At least 433 records · Page 24

SCALE 6.2.4 Validation for Light Water Reactor Decay Heat Analysis

Energy release from the decay of radionuclides in nuclear fuel after its discharge from reactor is a critical parameter for design, safety, and licensing analyses of used nuclear fuel storage, transportation, and repository systems. Well-validated computational tools and nuclear data are essential for decay heat prediction. This paper summarizes the validation of the SCALE nuclear analysis code system version 6.2.4, used with ENDF/B-VII.1 libraries, for decay heat analysis of light water reactor used fuel. The experimental data used for validation include full-assembly decay heat measurements that cover assembly burnups of 5 to 51 GWd/tonne U, cooling times after discharge in the 2- to 27-year range, and initial fuel enrichments up to 4 wt% 235U. The comparison between calculated (C) and experimental (E) decay heat showed very good agreement, with an average C/E over all considered measurements of 1.006 (σ = 0.016) for pressurized water reactor and 0.984 (σ = 0.077) for boiling water reactor assembly measurements. The effect of using assembly-average versus axially varying modeling data on the calculated decay heat, important to thermal analyses for used fuel transportation and storage systems, is discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Applications of thermal energy storage to process heat storage and recovery in the paper and pulp industry

Applications of Thermal Energy Storage (TES) in a paper and pulp mill power house were studied as one approach to the transfer of steam production from fossil fuel boilers to waste fuel of (hog fuel) boilers. Data from specific mills were analyzed, and various TES concepts evaluated for application in the process steam supply system. Constant pressure and variable pressure steam accumulators were found to be the most attractive storage concepts for this application.

Carr, J. H.↗

A Multifaceted Analysis of Chemical-Absorption Heat Pump Technology for Integrated Energy Systems

Integrated Energy Systems (IES) research and development is essential for improving the economic usage of lowcarbon energy sources such as nuclear power, solar, and wind in the U.S. An ideal IES uses various energy sources and delivers energy to the power grid and industry as efficiently as possible. As part of this effort, there are many opportunities to use low-carbon energy for industries requiring process heat for production of many chemicals and fuels [1]. Currently, industries only have the option to burn CO2 emitting fuels or use resistance heaters for this process heat. Using resistance heaters is one way to electrify a process, allowing for low-carbon energy sources to be used, but is an inefficient method unless temperatures exceed 1000?C. Heat pumps have long been used to provide efficient heating or cooling by moving heat instead of generating it. More traditional heat pumps such as vapor compression heat pumps and absorption heat pumps are limited to temperatures below 300?C due to refrigerant and component material limits. However, chemical heat pumps have been investigated as an option for pumping heat at temperatures above 600?C [2], making the heat more applicable to many more chemical and fuel production processes.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗

Enthalpy By Energy Balance for Aerodynamic Heating Facility at NASA Ames Research Center Arc Jet Complex

The NASA Ames Research Center (ARC) Arc Jet Facilities' Aerodynamic Heating Facility (AHF) has been instrumented for the Enthalpy By Energy Balance (EB2) method. Diagnostic EB2 data is routinely taken for all AHF runs. This paper provides an overview of the EB2 method implemented in the AHF. The chief advantage of the AHF implementation over earlier versions is the non-intrusiveness of the instruments used. For example, to measure the change in cooling water temperature, thin film 1000 ohm Resistance Temperature Detectors (RTDs) are used with an Anderson Current Loop (ACL) as the signal conditioner. The ACL with 1000 ohm RTDs allows for very sensitive measurement of the increase in temperature (Delta T) of the cooling water to the arc heater, which is a critical element of the EB2 method. Cooling water flow rates are measured with non-intrusive ultrasonic flow meters.

Hightower, T. Mark↗

Thermodynamic analysis of alternate energy carriers, hydrogen and chemical heat pipes

Hydrogen and chemical heat pipes were proposed as methods of transporting energy from a primary energy source (nuclear, solar) to the user. In the chemical heat pipe system, primary energy is transformed into the energy of a reversible chemical reaction; the chemical species are then transmitted or stored until the energy is required. Analysis of thermochemical hydrogen schemes and chemical heat pipe systems on a second law efficiency or available work basis show that hydrogen is superior especially if the end use of the chemical heat pipe is electrical power.

Cox, K. E.↗

Experimental Investigation of a Phase Change Material Charged Serpentine Heat Exchanger with Louvered Fins

Phase change material heat exchangers (PCM-HX) can be used as a latent heat thermal energy storage (LHTES) component in heat pump applications to further enhance the efficiency of a heat pump as well as to yield financial savings by peak-load shifting. In this paper, a low-cost commercially available aluminum serpentine heat exchanger with louvered fins was experimentally investigated to check its thermal performance as a PCM-HX. A transparent rectangular box fabricated from acrylic plates served as a PCM container. Two cameras were used to capture the phase change process of the PCM on the front and top sides of the container during the experiment. A total of 88 installed temperature sensors throughout the test setup and a mass flow meter enabled a quantitative analysis of the PCM-HX as well. The energy balance deviation between the estimated theoretical and experimentally calculated PCM storage was ±14% considering the often-neglected heat loss and thermal mass of the PCM-HX. PCM temperature profiles, charge and discharge rates, and energy densities under different test conditions were also investigated.

42 ENGINEERING↗

Sand-Based Thermal Storage for Building Heating Applications: A District Energy Case Study

Buildings account for 40% of global energy consumption and contribute to 30% of global carbon emissions. As energy from renewable sources increases in availability and building designers push for increased electrification, thermal energy storage (TES) systems will play a crucial role in extending the usable time horizon of renewable energy. While water, molten salt, and phase change materials are typically used for building TES heating applications, silica-sand has emerged as an alternative medium for concentrated solar power applications due to its low cost, wide availability, and comparable system efficiency. This paper proposes a new silica-sand particle-based TES system for building heating applications. In this work, a novel steam plant for district heating applications is first designed to utilize silica-sand TES, which can be used for different district energy systems. To demonstrate the silica-sand TES plant performance, the design is modelled in Modelica based on a case study on the University of Colorado Boulder’s campus. The simulation results show that the sand TES plant is more costly to operate than a gas-boiler based plant due to the low cost of natural gas, while the site EUI and carbon intensity can be improved. This novel system shows initial promise as a low-carbon alternative to conventional natural gas steam boilers but will require further modelling and follow-up research to improve its energy efficiency. An eventual rise in natural gas prices, and reduction of electricity prices, could improve the economic viability of this system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic optimization with flexible heat integration of a solar parabolic trough collector plant with thermal energy storage used for industrial process heat

There is an increasing need to reduce fossil fuel consumption used for industrial process heat to slow the effects of climate change. Using solar thermal heat is a viable way to replace fossil fuel use, but solar industrial process heat plants have limited implementation due to large upfront costs and inefficiencies from the inherent variability from solar energy. Having more flexible and optimized control over these plants can enable them to be more efficient. Here in this work, a solar industrial process heat plant with thermal energy storage that can flexibly collect and deliver heat to two industrial processes (flexible heat integration) is dynamically modeled with control setpoints found by a dynamic optimization method. The optimized case can increase the solar efficiency of the plant by 7.5% on average relative to a base case. The results show that it is best to collect heat at lower temperatures for all but ideal solar conditions, only medium to high quality heat should be stored in large quantities, and exchanging heat with a lower temperature heat sink is generally more efficient. The optimized case is able to reduce the levelized cost of heat of the plant to $31.83/MWh th compared to a base case value of $34.10/MWh th . The optimized case can reduce emissions by 22.2% compared to a plant which uses only natural gas. This work shows that dynamic optimization with flexible heat integration can be a cost-effective way to increase efficiency so that more of these types of plants can be implemented.

14 SOLAR ENERGY↗

Heat Pumps and the Electrification of Heating

70 to 80% of building energy load in Alaska is heating. About 81% of residential heating is supplied via on-site combustion of fossil fuels. How can heat pumps provide heat energy from renewable sources?

Alaska↗

Heat pipe solar receiver with thermal energy storage

An HPSR Stirling engine generator system featuring latent heat thermal energy storge, excellent thermal stability and self regulating, effective thermal transport at low system delta T is described. The system was supported by component technology testing of heat pipes and of thermal storage and energy transport models which define the expected performance of the system. Preliminary and detailed design efforts were completed and manufacturing of HPSR components has begun.

Zimmerman, W. F.↗

Baltimore Energy & Infrastructure: Assessing Urban Heat Vulnerability in Baltimore Neighborhoods to Inform Transportation Resiliency Planning Efforts

Across the world, climate change is altering cities and their local climate systems. Following global trends of rising mean temperatures, Baltimore, Maryland is projected to experience more frequent extreme heat events. Exacerbated by Urban Heat Island (UHI) effects, residents of the city face high temperatures from limited tree canopy, highly paved and impervious surfaces, limited air flow, and high concentrations of localized emissions. Urban heat is dispersed asymmetrically, with historically marginalized populations experiencing disproportionately severe heat. Recognizing the impacts of extreme urban heat, the Maryland Transit Administration (MTA) collaborated with us, the Spring 2024 Goddard Energy and Infrastructure NASA DEVELOP team to assess urban impacts of MTA users and assets and explore opportunities to enhance resiliency planning. We evaluated the feasibility of NASA Earth observations (EOs) in visualizing heat vulnerability in Baltimore City and County. We mapped UHI and extreme heat using remote sensing observations, tailored a Heat Priority Score (HPS) to analyze heat data in tandem with socioeconomic data from American Community Survey (ACS), and utilized SOlar and LongWave Environmental Irradiance Geometry (SOLWEIG) model to estimate MTA riders’ thermal comfort. NASA EOs served to quantify the distribution and severity of extreme heat at the block group level, which was found to correlate with a lack of vegetation and presence of densely built-up surroundings. The HPS revealed that extreme heat events most negatively impact communities that exhibit social vulnerability through indicators such as age, race, and income. These findings will inform neighborhood resiliency plans for the MTA that can be incorporated into their Adaptation Resiliency Toolbox (ART).

Baltimore,↗

HePHAESTUS: Heat Pipe Heterogeneous Approximation of Energy and Navier-Stokes Equations, Transience, and Non-Uniform Surface Heating [Slides]

A heat pipe is a liquid/vapor filled metal pipe capable of transporting large amounts of heat through evaporation of a liquid at one end and condensation of vapor at the other end creating a closed fluid loop. Heat pipes are widely used in the cooling of electronics and in space applications. Heat pipes are typically composed of a pipe wall, a wick material, a working fluid, and a central vapor channel. Heat is transferred into the working fluid at the “evaporator” end, through an adiabatic section, and heat is removed at the opposite end at the “condenser.” If no wick is used, gravitational acceleration can circulate the fluid due to the buoyancy of the vapor in the central core and a falling film of liquid at the pipe wall forming a “thermosyphon."

42 ENGINEERING↗

Microgravity fluid management requirements of advanced solar dynamic power systems

The advanced solar dynamic system (ASDS) program is aimed at developing the technology for highly efficient, lightweight space power systems. The approach is to evaluate Stirling, Brayton and liquid metal Rankine power conversion systems (PCS) over the temperature range of 1025 to 1400K, identify the critical technologies and develop these technologies. Microgravity fluid management technology is required in several areas of this program, namely, thermal energy storage (TES), heat pipe applications and liquid metal, two phase flow Rankine systems. Utilization of the heat of fusion of phase change materials offers potential for smaller, lighter TES systems. The candidate TES materials exhibit large volume change with the phase change. The heat pipe is an energy dense heat transfer device. A high temperature application may transfer heat from the solar receiver to the PCS working fluid and/or TES. A low temperature application may transfer waste heat from the PCS to the radiator. The liquid metal Rankine PCS requires management of the boiling/condensing process typical of two phase flow systems.

Migra, Robert P.↗

Optimize heat prosumers' economic performance under current heating price models by using water tank thermal energy storage

Due to heat prosumers' dual roles of heat producer and heat consumer, the future district heating (DH) systems will become more flexible and competitive. However, the current heating price models have not yet supported the reverse heat supply from prosumers to the central DH system, which means the prosumers would gain no economic benefit from supplying heat to the central DH system. These unidirectional heating price models will reduce interest in prosumers, and thus hinder the promotion of prosumers in DH systems. This study aimed to optimize prosumers' economic performance under the current heating price models by introducing water tank thermal energy storage (WTTES). A dynamic optimization problem was formulated to explore prosumers' economic potentials. The size parameter of WTTESs was swept in prosumers to obtain the optimal storage size considering the trade-off between the payback period and the heating cost saving. The proposed method was tested on a campus DH system in Norway. The results showed that the prosumer's annual heating cost was saved up to 9%, and the investment of WTTES could be recovered in less than ten years. This study could provide guidelines on improving prosumers' economic performance and promote the development of prosumers during the transformation period of DH systems.

Li, H↗

The partition of energy associated with tropical heat sources

Data sets derived from observations during the First GARP Global Experiment (FGGE) have permitted the study of the behavior of the tropical atmosphere to an extent not possible before. The present summary discusses characteristics of the tropical atmosphere which may be a result of tropical heating. It is shown that the meridional component of the divergent wind is of the same order of magnitude an he rotational meridional wind for the planetary tropical scales. Furthermore, the first and second internal modes dominate over most of the tropics, and it is shown that gravity and Kelvin codes are the main contributors to the total tropical divergence. Comparison with averaged station precipitation data and heating estimates obtained from Goddard Laboratory for Atmospheric Science (GLAS)/National Aeronautics and Space Administration (NASA) show good correspondence between areas with maximum internal mode energy and regions with pronounced latent heat release.