Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAUSS FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Therapeutic analysis of high-dose-rate {sup 192}Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions

Purpose: To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. Methods: A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model was used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gy × 4 fractions) or at the vaginal mucosal surface (8.8 Gy × 4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. Results: EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gy × 4 and 7.8 Gy × 4, the TRs were in the range from (5.0){sup 4} to (13.4){sup 4} for the radiosensitive normal tissue depending on the cylinder size, treatment lengths, prescription depth, and dose as well. However, for a uniform cancer cell distribution, the EUDs were between 6.3 Gy × 4 and 7.1 Gy × 4, and the TRs were found to be between (1.4){sup 4} and (1.7){sup 4}. For the uniformly interspersed cancer and radio-resistant normal cells, the TRs were less than 1. The two VCBT prescription regimens were found to be equivalent in terms of EUDs and TRs. Conclusions: HDR VCBT strongly favors cylindrical target volume with the cancer cell distribution following its dosimetric trend. Assuming a half-Gaussian distribution of cancer cells, the HDR VCBT provides a considerable radiobiological advantage over the external beam radiotherapy (EBRT) in terms of sparing more normal tissues while maintaining the same level of cancer cell killing. But for the uniform cancer cell distribution and radio-resistant normal tissue, the radiobiology outcome of the HDR VCBT does not show an advantage over the EBRT. This study strongly suggests that radiation therapy design should consider the cancer cell distribution inside the target volume in addition to the shape of target.

61 RADIATION PROTECTION AND DOSIMETRY↗

A robust real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system

Purpose: To develop a robust and real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system. Methods: The authors have developed a robust and fast surface reconstruction method on point clouds acquired by the photogrammetry system, without explicitly solving the partial differential equation required by a typical variational approach. Taking advantage of the overcomplete nature of the acquired point clouds, their method solves and propagates a sparse linear relationship from the point cloud manifold to the surface manifold, assuming both manifolds share similar local geometry. With relatively consistent point cloud acquisitions, the authors propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, assuming that the point correspondences built by the iterative closest point (ICP) is reasonably accurate and have residual errors following a Gaussian distribution. To accommodate changing noise levels and/or presence of inconsistent occlusions during the acquisition, the authors further propose a modified sparse regression (MSR) model to model the potentially large and sparse error built by ICP with a Laplacian prior. The authors evaluated the proposed method on both clinical point clouds acquired under consistent acquisition conditions and on point clouds with inconsistent occlusions. The authors quantitatively evaluated the reconstruction performance with respect to root-mean-squared-error, by comparing its reconstruction results against that from the variational method. Results: On clinical point clouds, both the SR and MSR models have achieved sub-millimeter reconstruction accuracy and reduced the reconstruction time by two orders of magnitude to a subsecond reconstruction time. On point clouds with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent and robust performance despite the introduced occlusions. Conclusions: The authors have developed a fast and robust surface reconstruction method on point clouds captured from a 3D surface photogrammetry system, with demonstrated sub-millimeter reconstruction accuracy and subsecond reconstruction time. It is suitable for real-time motion tracking in radiotherapy, with clear surface structures for better quantifications.

60 APPLIED LIFE SCIENCES↗

SU-F-I-45: An Automated Technique to Measure Image Contrast in Clinical CT Images

Purpose: To develop and validate an automated technique for measuring image contrast in chest computed tomography (CT) exams. Methods: An automated computer algorithm was developed to measure the distribution of Hounsfield units (HUs) inside four major organs: the lungs, liver, aorta, and bones. These organs were first segmented or identified using computer vision and image processing techniques. Regions of interest (ROIs) were automatically placed inside the lungs, liver, and aorta and histograms of the HUs inside the ROIs were constructed. The mean and standard deviation of each histogram were computed for each CT dataset. Comparison of the mean and standard deviation of the HUs in the different organs provides different contrast values. The ROI for the bones is simply the segmentation mask of the bones. Since the histogram for bones does not follow a Gaussian distribution, the 25th and 75th percentile were computed instead of the mean. The sensitivity and accuracy of the algorithm was investigated by comparing the automated measurements with manual measurements. Fifteen contrast enhanced and fifteen non-contrast enhanced chest CT clinical datasets were examined in the validation procedure. Results: The algorithm successfully measured the histograms of the four organs in both contrast and non-contrast enhanced chest CT exams. The automated measurements were in agreement with manual measurements. The algorithm has sufficient sensitivity as indicated by the near unity slope of the automated versus manual measurement plots. Furthermore, the algorithm has sufficient accuracy as indicated by the high coefficient of determination, R2, values ranging from 0.879 to 0.998. Conclusion: Patient-specific image contrast can be measured from clinical datasets. The algorithm can be run on both contrast enhanced and non-enhanced clinical datasets. The method can be applied to automatically assess the contrast characteristics of clinical chest CT images and quantify dependencies that may not be captured in phantom data.

60 APPLIED LIFE SCIENCES↗

SU-F-T-142: An Analytical Model to Correct the Aperture Scattered Dose in Clinical Proton Beams

Purpose: Apertures or collimators are used to laterally shape proton beams in double scattering (DS) delivery and to sharpen the penumbra in pencil beam (PB) delivery. However, aperture-scattered dose is not included in the current dose calculations of treatment planning system (TPS). The purpose of this study is to provide a method to correct the aperture-scattered dose based on an analytical model. Methods: A DS beam with a non-divergent aperture was delivered using a single-room proton machine. Dose profiles were measured with an ion-chamber scanning in water and a 2-D ion chamber matrix with solid-water buildup at various depths. The measured doses were considered as the sum of the non-contaminated dose and the aperture-scattered dose. The non-contaminated dose was calculated by TPS and subtracted from the measured dose. Aperture scattered-dose was modeled as a 1D Gaussian distribution. For 2-D fields, to calculate the scatter-dose from all the edges of aperture, a sum of weighted distance was used in the model based on the distance from calculation point to aperture edge. The gamma index was calculated between the measured and calculated dose with and without scatter correction. Results: For a beam with range of 23 cm and aperture size of 20 cm, the contribution of the scatter horn was ∼8% of the total dose at 4 cm depth and diminished to 0 at 15 cm depth. The amplitude of scatter-dose decreased linearly with the depth increase. The 1D gamma index (2%/2 mm) between the calculated and measured profiles increased from 63% to 98% for 4 cm depth and from 83% to 98% at 13 cm depth. The 2D gamma index (2%/2 mm) at 4 cm depth has improved from 78% to 94%. Conclusion: Using the simple analytical method the discrepancy between the measured and calculated dose has significantly improved.

60 APPLIED LIFE SCIENCES↗

Disorder and pseudogap in strongly correlated systems: Phase diagram in the DMFT + {Sigma} approach

The influence of disorder and pseudogap fluctuations on the Mott insulator-metal transition in strongly correlated systems has been studied in the framework of the generalized dynamic mean field theory (DMFT + {Sigma} approach). Using the results of investigations of the density of states (DOS) and optical conductivity, a phase diagram (disorder-Hubbard interaction-temperature) is constructed for the paramagnetic Anderson-Hubbard model, which allows both the effects of strong electron correlations and the influence of strong disorder to be considered. Strong correlations are described using the DMFT, while a strong disorder is described using a generalized self-consistent theory of localization. The DOS and optical conductivity of the paramagnetic Hubbard model have been studied in a pseudogap state caused by antiferromagnetic spin (or charge) short-range order fluctuations with a finite correlation length, which have been modeled by a static Gaussian random field. The effect of a pseudogap on the Mott insulator-metal transition has been studied. It is established that, in both cases, the static Gaussian random field (related to the disorder or pseudogap fluctuations) leads to suppression of the Mott transition, broadening of the coexistence region of the insulator and metal phases, and an increase in the critical temperature at which the coexistence region disappears.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent X-ray radiation excited by a diverging relativistic electron beam in a single crystal

We develop a dynamic theory of coherent X-rays generated in a single-crystal wafer by a diverging relativistic electron beam. The dependence of the spectral-angular density of coherent X-ray radiation on the angle of divergence is analyzed for the case when the angular spread can be described by the 2D Gaussian distribution. The theory constructed here makes it possible to analyze coherent radiation for an arbitrary angular distribution of electrons in the beam as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recovery time in quantum dynamics of wave packets

A wave packet formed by a linear superposition of bound states with an arbitrary energy spectrum returns arbitrarily close to the initial state after a quite long time. A method in which quantum recovery times are calculated exactly is developed. In particular, an exact analytic expression is derived for the recovery time in the limiting case of a two-level system. In the general case, the reciprocal recovery time is proportional to the Gauss distribution that depends on two parameters (mean value and variance of the return probability). The dependence of the recovery time on the mean excitation level of the system is established. The recovery time is the longest for the maximal excitation level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theoretical Analysis of the EPR Spectrum Saturation Effect with Account for Spectral Diffusion in a System with a Gaussian Distribution of Spin Resonance Frequencies

We have analyzed the effect of saturation of the EPR spectrum for the model situation when a set of resonance frequencies of spin packets is described by a Gaussian distribution and spectral diffusion, which is a random process without correlation, exists. We have obtained the form of the spectrum for arbitrary values of magnetic–resonant parameters: relaxation times for the longitudinal and transverse components of the magnetization vector of the system, the spectral diffusion rate, the dispersion of the Gaussian distribution of resonance frequency, and the magnetic induction of the microwave field. We have derived an analytic expression for the saturation curve of the EPR spectrum. Detailed analysis of the dependence of the spectrum saturation curve on the spin system parameters is performed for the optimal case when the microwave field frequency coincides with the average frequency of the Gaussian distribution for resonance frequencies. The value of the microwave field induction at which the peak of the saturation curve is attained has been determined for arbitrary values of the paramagnetic relaxation time, spectral diffusion rate, and dispersion of the Gaussian spin frequency distribution. We have formulated the algorithm for determining the spin–lattice relaxation time using the experimentally determined microwave field induction for which the saturation curve passes through the peak. It should be noted that numerical calculations have been performed for parameters typical of EPR spectroscopy. The general analytic expression derived for the shape of the spectrum in the saturation conditions and qualitative conclusions concerning the effect of spectral diffusion on the saturation of stationary spectra obtained in this study can also be used in other fields of spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advection of a passive vector field by the Gaussian velocity field with finite correlations in time

Using the field theoretic renormalization group technique the model of a passive vector field advected by an incompressible turbulent flow is investigated up to the second order of the perturbation theory (two-loop approximation). The turbulent environment is given by statistical fluctuations of the velocity field that has a Gaussian distribution with zero mean and defined noise with finite correlations in time. Two-loop analysis of all possible scaling regimes in general d-dimensional space is done in the plane of exponents ɛ − η, where ɛ characterizes the energy spectrum of the velocity field in the inertial range E ∝ k{sup 1−2ε}, and η is related to the correlation time at the wave number k which is scaled as k{sup −2+η}. It is shown that the scaling regimes of the present model of vector advection have essentially different properties than the scaling regimes of the corresponding model of passively advected scalar quantity. The results demonstrate the fact that within the present model of passively advected vector field the internal tensor structure of the advected field can have nontrivial impact on the diffusion processes deep inside in the inertial interval of given turbulent flow.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studying the characteristics of scintillation counters in a beam of relativistic particles

In this work, the results of the measurements of characteristics of 40-cm and 2-m scintillation counters irradiated by a particle beam with a momentum of 7 GeV/c from the accelerator of the Institute for High Energy Physics are presented. The scintillators used in counters are BC-404 and BC-408 scintillators. The counters are viewed from both ends by R1828-01 photomultiplier tubes. The PMT signal spectra are well described by a convolution of the Landau and Gaussian distributions. Their width is determined mainly by fluctuations of ionization energy losses. The time distributions of the signals obey the Gaussian law. For the 40-cm counter, the time resolution is σ(T) = 88 ps; for the 2-m counter, it varies from 120–160 ps in its center to ~100 ps near the end.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the properties of the surface of gallium arsenide by scanning atomic force microscopy

Using the method of atomic force microscopy, complex studies of the profile, potential distribution {phi}(x,y), and distributions of the phase contrast of the surface of n-GaAs subjected to various types of chemical treatment are carried out. The distribution of the potential and phase contrast at a microlevel, in general, correlates with the profile character. The surface treated in the solution H{sub 2}SO{sub 4}: H{sub 2}O = 1: 10 is characterized by a high degree of nonuniformity with an average roughness of the main profile {delta}h{approx} 10 nm. A considerable part of the surface is covered by hills 20-60 nm in height and 100-500 nm in diameter forming a specific substructure, which correspond to potential jumps as large as 50-60 mV against a general background of 0.77-0.80 V. At a nanolevel, correlation between the profile and phase contrast is clearly pronounced, but no correlation is found between the profile and potential distribution. Treatment of the surface of n-GaAs in a concentrated aqueous NH{sub 4}OH solution leads to a decrease in the value of {phi}(x,y) by {approx}0.2 V, and in its roughness by more than an order of magnitude ({approx}0.75 nm). The distribution of the profile and phase contrast over the surface is close to the ideal Gaussian distribution for relatively small areas of the surface (200 x 200 nm{sup 2}). As the area increases, deviation from the Gaussian distribution becomes substantial because of smooth variation in the potential over the contact area. Conservation of the Gaussian character of the surface profile and a simultaneous rise in the average level of the roughness with an increase in the analyzed area indicates the fractal mechanism of formation of the surface profile.

36 MATERIALS SCIENCE↗

Electrical and optical properties of Mn-doped Hg{sub 3}In{sub 2}Te{sub 6} crystals

The effect of Mn impurities on the properties of Hg{sub 3}In{sub 2}Te{sub 6} crystals is studied by electrical and optical measurements. It is shown that, despite the high dopant concentration (1 Multiplication-Sign 10{sup 19} cm{sup -3}), the electron concentration remains the same as that in an undoped crystal ({approx}10{sup 13} cm{sup -3} at 300 K). At the same time, narrowing of the band gap from 0.74 to 0.7 eV is observed. From an analysis of the absorption spectra, it is found that the absorption edge is formed by optical transitions involving density-of-states (DoS) tails and that two acceptor- and donor-type impurity bands are formed in the band gap. The two bands are described by a Gaussian distribution of the DoS, with an energy gap between the peaks of E{sub 0} = E{sub d}{sup 0} - E{sub a}{sup 0} = 0.4 eV. The total donor and acceptor concentration N{sub d} + N{sub a} and the degree of compensation K = N{sub a}/N{sub d} {yields} 1 are determined. Such compensation is responsible for pinning of the Fermi level near the middle of the band gap and for quasi-intrinsic conductivity at temperatures T {>=} 300 K.

36 MATERIALS SCIENCE↗

Simulation of the ohmic loss in photovoltaic laser-power converters for wavelengths of 809 and 1064 nm

The method of mathematical simulation is used to examine the influence exerted by the characteristics of the epitaxial structure and contact grid of photovoltaic laser-power converters on their ohmic loss. The maximum attainable photoconverter efficiency at a Gaussian distribution of the laser-beam intensity on the surface of a photovoltaic converter and at dark-current densities of p–n junctions typical of structures grown by the metal-organic vapor-phase epitaxy (MOVPE) technique are determined. An approach to finding the optimal parameters of GaAs and In{sub 0.24}Ga{sub 0.76}As/GaAs photovoltaic converters in relation to the optical power being converted is suggested, and the structural parameters for incident-power values of 5, 20, and 50 W at wavelengths of 809 and 1064 nm are determined. It is found that, at laser-light intensities of up to 5 W, >60% efficiency can be achieved in laser-light conversion at a wavelength of 809 nm and >55% efficiency, at a wavelength of 1064 nm.

36 MATERIALS SCIENCE↗

Phase Separation in (Ga,Mn)As Layers Obtained by Ion Implantation and Subsequent Laser Annealing

In this paper, we present the results of studies of the spectral, temperature, and field dependences of the transversal Kerr effect in Ga{sub 1 –} {sub x}Mn{sub x}As (x = 0.0066–0.033) layers produced by ion implantation and subsequent pulsed laser annealing. The complicated nonmonotonous nature of the temperature dependences of the transversal Kerr effect and its dependence on the measurement range indicate a magnetic inhomogeneity of the layers. The reasons for the inhomogeneity can be the Gaussian distribution of Mn over the thickness of the layers and the electron phase separation in them. The appearance of new features in the spectra of the transversal Kerr effect is explained by the presence in the doped semiconductor matrix of nanoregions with a higher carrier concentration and a higher Curie temperature and a shift of the Fermi level into the valence band leading to an increase in the energy of optical transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Features of the Spectral Characteristics of Narrow-Band Optical Filters with Oblique Incidence of the Radiation Beam

The performance of narrow-band optical filters on the basis of frustrated total internal reflection was analyzed taking into account the Gaussian distribution of the angle of radiation incidence. The spectral characteristics of these optical filters are modelled with and without divergence of the incident beam. It is shown that, when measuring the spectral characteristics of optical filters, the divergence of the incident radiation beam should not be greater than a certain limit value that does not exceed several angular minutes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous depth determination of multiple objects by focus analysis in digital holography

Focus analysis techniques from computer vision are applied to digital holography to determine the depth (range) of multiple objects and their surfaces from a single hologram capture. With this method the depths of objects can be determined from a single hologram capture without the need for manual focusing and without prior information on object location. Variance and the Laplacian of Gaussian are analyzed as focus measures, and techniques are proposed for focus plane determination from the focus measure curves. The algorithm is described in detail and demonstrated through simulation and optical experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive thresholding and dynamic windowing method for automatic centroid detection of digital Shack-Hartmann wavefront sensor

A Shack-Hartmann wavefront sensor (SWHS) splits the incident wavefront into many subsections and transfers the distorted wavefront detection into the centroid measurement. The accuracy of the centroid measurement determines the accuracy of the SWHS. Many methods have been presented to improve the accuracy of the wavefront centroid measurement. However, most of these methods are discussed from the point of view of optics, based on the assumption that the spot intensity of the SHWS has a Gaussian distribution, which is not applicable to the digital SHWS. In this paper, we present a centroid measurement algorithm based on the adaptive thresholding and dynamic windowing method by utilizing image processing techniques for practical application of the digital SHWS in surface profile measurement. The method can detect the centroid of each focal spot precisely and robustly by eliminating the influence of various noises, such as diffraction of the digital SHWS, unevenness and instability of the light source, as well as deviation between the centroid of the focal spot and the center of the detection area. The experimental results demonstrate that the algorithm has better precision, repeatability, and stability compared with other commonly used centroid methods, such as the statistical averaging, thresholding, and windowing algorithms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous observations of giant pulses from pulsar PSR B0950+08 at 42 and 74 MHz

We report the detection of giant pulse (GP) emission from PSR B0950+08 in 12 hr of observations made simultaneously at 42 and 74 MHz, using the first station of the Long Wavelength Array. We detected 275 GPs (in 0.16% of the pulse periods) and 465 GPs (0.27%) at 42 and 74 MHz, respectively. The pulsar is weaker and produces less frequent GPs than at 100 MHz. Here, GPs are taken as having ⩾ 10 times the flux density of an average pulse (AP); their cumulative distribution of pulse strength follows a power law, with an index of −4.1 at 42 MHz and −5.1 at 74 MHz, which is much less steep than would be expected if we were observing the tail of a Gaussian distribution of normal pulses. We detected no other transient pulses in a wide dispersion measure range from 1 to 5000 pc cm{sup −3}. There were 128 GPs detected within the same periods from both 42 and 74 MHz, which means more than half of them are not generated in a wide band. The CLEAN-based algorithm was used to deconvolve the the effect of scattering broadening and we have concluded that the scattering effect from the interstellar medium at 42 and 74 MHz is weak and cannot be distinguished from the pulse profiles. We calculated the altitude r of the emission region using the dipolar magnetic field model. We found r(42 MHz) = 29.27 km (0.242% of R{sub LC}) and r(74 MHz) = 29.01 km (0.240% of R{sub LC}) for the AP, while for GPs, r(42 MHz) = 29.10 km (0.241% of R{sub LC}) and r(74 MHz) = 28.95 km (0.240% of R{sub LC}). GPs, which have a double-peak structure, have a smaller mean peak-to-peak separation compared to the AP.

79 ASTRONOMY AND ASTROPHYSICS↗