Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geant4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Measurement of the muon-induced neutron yield in liquid scintillator and stainless steel at LNGS with the LVD experiment

We describe the measurement of the muon-induced neutron yield in liquid scintillator and stainless steel (SS) at the Gran Sasso National Laboratory (LNGS), with the LVD experiment. The Large Volume Detector (LVD) is located in Hall A of the LNGS and is made of 1000 t of liquid scintillator and 1000 t of SS. Using an independent measurement to evaluate the background and with the support of a full Monte Carlo simulation based on Geant4, we measured a neutron yield of (2.9±0.6)×10{sup −4} and (1.5±0.3)×10{sup −3} in liquid scintillator and in stainless steel, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The multi-scattering model for calculations of positron spatial distribution in the multilayer stacks, useful for conventional positron measurements

The spatial distribution of positrons emitted from radioactive isotopes into stacks or layered samples is a subject of the presented report. It was found that Monte Carlo (MC) simulations using GEANT4 code are not able to describe correctly the experimental data of the positron fractions in stacks. The mathematical model was proposed for calculations of the implantation profile or positron fractions in separated layers or foils being components of a stack. The model takes into account only two processes, i.e., the positron absorption and backscattering at interfaces. The mathematical formulas were applied in the computer program called LYS-1 (layers profile analysis). The theoretical predictions of the model were in the good agreement with the results of the MC simulations for the semi infinite sample. The experimental verifications of the model were performed on the symmetrical and non-symmetrical stacks of different foils. The good agreement between the experimental and calculated fractions of positrons in components of a stack was achieved. Also the experimental implantation profile obtained using the depth scanning of positron implantation technique is very well described by the theoretical profile obtained within the proposed model. The LYS-1 program allows us also to calculate the fraction of positrons which annihilate in the source, which can be useful in the positron spectroscopy.

97 MATHEMATICS AND COMPUTING↗

Measurement of the weak charge of the carbon-12 nucleus within the P2 experiment in Mainz

The P2 experiment at the MESA facility in Mainz aims to make a high precision measurement of the weak charge of the proton, and a suitable experimental setup is currently being designed [1]. As high precision measurements of the weak charges of different particles and nuclei are differently sensitive to physics beyond the Standard Model in the form of new quantum loop correction parameters, experiments with a range of different target materials are complementary. We introduce first feasibility considerations for the determination of the Weak Mixing Angle via the scattering of electrons from carbon nuclei in a graphite target with the P2 detector setup. In order to make an estimate of the achievable precision we present analytic calculations as well as Monte-Carlo simulations. The results of Geant4 simulations of proposed experimental setups are included.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The “accumulation effect” of positrons in the stack of foils, detected by measurements of the positron implantation profile

The profiles of positrons implanted from the radioactive source {sup 22}Na into a stack of foils and plates are the subject of our experimental and theoretical studies. The measurements were performed using the depth scanning of positron implantation profile method, and the theoretical calculations using the phenomenological multi-scattering model (MSM). Several stacks consisting of silver, gold and aluminum foils, and titanium and germanium plates were investigated. We notice that the MSM describes well the experimental profiles; however when the stack consisting of silver and gold foils, the backscattering and linear absorption coefficients differ significantly from those reported in the literature. We suggest the energy dependency of the backscattering coefficient for silver and gold. In the stacks which comprise titanium and germanium plates, there were observed the features, which indicate the presence of the “accumulation effect” in the experimental implantation profile. This effect was previously detected in implantation profiles in Monte Carlo simulations using the GEANT4 tool kit, and it consists in higher localization of positrons close the interface. We suppose that this effect can be essential for positron annihilation in any heterogeneous materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the energy, multiplicity and angular correlation of γ-rays from the thermal neutron capture reaction Gd(n, γ) using JPARC-ANNRI

We conducted an experiment using the JPARC-ANNRI spectrometer to measure the energy, multiplicity and correlation of γ-rays from the neutron capture of natural gadolinium. We incorporated the GEANT4 Monte Carlo (MC) simulation into the detector, and compared the data with the results of the MC simulation. We report our data analysis and compare our data with those obtained by the MC simulation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Upgrades of imaging x-ray crystal spectrometers for high-resolution and high-temperature plasma diagnostics on EAST

Upgrade of the imaging X-ray crystal spectrometers continues in order to fulfill the high-performance diagnostics requirements on EAST. For the tangential spectrometer, a new large pixelated two-dimensional detector was deployed on tokamaks for time-resolved X-ray imaging. This vacuum-compatible detector has an area of 83.8 × 325.3 mm{sup 2}, a framing rate over 150 Hz, and water-cooling capability for long-pulse discharges. To effectively extend the temperature limit, a double-crystal assembly was designed to replace the previous single crystals for He-like argon line measurement. The tangential spectrometer employed two crystal slices attached to a common substrate and part of He- and H-like Ar spectra could be recorded on the same detector when crystals were chosen to have similar Bragg angles. This setup cannot only extend the measurable Te up to 10 keV in the core region, but also extend the spatial coverage since He-like argon ions will be present in the outer plasma region. Similarly, crystal slices for He-like iron and argon spectra were adopted on the poloidal spectrometer. Wavelength calibration for absolute rotation velocity measurement will be studied using cadmium characteristic L-shell X-ray lines excited by plasma radiation. A Cd foil is placed before the crystal and can be inserted and retracted for in situ wavelength calibration. The Geant4 code was used to estimate X-ray fluorescence yield and optimize the thickness of the foil.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte-Carlo simulation of noise in hard X-ray Transmission Crystal Spectrometers: Identification of contributors to the background noise and shielding optimization

Transmission crystal spectrometers (TCS) are used on many laser facilities to record hard X-ray spectra. During experiments, signal recorded on imaging plates is often degraded by a background noise. Monte-Carlo simulations made with the code GEANT4 show that this background noise is mainly generated by diffusion of MeV electrons and very hard X-rays. An experiment, carried out at LULI2000, confirmed that the use of magnets in front of the diagnostic, that bent the electron trajectories, reduces significantly this background. The new spectrometer SPECTIX (Spectromètre PETAL à Cristal en TransmIssion X), built for the LMJ/PETAL facility, will include this optimized shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of a Bonner sphere spectrometer for application to the determination of neutron field in the Experimental Advanced Superconducting Tokamak experimental hall

To assess the neutron energy spectra and the neutron dose for different positions around the Experimental Advanced Superconducting Tokamak (EAST) device, a Bonner Sphere Spectrometer (BSS) was developed at Peking University, with totally nine polyethylene spheres and a SP9 {sup 3}He counter. The response functions of the BSS were calculated by the Monte Carlo codes MCNP and GEANT4 with dedicated models, and good agreement was found between these two codes. A feasibility study was carried out with a simulated neutron energy spectrum around EAST, and the simulated “experimental” result of each sphere was obtained by calculating the response with MCNP, which used the simulated neutron energy spectrum as the input spectrum. With the deconvolution of the “experimental” measurement, the neutron energy spectrum was retrieved and compared with the preset one. Good consistence was found which offers confidence for the application of the BSS system for dose and spectrum measurements around a fusion device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Positron production at extreme light infrastructure – nuclear physics (ELI-NP)

Applied and material physics studies with positron beams of Fermi–surfaces, defects, interfaces etc. offer excellent diagnostics tools. At ELI-NP, an intense γ beam of about 10{sup 11} photons/s with energies up to 3.5 MeV will be used to generate a positron beam via pair production in a tungsten converter target. To obtain a high intensity beam of moderated positrons the design of the positron source is of high importance. The design of a dedicated positron source at ELI–NP is being investigated based on extensive GEANT4 simulations. The goal of the simulations is to optimize the geometry of the target and the gamma beam collimation. We present here the characteristics of the positron beam obtained for different geometries of the converter target.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cosmic rays muon flux measurements at Belgrade shallow underground laboratory

The Belgrade underground laboratory is a shallow underground one, at 25 meters of water equivalent. It is dedicated to low-background spectroscopy and cosmic rays measurement. Its uniqueness is that it is composed of two parts, one above ground, the other bellow with identical sets of detectors and analyzing electronics thus creating opportunity to monitor simultaneously muon flux and ambient radiation. We investigate the possibility of utilizing measurements at the shallow depth for the study of muons, processes to which these muons are sensitive and processes induced by cosmic rays muons. For this purpose a series of simulations of muon generation and propagation is done, based on the CORSIKA air shower simulation package and GEANT4. Results show good agreement with other laboratories and cosmic rays stations.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing the emission, propagation, and focusing of an intense electron beam

Intense electron beams can be used to study the dynamical response of materials under shocks in order to adjust the models developed for hydrodynamics simulations. We present in this paper a characterization of beams produced in a field emission diode coupled to the generator RKA at CEA/CESTA. Cherenkov emission, produced by the beam interacting in a fused silica disk, was observed by fast optical cameras to estimate beam homogeneity. GEANT4 simulations were performed to estimate the transfer function of the silica target and to optimize the anode foil. First, we chose the best cathode material available among the most common materials used in field emission systems. In addition, we found that by optimization of the anode thickness, we could improve the spatial homogeneity of the beam which is of prime importance for computing the interaction of the beam with materials. Next, we changed the beam fluence by increasing the beam current and by reducing the beam radius. Finally, we studied the propagation and focusing of the electron beam in low pressure gases and observed that we could use self-magnetic field focusing in order to increase beam fluence at the target location. The experimental results are in good agreement with PIC simulations.

43 PARTICLE ACCELERATORS↗

On LBNE neutrino flux systematic uncertainties

The systematic uncertainties in the neutrino flux of the Long-Baseline Neutrino Experiment, due to alignment uncertanties and tolerances of the neutrino beamline components, are estimated. In particular residual systematics are evaluated in the determination of the neutrino flux at the far detector, assuming that the experiment will be equipped with a near detector with the same target material of the far detector, thereby canceling most of the uncertainties from hadroproduction and neutrino cross sections. This calculation is based on a detailed Geant4-based model of the neutrino beam line that includes the target, two focusing horns, the decay pipe and ancillary items, such as shielding.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic stopping cell for photofission fragments at the ELI-NP facility

The brilliant gamma beam at the future Extreme Light Infrastructure - Nuclear Physics (ELI-NP) facility will be used to generate a beam of exotic neutron-rich isotopes via photofission of actinide targets. We present simulations with the Geant4 toolkit of the photofission process for the design and optimization of the expected performance parameters of the Cryogenic Stopping Cell (CSC). The CSC will be used to extract the photofission fragments into the secondary beam of about 10{sup 6} ions/s. We propose an experimental program to study refractory neutron-rich isotopes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nuclear structure studies in the seaborgium region at SHIP

New decay data for the isotopes {sup 259}Sg and {sup 255}Rf were obtained at the velocity filter SHIP using an α-decay spectroscopy measurement. Both isotopes were produced and studied via a one neutron evaporation channel in the compound fusion reaction {sup 54}Cr+{sup 208}Pb. New isomeric states were observed and the single-particle level systematics for isotones with 151 and 153 neutrons were extended. A change of the ground-state configuration for the heaviest N = 151 isotones was observed. Detailed Monte-Carlo simulation for the α decay of {sup 259}Sg applying the GEANT4 toolkit was performed and compared with experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The AMoRE: Search for neutrinoless double beta decay of {sup 100}Mo

The AMoRE (Advanced Mo-based Rare process Experiment) collaboration is using calcium molybdate ({sup dep48}Ca {sup 100}MoO{sub 4}) crystals enriched in {sup 100}Mo and depleted in {sup 48}Ca to search for neutrinoless double-beta decay (DBD) of {sup 100}Mo using at the underground laboratory in Korea. Metallic magnetic calorimeters operating a milliKelvin temperatures are used as temperature sensors to measure heat and light signals from the crystals. The simultaneous and fast detection capabilities for both phonons and photons, and their excellent energy resolution provide powerful methods for identifying DBD signals and rejecting background events, which are mainly due to random coincidences between two uncorrelated two-neutrino-double-beta decays of {sup 100}Mo. The AMoRE-Pilot experiment that is currently underway uses a 1.5 kg, five-element array of {sup dep48}Ca {sup 100}MoO{sub 4} crystals. The ultimate goal is a ∼200 kg array of crystals and a half-life sensitivity of order 10{sup 26} years, which will access the inverted hierarchy region for effective Majorana neutrino masses, i.e., 0.02 to 0.05 eV. In this talk, we present recent progress on the development of low-background calcium molybdate detectors and results from room- and milli-Kelvin temperatures. Sensitivities based on GEANT4 simulations that incorporate measured background are reported.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopic properties and radiation damage investigation of a diamond based Schottky diode for ion-beam therapy microdosimetry

In this work, a detailed analysis of the properties of a novel microdosimeter based on a synthetic single crystal diamond is reported. Focused ion microbeams were used to investigate the device spectropscopic properties as well as the induced radiation damage effects. A diamond based Schottky diode was fabricated by chemical vapor deposition with a very thin detecting region, about 400 nm thick (approximately 1.4 μm water equivalent thickness), corresponding to the typical size in microdosimetric measurements. A 200 × 200 μm{sup 2} square metallic contact was patterned on the diamond surface by standard photolithography to define the sensitive area. Experimental measurements were carried out at the Ruder Boškovic′ Institute microbeam facility using 4 MeV carbon and 5 MeV silicon ions. Ion beam induced charge maps were employed to characterize the microdosimeter response in terms of its charge collection properties. A stable response with no evidence of polarization or memory effects was observed up to the maximum investigated ion beam flux of about 1.7 × 10{sup 9} ions·cm{sup −2}·s{sup −1}. A homogeneity of the response about 6% was found over the sensitive region with a well-defined confinement of the response within the active area. Tests of the radiation damage effect were performed by selectively irradiating small areas of the device with different ion fluences, up to about 10{sup 12} ions/cm{sup 2}. An exponential decrease of the charge collection efficiency was observed with a characteristic decay constant of about 4.8 MGy and 1 MGy for C and Si ions, respectively. The experimental data were analyzed by means of GEANT4 Monte Carlo simulations. A direct correlation between the diamond damaging effect and the Non Ionizing Energy Loss (NIEL) fraction was found. In particular, an exponential decay of the charge collection efficiency with an exponential decay as a function of NIEL is observed, with a characteristic constant of about 9.3 kGy-NIEL for both carbon and silicon ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of imaging plate detector sensitivity to 5-18 MeV electrons

Imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. We calibrated at the ELSA electron beam facility (CEA DIF) the five different available types of IPs (namely, MS-SR-TR-MP-ND) to electrons from 5 to 18 MeV. In the context of diagnostic development for the PETawatt Aquitaine Laser (PETAL), we investigated the use of stacks of IP in order to increase the detection efficiency and get detection response independent from the neighboring materials such as X-ray shielding and detector supports. We also measured fading functions in the time range from a few minutes up to a few days. Finally, our results are systematically compared to GEANT4 simulations in order to provide a complete study of the IP response to electrons over the energy range relevant for PETAL experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Telescope performance and image simulations of the balloon-borne coded-mask protoMIRAX experiment

In this work we present the results of imaging simulations performed with the help of the GEANT4 package for the protoMIRAX hard X-ray balloon experiment. The instrumental background was simulated taking into account the various radiation components and their angular dependence, as well as a detailed mass model of the experiment. We modelled the meridian transits of the Crab Nebula and the Galactic Centre (CG) region during balloon flights in Brazil (∼ −23° of latitude and an altitude of ∼40 km) and introduced the correspondent spectra as inputs to the imaging simulations. We present images of the Crab and of three sources in the GC: 1E 1740.7-2942, GRS 1758-258 and GX 1+4. The results show that the protoMIRAX experiment is capable of making spectral and timing observations of bright hard X-ray sources as well as important imaging demonstrations that will contribute to the design of the MIRAX satellite mission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗