Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPACT LOAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

NON-NEWTONIAN FLUID CAVERN AND NEWTONIAN CLOUD HEIGHT TESTS TO CHARACTERIZE PULSE JET MIXER OPERATION

Pulse jet mixing systems are being developed for use in the Waste Treatment Plant in Washington State. To assist with system development, scaled tests were conducted to obtain experimental measurements of the cloud height for Newtonian slurries and cavern heights for a Non-Newtonian yield stress material. The measurements were required to assess the effective mixing and material mobilization produced during pulse jet mixer operation. The cloud height measurements were obtained for a single steady-state jet directed downward in a spherical-bottom tank. The cloud tests used glass beads in water to evaluate the height of the suspended slurry as a function of jet velocity. Cloud testing revealed that the glass bead material was suspended in the tank quickly and developed a distinctive height for each combination of flow rate and particulate size tested. The solids loading had minimal impact on the cloud height for a given particle size. During all cloud tests, the surface of the tank remained relatively calm, indicating that the slurry was dissipating the mixing energy of the relatively high velocity jet. Cavern tests were conducted to obtain experimental data of non-Newtonian fluid mixing for fluid properties similar to those of certain tank wastes. A transparent material that exhibited a yield stress and shear thinning behavior was used to obtain measurements of steady-state cavern heights as a function of jet velocity. For the non-Newtonian fluid cavern tests, distinct cavern volumes were readily developed for the four velocities tested. A linear relationship was observed to exist between cavern height and nozzle velocity. Since the experimental work detailed in this paper was completed, additional scaled tests have been conducted with pneumatic drive systems and direct drive systems similar to that described for this effort. Data from both types of measurements are shown to be linear; however, effects from the reciprocating drive systems that are not yet incorporated into models may be affecting the ability to collapse this data independent of scale. It is recommended that future efforts to assess performance of PJM operations using scaled tests consider employing direct drive systems to aid in evaluating scaling trends. A test system can be configured to allow testing at both reciprocating and direct drive conditions; thereby allowing direct comparison between them.

cloud height tests↗

Attenuation of wall disturbances in an electron cyclotron resonance oxygen–argon plasma using real time control

Present practice in plasma-assisted semiconductor manufacturing specifies recipes in terms of inputs such as gas flow rates, power and pressure. However, ostensibly identical chambers running identical recipes may produce very different results. Extensive chamber matching, i.e., initial iterative, empirical tuning of the process recipe, which entails time-consuming, ex situ statistical analysis of process metrics such as etch depth, uniformity, anisotropy and selectivity, is required to ensure acceptable results. Once matched, chambers are run open loop and are thus sensitive to disturbances such as actuator drift, wall seasoning and substrate loading, which may impact negatively on process reproducibility. An alternative approach, which may obviate the need for chamber matching and reduce the sensitivity of process metrics to exogenous disturbances, would be to specify a recipe in terms of quantities such as active species densities, and to regulate these in real time by adjusting the inputs with a suitable control algorithm. In this work, real time control of an electron cyclotron resonance O{sub 2}/Ar plasma used for photoresist ashing has been implemented. The design of elementary, model-based algorithms for the control of the argon 750 and oxygen 844 line intensities measured by optical emission spectroscopy is described. Fluorination of the chamber walls by means of an SF{sub 6} plasma prior to ashing inhibits wall recombination of oxygen radicals resulting in an approximately 20% increase in ash rate in the open loop case. However, closed loop control almost completely attenuates the effect of fluorination, thus demonstrating the efficacy of the control algorithms in ensuring a reproducible ash rate in the face of a wall disturbance.

42 ENGINEERING↗

Residential Simulation Tool

Residential Simulation Tool was developed to understand the impact of residential load consumption on utilities including the role of demand response. This is complicated as many different residential loads exist and are utilized for different purposes. The tool models human behavior and contributes this to load utilization, which contributes to the electrical consumption prediction by the tool. The tool integrates a number of different databases from Department of Energy and other Government websites to support the load consumption prediction.

Starke, MichaelR↗

tell: a Python package to model future total electricity loads in the United States

The purpose of the Total ELectricity Load (tell) model is to generate 21st century profiles of hourly electricity load (demand) across the Conterminous United States (CONUS). tell loads reflect the impact of climate and socioeconomic change at a spatial and temporal resolution adequate for input to an electricity grid operations model. tell uses machine learning to develop profiles that are driven by projections of climate/meteorology and population. tell also harmonizes its results with United States (U.S.) state-level, annual projections from a national- to global-scale energy-economy model. This model accounts for a wide range of other factors affecting electricity demand, including technology change in the building sector, energy prices, and demand elasticities, which stems from model coupling with the U.S. version of the Global Change Analysis Model (GCAM-USA). tell was developed as part of the Integrated Multisector Multiscale Modeling (IM3) project. IM3 explores the vulnerability and resilience of interacting energy, water, land, and urban systems in response to compound stressors, such as climate trends, extreme events, population, urbanization, energy system transitions, and technology change

24 POWER TRANSMISSION AND DISTRIBUTION↗

Baseline Glass Development for Combined Fission Products Waste Streams

Borosilicate glass was selected as the baseline technology for immobilization of the Cs/Sr/Ba/Rb (Cs), lanthanide (Ln) and transition metal fission product (TM) waste steams as part of a cost benefit analysis study. Vitrification of the combined waste streams have several advantages, minimization of the number of waste forms, a proven technology, and similarity to waste forms currently accepted for repository disposal. A joint study was undertaken by Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) to develop acceptable glasses for the combined Cs + Ln + TM waste streams (Option 1) and Cs + Ln combined waste streams (Option 2) generated by the AFCI UREX+ set of processes. This study is aimed to develop baseline glasses for both combined waste stream options and identify key waste components and their impact on waste loading. The elemental compositions of the four-corners study were used along with the available separations data to determine the effect of burnup, decay, and separations variability on estimated waste stream compositions. Two different components/scenarios were identified that could limit waste loading of the combined Cs + LN + TM waste streams, where as the combined Cs + LN waste stream has no single component that is perceived to limit waste loading. Combined Cs + LN waste stream in a glass waste form will most likely be limited by heat due to the high activity of Cs and Sr isotopes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Side-by-Side Field Evaluation of Highly Insulating Windows in the PNNL Lab Homes

To examine the energy, air leakage, and thermal performance of highly insulating windows, a field evaluation was undertaken in a matched pair of all-electric, factory-built “Lab Homes” located on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington. The “baseline” Lab Home B was retrofitted with “standard” double-pane clear aluminum-frame slider windows and patio doors, while the “experimental” Lab Home A was retrofitted with Jeld-Wen® triple-pane vinyl-frame slider windows and patio doors with a U-factor of 0.2 and solar heat gain coefficient of 0.19. To assess the window, the building shell air leakage, energy use, and interior temperatures of each home were compared during the 2012 winter heating and summer cooling seasons. The measured energy savings in Lab Home B averaged 5,821 watt-hours per day (Wh/day) during the heating season and 6,518 Wh/day during the cooling season. The overall whole-house energy savings of Lab Home B compared to Lab Home A are 11.6% ± 1.53% for the heating season and 18.4 ± 2.06% for the cooling season for identical occupancy conditions with no window coverings deployed. Extrapolating these energy savings numbers based on typical average heating degree days and cooling degree days per year yields an estimated annual energy savings of 12.2%, or 1,784 kWh/yr. The data suggest that highly insulating windows are an effective energy-saving measure that should be considered for high-performance new homes and in existing retrofits. However, the cost effectiveness of the measure, as determined by the simple payback period, suggests that highly insulating window costs continue to make windows difficult to justify on a cost basis alone. Additional reductions in costs via improvements in manufacturing and/or market penetration that continue to drive down costs will make highly insulating windows much more viable as a cost-effective energy efficiency measure. This study also illustrates that highly insulating windows have important impacts on peak load, occupant comfort, and condensation potential, which are not captured in the energy savings calculation. More consistent and uniform interior temperature distributions suggest that highly insulated windows, as part of a high performance building envelope, may enable more centralized duct design and downsized HVAC systems. Shorter, more centralized duct systems and smaller HVAC systems to yield additional cost savings, making highly insulating windows more cost effective as part of a package of new construction or retrofit measures which achieve significant reductions in home energy use.

PNNL Lab Homes↗

Field Evaluation of Four Novel Roof Designs for Energy-Efficient Manufactured Homes

A five-bay roof test structure was built, instrumented and monitored in an effort to determine through field testing and analysis the relative contributions of select technologies toward reducing energy use in new manufactured homes. The roof structure in Jamestown, California was designed to examine how differences in roof construction impact space conditioning loads, wood moisture content and attic humidity levels. Conclusions are drawn from the data on the relative energy and moisture performance of various configurations of vented and sealed attics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Evaluation of Four Novel Roof Designs for Energy-Efficient Manufactured Homes

"9A five-bay roof test structure was built, instrumented and monitored in an effort to determine through field testing and analysis the relative contributions of select technologies toward reducing energy use in new manufactured homes. The roof structure in Jamestown, California was designed to examine how differences in roof construction impact space conditioning loads, wood moisture content and attic humidity levels. Conclusions are drawn from the data on the relative energy and moisture performance of various configurations of vented and sealed attics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Support for HLW Direct Feed - Phase 2, VSL-15R3440-1

This report describes work performed to develop and test new glass and feed formulations originating from a potential flow-sheet for the direct vitrification of High Level Waste (HLW) with minimal or no pretreatment. In the HLW direct feed option that is under consideration for early operations at the Hanford Tank Waste Treatment and Immobilization Plant (WTP), the pretreatment facility would be bypassed in order to support an earlier start-up of the vitrification facility. For HLW, this would mean that the ultrafiltration and caustic leaching operations that would otherwise have been performed in the pretreatment facility would either not be performed or would be replaced by an interim pretreatment function (in-tank leaching and settling, for example). These changes would likely affect glass formulations and waste loadings and have impacts on the downstream vitrification operations. Modification of the pretreatment process may result in: (i) Higher aluminum contents if caustic leaching is not performed; (ii) Higher chromium contents if oxidative leaching is not performed; (iii) A higher fraction of supernate in the HLW feed resulting from the lower efficiency of in-tank washing; and (iv) A higher water content due to the likely lower effectiveness of in-tank settling compared to ultrafiltration. The HLW direct feed option has also been proposed as a potential route for treating HLW streams that contain the highest concentrations of fast-settling plutoniumcontaining particles, thereby avoiding some of the potential issues associated with such particles in the WTP Pretreatment facility [1]. In response, the work presented herein focuses on the impacts of increased supernate and water content on wastes from one of the candidate source tanks for the direct feed option that is high in plutonium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of commercially available energy-efficient room air conditioners including models with low global warming potential (GWP) refrigerants

Improving the energy efficiency of room air conditioners (RACs) while transitioning to low global-warming-potential (GWP) refrigerants will be a critical step toward reducing the energy, peak load, and emissions impacts of RACs while keeping costs low. Previous research quantified the benefits of leapfrogging to high efficiency in tandem with the transition to low-GWP refrigerants for RACs (Shah et al., 2015) and identified opportunities for initial action to coordinate energy efficiency with refrigerant transition in economies constituting about 65% of the global RAC market (Shah et al., 2017). This report describes further research performed to identify the best-performing (i.e., most efficient and low-GWP-refrigerant using) RACs on the market, to support an understanding of the best available technology (BAT). Understanding BAT can help support market-transformation programs for high-efficiency and low-GWP equipment such as minimum energy performance standards (MEPS), labeling, procurement, and incentive programs. We studied RACs available in six economies—China, Europe, India, Japan, South Korea, and the United States—that together account for about 70% of global RAC demand, as well as other emerging economies. The following are our key findings: • Highly efficient RACs using low-GWP refrigerants, e.g., HFC-32 (R-32) and HC-290 (R-290), are commercially available today at prices comparable to similar RACs using high-GWP HCFC-22 (R-22) or HFC-410A (R-410A). • High efficiency is typically a feature of high-end products. However, highly efficient, cost-competitive (less than 1,000 or 1,500 U.S. dollars in retail price, depending on size) RACs are available. • Where R-22 is being phased out, high GWP R-410A still dominates RAC sales in most mature markets except Japan, where R-32 dominates. • In all of the economies studied except Japan, only a few models are energy efficient and use low-GWP refrigerants. For example, in Europe, India, and Indonesia, the highest-efficiency RAC models employ the low-GWP refrigerants R-32 or R-290. • RACs are available in most regions and worldwide that surpass the highest efficiency levels recognized by labeling programs. • Fixed-speed RACs using high-GWP and ozone-depleting R-22 refrigerant still dominate the market in many emerging economies. There is significant scope to improve RAC efficiency and transition to low-GWP refrigerants using commercially available technology and to design market-transformation programs for high-efficiency, low-GWP equipment including standards, labeling, procurement, and incentive programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Uncertainty and Risk Assessment in the Design Process for Wind

This report summarizes the concepts and opinions that emerged from an initial study on the subject of uncertainty in wind design that included expert elicitation during a workshop held at the National Wind Technology Center at the National Renewable Energy Laboratory July 12-13, 2016. In this paper, five major categories of uncertainties are identified. The first category is associated with direct impacts on turbine loads, (i.e., the inflow including extreme events, aero-hydro-servo-elastic response, soil-structure inter- action, and load extrapolation). The second category encompasses material behavior and strength. Site suitability and due-diligence aspects pertain to the third category. Calibration of partial safety factors and optimal reliability levels make up the fourth one. And last but not least, is the category associated with uncertainties in computational modeling. The main sections of this paper follow this organization.

17 WIND ENERGY↗

Return on Investment (ROI) Framework Case Study: CTH.

CTH is a Eulerian code developed at Sandia National Laboratories capable of modeling the hydrodynamic response of explosives, liquids, gases, and solids. The code solves complex multi-dimensional problems characterized by large deformations and strong shocks that are composed of various material configurations. CTH includes models for material strength, fracture, porosity, and high explosive detonation and initiation. The code is an acronym for a complex series of names relating to its origin. A full explanation can be seen in Appendix A. The software breaks penetration simulations into millions of grid-like “cells”. As a modeled projectile impacts and penetrates a target, progressively smaller blocks of cells are placed around the projectile, which show in detail deformations and breakups. Additionally, the code is uniquely suited to modeling blunt impact and blast loading leading to human body injury.

42 ENGINEERING↗

Assessment of JBEI Ionic Liquid Biomass Pretreatment Technology on POET Feedstocks

This CRADA was focused on the development, demonstration and optimization of advanced biomass conversion technologies, specifically the one-pot ionic liquid (IL) technology pioneered at the Joint BioEnergy Institute, on feedstocks that are of primary interest to POET. The aim of this study is to provide a comprehensive analysis of comparative material balance and process yields after different IL pretreatment configurations through a parametric study of the efficacy of [C 2 C 1 Im][OAc] and [Ch][Lys] for the pretreatment of corn stover in order to establish the upper and lower limits for IL pretreatment. This included evaluating the impact of solids loading, particle size, temperature and enzyme loading on both IL pretreatment and sugar yields.

09 BIOMASS FUELS↗

Challenges and Recommended Policies for Simultaneous Global Implementation of Low-GWP Refrigerants and High Efficiency in Room Air Conditioners

Increasing incomes, electrification, and urbanization—as well as a warming world—are driving up the global stock of air conditioners (ACs), particularly in emerging economies with hot climates. AC energy consumption is expected to increase substantially as the global stock of room ACs rises to 1.5 billion in 2030 and 2.5 billion in 2050. Hence, improving AC energy efficiency will be critical to reducing AC energy, cost (consumer lifecycle cost, electricity generation cost, etc.), peak load, and emissions impacts. The 2016 Kigali Amendment to the Montreal Protocol offers an opportunity to improve AC energy efficiency in tandem with the phasedown of high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants. Based on the most recent information, a literature review, and interviews with manufacturers and industry experts, we find the main barriers to deploying high-efficiency ACs include concerns about market demand and cost, which could be mitigated by appropriately improved design of market-transformation programs such as standards and labeling, incentive, and procurement programs. The main barriers to the low-GWP refrigerant transition include the need for timely revision of safety standards and associated costs for capacity-building activities allowing safe use of low-GWP refrigerants in ACs. Policy action and the market transformation can be accelerated by advancing the refrigerant transition and efficiency improvements in parallel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Validation of Multi-Zone HVAC System Model: Evaluation of Existing Infiltration Models used in Building Energy Simulation

Infiltration can have a significant impact on building loads. Studies have shown that infiltration can account for 15-40% of annual space conditioning needs in commercial buildings (Emmerich et al. 2019; Younes et al. 2012). The driving force of infiltration is the pressure difference across the building envelope caused by wind, the stack effect (known as buoyancy effect), and the operation of ventilation equipment. Wind pressure is governed by wind direction, speed, building shape, and other structures around the building. The stack effect is a function of the building height and air density differences of ambient air (Han, 2015). The effect of wind is dominant in low-rise residential buildings, and the stack effect is dominant in highrise buildings (ASHRAE 2017). In building energy simulation programs (e.g., EnergyPlus), various empirical infiltration models (e.g., the effective leakage area model, the flow coefficient model) are available to simulate infiltration rates. To help users in selecting a proper infiltration model for modeling of the two-story Flexible Research Platform (FRP), the team evaluates the existing infiltration models in EnergyPlus based on field measurements from the FRP. The blower door and tracer gas decay tests were performed in the FRP. The blower door test result was used to estimate input parameters required in the infiltration models. The actual infiltration rates were estimated with the tracer gas decay test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aeroacoustic Assessment of Wind Plant Controls

The Aeroacoustic Assessment project aims to quantify changes in aeroacoustic noise generation by a utility scale wind turbine operating under imposed yaw offsets common for wake steering and wind plant control strategies. Active plant control utilizing wake deflection control strategies have been shown experimentally and computationally to reliably produce 1-2% of additional annual energy production (AEP) without significant changes in turbine structural loads, the potential impact on aeroacoustic emissions has yet to be quantified or completely understood. Yawed operation of a wind turbine changes the three-dimensional aerodynamic interaction between the rotor blades and the incoming atmospheric flow, leading to changes in noise generation. This work quantifies the extent to which active control induces additional aeroacoustic emissions from additional separation and other flow interaction dynamic effects. Given public concerns about wind turbine noise and the need for observational data required for regulators to establish noise restrictions, we must understand potential acoustic emissions resulting from active control prior to commercial deployment and the development of practical noise reduction methods and technologies. The work outlined in this report details the new aeroacoustic measurement capability developed at NREL and its application to making full-field observations of noise from a utility-scale wind turbine. Preliminary noise modeling with the aeroacoustics module in OpenFAST helped to establish the design of the experiment, specifically targeting the noise observed at observers distributed around the DOE-owned GE 1.5 MW wind turbine. Low-frequency and infrasound measurement capability implemented in this project establish an operational baseline for the wind turbine, setting the stage for future control, rotor blade, and turbine design research.

17 WIND ENERGY↗