Moisture and Structural Analysis for High Performance Hybrid Wall Assemblies

This report describes the work conducted by the Building Science Corporation (BSC) Building America Research Team's 'Energy Efficient Housing Research Partnerships' project. Based on past experience in the Building America program, they have found that combinations of materials and approaches—in other words, systems—usually provide optimum performance. No single manufacturer typically provides all of the components for an assembly, nor has the specific understanding of all the individual components necessary for optimum performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system operations control strategy.

Ceiling Panels↗

Time-of-Use and Demand Charge Battery Controller Using Stochastic Model Predictive Control: Preprint

Stationary batteries in residential and commercial buildings are often used to smooth customer load profiles and to lower customer electricity bills. Controllers for these battery systems should account for customer energy consumption, rate structures, and high internal battery temperatures, which can lead to reduced performance over the battery lifetime. It is important to consider the uncertainty in forecasting energy consumption and temperature, especially for customers with highly variable and uncertain loads. We propose a novel battery controller using stochastic model predictive control that accounts for these uncertainties and can handle complex rate structures, including demand charges. We show that the controller performs better than standard model predictive control when there is significant uncertainty in the forecast. We also show improvements in the performance with more accurate forecasts and with a more aggressive control strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Battery Control Using Stochastic Model Predictive Control

Stationary batteries in residential and commercial buildings are often used to smooth customer load profiles and to lower customer electricity bills. Controllers for these battery systems should account for customer energy consumption, rate structures, and high internal battery temperatures, which can lead to reduced performance over the battery lifetime. It is important to consider the uncertainty in forecasting energy consumption and temperature, especially for customers with highly variable and uncertain loads. We propose a novel battery controller using stochastic model predictive control that accounts for these uncertainties and can handle complex rate structures, including demand charges. We show that the controller performs better than standard model predictive control when there is significant uncertainty in the forecast. We also show improvements in the performance with more accurate forecasts and with a more aggressive control strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-Flow Liquid Desiccant Air-Conditioning: Demonstrated Performance and Cost Implications

Cooling loads must be dramatically reduced when designing net-zero energy buildings or other highly efficient facilities. Advances in this area have focused primarily on reducing a building's sensible cooling loads by improving the envelope, integrating properly sized daylighting systems, adding exterior solar shading devices, and reducing internal heat gains. As sensible loads decrease, however, latent loads remain relatively constant, and thus become a greater fraction of the overall cooling requirement in highly efficient building designs, particularly in humid climates. This shift toward latent cooling is a challenge for heating, ventilation, and air-conditioning (HVAC) systems. Traditional systems typically dehumidify by first overcooling air below the dew-point temperature and then reheating it to an appropriate supply temperature, which requires an excessive amount of energy. Another dehumidification strategy incorporates solid desiccant rotors that remove water from air more efficiently; however, these systems are large and increase fan energy consumption due to the increased airside pressure drop of solid desiccant rotors. A third dehumidification strategy involves high flow liquid desiccant systems. These systems require a high maintenance separator to protect the air distribution system from corrosive desiccant droplet carryover and so are more commonly used in industrial applications and rarely in commercial buildings. Both solid desiccant systems and most high-flow liquid desiccant systems (if not internally cooled) add sensible energy which must later be removed to the air stream during dehumidification, through the release of sensible heat during the sorption process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Temperature Erosion Modeling in Particle Based CSP Systems

1. Introduction. Wear and erosion damage of materials from solid particle and surface interactions is a major issue in various industries. Although more common in mining and oil and gas production, erosion is becoming a critical issue in renewable technologies as well such as particle based concentrated solar thermal power (CSP) systems. In particle based CSP systems, solid particles are used to absorb solar energy and as thermal storage. However, these particles may cause significant amount of wear to system components while through the system at high temperatures. This damage can be costly, and therefore, requires a greater understanding of solid particle erosion in CSP systems. Throughout the years, models and tools have been developed to predict and control erosion in industries such as oil and gas production. However, these erosion models and erosion prediction tools have been mainly developed based on erosion data for much higher velocities and lower temperatures, i.e. the operating conditions for which the existing models have been built are not pertinent to those expected in CSP system. It is known that erosion depends on many factors such as material properties, erodent particle properties, and particle impact speed and angle. However, the effect of temperature on erosion is not vastly investigated. In this work, a temperature-based correlation is introduced that will be used to modify the existing erosion models to predict erosion rates at velocities and temperatures relevant to Gen3 CSP systems. The existing models are first validated against erosion experiments run at low temperatures and low velocities. Subsequently, a temperature correction term is developed that can extend the existing models to high temperatures, based on the available experimental data showing the effect of temperature on impact erosion. 2. Erosion Models. Continuing sequence of impacts from solid particles on surfaces would result in loss of material due to mechanical interaction between solid surface and particles. Erosion equations have been developed to predict erosion under different conditions and erosion mechanism, including cutting and deformation erosion. These models are mainly either mechanistic, empirical, and semi-mechanistic models, when the latter combine the theory of the erosion mechanism and particle motion with the available experimental data. One of the first empirical correlation was introduced by American Petroleum Institute (API) Recommended Practice (RP) 14E [1]. This correlation was very conservative, and several improved empirical and semi-mechanistic equations were developed in the years following. More recently, the models introduced by Erosion/Corrosion Research Center (E/CRC) at the University of Tulsa and Arabnejad. et al. [2] are frequently used in the literature and industry, as they account for many parameters affecting erosion including particle impact speed and angle, material density and hardness, and particle size and shape. However, both these models were developed based on data at relatively high velocities and also do not take into account any mechanical changes in material associated with thermal cycling at high temperatures. 3. Erosion Prediction at High Temperatures. In this work, the accuracy of Arabnejad et al. model and E/CRC model is investigated to predict impact erosion at conditions relevant to Gen3 CSP systems. Two significant deviations expected in Gen3 systems compared to operating conditions used to build these models are particle impact velocities and system temperature. As a first step, the performance of these models was validated at low velocities and temperatures. Impact erosion experiments were conducted on SS316 coupons using HSP 40/70 ceramic particles. Assuming particle rate of 1 kg/s/m, 0.0254 m of particle curtain thickness, and particle velocity of 1.5 m/s in the system, an overall erosion of 0.59 mm/year was calculated. The experimental results were subsequently compared to those from computational simulations and erosion of 0.47 mm/year was obtained using the Arabnejad et al. model. The results indicated that the models work well at low velocities and low temperature conditions. To account for temperature effect, a mathematical correlation was developed using data published by DUCOM [3] for Inconel 600 eroded by alumina particles at high velocities. The correlation was applied to both Arabnejad et. al model and the E/CRC model. The prediction results from these modified models were within 20% of this experimental data. Predictions of of erosion by the modified E/CRC model at three different temperatures are made. Similar to the calculation at low temperature, a typical CSP system with 1 kg/s/m of particle flow rate per unit length of the particle curtain and a curtain thickness of 0.0254 m is assumed. The annual thickness loss calculations were run for different particle impact velocities, assuming a uniform particle impact area equal to the cross-sectional area of the curtain (particle-particle interactions and dispersion of particles are not considered in obtaining the results). It is observed that erosion increases exponentially as temperature increases. Furthermore, it is also noted that, erosion changes non-linearly with impact velocity. Currently, experiments are also being conducted to measure erosion of SS316 at 800 ºC with HSP 40/70 particles at low impact velocities. We expect to use the results from high temperature testing to further improve the temperature correlation function. Similar models are also being developed for abrasion erosion resulting from particle sliding along the surfaces as well as attrition from particle to particle and particle to surface interactions. References. [1] Institute, A. P. (1991). API Recommended Practice for Design and Installation of Offshore Production Platform Piping System, API RP 14E. [2] Arabnejad, H., Mansouri, A., Shirazi, S. A., and McLaury, B. S. (2015a). Development of mechanistic erosion equation for solid particles. Wear, 332–333, 1044–1050. http://doi.org/10.1016/j.wear.2015.01.031. [3] https://ducom.com/high-temperature-erosion-evaluating-sample-wear/

14 SOLAR ENERGY↗

HPC Annual Report 2017

Sandia National Laboratories has a long history of significant contributions to the high performance community and industry. Our innovative computer architectures allowed the United States to become the first to break the teraFLOP barrier—propelling us to the international spotlight. Our advanced simulation and modeling capabilities have been integral in high consequence US operations such as Operation Burnt Frost. Strong partnerships with industry leaders, such as Cray, Inc. and Goodyear, have enabled them to leverage our high performance computing (HPC) capabilities to gain a tremendous competitive edge in the marketplace. As part of our continuing commitment to providing modern computing infrastructure and systems in support of Sandia missions, we made a major investment in expanding Building 725 to serve as the new home of HPC systems at Sandia. Work is expected to be completed in 2018 and will result in a modern facility of approximately 15,000 square feet of computer center space. The facility will be ready to house the newest National Nuclear Security Administration/Advanced Simulation and Computing (NNSA/ASC) Prototype platform being acquired by Sandia, with delivery in late 2019 or early 2020. This new system will enable continuing advances by Sandia science and engineering staff in the areas of operating system R&D, operation cost effectiveness (power and innovative cooling technologies), user environment and application code performance.

97 MATHEMATICS AND COMPUTING↗

Residential HVAC Fault Data Collection Plan – Refrigerant Undercharge and Overcharge Faults

Heating, ventilation, and air-conditioning (HVAC) systems can develop faults due to poor installation practices or gradual wear and tear, leading to decreased HVAC system’s efficiency, compromised thermal comfort, and shortened equipment lifespan (EERE, 2018). Automated fault detection and diagnosis (AFDD) technologies offer a solution by identifying energy-wasting HVAC faults, such as inadequate indoor airflow and incorrect refrigerant charge, and guiding technicians to enhance system efficiency. In the realm of residential HVAC, AFDD can be implemented through various fault detection and diagnosis capabilities, sensor configurations, and target applications. These technologies typically fall into three categories: smart diagnostic tools, original equipment manufacturer (OEM)-embedded tools, and add-on tools. Smart diagnostic tools employ temporarily installed sensors to directly measure HVAC system characteristics, while OEM-embedded tools utilize factory-installed sensors to identify faults or assess system performance. However, both these types of AFDD technologies are often only accessible for high-end HVAC equipment or require additional sensor installation by qualified technicians, resulting in high investment costs and limited applicability for low-income residential buildings. On the other hand, add-on tools rely solely on data from smart thermostats and meters to detect faults by continuously analyzing equipment runtime or energy usage. As smart thermostat and meter costs decrease and their prevalence increases, these tools can be readily deployed in low-income residential buildings. However, they possess limited capabilities as they rely solely on basic trend analysis. Enhancing such tools with advanced machine learning algorithms can significantly improve their effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Second-generation downscaled earth system model data using generative machine learning

The second-generation Sup3rCC dataset provides high-resolution meteorological data generated through the downscaling of multiple earth system models (ESMs) from the Coupled Model Intercomparison Project Phase 6 (CMIP6). This downscaling is performed through application of a generative machine learning approach called Super-Resolution for Renewable Resource Data (sup3r). This dataset builds on the first-generation Sup3rCC data by applying improved bias correction methods and adding downscaled precipitation to the output variables. As with the first Sup3rCC version, the data still include temperature, wind speed and direction at multiple heights, pressure, three components of downwelling solar radiation, and relative humidity—all at 4-kilometer (km) hourly resolution over the contiguous United States. This is a 25x spatial enhancement and 24x temporal enhancement of the source 100-km daily-average ESM data. This extension of the Sup3rCC dataset includes data from six ESMs from two shared socioeconomic pathways (SSPs) totaling 400 years of data with multiple future projections of changing meteorological conditions. The scenario selection was based on a structured evaluation of historical ESM skill and comprehensive representation of possible trajectories of future climate change in temperature, humidity, precipitation, solar irradiance, and near-surface wind speeds. The inclusion of multiple future projections is intended to enable users to assess key drivers of un 36 certainty and variability. All data are double-bias corrected, resulting in a product that can be used out-of-the-box for energy system analysis with minimal historical bias. The potential applications of Sup3rCC data extend to various topics in renewable energy resource assessment, energy systems modeling, and grid resilience studies. High-resolution future meteorological projections are critical for evaluating the effects of changing meteorological conditions on renewable energy generation, energy demand, and for optimizing energy storage and grid infrastructure. The 4-km hourly resolution of the downscaled data enables understanding of spatial and temporal variability at the scales necessary for energy system operational planning. In addition, the dataset can support risk assessments by providing detailed information on possible future extreme weather events and long-term meteorological variability at scales relevant to energy infrastructure. By offering an enhanced representation of possible future meteorological conditions, the second-generation Sup3rCC dataset enables more precise modeling of energy resilience and adaptation strategies in response to changing meteorological conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

Assessing the Effectiveness of Generalized Likelihood Ratio Test Detector Schemes in Seismic Event Detection and the Avoidance of Nontarget Signals

Cross-correlation techniques have played a long-standing and pivotal role in seismic event monitoring. However, the performance of correlation-based detectors is challenged by nuisance seismicity, or nontarget signals. Such detections are a problem when the mission is to automatically map events to the correct source region. Using aftershocks of the 2014 $M_w$ 6.0 South Napa, California, earthquake, we demonstrate the effectiveness of utilizing a dynamic correlation processor framework in a generalized likelihood ratio test (GLRT) detector configuration to minimize nontarget detections. A GLRT maximizes a detection statistic with respect to one or more unknown parameters. In this case, the detection statistic is a template signal match against the waveform in a window sliding over a data stream, and the unknown parameter is an index variable indicating group membership of the template event or events. Detected events are assigned to the event group that yields the largest detection statistic. In this work, our results show that a GLRT detector will outperform a suite of independently operating correlation and subspace detectors in terms of having a lower nontarget detection rate at a given missed detection rate. We also show that a GLRT detector composed of a few high-rank subspace detectors has a slightly higher nontarget detection rate, but a significantly lower missed detection rate, than a GLRT detector composed of many low-rank subspace detectors. The high-rank GLRT configuration produced impressive results even with marginal data (single channel, single station, and very low time bandwidth product), which bodes well for the utility of building efficient aftershock classification systems and global monitoring systems at larger scales. However, future work is required to assess performance at the regional scale and to assess the performance of the system at detecting target events not used in the detector template creation.

58 GEOSCIENCES↗

BETO 2021 Peer Review - Inverse Bioproduct Design Through Machine Learning and Molecular Simulation

This work aims to identify performance advantaged bioproducts (PABPs) through property prediction, which will guide experimental synthesis. The impact of this work will be faster market adoption of bioproducts with greater performance relative to incumbent products. We have identified >106 bioproduct candidates, but only some will have superior performance to create a market pull. High-throughput property prediction, enabled by machine learning, and elucidation of structure-function relationships, enabled by molecular simulation, provide a hypothesis driven approach for down selection of candidate biomolecules to pursue experimentally. To enable machine learning and molecular simulation for bioproduct discovery, automated structure generation and embedding must capture relevant features for prediction, databases must cover domains applicable to biobased products, and best practices for simulation of polymer systems must be developed. To address these challenges, we have established bioproduct relevant datasets, developed high-throughput polymer structure generation, and built end-to-end neural networks that have predicted 8 properties for >1.4 x 106 biopolymers. A molecular simulation pipeline for building, running, and analyzing polymers and polymer additives is being used to predict performance and develop design principles of biobased products. In collaboration with the PABP synthesis project, these computational tools are guiding synthesis and informing design of PABPs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building America Case Study: Energy Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates, Cocoa, Florida

In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grids, virtualization, and clouds at Fermilab

Fermilab supports a scientific program that includes experiments and scientists located across the globe. To better serve this community, in 2004, the (then) Computing Division undertook the strategy of placing all of the High Throughput Computing (HTC) resources in a Campus Grid known as FermiGrid, supported by common shared services. In 2007, the FermiGrid Services group deployed a service infrastructure that utilized Xen virtualization, LVS network routing and MySQL circular replication to deliver highly available services that offered significant performance, reliability and serviceability improvements. This deployment was further enhanced through the deployment of a distributed redundant network core architecture and the physical distribution of the systems that host the virtual machines across multiple buildings on the Fermilab Campus. In 2010, building on the experience pioneered by FermiGrid in delivering production services in a virtual infrastructure, the Computing Sector commissioned the FermiCloud, General Physics Computing Facility and Virtual Services projects to serve as platforms for support of scientific computing (FermiCloud 6 GPCF) and core computing (Virtual Services). Lastly, this work will present the evolution of the Fermilab Campus Grid, Virtualization and Cloud Computing infrastructure together with plans for the future.

97 MATHEMATICS AND COMPUTING↗

Final Project Report

This project pursued innovations to improve energy efficiency and indoor environmental quality (IEQ) in commercial and residential buildings. For commercial buildings, the project developed a testbed for “intelligent nested environmental systems technologies (iNEST),” which monitor and control energy flows and IEQ across a cascade of spaces from individuals’ desktops to office suites to floors to whole buildings. An iNEST testbed was constructed at Syracuse University and was used to assess the use of devices such as personal badges and CO2 sensors to study how reduced energy use and improved IEQ could be achieved. For residential buildings, resources were targeted in support of DoE’s Builders Challenge Program and to recruit Syracuse, NY builders. Three homes in Syracuse’s Near Westside neighborhood were also registered under the program by Syracuse University team, with an additional home registered by one of the builders. Findings from the work at the iNEST testbed facility, and results from other related projects were disseminated through Syracuse Center of Excellence in Environmental and Energy Systems (SyracuseCoE) 2008 Annual Symposium, the 9th International Healthy Buildings 2009 Conference & Exhibition, and through SyracuseCoE’s website and eNewsletters to inform the broader community of researchers, designers and builders. These public communication activities helped enhance the understanding of high performance buildings and facilitate further market acceptance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Super Energy Efficiency Design (S.E.E.D.) Home Evaluation

This report describes the results of evaluation by the Alliance for Residential Building Innovation (ARBI) Building America team of the 'Super Energy Efficient Design' (S.E.E.D) home, a 1,935 sq. ft., single-story spec home located in Tucson, AZ. This prototype design was developed with the goal of providing an exceptionally energy efficient yet affordable home and includes numerous aggressiveenergy features intended to significantly reduce heating and cooling loads such as structural insulated panel (SIP) walls and roof, high performance windows, an ERV, an air-to-water heat pump with mixed-mode radiant and forced air delivery, solar water heating, and rooftop PV. Source energy savings are estimated at 45% over the Building America B10 Benchmark. System commissioning, short termtesting, long term monitoring and detailed analysis of results was conducted to identify the performance attributes and cost effectiveness of the whole house measure package.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗