Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GROUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Developing High-Energy Laser-Driven Bremsstrahlung Radiation Sources for Imaging and Analysis of Nuclear Waste Packages - 17300

Radiographic imaging of small scale simulated nuclear waste packages (a 28 mm uranium penny encapsulated in grout) was achieved using a single pulse exposure from an x-ray source driven by a high-power laser. The high-energy laser pulse was generated at the Vulcan laser facility, which focused the photon burst onto a tantalum target foil in order to produce a bright burst of highly penetrating x-rays (with energy >500 keV) from a source size less than 0.5 mm. The sample was imaged using BAS-TR and BAS-SR image plates alongside a Thallium doped Caesium Iodide scintillator-based detector coupled to CCD chips for rapid image acquisition. The penny was resolved to sub-mm accuracy over a 30 cm{sup 2} scan area from a single shot. In addition, on a parallel beamline, neutron generation (of 10{sup 7}-10{sup 9} neutrons per steradian per pulse) was achieved, thereby demonstrating the potential application for criticality testing of waste packages. The principle concern regarding intermediate level waste (ILW) containers is the internal volumetric expansion due to the formation of corrosion products. Therefore, simulated waste samples with hydride corrosion have been formed and characterised in order to emulate this phenomenon. In addition, samples containing controlled isotopic ratios have been formed. This next generation of simulated waste samples have been produced in preparation for a second phase of analysis at the Vulcan laser facility to quantify the identification ability of radiographic imaging and characterisation accuracy of neutronics measurements. This feasibility study successfully demonstrated non-destructive radiography of encapsulated, high density, nuclear material and this paper details the next phase of technological development. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remediation of 130 mSv/hr. Soil Contamination Under a Hot Cell - 17301

Department of Energy (DOE) contractor CH2M HILL Plateau Remediation Company (CH2M) is currently engineering a system to safely remove and dispose of highly contaminated soil underneath Building 324 located adjacent to the Columbia River on the Hanford Site in Washington State. Cleaning up the waste site will allow for the eventual demolition of the building, which is a top priority for DOE and CH2M due to the proximity of the Columbia River and City of Richland. Building 324 at Hanford was originally constructed in 1966 and was operated for a number of years serving various missions. One of the missions involved development of treatment processes for liquid high activity waste. As of result of one particular mission, liquid high activity waste was spilled in one of the building's hot cells (known as 'B' Cell) and the liquid leaked from a breach in a sump and through construction joints in the hot cell floor and into the soil. Sampling efforts using borehole technology revealed significant under-building contamination with dose rates measuring has high as 130 mSv/hr (13,000 R/hr.). The Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) between the Washington State, Department of Ecology (Ecology), the U.S. Environmental Protection Agency and the DOE has established a 2021 milestone for demolition and removal of the Building 324. Before building demolition can be undertaken, the highly contaminated soil must be removed from beneath the hot cell while the hot cell structure remains in place to provide shielding and containment during the soil remediation. CH2M will fabricate and install remotely operated equipment that will remove debris and grout in the cell, the floor of the hot cell, and the contaminated soil beneath the hot cell and package that soil for disposal. To ensure that the structure remains intact and does not shift during soil removal, support for the building structure must also be constructed as a prerequisite for the planned work. CH2M will use a full-scale mock-up of the Building 324 B Cell and airlock area to assist in the testing of the remotely operated equipment and the training of the soil removal team in a contamination-free environment to ensure efficient and safe performance of the challenging work of the project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Achieving Leak Tightness in New Savannah River Site Saltstone Disposal Units - 17454

Saltstone Disposal Unit (SDU) 6 is a new disposal unit at the Department of Energy's Savannah River Site Saltstone Disposal Facility. The Saltstone Facility is part of the site's overarching waste management and disposal system. It receives the low-level waste stream and will immobilize in grout more than 90 percent of the liquid volume generated during treatment of the site's liquid high level waste. SDU-6 is the first in a series of large disposal units to be constructed on site. Its internal diameter and height are 114 m (375 ft) and 13.1 m (43 ft), respectively. It uses a cylindrical wire-wrapped concrete water tank design (AWWA D110, Type I), and at 121 ML (32 Mgal), it is one of the largest structures of its kind in the country. Because of its size, SDU-6's base slab was placed in ten sections. Earlier placed sections restrained newer adjacent sections, resulting in shrinkage cracking. Visible cracks were repaired with epoxy. However, the SDU basemat leaked at less than an estimated 4 L/min rate during its first full-height hydrostatic test (2015). The project baseline was to install a coating system to chemically protect the concrete from the high-pH, high-sulfate Saltstone solutions. The coating was not installed during the first hydrostatic test, and subsequently, an adhered elastomeric liner system was chosen to provide higher assurance of bridging floor cracks and preventing leakage. A robust process was used to select and install a liner that will not only provide chemical protection but also achieve leak tightness, which was successfully demonstrated in a second hydrostatic test late in 2016. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste Form Development for Solidification of Liquid Secondary Wastes to Support Hanford Direct Feed Low Activity Waste Vitrification - 17484

The US Department of Energy/Office of River Protection DOE/ORP has funded a program led by Washington River Protection Solutions (WRPS) to develop and test cementitious waste forms for immobilization of liquid secondary waste (LSW) at the Hanford site in Southeastern Washington State. The LSW comprises a concentrated brine from processing liquid effluents at Hanford's Effluent Treatment Facility. The liquid effluents include condensates from the 242-A tank waste evaporator and future offgas condensates from the Low Activity Waste (LAW) Vitrification Facility. To facilitate waste form formulation development and testing, WRPS developed LSW simulants and engaged subject matter experts at the Savannah River National Laboratory (SRNL) and Pacific Northwest National Laboratory (PNNL). This paper describes results of recent work done to develop and test a grout formulation tailored to address the elevated sulfate levels in Hanford LSW. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modular Caustic-Side Solvent Extraction Unit (MCU) Improved Solvent Quality and Processing Results - 17496

The Modular Caustic-Side Solvent Extraction (CSSX) Unit (MCU) is a process for Cs-137 removal from legacy nuclear waste. MCU began hot operations in 2008 with an initial planned operating life of three years and a design life of five years. After eight years of operation, MCU has processed more than 23.8 million liters (6.3 million gallons) of waste. The MCU process uses a solvent developed by Oak Ridge National Laboratory (ORNL) to extract the fission product Cs-137 from liquid salt waste, or salt solution (SS), stored in the Tank Farms at Savannah River Site (SRS) after the material has been treated through the Actinide Removal Process (ARP). Batches of SS are prepared and first fed to the ARP, where it is treated to become clarified SS (CSS), then fed to MCU. Once the Cs-137 has been extracted by the solvent, the CSS becomes decontaminated SS (DSS), which is ultimately processed into a cementitious grout at the Saltstone Production Facility (SPF) and subsequently disposed of at the Saltstone Disposal Facility (SDF). The Cs-137 is then stripped from the solvent into an aqueous strip effluent (SE) stream for incorporation into borosilicate glass at the Defense Waste Processing Facility (DWPF). The solvent used in the MCU process is made of four components: the extractant (extracts Cs-137 from CSS), the modifier (increases solubility of extractant and suppressor in the diluent), the suppressor (suppresses the effects of anions and improves stripping), and the diluent (controls density and viscosity). There have been two solvents utilized during the lifetime of MCU. The first solvent was developed by ORNL and was used to design the plant based on its cesium removal capability. Due to the extended life of MCU, in order to continue to minimize the curies disposed at SDF, a new solvent capable of removing more cesium from the CSS was developed by ORNL and implemented at MCU. The second MCU solvent, Next-Generation Solvent (NGS), uses the same modifier and diluent as the original solvent, but a different extractant and suppressor. Subsequent changes to the overall MCU flowsheet were made for the use of NGS. The success of cesium removal from the CSS is often presented as the cesium decontamination factor (DF) achieved for each batch processed. The DF is the ratio of the concentration of cesium in the CSS to the cesium concentration in the DSS. The BOBCalixC6 based solvent was capable of achieving DFs between 100 and 400 for each DSS batch. The NGS solvent is capable of achieving DFs greater than 40,000 for each DSS batch. The NGS blend solvent is currently meeting the goals of the pure NGS solvent. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deployment of large tank monosodium titanate strike to increase salt processing at the Savannah river site - 15115

The treatment of high level waste (HLW) salt solutions using the Actinide Removal Process (ARP) and Modular Caustic Side Solvent Extraction Unit (MCU) began at Savannah River Site (SRS) in 2008. Since that time, over 6 million gallons of liquid HLW have been treated and the resulting low level waste (LLW) effluent immobilized in cementitious grout at salt-stone. In addition to the continued stabilization of liquid HLW, operating experience from the ARP/MCU facilities has also been valuable in considering the design and construction of the Salt Waste Processing Facility (SWPF) which will utilize similar unit operations on a much larger scale. ARP removes actinides by contacting waste with monosodium titanate (MST) which is a solid adsorbent for soluble strontium and actinides. Once the sorption reaction is complete, the MST solids are separated from salt solution via ultrafiltration through a crossflow filter. The throughput of initial operations of ARP/MCU was limited by the flowrate through the extraction process. However, after the implementation of a new solvent flowsheet, filtration of MST will be the rate limiting step in salt processing. For the entirety of ARP/MCU operation, Savannah River Remediation (SRR) has sought to improve process efficiency and performance through optimization and modification of the original facility design. These efforts have resulted in a best-single-year throughput of 4.9 million liters of decontaminated salt solution. In keeping with these practices, SRR recently initiated a project to improve filtration throughput by relocating the MST strike from small batches immediately upstream of the filtration unit to the underground waste tank used to batch and store salt solution feed for ARP/MCU. This process change will allow the bulk of MST solids to decant in the waste tank prior to filtration which should improve both the nominal operational filter flux as well as the achieved utility of filter operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Commercial submersible mixing pump for SRS tank waste removal - 15223

The Savannah River Site Tank Farms have 45 active underground waste tanks used to store and process nuclear waste materials. There are 4 different tank types, ranging in capacity from 2839 m{sup 3} to 4921m{sup 3} (750,000 to 1,300,000 gallons). Eighteen of the tanks are older style and do not meet all current federal standards for secondary containment. The older style tanks are the initial focus of waste removal efforts for tank closure and are referred to as closure tanks. Of the original 51 underground waste tanks, six of the original 24 older style tanks have completed waste removal and are filled with grout. The insoluble waste fraction that resides within most waste tanks at SRS requires vigorous agitation to suspend the solids within the waste liquid in order to transfer this material for eventual processing into glass filled canisters at the Defense Waste Processing Facility (DWPF). SRS suspends the solid waste by use of recirculating mixing pumps. Older style tanks generally have limited riser openings which will not support larger mixing pumps, since the riser access is typically 58.4 cm (23 inches) in diameter. Agitation for these tanks has been provided by four long shafted standard slurry pumps (SLP) powered by an above tank 112 kW (150 HP) electric motor. The pump shaft is lubricated and cooled in a pressurized water column that is sealed from the surrounding waste in the tank. Closure of four waste tanks has been accomplished utilizing long shafted pump technology combined with heel removal using multiple technologies. Newer style waste tanks at SRS have larger riser openings, allowing the processing of waste solids to be accomplished with four large diameter SLPs equipped with 224 kW (300 HP) motors. These tanks are used to process the waste from closure tanks for DWPF. In addition to the SLPs, a 224 kW (300 HP) submersible mixer pump (SMP) has also been developed and deployed within older style tanks. The SMPs are product cooled and product lubricated canned motor pumps designed to fit within available risers and have significant agitation capabilities to suspend waste solids. Waste removal and closure of two tanks has been accomplished with agitation provided by 3 SMPs installed within the tanks. In 2012, a team was assembled to investigate alternative solids removal technologies to support waste removal for closing tanks. The goal of the team was to find a more cost effective approach that could be used to replace the current mixing pump technology. This team was unable to identify an alternative technology outside of mixing pumps to support waste agitation and removal from SRS waste tanks. However, the team did identify a potentially lower cost mixing pump compared to the baseline SLPs and SMPs. Rather than using the traditional procurement using an engineering specification, the team proposed to seek commercially available submersible mixer pumps (CSMP) as alternatives to SLPs and SMPs. SLPs and SMPs have a high procurement cost and the actual cost of moving pumps between tanks has shown to be significantly higher than the original estimates that justified the reuse of SMPs and SLPs. The team recommended procurement of 'off-the-shelf' industry pumps which may be available for significant savings, but at an increased risk of failure and reduced operating life in the waste tank. The goal of the CSMP program is to obtain mixing pumps that could mix from bulk waste removal through tank closure and then be abandoned in place as part of tank closure. This paper will present the development, progress and relative advantages of the CSMP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of SuperLig{sup R} 605 and SuperLig{sup R} 644 in a Regeneration Flow Sheet to Remove Radioactive Strontium and Cesium from Seawater - 16236

Remediation techniques are needed for efficient removal of radioactive strontium and cesium from seawater. Molecular Recognition Technology, using selective SuperLig{sup R} resins, demonstrates a clean chemistry approach to solving this problem. Molecular Recognition Technology offers high levels of separation of chemically pure metal contaminants, whose subsequent disposal is compatible with simple waste forms (grout and glass). SuperLig{sup R} resins can be regenerated with common reagents and used many times, limited by a dose of 1 E+9 Rad, which assures low volumes of secondary solid waste. The metal selectivity of the SuperLig{sup R} resin ensures that the solid waste is of low residual activity. These properties of sustainability are illustrated in a project that demonstrated the ability of two SuperLig{sup R} resins to selectively remove Cs and Sr from a seawater mimic representative of the contaminated seawater in Fukushima, Dai'ichi, Japan harbor. Removal of radioactive Sr-90 and Cs-134/Cs-137 from seawater using conventional ion exchange or a complexing agent is complicated by the presence of large excesses of competing ions such as Na, K, Ca, and Mg, which can be co-extracted. These competing ions, if co-extracted, reduce the capacity of a single pass resin with the consequent increase in volume of spent resin or decrease in capacity of a regenerable resin. The successful demonstration reported in this study has shown the ability of two proprietary resins, SuperLig{sup R} 605 and SuperLig{sup R} 644, to remove Sr and Cs, respectively, with high selectivity from simulated solutions containing these metal ions together with major constituents of seawater at their normal concentrations. This effort was part of a demonstration project to investigate methods for removal of Sr-90 and Cs-134/Cs-137 from 160,000 cubic meters of seawater impounded at Fukushima, Dai'ichi, Japan harbor. SuperLig{sup R} resins can be regenerated by elution with small volumes of simple acid solutions. SuperLig{sup R} resins have a high tolerance to radiation, with their performance not being degraded by doses of 1.0 E+9 Rad. Estimates, based on the results obtained, are that Cs and Sr levels in the volume of seawater in the Fukushima, Dai'ichi, Japan harbor could be reduced to desired discharge limits in 200 days with some 30 cubic meters of the two SuperLig{sup R} resins and that decontamination factors of 10 or more could be achieved. Results of the demonstration, together with advantages of the Molecular Recognition Technology process over conventional procedures for these separations are presented and discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimising Blends of Blast Furnace Slag for the Immobilisation of Nuclear Waste - 16245

The legacy of nuclear waste at the Sellafield site in the UK is an ongoing issue, and the current preferred route for the disposal of low and intermediate level waste is encapsulation in a cementitious matrix, formulated by blending Portland cement with blast furnace slag (BFS). Due to demands and economic challenges faced by the cement and steel industries, the supply of BFS to the UK nuclear industry has been inconsistent. These changes have caused the industry to move from a unique BFS powder supply with a certain specification to a combination of standard commercially available cementitious powders. The material currently used at the Sellafield site is a blend of ground granulated blast furnace slag (GGBS) and a coarser fraction of the same composition called Calumite, combined with Portland cement. This work involves future-proofing the supply of BFS for the UK nuclear industry by optimising the blend of the two fractions of BFS in order to replicate the unique specification required by Sellafield Ltd. The main emphasis is on the particle size distribution (PSD) and how this impacts the properties of the final wasteform. The study investigates the performance properties of the blended grouts such as workability, particle packing and heat evolution. Results show that the PSD of the cement powders affect both the physical and chemical properties of the cementitious matrix produced. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detection and Mitigation of Hanford Site Radioactive Waste Tank Surface Water Intrusion - 16396

The last single-shell underground radioactive waste storage tanks at the U.S. Department of Energy's Hanford Site, near Richland, WA, were removed from service in November, 1980. At that time the single-shell tanks contained 153,300 m{sup 3} (40.5 million gallons) of waste, including 34,400 m{sup 3} (9.1 million gallons) of liquids. Subsequently the Interim Stabilization Program and Waste Retrieval/Closure Project have removed 24,600 m{sup 3} (6.5 million gallons) of liquid from the tanks to reduce the potential for leakage to the environment. After interim stabilization, each tank was isolated by cutting and capping waste transfer lines, filling drains with grout, and covering likely surface water entry points. The minimum expected lifetime for the isolation features was 20 years, consistent with planned retrieval of all single-shell tank wastes by 2018. Since then the retrieval completion date has been extended. In 2011 the Tank Operating Contractor began a systematic review of the aging isolation barriers to determine if surface water was entering the single-shell tanks. This paper summarizes the results of the 2011 - 2015 activities including single-shell tank inspection results, methodologies used to identify intrusions and waste leaks masked by intrusion, and eventual deployment of a prototype forced ventilation exhauster in 2015 to evaporate water intrusion pools on the waste surface. Further efforts to limit water intrusion, including deployment of surface barriers, are discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integration of National Laboratory and Low-Activity Waste Pretreatment System Technology Service Providers - 16435

The National Laboratories are a critical partner and provide expertise in numerous aspects of the successful execution of the Direct-Feed Low Activity Waste Program. The National Laboratories are maturing the technologies of the Low-Activity Waste Pretreatment System consistent with DOE Order 413.3B, 'Program and Project Management for the Acquisition of Capital Assets', expectations. The National Laboratories continue to mature waste forms, i.e., glass and secondary waste grout, for formulations and predictions of long-term performance as inputs to performance assessments. The working processes with the National Laboratories have been developed in procurements, communications, and reporting to support the necessary delivery-based technology support. The relationship continues to evolve from planning and technology development to support of ongoing operations and integration of multiple highly coordinated facilities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste Management Processing Projects in the PRC - 16551

EnergySolutions continues to provide waste treatment solutions in the Peoples Republic of China (PRC). In 2015 ES had completed installation of systems at two different Nuclear power sites (Haiyang, an AP-1000{sup TM} site and Yangjiang, a CPR1000 site). This paper discusses progress on these two projects, and provides new information regarding the operation of the systems. The Yangjiang project became operational in the fall of 2015 while the Haiyang project will be done is nearly done with commissioning and is waiting for reactor operations. Haiyang Project: In the Shandong Province on China's northeast coast, EnergySolutions, as part of a consortium with China Power Investment (CPI) and Yuanda Environmental Protection Engineering Company (a PRC state-owned company), has designed and constructed the site's Site Rad Waste Treatment Facility (SRTF). The SRTF provides solid waste processing services for up to 8 AP-1000s{sup TM}. The SRTF performs the following functions: 1. Five year storage for HICs containing spent resin and filters from the nuclear power plants' waste liquid systems (WLS); 2. Sorting and Compaction System for solid waste generated from Nuclear Power Plant (NPP) operations. This system implements: a) Real time radiography to screen 200 liter waste drums for prohibited items, b) Pre-compaction, c) High Resolution Gamma Spectrophotometry (HRGS) for waste characterization, d) Supercompaction, e) Solidification of compacted drums inside overpack drums which are filled with 60 MPa compressive strength grout, and f) Automatic drum lidding which crimps the drum lid to the drum body. 3. Laundry services for NPP anti-contamination clothing. 4. At the nuclear islands, EnergySolutions is providing mobile liquid waste processing systems that utilize EnergySolutions Advanced Liquid Processing System ALPS{sup TM}/Advanced Injection Method System AIM{sup TM} processing systems to supplement the NPP's WLS system when radionuclide concentrations exceed release criteria. The spent resins and filters from the nuclear power plants are placed in EnergySolutions supplied HICs, dewatered using EnergySolutions Self Engaging Dewatering System (SEDS{sup TM}), and then placed in EnergySolutions 8-120B Type B cask for the transport of the HIC between the NPP and the SRTF and, ultimately, to a disposal site once it is ready for operations Yangjiang Project: EnergySolutions is providing liquid waste treatment system (TEU) and solid waste treatment system (TES) for Yangjiang units 3 and 4 for the China Nuclear Power Engineering Company (CNPEC). The Yangjiang site is located approximately 300 kilometers west of Hong Kong. The TEU system processes floor drain, chemical drain, and process drain tanks liquids to achieve a release concentration less than 37 Bq/l. The TES system receives spent resin and filters into HIC containers which are dewatered and subsequently transported to the Yangjiang sites QT building where they are stored for a period of up to 5 years or until a disposal site are available. TEU (Liquid waste treatment) consists of the following unit operations: - ALPS{sup TM}/AIM{sup TM} system, which includes two separate 8 vessel water treatment systems that consist of granular activated carbon (GAC), cation, anion ion and mixed bed media ion exchange (IX) columns; and: - A reverse osmosis system for final polishing, - TES (solid waste system), - SEDS (Self Engaging Dewatering System), - Shielding for the loading and storage of HICs, - Shielded transport container for the transfer of HIC to the QT building for storage, - Shielded transfer bell for the transport of spent filters from the NPP operating area to HIC. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Innovative Waste Packaging and Associated Venting/Hydrogen Management - 16594

The original strategy for managing intermediate level waste (ILW) was developed in the 1980s by the UK Nuclear Industry Radioactive Waste Executive (NIREX), which is now the Radioactive Waste Management Limited (RWM), a wholly owned subsidiary of the Nuclear Decommissioning Authority (NDA). The strategy involved retrieving ILW, sorting and encapsulating it in cement based grout within thin walled stainless steel containers. The containers would then be transferred to a large purpose-built shielded ILW store on site, where they would be stored until the planned final deep geological disposal facility becomes available. In recognition of the high up-front costs of such a strategy, which requires remote facilities for the encapsulation and storage, and coupled with the long programme duration for the design, construction and commissioning of these facilities, waste management organisations responsible for managing the clean-up of legacy facilities within the UK have, in recent years, sought innovative solutions which could potentially both accelerate clean-up and hazard reduction on sites, and with a lower overall programme lifecycle cost. Many of the recent innovative solutions are focused around a new family of packaging designs known as robust shielded containers (RSCs). These are self-shielded containers manufactured from materials such as ductile cast iron or fabricated steel. These containers offer the potential to package wastes for disposal without encapsulation and avoid the need for a highly engineered remote handled shielded store for interim storage. The paper provides a high level overview of the generic concepts of RSCs developed by Croft and focuses on the specific challenges of wasteform evolution on waste package integrity and performance. In particular, the integrity and performance of the filtered vent system required to manage internal pressurisation and to ensure sufficient venting capacity of hydrogen and other evolved gases. The paper summarises the analysis by ARUP undertaken to substantiate the RSC integrity under detonation/deflagration explosion loadings arising from hydrogen accumulation. Analyses of the structural response of the filter assembly were undertaken for both detonation and deflagration explosion scenarios, with the loadings applied to the filter housing rim and to the filter vent cover. The paper also presents evidence of the mechanical performance of the filter medium in terms of pressure transients during deflagration events and the degree to which filtration efficiency is maintained. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste - 16648

Measures required to assure long term safe storage of Low-level and intermediate-level short-lived (LIL/SL) waste generated by the nuclear-power industry in France include the characterization of the waste and identification of materials within the waste. Digital Radiography (DR) techniques using x-ray at energies in the 6 MeV range have been shown to be effective for validation of the integrity of the concrete containers, and it was considered that the use of this technique together with the addition of Computed Tomography (CT) techniques could effectively identify materials within the waste. This paper describes the initial evaluation of two DR imaging techniques and two CT techniques using x-ray energy spectra up to 9 MeV to inspect a surrogate waste package, which comprised an outer concrete cylindrical container of 1400 mm diameter with 148 mm wall thickness, and an overall volume of 2 meters cubed, within which a 200 liter drum containing representative heterogeneous inactive waste, was placed in the center and the annulus between the 200 liter drum and the outer cylindrical package was filled with cement grout. The surrogate waste within the 200 liter drum comprised three separate layers of high density, medium density and low density mixed materials. The equipment used was a linear accelerator producing high energy spectra at either 6 MeV or 9 MeV and a high-precision CT manipulator with X, Y, Z and rotation motions, which were common to all techniques investigated. Two different digital detectors were used in the DR and CT performance evaluations, a Digital Detector Array (DDA) comprising a columnar Thallium-doped Cesium-Iodide scintillator screen in intimate contact with a 2 k by 2 k array of amorphous silicon detectors, 200 μm x 200 μm in area, and a Linear Diode Array (LDA) comprising a line of Cadmium-Tungstate columns, 1 cm thick and 400 μm x 400 μm in area. The work comprised evaluations of linear accelerator spectra and the attenuation effects of the waste container and contents, image acquisition performance of each detector, and CT techniques using area detector and linear detector. The results presented in this paper include mathematical evaluation of the two CT techniques, and analysis of measurement data, digital images, CT reconstruction images, and estimated material densities. The data was compared with recorded details and photographs of the actual configuration of materials within the surrogate waste. The Digital Detector Array can generate CT inspection volumes with considerable resolution and detail for the low-density and medium-density sections of the surrogate waste, however, the high-density sections were not imaged with sufficient detail and the images contained a large number of artifacts mainly due to the detectors lack of high energy photon stopping power. Materials identification with the Digital Detector Array, while possible for certain materials, for materials in the steel to plastic density range the attenuation values of the voxels in the reconstruction are too similar and difficult to resolve from the artifacts present. The Linear Diode Array can generate CT inspection volumes of regions of interest of the low-density and medium-density sections with considerable resolution and contrast, and potentially acceptable levels of resolution and contrast of the high-density section of the waste. While a few artifacts were present in the reconstructions, the majority are not due to the fundamental properties of the detector and are considered to be correctable. Materials identification with the LDA inspection data appear to be viable, with steel, copper, and higher-density metals being readily be distinguished from other materials on the basis of voxel value. Future work is needed to obtain a better definition of optimum spatial resolution and inspection speed, and to develop a system of 'calibration rods' which would consist of a series of 50 mm diameter cylinders of 7 materials; Plastic, Teflon, Concrete, Aluminum, Copper, Tungsten and Lead. The cylinders will be distributed at a certain radius in the surrogate waste and will be used as reference points in the evaluation and demonstration of the contrastive performance for the low, medium and high-density cases. The ability to identify the materials within a sealed waste container, by nondestructive examination, enables the verification of waste acceptance criteria without the need to open the waste containers. This eliminates the need for complex and expensive equipment to open and remotely handle the intermediate level waste, avoids potential hazards and risk of personnel dose uptake, and does not increase the volume of waste caused by repackaging of materials after examination and the decontamination or disposal of equipment used.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cementation of Nuclear Wastes: From Past to Future in a Sustainable Approach - 18266

Cementation of nuclear wastes is a widespread technology due to several factors such as excellent feedback from past experience, simplicity of implementation and versatility. Indeed, as nuclear wastes come in many physical states (bulk wastes, powders, sludges), cementation is the immobilisation process that can easily accommodate this large range of wastes provided the appropriate mixing technology is used: heterogenous cementation (grouting of bulky wastes) or homogenous cementation (intermixing process between the powder or the sludge and the cementitious material). However, nuclear wastes equally present an important chemical variability. This is especially true as New Areva's range of nuclear activities covers the entire fuel cycle: mining, conversion, enrichment and recycling and dismantling and decommissioning. The chemical interactions between the waste and the cement matrix are carefully studied by New Areva's R and D teams in order to provide comprehensive solutions by developing cement formulations which are adapted to wastes characteristics. The aim of the studies is to obtain cement waste-forms that meet the waste acceptance criteria, the final product being thus in perfect adequacy with the disposal requirements. For over 30 years New Areva has been developing cement formulations adapted to the physical and chemical specificities of the wastes accounting for constrains imposed by waste characteristics. The overall approach includes the definition of the appropriate cement composition at laboratory scale, engineering design, equipment manufacturing, testing and commissioning of the cementation facilities. With this strong technical background, a specific methodology has been developed by New Areva teams in order to allow a rapid screening of possible solutions for a given waste (in terms of cement chemistry adapted to the waste) in a learn-fast approach that is based on theoretical analysis and small-scale tests. The methodology was applied for wastes presenting a complex nature (such as reactive metals, ion exchange resins, oils and solvents, mercury, etc), known to interact with Portland cement from a chemical point of view and leading to durability issues of the wasteform (swelling, strength reduction, leaching) and thus reducing the final waste loading. Once the screening process is over, the main drivers for choosing the most appropriate solution to be further developed at pilot scale are: reducing the overall volume and the impact of the final waste package, ensure the waste package performance as defined by the disposal requirements and control the long-term behaviour in final disposal. Moreover, a modelling approach is addressed, aiming to develop a thermo-chemo-mechanical (THM) concrete models that are able to predict the behaviour of the structure (waste form) in time. The aim of the present paper is to describe the main principles within the developed methodology and illustrate it by using a few specific examples. Several distinct cement formulations are developed for complex wastes, limiting the chemical interaction between the cement matrix and the given wastes, obtaining better waste loadings and better overall durability behaviour which facilitates long term behaviour demonstration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of Robotics in Liquid Waste System - {sup 3}H Evaporator, Tank Closure and Defense Waste Processing Facility - 18525

The Savannah River Site (SRS) Liquid Waste System (LWS) safely stores and treats high-level radioactive waste. The LWS consists of 51 waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities such as the Defense Waste Processing Facility (DWPF) and Salt-stone Production Facility (SPF). At Savannah River Remediation (SRR), the liquid waste contractor, robotic technologies are needed to enter areas and spaces that are otherwise inaccessible or prohibit direct access by workers due to unsafe, unstable, or unknown physical or structural conditions; or configurations that are hard to reach or beyond reach without taking extraordinary mechanical measures. As discussed below, SRR uses robotic technologies at various LWS facilities to reduce dose to the workers as well as provide access to unreachable locations due to the presence of radiological or chemical hazards. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Special Analyses for the Hanford Integrated Disposal Facility Performance Assessment - 20102

In 2014, the Department of Energy (DOE) Office of River Protection and its contractors began to develop a performance assessment for the near-surface disposal of low-level and mixed low-level waste at the Hanford Site's Integrated Disposal Facility (IDF). The IDF is a doubly-lined landfill that was constructed between 2004 and 2006 to be the disposal facility for the vitrified low-activity waste that will be produced at the Waste Treatment and Immobilization Plant (WTP). IDF is also expected to receive solid secondary waste produced at the WTP and other solid wastes from site activities. The IDF has been in a preoperational state awaiting authorization from DOE and a RCRA permit modification from the State of Washington Department of Ecology to receive waste. Both the Disposal Authorization Statement and permit modification require a performance assessment demonstrating that the system of engineered and natural features will limit releases of radionuclides and hazardous chemicals from the IDF and be protective of human health and the environment. The simulated duration is 10,000 years. Based on the analyses presented in the 2017 Integrated Disposal Facility Performance Assessment, DOE issued a conditional Operating Disposal Authorization Statement for the IDF in June 2018. The long-term performance of the IDF to be protective of human health and the environment was evaluated under the requirements of DOE Order 435.1, Radioactive Waste Management. Computer simulations were performed to evaluate whether or not the IDF would comply with DOE requirements. In the time that has passed since the performance assessment was approved by DOE, new information has been discovered that had not been considered in the performance assessment. Since this new information has not been evaluated, the potential impact of the changes have not been taken into consideration in DoE's disposal authorization. DOE and its contractors follow a change control process to screen and, when necessary, evaluate new information that could potentially impact the conclusions of the completed performance assessment. This paper will describe the change control process and provide two examples of evaluations performed following the change control process. The first example evaluates a new waste form for liquid secondary waste that was not evaluated in the performance assessment. In the performance assessment, liquid secondary waste was assumed to be solidified with grout. A new recommendation to dispose of the liquid secondary waste after drying it to a powder was evaluated. The second example evaluates inventory implications from changes to the flow sheet that estimates the feed composition to the low-activity waste vitrification facility. The changes result in higher strontium concentrations in the vitrified waste stream. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utilizing Commercial Submersible Mixer Pumps for Sludge Removal in Savannah River Site's Tank 26 - 20289

The Savannah River Site (SRS) Liquid Waste System (LWS) safely manages, stores, treats, and dispositions liquid radioactive waste. The LWS consists of 51 underground waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities, known as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). One of the waste storage tanks, Tank 26, was placed into service in 1980 as an F Tank Farm (FTF) Evaporator Feed Tank. From 1980 to 2013, Tank 26 received F Canyon receipts and dilute supernate that was then transferred to the 242-16F FTF Evaporator for volume reduction. In 2013, the steam tube bundle failed in the FTF Evaporator, and the decision was made not to repair/resume evaporator operation. During operation of Tank 26, solids built up to a level of 2.03 m in the tank with a volume of 1062.9 kL. Due to the evaporator failure and subsequent shutdown, the solids in Tank 26 were selected to feed Sludge Batch 10, which is collected and prepped prior to being sent to DWPF for final disposition. To accomplish solids removal, Commercial Submersible Mixer Pumps (CSMPs) were selected to slurry the solids in preparation to be sent to Tank 51. Four CSMPs were installed in Tank 26 with each one installed in a separate quadrant of Tank 26. This work would mark the first deployment of CSMPs in an SRS waste tank. The CSMPs were developed in response to operational issues from previous mixing pumps and budgetary constraints. The CSMPs use the concept of modifying commercially available equipment for nuclear waste applications. The CSMPs consist of a 230-horsepower submersible mixing pump (manufactured by GPM, Inc.) joined to a mast fabricated at SRS. For this application, Savannah River Remediation (SRR) design services was challenged to provide a mast design that required no steel superstructure support system on top of Tank 26. Also, SRR design services provided a simplified Tank 26 riser interface that did not require extensive machine parts to adjust height of the suction screen of the CSMP within the tank. Other design improvements include no requirements for tank top radiation monitors and no requirements for flushing of the CSMPs during startup/shutdown operations. The CSMPs were operated at an initial height of 2.29 m above the Tank 26 bottom for 10 days. After sludge sounding, the CSMPs were lowered to a height of 1.52 m with no issues due to proper work planning and the simplified riser interface. With the CSMPs lowered to a level of 1.52 meters above the tank bottom, the CSMPs were operated for 12 days and another sounding was performed. The sounding level came back matching the disturbance depth results of the first pump run. Chemistry samples were analyzed while the tank was left to settle. The analysis revealed enough weight percent solids to provide good feed to Sludge Batch 10. Also, the results revealed the supernate within the mixture would provide good salt solution feed to Salt Waste Processing Facility (SWPF) Salt Batch 3. So, the plan was modified to let the disturbed solids settle and decant the salt solution for addition to SWPF Salt Batch 3. Then water will be added back to Tank 26, and the CSMPs run in order to wash the solids to decrease settling time prior to being sent to Tank 51 for Sludge Batch 10. Utilizing CSMPs for waste removal in an SRS Tank has provided a cost-effective means for further waste removal efforts. In addition, the CSMPs are easier to operate by utilizing a robust and simplified design. The CSMPs performed quite well with no process shutdown or delays during operation. As a result, CSMPs are integral to the future of removing radioactive waste from storage tanks at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗