Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Provably-Stable Overload Ride-Through Control for Grid-Forming Inverters Using System-Wide Lyapunov Function Analysis

A key challenge associated with a grid-forming (GFM) inverter based resource (IBR) is its behavior during severe grid disturbances: since a GFM inverter regulates voltage in the fast timescale instead of current or power, it may experience a transient overload of current, power and/or energy during a severe grid disturbance. While many promising control strategies for overload ride-through have been proposed over the past two decades, transient stability of the system during and after the transition to an overload ride-through control mode remains difficult to guarantee. In this work, a novel overload ride-through control strategy is proposed for a system of grid-forming inverters that takes both self-protection and system-wide transient stability into account. A proposed system-level supervisory control uses slow communication to pre-emptively assign a set of local ride through control parameters to individual GFM IBR, including a current-limiting virtual reactance, that guarantees that synchronism is still preserved for any set of anticipated grid disturbances. At the core of the supervisory control lies a Lyapunov-function-based routine capable of establishing a strong, albeit conservative, transient stability guarantee for the system. Here, the proposed overload ride-through control strategy is validated via numerical integration of a reduced-order model, as well as through detailed electromagnetic transient (EMT) simulation.

30 DIRECT ENERGY CONVERSION↗

Grid Forming Control Tuning for a Hybrid Inverter-Based Resource Power Plant

A hybrid inverter-based resource (IBR) power plant consists of grid-following (GFL) and grid-forming inverter-based resources (GFM-IBR) connected in parallel. Here, this research focuses on how to design and tune GFM's control parameters to ensure stable operation of the hybrid power plant for weak and strong grid conditions. We consider two design cases: one where the GFL-IBR does not provide frequency support, and one where it does. It is found that the GFM's power-frequency synchronizing system can lose stability when the power-frequency droop constant is large and/or the grid is strong. Additionally, if the GFL has its frequency support enabled, oscillation stability worsens. To explain the mechanism of the interactions, we construct a feedback system for the synchronizing loop, which consists of the GFM's power-frequency droop control that generates the GFM's synchronizing angle, the GFL's phase-locked loop that measures the voltage phase angle, the GFL's frequency-power control that generates its power order, and the rest of the system. The feedback system is effective in illustrating the potential stability risks. Successful design ensures that the hybrid power plant can operate smoothly and ride through grid disturbances.

feedback systems↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

27 ARPA - Advanced Research Projects Agency-Energy↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters: Preprint

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

A systematic solution to quantify economic values of vehicle grid integration

We report Vehicle-Grid-Integration (VGI) supplies one of the potential benefit extensions for electric vehicles (EVs) to make use of their parking time, which enables the EVs to provide grid services while still meeting consumer driving needs. However, the costs, benefits and risks of VGI still remain unclear, which limits the development of the VGI to promote the interaction between the EV and grid. In this study, we propose an integrated framework to quantify and utilize the aggregate flexibility of the EVs to supply the grid services in electricity markets. The integrated solution includes five sub-modules that cover end-to-end functionalities from individual EV energy consumption estimation to final monetary values calculation of providing grid services. Both wholesale market and local level charging management are formulated in the optimization module. A predictive control algorithm is proposed to allocate power to individual vehicles in real time, considering uncertainties from dispatch signal and travel behavior. Simulation results from 10,000 EVs indicate that the proposed optimization methods can significantly reduce the system cost in both wholesale market and retail market. Local tariff optimization reduces the electricity cost by 24.4% compared to uncontrolled charging. Wholesale market optimization results show that $\$$691 and $\$$255 revenues can be captured by each EV in ERCOT and CAISO markets per year, although with a conservative assumption on battery throughput cost at 0.16$\$$/kWh.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A techno-economic assessment framework for hydrogen energy storage toward multiple energy delivery pathways and grid services

Hydrogen energy storage (HES) transforms and stores electric energy from the grid into hydrogen, and supplements other energy storage and demand response resources in addressing challenges in renewable-intensive power systems. Understanding how to optimally utilize an HES system to maximize its economic benefits from stacked value streams is highly important to its development and deployment. Here, in this paper, we present a techno-economic assessment framework for an HES system considering three common energy delivery pathways and multiple grid and end-user services. Models are developed to capture the operational capability, flexibility, and constraints associated with hydrogen production, compression, storage, and utilization as well as different grid services in an economic assessment. To define the technically achievable benefits, an optimal dispatch formulation is proposed to maximize the economic benefits over a representative year with an hourly time step considering the trade-offs among different value streams. Representative case studies are designed and carried out to show how system configuration, energy delivery pathways, and grid services may affect economic benefits. It was found that value streams from bundling grid services account for up to 76% of the total benefits and are critical for an HES project to be financially viable.

25 ENERGY STORAGE↗

Automatic voltage regulation application for PV inverters in low-voltage distribution grids – A digital twin approach

This paper proposes a hierarchical coordinated control strategy for PV inverters to keep voltages in low-voltage (LV) distribution grids within specified limits. The top layer of the proposed architecture consists of the designed automatic voltage regulation (AVR) application, which has access to voltage measurements and grid parameters from the LV distribution grid, both current and historical. The AVR application solves a constrained optimization problem, which provides a set of local control set-points that bring the voltage across the grid within bounds. The middle layer consists of a local Volt/VAR controller, which is adjusted by the AVR app, while the bottom layer is the inner-loop controller of the PV inverter. The proposed method not only improves the voltage quality in the grid but also manages the reactive power outputs of PV inverters efficiently. Further, a digital twin of the cyber-physical system has also been employed that interacts with the control system to ensure its appropriate operation. The effectiveness of the proposed methodology is demonstrated on a representative low-voltage feeder located in Denmark.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid impact analysis using controller-hardware-in-the-loop for high-power vehicle charging stations

A controller-hardware-in-the-loop (CHIL) architecture for the evaluation of grid impacts arising from high-power vehicle charging stations is presented in this paper. Unlike simulation-based studies, the proposed method can be used to capture the interactions of the grid and the charging load along with charger controllers in real time. The proposed method can be used to evaluate the impact of charging load on the grid in terms of voltage variations and line congestion. The proposed CHIL platform allows for de-risking the vehicle charging station deployment by simulating the complex interactions among all the components of a vehicle charging station - i.e., the grid, vehicle, and charger controller - in a realistic manner before using the charging station in a grid. Further, the proposed CHIL approach can be used to evaluate the voltage regulation causalities of the vehicle charging station. Experimental results are presented in the paper to illustrate the applicability of the proposed method in a laboratory environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing a decentralized fault-tolerant software framework for smart grids and its applications

The vision of the ‘Smart Grid’ anticipates a distributed real-time embedded system that implements various monitoring and control functions. As the reliability of the power grid is critical to modern society, the software supporting the grid must support fault tolerance and resilience of the resulting cyber-physical system. This paper describes the fault-tolerance features of a software framework called Resilient Information Architecture Platform for Smart Grid (RIAPS). The framework supports various mechanisms for fault detection and mitigation and works in concert with the applications that implement the grid-specific functions. The paper discusses the design philosophy for and the implementation of the fault tolerance features and presents an application example to show how it can be used to build highly resilient systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Autoclave grid-to-rod fretting wear evaluation of a candidate cladding coating for accident-tolerant fuel

In pressurized water reactors (PWRs), water flow induced vibrations cause contact and rubbing between the fuel rods and the supporting grid, a phenomenon known as Grid-to-Rod-Fretting (GTRF). GTRF may produce progressive wear damage on the fuel claddings leading to subsequent leakage of radioactive fission products. Various accident-tolerant fuel (ATF) concepts are being developed for higher resistance to the high temperature steam and one approach is to apply a cladding coating. Here, fretting wear behavior of a candidate Cr-coating was investigated using a unique bench-scale autoclave testing rig mimicking the environment in an industrial full-assembly PWR simulator. The contact was under a realistically low load (~0.5 N) lubricated by deionized water at a temperature of 204 °C under a pressure of 20-23 bars. Results demonstrated that the Cr-coating significantly improved the cladding's wear resistance when tested against a commercial ZIRLO grid with or without pre-oxidization. In addition, the Cr-coating also reduced wear on the non-oxidized ZIRLO grid but slightly increased the wear on the pre-oxidized grid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fundamentals of Using Cracked Film Lithography to Pattern Transparent Conductive Metal Grids for Photovoltaics

The fundamentals of using cracked film lithography (CFL) to fabricate metal grids for transparent contacts in solar cells were studied. The underlying physics of drying-induced cracks were well-predicted by an empirical correlation relating crack spacing to capillary pressure. CFL is primarily controlled by varying the crack template thickness, which establishes a three-way tradeoff between the areal density of cracks, crack width, and spacing between cracks, which in turn determine final grid transmittance, grid sheet resistance, and the semiconductor resistance for a given solar cell. Since CFL uses a lift-off process, an additional constraint is that the metal thickness must be less than 1/3 of the crack template thickness. Furthermore, the transmittance/grid sheet resistance/wire spacing tradeoffs measured in this work were used to calculate solar cell performance: CFL-patterned grids should outperform screen-printed grids for narrow cells (0.5–2 cm wide) and/or cells with high semiconductor sheet resistance (=100 O/sq), making CFL attractive for monolithically integrated thin-film photovoltaic modules.

14 SOLAR ENERGY↗

Simulating Sea-Ice Deformation in Viscous-Plastic Sea-Ice Models With CD-Grids

Linear kinematic features (LKFs) are found everywhere in the Arctic sea-ice cover. They are strongly localized deformations often associated with the formation of leads and pressure ridges. In viscous-plastic (VP) sea-ice models, the simulation of LKFs depends on several factors such as the grid resolution, the numerical solver convergence, and the placement of the variables on the mesh. In this study, we compare two recently proposed discretization with a CD-grid placement with respect to their ability to reproduce LKFs. The first (CD1) is based on a nonconforming finite element discretization, whereas the second (CD2) uses a conforming subgrid discretization. To analyze their resolution properties, we evaluate runs from different models (e.g., FESOM, MPAS) on a benchmark problem using quadrilateral, hexagonal and triangular meshes. Our findings show that the CD1 setup simulates more deformation structure than the CD2 setup. This highlights the importance of the type of spatial discretization for the simulation of LKFs. Due to the higher number of degrees of freedom, both CD-grids resolve more LKFs than traditional A, B, and C-grids at fixed mesh level. This is an advantage of the CD-grid approach, as high spatial mesh resolution is needed in VP sea-ice models to simulate LKFs.

54 ENVIRONMENTAL SCIENCES↗

A multi-scale time-series dataset with benchmark for machine learning in decarbonized energy grids

The electric grid is a key enabling infrastructure for the ambitious transition towards carbon neutrality as we grapple with climate change. With deepening penetration of renewable resources, the reliable operation of the electric grid becomes increasingly challenging. In this paper, we present PSML, a first-of-its-kind open-access multi-scale time-series dataset, to aid in the development of data-driven machine learning (ML)-based approaches towards reliable operation of future electric grids. The dataset is synthesized from a joint transmission and distribution electric grid to capture the increasingly important interactions and uncertainties of the grid dynamics, containing power, voltage and current measurements over multiple spatio-temporal scales. Using PSML, we provide state-of-the-art ML benchmarks on three challenging use cases of critical importance to achieve: (i) early detection, accurate classification and localization of dynamic disturbances; (ii) robust hierarchical forecasting of load and renewable energy; and (iii) realistic synthetic generation of physical-law-constrained measurements. We envision that this dataset will provide use-inspired ML research in safety-critical systems, while simultaneously enabling ML researchers to contribute towards decarbonization of energy sectors.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of daily gridded climate products using in situ FLUXNET data and tree growth modeling

Gridded climate data products have facilitated research in climate and ecology by providing meteorological data continuously across large spatial scales. However, the sensitivity of scientific outcomes to dataset choice remains poorly understood, and evaluation using station-based records can favor datasets built heavily on weather stations. Here, we evaluate seven high-resolution daily gridded datasets covering the contiguous United States using independent meteorology from the FLUXNET2015 dataset, with a focus on the implications of dataset choice for process-based tree growth modeling. We find that gridded products tend to capture temperature accurately while consistently overestimating the magnitude and frequency of precipitation and its extremes. Moreover, datasets vary in how they define a ‘day,’ which significantly affects temporal alignment with FLUXNET2015 observations. Despite differences among the datasets, the interannual variability in tree ring simulations is insensitive to dataset choice, likely because daily-scale biases are averaged out through accumulated growth across several months. However, inaccuracies in temperature and precipitation can significantly bias modeled xylem cell production, with systematically higher annual precipitation in the gridded datasets leading to greater xylem production compared to simulations using in situ data. Our results suggest that model applications, especially those that integrate to time scales longer than one day, are likely insensitive to climate dataset choice, but applications that are sensitive to daily climate variations or to absolute climate values need to carefully consider biases in gridded climate products.

54 ENVIRONMENTAL SCIENCES↗

Grid-forming Control of Single- and Two-Stage Solar PV Systems with Mode Transition

Legacy power systems once dominated by con-ventional synchronous machines are transitioning into systems driven by fast-acting power-electronic converters that integrate renewable resources. The majority of integrated renewables such as PV and wind bring down system inertia and can cause stability issues due to their volatile nature. The state-of-the-art grid-forming (GFM) control is proven to enhance system inertia and stability in low-inertia systems. However, most of the existing GFM inverters are applied for battery systems, which are much more expensive than PV. Motivated by this, in this paper we propose a holistic grid-forming (GFM) control strategy for PV systems without the need of energy storage. The proposed strategy is developed on the secondary level of the grid-forming control that enables the PV inverter to operate smoothly among islanded, synchronization, GFM, and limited grid-forming (LGF) modes. The practical criteria for determining the operation modes are established and implemented based on the grid operation scenarios. Here, the proposed design is successfully validated by case studies with a laboratory prototype using Siemens Software Defined Inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modified Andronov-Hopf Oscillator-Based Grid-Forming Converter with Emulated Virtual Cable for Enhanced Power Sharing Performance

Nonlinear oscillator-based grid-forming converters offer superior dynamic and steady-state performance, making them an attractive solution for interconnecting renewable resources. This paper proposes a novel modified Andronov-Hopf oscillator to enhance the operating spectrum and facilitate the integration of renewable energy sources. An inner loop controller based on the Lyapunov energy function is implemented to achieve robust stability and performance, while a virtual cable emulation strategy enables seamless parallel operation. Comprehensive modeling and simulation studies validate the effectiveness of the proposed system, demonstrating its capabilities in addressing diverse operating scenarios, including grid faults, renewable energy fluctuations, and parallel operation. The proposed solution exhibits fast transient response, robust stability, and flexible operation, making it a valuable contribution to the field of renewable energy integration. The results of this study can be used to inform the design and implementation of next-generation grid-forming converters, enabling a more sustainable and reliable energy future. Additionally, the proposed system's ability to operate in both grid-connected and islanded modes makes it an ideal candidate for remote and off-grid renewable energy applications. The proposed solution's scalability and modularity also make it suitable for large-scale renewable energy integration. The proposed system is verified through MATLAB/Simulink and PLECS simulations, demonstrating its effectiveness in ensuring robust and efficient operation.

Andronov-Hopf Oscillator (AHO)↗

Power Converter Topologies for Electrolyzer Applications to Enable Electric Grid Services

Hydrogen electrolyzers, with their operational flexibility, can be configured as smart dynamic loads which can provide grid services and facilitate the integration of more renewable energy sources into the electrical grid. However, to enable this ability, the electrolyzer system should be able to control both active and reactive power in coordination with the low-level controller of the electrolyzer via the power electronics system interface between the utility grid and electrolyzer. This paper discusses power converter topologies and the control scheme of this power electronics interface for electrolyzer applications to enable electricity grid services. For the sake of unity, in this paper, we consider the power converter system interfacing the utility grid at the line-to-line root mean square (RMS) value of 480 VAC-60 Hz and supplying to the 3500 A-750 kW PEM electrolyzer stack.

electrolyzer↗