Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Focusing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Bubble Experiments on the Hydrodynamic Focusing Bioreactor-Space (HFB-S)

The Hydrodynamic Focusing Bioreactor-Space (HFB-S) is being developed as a drop-in replacement for the Rotating Wall Perfused Vessel (RWPV) bioreactor currently planned for use on the International Space Station (ISS). Only the vessel itself is proposed for change, the supporting hardware will remain the same. These bioreactors are used for the growth of three-dimensional tissue culture that cannot be done in normal gravity labs. The bioreactors provide a continual supply of oxygen for cell growth, as well as periodic replacement of cell culture media with nutrients. The RWPV has had many successful flights on the space shuttle, but longer duration missions onboard the Mir Space Station resulted in bubbles inside the vessel that were detrimental to the science. It is believed that procedural changes can prevent bubble formation, but the HFB-S must not only provide a mechanism of bubble removal, but must also meet strict requirements for a low-shear environment and uniform oxygen concentration distribution for optimum cell tissue growth. A detailed technical objective (DTO) flight on the space shuttle to fully evaluate the HFB-S is currently in the planning stages. Ground-based activities are also underway to quanitify the characteristics of the HFB-S. Computational studies are being used to predict the internal fluid flow and cell trajectories. These computations will be compared to ground-based flow visualization experiments. Comparative studies of ground-based cell growth between the RWPV and the HFB-S are also in progress. These studies have shown that the HFB-S functions well as a bioreactor in normal gravity. Bubble motion and bubble removal are being studied using computational predictions as well as experimental validation.

Charles Niederhaus↗

Focused Ion Beam Recovery and Analysis of Interplanetary Dust Particles (IDPs) and Stardust Analogues

Meteoritics research is a major beneficiary of recent developments in analytical instrumentation [1,2]. Integrated studies in which multiple analytical techniques are applied to the same specimen are providing new insight about the nature of IDPs [1]. Such studies are dependent on the ability to prepare specimens that can be analyzed in multiple instruments. Focused ion beam (FIB) microscopy has revolutionized specimen preparation in materials science [3]. Although FIB has successfully been used for a few IDP and meteorite studies [1,4-6], it has yet to be widely utilized in meteoritics. We are using FIB for integrated TEM/NanoSIMS/synchrotron infrared (IR) studies [1].

Graham, G. A.↗

Focused Assessment with Sonography for Trauma in weightlessness: a feasibility study

BACKGROUND: The Focused Assessment with Sonography for Trauma (FAST) examines for fluid in gravitationally dependent regions. There is no prior experience with this technique in weightlessness, such as on the International Space Station, where sonography is currently the only diagnostic imaging tool. STUDY DESIGN: A ground-based (1 g) porcine model for sonography was developed. We examined both the feasibility and the comparative performance of the FAST examination in parabolic flight. Sonographic detection and fluid behavior were evaluated in four animals during alternating weightlessness (0 g) and hypergravity (1.8 g) periods. During flight, boluses of fluid were incrementally introduced into the peritoneal cavity. Standardized sonographic windows were recorded. Postflight, the video recordings were divided into 169 20-second segments for subsequent interpretation by 12 blinded ultrasonography experts. Reviewers first decided whether a video segment was of sufficient diagnostic quality to analyze (determinate). Determinate segments were then analyzed as containing or not containing fluid. A probit regression model compared the probability of a positive fluid diagnosis to actual fluid levels (0 to 500 mL) under both 0-g and 1.8-g conditions. RESULTS: The in-flight sonographers found real-time scanning and interpretation technically similar to that of terrestrial conditions, as long as restraint was maintained. On blinded review, 80% of the recorded ultrasound segments were considered determinate. The best sensitivity for diagnosis in 0 g was found to be from the subhepatic space, with probability of a positive fluid diagnosis ranging from 9% (no fluid) to 51% (500 mL fluid). CONCLUSIONS: The FAST examination is technically feasible in weightlessness, and merits operational consideration for clinical contingencies in space.

NASA Discipline Life Sciences Technologies↗

Gamma-Ray Focusing Optics for Small Animal Imaging

There is a well-established need for high-resolution radionuclide imaging techniques that provide non-invasive measurement of physiological function in small animals. We, therefore, have begun developing a small animal radionuclide imaging system using grazing incidence mirrors to focus low-energy gamma-rays emitted by I-125, and other radionuclides. Our initial prototype optic, fabricated from thermally-formed glass, demonstrated a resolution of 1500 microns, consistent with the performance predicted by detailed simulations. More recently, we have begun constructing mirrors using a replication technique that reduces low spatial frequency errors in the mirror surface, greatly improving the resolution. Each technique offers particular advantages: e.g., multilayer coatings are easily deposited on glass, while superior resolution is possible with replicated optics. Scaling the results from our prototype optics, which only have a few nested shells, to system where the lens has a full complement of several tens of nested shells, a sensitivity of approx. 1 cps/micro Ci is possible, with the exact number dependent on system magnification and radionuclide species. (Higher levels of efficiency can be obtained with multi-optic imaging systems.) The gamma-ray lens will achieve a resolution as good as 100 microns, independent of the final sensitivity. The combination of high spatial resolution and modest sensitivity will enable in vivo single photon emission imaging studies in small animals.

Pivovaroff, M. J.↗

The Development of Focusing Telescopes for the Hard-X-Ray Region

Grazing-incidence optics has revolutionized soft-x-ray astronomy yet the scientifically-important hard-x-ray region has gone relatively unexplored at high sensitivity and fine angular scales. This situation is now changing with several flight-ready balloon-borne focusing telescopes and planned satellite-borne observatories, This review will discuss some of the developments in mirror and focal plane technologies that are making these payloads possible.

Ramsey, Brian D.↗

Focused Ion Beam Microscopy of ALH84001 Carbonate Disks

Our aim is to understand the mechanism(s) of formation of carbonate assemblages in ALH84001. A prerequisite is that a detailed characterization of the chemical and physical properties of the carbonate be established. We present here analyses by transmission electron microscopy (TEM) of carbonate thin sections produced by both focused ion beam (FIB) sectioning and ultramicrotomy. Our results suggest that the formation of ALH84001 carbonate assemblages were produced by considerably more complex process(es) than simple aqueous precipitation followed by partial thermal decomposition as proposed by other investigators [e.g., 1-3].

Thomas-Keprta, Kathie L.↗

New Technology-Large-Area Three- Dimensional Surface Profiling Using Only Focused Air-Coupled Ultrasound-Given 1999 R&D 100 Award

Surface topography, which significantly affects the performance of many industrial components, is normally measured with diamond-tip profilometry over small areas or with optical scattering methods over larger areas. To develop air-coupled surface profilometry, the NASA Glenn Research Center at Lewis Field initiated a Space Act Agreement with Sonix, Inc., through two Glenn programs, the Advanced High Temperature Engine Materials Program (HITEMP) and COMMTECH. The work resulted in quantitative surface topography profiles obtained using only high-frequency, focused ultrasonic pulses in air. The method is nondestructive, noninvasive, and noncontact, and it does not require light-reflective surfaces. Air surface profiling may be desirable when diamond-tip or laserbased methods are impractical, such as over large areas, when a significant depth range is required, or for curved surfaces. When the configuration is optimized, the method is reasonably rapid and all the quantitative analysis facilities are online, including two- and three-dimensional visualization, extreme value filtering (for faulty data), and leveling.

Roth, Don J.↗

Microwave and Millimeter Wave Imaging of the Space Shuttle External Fuel Tank Spray on Foam Insulation (SOFI) Using Synthetic Aperture Focusing Techniques (SAFT)

The Space Shuttle Columbia's catastrophic failure is thought to have been caused by a dislodged piece of external tank SOFI (Spray On Foam Insulation) striking the left wing of the orbiter causing significant damage to some of the reinforced carbodcarbon leading edge wing panels. Microwave and millimeter wave nondestructive evaluation methods, have shown great potential for inspecting the SOFI for the purpose of detecting anomalies such as small voids that may cause separation of the foam from the external tank during the launch. These methods are capable of producing relatively high-resolution images of the interior of SOH particularly when advanced imaging algorithms are incorporated into the overall system. To this end, synthetic aperture focusing techniques are being deveioped for this purpose. These iechniqiies pradiice high-resolution images that are independent of the distance of the imaging probe to the SOFI with spatial resolution in the order of the half size of imaging probe aperture. At microwave and millimeter wave frequencies these apertures are inherently small resulting in high-resolution images. This paper provides the results of this investigation using 2D and 3D SAF based methods and holography. The attributes of these methods and a full discussion of the results will also be provided.

Case, J. T.↗

Microwave and Millimeter Wave Imaging of the Space Shuttle External Fuel Tank Spray on Foam Insulation (SOFI) using Synthetic Aperture Focusing Techniques (SAFT}

The Space Shuttle Columbia s catastrophic failure is thought to have been caused by a dislodged piece of external tank spray on foam insulation (SOFI) striking the left wing of the orbiter causing significant damage to some of the reinforced carbodcarbon leading edge wing panels. Microwave and millimeter wave nondestructive evaluation methods have shown great potential for inspecting SOFI for the purpose of detecting anomalies such as small air voids that may cause separation of the SOFI from the external tank during a launch. These methods are capable of producing relatively high-resolution images of the interior of SOFI particularly when advanced imaging algorithms are incorporated into the overall system. To this end, synthetic aperture focusing techniques (SAFT) are being developed. This paper presents some of the preliminary results of this investigation using SAFT-based methods and microwave holography at relatively low frequencies illustrating their potential capabilities for operation at millimeter wave frequencies.

Case, J. T.↗

Fast prototyping of high-aspect ratio, high-resolution x-ray masks by gas-assisted focused ion beam

The capacity of chemically-assisted focused ion beam (fib) etching systems to undertake direct and highly anisotropic erosion of thin and thick gold (or other high atomic number [Z])coatings on x-ray mask membranes/substrates provides new levels of precision, flexibility, simplification and rapidity in the manufacture of mask absorber patterns, allowing the fast prototyping of high aspect ratio, high-resolution masks for deep x-ray lithography.

fast prototyping of high-aspect ratio high-resolut↗

Scattering of a Tightly Focused Beam by an Optically Trapped Particle

Near-forward scattering of an optically trapped 5 m radius polystyrene latex sphere by the trapping beam was examined both theoretically and experimentally. Since the trapping beam is tightly focused, the beam fields superpose and interfere with the scattered fields in the forward hemisphere. The observed light intensity consists of a series of concentric bright and dark fringes centered about the forward scattering direction. Both the number of fringes and their contrast depend on the position of the trapping beam focal waist with respect to the sphere. The fringes are caused by diffraction due to the truncation of the tail of the trapping beam as the beam is transmitted through the sphere.

Lock, James A.↗

Lunar e-Library: A Research Tool Focused on the Lunar Environment

As NASA plans and implements the Vision for Space Exploration, managers, engineers, and scientists need lunar environment information that is readily available and easily accessed. For this effort, lunar environment data was compiled from a variety of missions from Apollo to more recent remote sensing missions, such as Clementine. This valuable information comes not only in the form of measurements and images but also from the observations of astronauts who have visited the Moon and people who have designed spacecraft for lunar missions. To provide a research tool that makes the voluminous lunar data more accessible, the Space Environments and Effects (SEE) Program, managed at NASA's Marshall Space Flight Center (MSFC) in Huntsville, AL, organized the data into a DVD knowledgebase: the Lunar e-Library. This searchable collection of 1100 electronic (.PDF) documents and abstracts makes it easy to find critical technical data and lessons learned from past lunar missions and exploration studies. The SEE Program began distributing the Lunar e-Library DVD in 2006. This paper describes the Lunar e-Library development process (including a description of the databases and resources used to acquire the documents) and the contents of the DVD product, demonstrates its usefulness with focused searches, and provides information on how to obtain this free resource.

McMahan, Tracy A.↗

Human Bone-Forming Chondrocytes Cultured in the Hydrodynamic Focusing Bioreactor Retain Matrix Proteins: Similarities to Spaceflight Results

Fracture healing, crucial to a successful Mars mission, involves formation of a cartilaginous fracture callus which differentiates, mineralizes, ossifies and remodels via the endochondral process. Studies of spaceflown and tailsuspended rats found that, without loading, fracture callus formation and cartilage differentiation within the callus were minimal. We found delayed differentiation of chondrocytes within the rat growth plate on Cosmos 1887, 2044, and Spacelab 3. In the current study, differentiation of human bone-forming chondrocytes cultured in the hydrodynamic focusing bioreactor (HFB) was assessed. Human costochondral chondrocytes in suspension were aggregated overnight, then cultured in the HFB for 25 days. Collagen Type II, aggrecan and unsulfated chondroitin were found extracellularly and chondroitin sulfates 4 and 6 within the cell. Lack of secretion was also found in pancreatic cells of spaceflown rats, and in our SL3 studies. The HFB can be used to study cartilage differentiation in simulated microgravity.

Duke, P. J.↗

Comparison of Focused and Near-Field Imaging of Spray on Foam Insulation (SOFI) at Millimeter Wave Frequencies

The Space Shuttle Columbia's catastrophic accident was due to a piece of Spray on Foam Insulation (SOFI) that broke off from the external tank and damaged the leading edge of the orbiter's left wing. Millimeter wave focused and near-field imaging methods have been suessfully used for inspecting of the SOFI samples. Comparison between these methods for the purpose of detection and evaluation of flaws in the SOFI is provided using examples of images of SOFI samples.

Kharkovsky, S.↗

Rotating apparatus for isoelectric focusing

This disclosure is directed to an isoelectric focusing apparatus, wherein stabilization of the fluid containing the isolated proteins is achieved by carrying out the separation in a rotating cylinder with the separation cavity of the cylinder being segmented by means of filter elements. The filter elements are constituted of a material offering some degree of resistance to fluid convection, but allowing relatively free and unhindered passage of current and transport of proteins. The combined effect of segmentation and rotation has been found to be superior to either segmentation or rotation alone in maintaining the stability of the migrated fractions.

Bier, Milan↗

Focused Ion Beam Recovery of Hypervelocity Impact Residue in Experimental Craters on Metallic Foils

The Stardust sample return capsule will return to Earth in January 2006 with primitive debris collected from Comet 81P/Wild-2 during the fly-by encounter in 2004. In addition to the cometary particles embedded in low-density silica aerogel, there will be microcraters preserved in the Al foils (1100 series; 100 micrometers thick) that are wrapped around the sample tray assembly. Soda lime spheres (approximately 49 m in diameter) have been accelerated with a light-gas-gun into flight-grade Al foils at 6.35 km s(sup -1) to simulate the potential capture of cometary debris. The preserved crater penetrations have been analyzed using scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDX) to locate and characterize remnants of the projectile material remaining within the craters. In addition, ion beam induced secondary electron imaging has proven particularly useful in identifying areas within the craters that contain residue material. Finally, high-precision focused ion beam (FIB) milling has been used to isolate and then extract an individual melt residue droplet from the interior wall of an impact penetration. This enabled further detailed elemental characterization, free from the background contamination of the Al foil substrate. The ability to recover pure melt residues using FIB will significantly extend the interpretations of the residue chemistry preserved in the Al foils returned by Stardust.

Graham, G. A.↗

HERO: A Hard-X-Ray Balloon-Borne Focusing Telescope

HERO, for High Energy Replicated Optics, is an evolutionary balloon payload featuring hard-X-ray grazing-incidence nickel optics. The payload provides a scientific instrument capable of high-sensitivity observations in an energy regime that is relatively unexplored at fine spatial scales, and also serves as a demonstration vehicle for in-house fabricated optics and focal plane detectors. After a proof-of-concept flight in 2001, which captured the first focused hard-X-ray images galactic sources, HERO has been significantly expanded from just 6, 3-m-focal length mirror shells to its current complement of nearly 100, 6-m-focal length mirrors. HERO was flown in 2007, from Fort Sumner, NM, and is scheduled to fly again in September 2009, from Alice Springs, NT. Full details of the payload will be provided along with preliminary data from the previous flight and science targets for the next flight, where the galactic center region will be imaged.

Ramsey, Brian↗