both neat and containing 1 percent of p-tricresyl phosphate as an anti-wear additive, and a C-ether. Traction properties were found to be nearly proportional to mixture composition for traction fluid and ester mixtures. The anti-wear additive reduced traction and fluid temperature under low loads but increased them under higher loads, giving rise to formation of a friction polymer.

Lauer, J. L.↗

Infrared laser spectroscopy of the linear C13 carbon cluster

The infrared absorption spectrum of a linear, 13-atom carbon cluster (C13) has been observed by using a supersonic cluster beam-diode laser spectrometer. Seventy-six rovibrational transitions were measured near 1809 wave numbers and assigned to an antisymmetric stretching fundamental in the 1 sigma g+ ground state of C13. This definitive structural characterization of a carbon cluster in the intermediate size range between C10 and C20 is in apparent conflict with theoretical calculations, which predict that clusters of this size should exist as planar monocyclic rings.

Non-NASA Center↗

Examination of Mars2020 Shock-Layer Conditions Via Infrared Emission Spectroscopy of CO2

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing flight conditions encountered during the Mars2020 mission entry into Mars atmosphere. For this test series, the EAST facility was instrumented with two spectrometers for Optical Emission Spectroscopy (OES) measurements and three mid-infrared lasers for Tunable Diode Laser Absorption Spectroscopy (TDLAS). This study focuses on the spectrally and spatially resolved radiance measured with OES. Comparison with CEA/NEQAIR and DPLR/NEQAIR simulations were made. For velocity above 2.7 km/s, measurements are found to lie between the different tested kinetic models, within ± 10%. Below 2.7 km/s, the chemistry appears to be frozen and measured radiance profiles are typically 10% above CEA predictions. This difference is explained by shock deceleration effects. Finally, comparison between OES and TDLAS data are made and show a good agreement on the measured temperature and CO2 number density profiles using the two diagnostics, typically within 10 and 5%, respectively.

Augustin C Tibere-Inglesse↗

Examination of Mars2020 Shock-Layer Conditions Via Infrared Emission Spectroscopy of CO2

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing flight conditions encountered during the Mars2020 mission entry into Mars atmosphere. For this test series, the EAST facility was instrumented with two spectrometers for Optical Emission Spectroscopy (OES) measurements and three mid-infrared lasers for Tunable Diode Laser Absorption Spectroscopy (TDLAS). This study focuses on the spectrally and spatially resolved radiance measured with OES. Comparison with CEA/NEQAIR and DPLR/NEQAIR simulations were made. For velocity above 2.7 km/s, measurements are found to lie between the different tested kinetic models, within ± 10%. Below 2.7 km/s, the chemistry appears to be frozen and measured radiance profiles are typically 10% above CEA predictions. This difference is explained by shock deceleration effects. Finally, comparison between OES and TDLAS data are made and show a good agreement on the measured temperature and CO2 number density profiles using the two diagnostics, typically within 10 and 5%, respectively.

Augustin Tibère-Inglesse↗

Pu(IV) quantification via visible–near-infrared absorption spectroscopy: tackling interferences using D-optimal design and partial least squares

Here, this study presents a novel analytical approach for quantifying Pu(IV) in glove box environments using fiber-optic-based visible–near-infrared absorption spectroscopy in combination with partial least squares regression (PLSR) and design of experiments. The method addresses significant challenges posed by overlapping spectral features arising from Nd(III), which is a common fission product impurity, and the speciation variability of Pu(IV) nitrato complexes in HNO 3 concentrations ranging from 2.5 to 11 M. A curated training set consisting of data from 20 samples was developed via D-optimal design to enable robust PLSR model calibration for Pu(IV) using the near-infrared band near 1050 nm. The training set was acquired from samples in cuvettes with a 1-cm path length and was used to build the PLSR model. The robustness of the model was validated with data collected using a dip probe with a 1-cm path length and varying Pu(IV) concentrations. The strong performance of the model indicates good model transfer from cuvette to dip probe and highlights the potential for in situ measurements and online monitoring of reactions in a crystallization reactor vessel. The results demonstrate that this combined spectroscopic and chemometric approach can accurately and simultaneously quantify Pu(IV) and HNO 3 , thereby offering a promising tool for real-time monitoring in process environments.

Actinide↗

Infrared absorption spectroscopy of dynamically compressed water

Streaked visible spectroscopy is well established in dynamic compression research. Infrared measurements remain problematic, however, due to the diminishing sensitivity of streak camera photocathodes beyond 800 nm. Time-stretch techniques offer an alternative method for probing infrared features during single-event experiments. This paper discusses the development of a time-stretch spectroscopy diagnostic using dispersed supercontinuum laser pulses. The technique is applied to near-infrared measurements of liquid water during multiple shock compression.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate frequency of the 119 micron methanol laser from tunable far-infrared absorption spectroscopy

High-accuracy absorption spectroscopy of CH3OH in the far infrared is discussed. In addition to 22 transitions in the ground state, the frequency of the (n, tau, J, K), (0, 1, 16, 8) to (0, 2, 15, 7) transition in the nu5 excited vibrational level, which is responsible for the laser emission at 119 microns, was measured. The measured frequency is 2,522,782.57(10) MHz at zero pressure, with a pressure shift of 6.1(32) kHz/Pa (0.805/420/ MHz/torr). An accurate remeasurement of the laser emission frequency has also been performed, and the results are in good agreement.

Inguscio, M.↗

Background-Limited Infrared-Submillimeter Spectroscopy (BLISS)

The bulk of the cosmic far-infrared background light will soon be resolved into its individual sources with Spitzer, Astro-F, Herschel, and submm/mm ground-based cameras. The sources will be dusty galaxies at z approximately equal to 1-4. Their physical conditions and processes in these galaxies are directly probed with moderate-resolution spectroscopy from 20 micrometers to 1 mm. Currently large cold telescopes are being combined with sensitive direct detectors, offering the potential for mid-far-IR spectroscopy at the background limit (BLISS). The capability will allow routine observations of even modest high-redshift galaxies in a variety of lines. The BLISS instrument's capabilities are described in this presentation.

spectrometers↗