Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Gadolinium-loaded gel scintillators for neutron and antineutrino detection

A gadolinium (Gd) loaded scintillation gel (Gd-ScintGel) compound allows for neutron and gamma-ray detection. The unique gel scintillator encompasses some of the best features of both liquid and solid scintillators, yet without many of the disadvantages associated therewith. Preferably, the gel scintillator is a water soluble Gd-DTPA compound and water soluble fluorophores such as: CdSe/ZnS (or ZnS) quantum dot (Q-dot) nanoparticles, coumarin derivatives 7-hydroxy-4-methylcoumarin, 7-hydroxy-4-methylcoumarin-3-acetic acid, 7-hydroxycoumarin-3-carboxylic acid, and Alexa Fluor 350 as well as a carbostyril compound, carbostyril 124 in a stable water-based gel, such as methylcellulose or polyacrylamide polymers. The Gd-loaded ScintGel allows for a homogenious distribution of the Gd-DTPA and the fluorophores, and yields clean fluorescent emission peaks. A moderator, such as deuterium or a water-based clear polymer, can be incorporated in the Gd-ScintGel. The gel scintillators can be used in compact detectors, including neutron and antineutrino detectors.

36 MATERIALS SCIENCE↗

Further Investigations of the Effect of Replacing Lithium by Sodium on Lithium Silicate Scintillating Glass Efficiency

Ce3+ doped lithium (6Li) silicate glasses are thermal neutron detectors. Prior work showed that when sodium (Na) is substituted for Li the scintillation efficiency, under beta particle stimulation, increased and then decreased as the sodium (Na) content was increased [1]. When all the 6Li was replaced by Na no scintillation was observed. Raman spectra, acquired using a visible excitation source provided no evidence of anomalous behavior. SEM microscopy did show some phase separation, but there was no obvious correlation with the scintillation efficiency. We have reexamined these glass samples using deep UV Raman excitation which reduces fluorescence interference. The newly acquired spectra show evidence of phase separation in the glasses. Specifically we see a peak at 800 cm-1 Raman shift which can be assigned to a vitreous silica moiety that results from phase separation. There is a strong correlation between this peak's area, the scintillation efficiency, and the Na content. The observed trend suggests that phase separation enhances scintillation and addition of Na reduces the amount of phase separation. We also see evidence of at least two defect structures that can be tentatively assigned to a three-membered ring structure and an oxygen vacancy. The latter is fairly strongly correlated with enhanced scintillation efficiency.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A New Protein-Protein Interaction Sensor Based on Tripartite Split-GFP Association

Monitoring protein-protein interactions in living cells is key to unraveling their roles in numerous cellular processes and various diseases. Previously described split-GFP based sensors suffer from poor folding and/ or self-assembly background fluorescence. Here, we have engineered a micro-tagging system to monitor protein-protein interactions in vivo and in vitro. The assay is based on tripartite association between two twenty amino-acids long GFP tags, GFP10 and GFP11, fused to interacting protein partners, and the complementary GFP1-9 detector. When proteins interact, GFP10 and GFP11 self-associate with GFP1-9 to reconstitute a functional GFP. Using coiled-coils and FRB/FKBP12 model systems we characterize the sensor in vitro and in Escherichia coli. We extend the studies to mammalian cells and examine the FK-506 inhibition of the rapamycin-induced association of FRB/FKBP12. The small size of these tags and their minimal effect on fusion protein behavior and solubility should enable new experiments for monitoring protein-protein association by fluorescence.

36 MATERIALS SCIENCE↗

Intelligent Integrated Machining: Handheld XRF for Mapping Zr Coating and Al-6061 Cladding Thickness in RERTR Fuel Elements

An inexpensive commercially available handheld energy dispersive x‐ray fluorescence spectrometer is used to provide a rapid non‐destructive estimate of coating and/or cladding thickness in situ . The portable XRF instrument contains a battery‐operated low‐power polychromatic source coupled with a Peltier‐cooled silicon drift detector; built‐in analysis software based upon the Method of Fundamental Parameters converts measured spectral intensities to elemental concentrations, reported as normalized weight percentages. Using detected signals from elements unique to the base material and coating or cladding materials, calibration curves and associated empirical algorithms for determining the thickness of the high‐purity zirconium coating on an RERTR fuel element prior to cladding with aluminum, and for determining the thickness of the Al‐6061 cladding after HIP for a known zirconium layer thickness, are constructed. For Zr over bare DU‐10Mo, agreement between the measured and the calculated thickness is ± 5% or better. For the multilayer system consisting of Al‐6061 over Zr over Du‐10Mo, agreement between calculated and measured thickness is ± 10‐15% over the thickness range of interest. Simultaneous estimates for the Al cladding and underlying Zr coating can be made using the elemental composition output only when the Mo signal is in the quasi‐static range (corresponding to Al thicknesses of ~15 mils (0.381 mm) and greater) and not so low that measurement error is greater than the signal itself; under these conditions, accuracy is on the order of ±15 – 20%. More accurate determination of both Zr and Al thickness simultaneously may be possible if the count‐rates associated with individual fluorescent lines in the multilayer sample are available rather than just the weight percent composition currently output by the XRF analyzer software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improving the counting efficiency in time-correlated single photon counting experiments by dead-time optimization

Time-Correlated Single Photon Counting (TCSPC) has been long recognized as the most sensitive method for fluorescence lifetime measurements, but often requiring “long” data acquisition times. This drawback is related to the limited counting capability of the TCSPC technique, due to pile-up and counting loss effects. In recent years, multi-module TCSPC systems have been introduced to overcome this issue. Splitting the light into several detectors connected to independent TCSPC modules proportionally increases the counting capability. Of course, multi-module operation also increases the system cost and can cause space and power supply problems. In this paper, we propose an alternative approach based on a new detector and processing electronics designed to reduce the overall system dead time, thus enabling efficient photon collection at high excitation rate. We present a fast active quenching circuit for single-photon avalanche diodes which features a minimum dead time of 12.4 ns. We also introduce a new Time-to-Amplitude Converter (TAC) able to attain extra-short dead time thanks to the combination of a scalable array of monolithically integrated TACs and a sequential router. The fast TAC (F-TAC) makes it possible to operate the system towards the upper limit of detector count rate capability (∼80 Mcps) with reduced pile-up losses, addressing one of the historic criticisms of TCSPC. Preliminary measurements on the F-TAC are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron beam characterization via quantum coherent electric field imaging

We demonstrate an all-optical, minimally invasive electron beam (𝑒−beam) characterization using Rydberg electrometry. An 𝑒-beam passes through a localized detector volume containing thermal Rb atoms that are optically excited in a quantum superposition of ground and Rydberg states. The 𝑒-beam's electric field perturbs atomic coherence and modifies resonance fluorescence in a narrow spectral region near the two-photon optical transition. Imaging Rb fluorescence provides a map of the electric field from the 𝑒-beam via Rydberg state Stark shifts and allows us to reconstruct the 𝑒-beam width, centroid position, and current. For an 𝑒-beam of 20 keV and electron currents of 20–40 µ⁢A, we measured the centroid position with an accuracy of ≤ 8 µ⁢m and width to within 100 µ⁢m, limited by the experimental sensitivity of electric field reconstruction of ∼0.02 V/cm. This method is suitable for a wide range of electron energies and currents, and can be adopted for nuclear and high-energy experiments for minimally invasive real-time diagnostics and profiling of charged particle beams.

Behary, Rob [College of William and Mary, Williams↗

Low cost solar array project: Composition measurements by analytical photon catalysis

The applicability of the photon catalysis technique for effecting composition analysis of silicon samples is assessed. In particular, the technique is to be evaluated as a detector for the impurities Al, Cr, Fe, Mn, Ti, V, Mo and Zr. During the first reporting period Al, Cr, Fe and Mn were detected with the photon catalysis method. The best fluorescence lines to monitor and determined initial sensitivities to each of these elements by atomic absorption calibration were established. In the course of these tests, vapor pressure curves for these four pure substances were mapped.

Sutton, D. G.↗

Experimental Resonance Enhanced Multiphoton Ionization (REMPI) studies of small molecules

Resonance enhanced multiphoton ionization (REMPI) utilizes tunable dye lasers to ionize an atom or molecule by first preparing an excited state by multiphoton absorption and then ionizing that state before it can decay. This process is highly selective with respect to both the initial and resonant intermediate states of the target, and it can be extremely sensitive. In addition, the products of the REMPI process can be detected as needed by analyzing the resulting electrons, ions, fluorescence, or by additional REMPI. This points to a number of exciting opportunities for both basic and applied science. On the applied side, REMPI has great potential as an ultrasensitive, highly selective detector for trace, reactive, or transient species. On the basic side, REMPI affords an unprecedented means of exploring excited state physics and chemistry at the quantum-state-specific level. An overview of current studies of excited molecular states is given to illustrate the principles and prospects of REMPI.

Dehmer, J. L.↗

Development and applications of laser-induced incandescence

Several NASA-funded investigations focus on soot processes and radiative influences of soot in diffusion flames given their simplicity, practical significance, and potential for theoretical modeling. Among the physical parameters characterizing soot, soot volume fraction, f(sub v), a function of particle size and number density, is often of chief practical interest in these investigations, as this is the geometrical property that directly impacts radiative characteristics and the temperature field of the flame and is basic to understanding soot growth and oxidation processes. Diffusion flames, however, present a number of challenges to the determination of f(sub v) via traditional extinction measurements. Laser-induced incandescence (LII) possesses several advantages compared to line-of-sight extinction techniques for determination of f(sub v). Since LII is not a line-of-sight technique, similar to fluorescence, it possesses geometric versatility allowing spatially resolved measurements of f(sub v) in real time in nonaxisymmetric systems without using deconvolution techniques. The spatial resolution of LII is determined by the detector and imaging magnification used. Neither absorption by polycyclic aromatic hydrocarbons (PAH's) nor scattering contributes to the signal. Temporal capabilities are limited only by the laser pulse and camera gate duration, with measurements having been demonstrated with 10 ns resolution. Because of these advantages, LII should be applicable to a variety of combustion processes involving both homogeneous and heterogeneous phases. Our work has focussed on characterization of the technique as well as exploration of its capabilities and is briefly described.

Vanderwal, Randy L.↗

The Focal Surface of the JEM-EUSO Telescope

Extreme Universe Space Observatory onboard JEM/EP (JEM-EUSO) is a space mission to study extremely high-energy cosmic rays. The JEM-EUSO instrument is a wide-angle refractive telescope in near-ultraviolet wavelength region to observe time-resolved atmospheric fluorescence images of the extensive air showers from the International Space Station. The focal surface is a spherical curved surface, and its area amounts to about 4.5 square m. The focal surface detector is covered with about 6,000 multi-anode photomultipliers (MAPMTs). The focal surface detector consists of Photo-Detector-Modules, each of which consists of 9 Elementary Cells (ECs). The EC contains 4 units of the MAPMTs. Therefore, about 1,500 ECs or about 160 PDMS are arranged on the whole of the focal surface of JEM- EUSO. The EC is a basic unit of the front-end electronics. The PDM is a, basic unit of the data acquisition system

Kawasaki, Yoshiya↗

Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

43 PARTICLE ACCELERATORS↗

K-Shell X-Ray Fluorescence Parameters of a Few Low Z Elements

K-shell X-ray fluorescence parameters of low Z elements cobalt, nickel, copper, and zinc have been measured employing a simple method. These elemental targets were excited by using 32.86 keV barium K X-ray photons from a weak {sup 137}Cs γ-ray source, and the emitted K-shell X-rays from these targets were detected using a low-energy high-purity germanium X-ray detector spectrometer. The results are compared with the standard theoretical, semi-empirical, fitted values and with the others’ experimental values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. In addition, an efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent in the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.

36 MATERIALS SCIENCE↗

Nuclear Science Symposium, 29th, and Symposium on Nuclear Power, 14th, Washington, DC, October 20-22, 1982, Proceedings

High-energy radiation detectors suitable for balloon-borne or space-based radiation event studies are described. The employment of NaI(Tl) scintillator bars for gamma ray detection is outlined, and the development of a fluorescent gated gas-filled scintillation proportional counter is reported. A high throughput nondispersive hard X ray spectrograph with angular resolution for cosmic bursts, transients, and sources has been constructed. Features of a sealed high pressure xenon filled imaging proportional counter with a 30 sq cm sensitive area are explored. Finally, the various radiation effects on electronic circuitry in a space environment are defined, and an MOS dosimeter for assaying the cumulative radiation flux in a spacecraft due to ambient conditions is characterized.

Davis, W. D.↗

Monitor for measuring mercury emissions

A mercury emissions monitor includes a mercury sensor tape configured to be fed in a reel-to-reel manner between first and second tape reels, wherein the mercury sensor tape includes a thin metallic film configured to form an amalgam with detected mercury. A mercury collection unit is configured to receive into a chamber a sample of a gas containing mercury, wherein the mercury collection unit is further configured to permit passage of portions of the mercury sensor tape through the chamber containing the gas sample so that the amalgam is formed with the thin metallic film. A mercury analysis unit includes a total reflection x-ray fluorescence (“TXRF”) system configured to perform a TXRF analysis of the amalgam, wherein the mercury analysis unit is configured to permit passage of the mercury sensor tape within a proximity of an XRF detector of the TXRF system. The mercury collection unit and the mercury analysis unit are positioned between the first and second tape reels so that the mercury sensor tape can move in a continuous manner from the first tape reel through the chamber of the mercury collection unit, then within sufficient proximity to the XRF detector, to be then taken up onto the second tape reel.

Kumar, Nalin↗

Fluorescence Correlation Spectroscopy at Micromolar Concentrations without Optical Nanoconfinement

Fluorescence correlation spectroscopy (FCS) is an important technique for studying biochemical interactions dynamically that may be used in vitro and in cell-based studies. It is generally claimed that FCS may only be used at nM concentrations. We show that this general consensus is incorrect and that the limitation to nM concentrations is not fundamental but due to detector limits as well as laser fluctuations. With a high count rate detector system and applying laser fluctuation corrections, we demonstrate FCS measurements up to 38 μM with the same signal-to-noise as at lower concentrations. Optical nanoconfinement approaches previously used to increase the concentration range of FCS are not necessary, and further increases above 38 μM may be expected using detectors and detector arrays with higher saturation rates and better laser fluctuation corrections. This approach greatly widens the possibilities of dynamic measurements of biochemical interactions using FCS at physiological concentrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon scattering from strongly driven atomic ensembles

The second-order correlation function for light emitted from a strongly and near-resonantly driven dilute cloud of atoms is discussed. Because of the strong driving, the fluorescence spectrum separates into distinct peaks, for which the spectral properties can be defined individually. It is shown that the second-order correlations for various combinations of photons from different spectral lines exhibit bunching together with super-Poissonian or sub-Poissonian photon statistics, tunable by the choice of the detector positions. Additionally, a Cauchy-Schwarz inequality is violated for photons emitted from particular spectral bands. The emitted light intensity is proportional to the square of the number of particles, and thus can potentially be intense. Three different averaging procedures to model ensemble disorder are compared.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fast, High-Resolution X-ray Microfluorescence Imaging

X-ray micro fluorescence imaging refers to the use of an x-ray beam as a probe to excite XRF in a specimen and produce a spatially resolved image of the element distribution. The advantages of high sensitivity and low background, together with the nondestructive nature of the measurement, have lead to applications of x-ray microfluorescence analysis in biology, geology, materials science, as well as in the area of nondestructive evaluation. Previous reports have described the development of an x-ray microprobe which uses a conventional source of x-rays to produce a 10-μm beam. This paper describes improvements to the microprobe which have increased the beam power and the solid angle of detection. The data collection and display software have also been enhanced.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗