Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Plasma parameters and electromagnetic forces induced by the magneto hydro dynamic interaction in a hypersonic argon flow experiment

This work proposes an experimental analysis on the magneto hydro dynamic (MHD) interaction induced by a magnetic test body immersed into a hypersonic argon flow. The characteristic plasma parameters are measured. They are related to the voltages arising in the Hall direction and to the variation of the fluid dynamic properties induced by the interaction. The tests have been performed in a hypersonic wind tunnel at Mach 6 and Mach 15. The plasma parameters are measured in the stagnation region in front of the nozzle of the wind tunnel and in the free stream region at the nozzle exit. The test body has a conical shape with the cone axis in the gas flow direction and the cone vertex against the flow. It is placed at the nozzle exit and is equipped with three permanent magnets. In the configuration adopted, the Faraday current flows in a closed loop completely immersed into the plasma of the shock layer. The electric field and the pressure variation due to MHD interaction have been measured on the test body walls. Microwave adsorption measurements have been used for the determination of the electron number density and the electron collision frequency. Continuum recombination radiation and line radiation emissions have been detected. The electron temperature has been determined by means of the spectroscopic data by using different methods. The electron number density has been also determined by means of the Stark broadening of H{sub {alpha}} and the H{sub {beta}} lines. Optical imaging has been utilized to visualize the pattern of the electric current distribution in the shock layer around the test body. The experiments show a considerable effect of the electromagnetic forces produced by the MHD interaction acting on the plasma flow around the test body. A comparison of the experimental data with simulation results shows a good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flow of superfluid helium in tubes with heated walls

The equations for superfluid helium flowing through a straight tube with heated walls are integrated. The model equations are based on those of Landau as modified for superfluid turbulence by Gorter and Mellink (1949). The model is implemented by the program SUPERFLOW which runs on a personal computer. The effect of the heating level on the mass flux, the energy flux, and the pressure and temperature profiles is investigated. The four types of profiles which occur without sidewall heating are also found with heated walls. The progression through these four types is shown to depend primarily on the dimensionless parameter, defined previously to characterize the unheated profiles, and a dimensionless ratio of heat fluxes. The pressure and temperature maxima which rise well above the boundary values increase significantly with sidewall heating. Approximate design equations for estimating the mass flux and the profiles are presented. The physical basis of the results is discussed. These results are useful in the design of optimal cooling loops and other superfluid flow systems.

Snyder, H. A.↗

Liquid metal compatibility of pre-oxidized FeCrAl in flowing Sn

Here, a flowing Sn thermal convection loop (TCL) experiment was conducted in FeCrAlMo (Kanthal alloy APMT) tubing for 1000 h with a peak temperature of 400 °C. Oxide dispersion strengthened (ODS) Fe-(10–12)Cr-6Al and APMT specimens were exposed and all were pre-oxidized to form an external alumina scale. Unlike static exposures at 400° and 500 °C where pre-oxidation prevented dissolution, large mass losses were observed in the TCL hot leg after the specimens were cleaned in Li. The observed pitting suggests that localized failure of the pre-formed alumina surface oxide caused significant metal loss. Specimen mass gains were not observed on the cold leg implying that mass transfer did not occur and the small levels of Fe and Cr in the Sn after the experiment implies that Sn-rich phases may have formed. Post exposure room temperature tensile testing showed limited impact of the Sn exposure on the 12Cr ODS FeCrAl alloy, comparable to a 1000 h anneal in Ar at 400 °C. These results suggest that pre-oxidation is not sufficient to protect FeCrAl alloys in contact with flowing liquid Sn at 350°-400 °C.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dislocation half-loop control for optimal V-defect density in GaN-based light emitting diodes

V-defects are morphological defects that typically form on threading dislocations during epitaxial growth of $(0001)$-oriented GaN layers. A V-defect is a hexagonal pyramid-shaped depression with six {$10\bar{1}1$}-oriented sidewalls. These semipolar sidewalls have a lower polarization barrier than the polarization barriers present between the polar c-plane quantum wells and quantum barriers and can laterally inject carriers directly into quantum wells in GaN-based light emitting diodes (LEDs). This is especially important, as the high polarization field in c-plane GaN is a significant factor in the high forward voltage of GaN LEDs. The optimal V-defect density for efficient lateral carrier injection in a GaN LED (∼10 9 cm −2 ) is typically an order of magnitude higher than the threading dislocation density of GaN grown on patterned sapphire substrates (∼10 8 cm −2 ). Pure-edge dislocation loops have been known to exist in GaN, and their formation into large V-defects via low-temperature growth with high Si-doping has recently been studied. Here, in this work, we develop a method for pure-edge threading dislocation half-loop formation and density control via disilane flow, growth temperature, and thickness of the half-loop generation layer. We also develop a method of forming the threading dislocation half-loops into V-defects of comparable size to those originating from substrate threading dislocations.

Crystallographic defects↗

Hydraulic model of the proposed Water Recovery and Management system for Space Station Freedom

A model of the Water Recovery and Management (WRM) system utilizing SINDA '85/FLUINT to determine its hydraulic operation characteristics, and to verify the design flow and pressure drop parameters is presented. The FLUINT analysis package is employed in the model to determine the flow and pressure characteristics when each of the different loop components is operational and contributing to the overall flow pattern. The water is driven in each loop by storage tanks pressurized with cabin air, and is routed through the system to the desired destination.

Martin, Charles E.↗

Performance study of charcoal-based radon reduction systems for ultraclean rare event detectors

The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. 222 Rn produces a particularly problematic background in the physics region of interest by the "naked" beta decay of its 214 Pb daughter nucleus. While charcoal-based adsorption traps are expected to be effective for radon reduction in auxiliary circulation loops that service the warm components of current ton-scale detectors at slow flow rates (0.5-2 SLPM), radon reduction in the entire circulation loop at high flow rates $\mathcal{O}$(100s SLPM) is necessary to reach high sensitivity in future generation experiments. In this article we explore radon dynamics with a charcoal-based radon reduction system in the main circulation loop of time projection chamber detectors. Here, we find that even for perfect radon traps, circulation speeds of 2,000 SLPM are needed to reduce radon concentration in a 10 ton detector by 90%. This is faster by a factor of four than the highest circulation speeds currently achieved in dark matter detectors. We further find that the effectiveness of vacuum swing adsorption systems, which have been employed very successfully at reducing atmospheric radon levels in clean-rooms, is limited by the intrinsic radon activity of the charcoal adsorbent in ultra-low radon environments. Adsorbents with significantly lower intrinsic radon activity than in currently available activated charcoals would be necessary to build effective vacuum swing adsorption systems operated at room temperature for rare event search experiments. If such VSA systems are cooled to about 190 K, this requirement relaxes drastically.

47 OTHER INSTRUMENTATION↗

Helium Degassing Filter for Mercury Process Gas Liquid Separator

Testing was conducted to find a suitable filter to help separate helium gas from the Spallation Neutron Source’s mercury process loop. This filter is proposed for installation on the gas-liquid separator (GLS) vent line to prevent a column of liquid mercury from flowing outside of the process loop shielding in the service bay. The filter’s desired properties are to prevent the passage of liquid mercury, provide minimal resistance to helium flow, resist radiation, operate for the lifetime of the target, be replaceable, and have a reliable construction. Testing concluded that the Mott Corporation POU-10-S series of filters provided the best performance available. The filters could stop most liquid mercury passage while allowing helium passage at nominal pressures above the GLS in standard conditions. This result has several implications for the design of the GLS vent system.

Weinmeister, Justin↗

A network model for natural ventilation simulation in deep buried underground structures

The study of underground natural ventilation opportunities has become increasingly significant in recent years with its promise of wide application in underground structures such as underground hydro power stations, metro stations, underground parking and laboratories. It is recognized that deployment of natural ventilation constitutes a passive technology that can lead to significant energy conservation if applied judiciously. This paper focuses on underground buildings that are buried deeply and typically consist of an underground complex network of connected structures. The other characteristic is that these structures house machinery and devices that generate heat, leading to elevated internal air temperatures. Combined with the deep location, it implies that buoyancy forces are significant which make natural ventilation through vertical shaft openings a viable option. These characteristics demand a study of the heat transfer processes between ambient conditions, soil and underground buildings. In this paper, we present a dynamic flow network model with loops for multizone airflow and apply it to deep buried underground structures considering the dominant heat transfer characteristics, not only through the elements of the network but also the heat exchange with the envelope and adjacent soil mass. Finally, a small-scale experiment of occurring airflow is conducted and compared with the outcomes of the dynamic simulation of the proposed model. The comparison serves as validation and illustration of the application potential of the network model for natural ventilation investigation and consecutive optimization of its use in underground buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review on the sizing and selection of control valves for thermal hydraulics for reactor system applications

This study presents an overview regarding how to model/size, choose, and maintain control valves (CVs) for a reactor system thermal hydraulics experimentation—specifically simulating pipe break(s) and a loss of coolant accident (LOCA) analysis. In a thermal hydraulics test loop, CVs modulate fluid flow according to the control signal generated by the controller to control the process parameter. The selection of a CV in industrial applications involves many factors, including process diversity, safety, and reliability. Further, the key issues and challenges for performing proper mathematical modeling, installation, servicing, and calibration are also discussed for the benefit of operators and end-users. Additionally, this research includes case studies illustrating major plant-level accidents associated with the malfunctioning of valves. Therefore, the study will serve as a knowledge base or reference guide for young professionals and operators who wish to better understand process control applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental and Numerical Evaluation of the Thermal-Fluid Characteristics of the Helium-Cooled Modular Divertor with Multiple Jets Using a Reversed Heat Flux Approach

A single-finger unit of the Helium-Cooled Modular Divertor with Multiple Jets (HEMJ) with a plasma-facing surface (PFS) area of about 2 cm 2 has been studied in a helium (He) loop at He mass flow rates m˙ H ≤ 8 g/s and nearly prototypical conditions. Based on previous studies of the single finger of the HEMJ, our Georgia Institute of Technology group is planning to experimentally study larger divertors. Given that the HEMJ test section was heated with an induction heater and that it is impractical to scale this up to divertors with larger PFS areas, a reversed heat flux approach is being considered to measure heat transfer coefficients (HTCs). In this approach, the direction of the heat flux is reversed with water cooling and high-temperature He heating of the outer shell attached to the PFS. This work presents an initial experimental and numerical evaluation of this approach for a single HEMJ finger. Experiments with brass and copper-chromium-zirconium outer shells were conducted at dimensionless He mass flow rates or Reynolds numbers Re = 1 × 10 4 to 4.7 × 10 4 , an inlet pressure of 10 MPa, temperatures as great as 673 K, and maximum heat flux of 8.4 MW/m 2 . The experiments verify that the He-side HTCs are independent of the direction of the heat flux. Here, the results agree well with previous Nusselt number correlation and pressure loss coefficients for the HEMJ obtained using the normal heating approach.

42 ENGINEERING↗

Divertor detachment and heat exhaust mitigation control in KSTAR with tungsten divertor

KSTAR has recently undergone an upgrade to use a new tungsten divertor to run experiments in ITER-relevant scenarios. Even with a high melting point of tungsten, it is important to control the heat flux impinging on tungsten divertor targets to minimize sputtering and contamination of the core plasma. Heat flux on the divertor is often controlled by increasing the degree of detachment of scrape-off layer plasma from the target plates. In this work, we have demonstrated successful divertor detachment and heat exhaust dissipation control experiments using two different methods. The first method uses attachment fraction as a control variable which is estimated using ion saturation current measurements from embedded Langmuir probes in the divertor. The second method uses a novel machine-learning-based surrogate model of 2D UEDGE simulation database, DivControlNN. We demonstrated running inference operation of DivControlNN in realtime to estimate heat flux at the divertor and use it as the control variable in a feedback loop with impurity gas flow. We present interesting insights from these experiments including a systematic approach to tuning controllers and discuss future improvements in the control infrastructure and control variables for future burning plasma experiments.

KSTAR tungsten divertor operations↗

Production Facility Prototype Blower 1000 Hour Test Results II

Long duration tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks were not included in these tests. Five 1000 hour tests have been completed since the first test was performed in January of 2016. All five 1000 hour tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for each test, including a review of the first and second tests, are included in this report.

42 ENGINEERING↗

Production Facility Prototype Blower 1000 Hour Test Results III

Long duration operations tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks was not included in these tests. Eight long duration 500 and 1000 hour tests have been completed since the first test was performed in January of 2016. All eight long duration tests have proven successful in exposing preventable issues related to oil and helium leaks.

47 OTHER INSTRUMENTATION↗

Production Facility Prototype Blower 1000 Hour Test Results IV

Long duration operations tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks was not included in these tests. Twelve long duration 500 to 1000 hour tests have been completed since the first test was performed in January of 2016. All twelve long duration tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for the end of the ninth test to the twelfth test is included in this report. Complete details for the previous tests are shown in the reports, Production Facility Prototype Blower 1000 Hour Test Results, II, and III.

42 ENGINEERING↗

Production Facility Prototype Blower 1000 Hour Test Results V

Long duration operations tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks was not included in these tests. Thirteen long duration 500 to 1000 hour tests have been completed since the first test was performed in January of 2016. All thirteen long duration tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for the end of the thirteenth test is included in this report. Complete details for the previous tests are shown in the reports, Production Facility Prototype Blower 1000 Hour Test Results, II, III, and IV.

36 MATERIALS SCIENCE↗

Investigation of Numerical Methods for Performance Improvement of MOOSE-based System Analysis Codes

The main objective of this study is to investigate the feasibility of implementation of staggered-grid finite volume method (SG-FVM) using the MOOSE framework to support the development of the advanced system analysis code SAM. This study successfully demonstrated the integration of staggered-grid finite volume method in the application level using the MOOSE framework, although not in the framework level which should be investigated in the future. Several important properties of the implemented SG-FVM, e.g., high-order spatial accuracy and monotonicity preserving, have been demonstrated with selected numerical test cases. The superior performance in execution time was also evident based on a selected one- dimensional flow problem in a loop configuration.

97 MATHEMATICS AND COMPUTING↗

Cost Competitive Process of Battery Grade Oxides Preparation from Aged LIBS

The increasing demand for lithium-ion batteries (LIBs ) is driving development of advanced recycling and refining methods. In this project, new cathode active materials are prepared from recycled lithium battery materials and subsequently electrochemically evaluated in coin cells. In detail, scrap LIBs were mechanically processed into a metal rich black mass, then reductive acid leached into an aqueous metal solution, and finally high-purity metal hydroxide precursor materials were prepared by selective electrochemical flow precipitation. Closed-loop LIB recycling into active electrode materials will enable US manufacturers to break their reliance on foreign sources of critical materials. For example, electroextraction process used here has potential to significantly reduce chemical & water use as compared to traditional metallurgic techniques. To this end, electroextracted materials refined from used batteries were collected and processed to be tested as precursor cathode active material (pCam).During this project ,samples of high-purity recycled NMC hydroxide (~2kg each) were received from Nth Cycle. In the first received batch some impurities like cadmium, calcium, and sodium are present in quantities that would negatively impact battery performance. Nth Cycle indicated that the impurities such as cadmium are present due to poor battery separation and co-shredding of NiCd batteries with with LIB. Cadmium was not present in the two subsequent batches as Nth Cycle processed cadmium free black mass. Thus, effective recycled battery sorting is critical to closed-loop LIB recycling into active electrode materials.

99 GENERAL AND MISCELLANEOUS↗

Cost Competitive Process of Battery Grade Oxides Preparation from Aged LIBS

The increasing demand for lithium-ion batteries (LIBs) is driving development of advanced recycling and refining methods. In this project, new cathode active materials are prepared from recycled lithium battery materials and subsequently electrochemically evaluated in coin cells. In detail, scrap LIBs were mechanically processed into a metal rich black mass, then reductive acid leached into an aqueous metal solution, and finally high-purity metal hydroxide precursor materials were prepared by selective electrochemical flow precipitation. Closed-loop LIB recycling into active electrode materials will enable US manufacturers to break their reliance on foreign sources of critical materials. For example, electroextraction process used here has potential to significantly reduce chemical & water use as compared to traditional metallurgic techniques. To this end, electroextracted materials refined from used batteries were collected and processed to be tested as precursor cathode active material (pCam). During this project , samples of high-purity recycled NMC hydroxide (~2 kg each) were received from Nth Cycle. In the first received batch some impurities like cadmium, calcium, and sodium are present in quantities that would negatively impact battery performance. Nth Cycle indicated that the impurities such as cadmium are present due to poor battery separation and co-shredding of NiCd batteries with with LIB. Cadmium was not present in the two subsequent batches as Nth Cycle processed cadmium free black mass. Thus, effective recycled battery sorting is critical to closed-loop LIB recycling into active electrode materials.

25 ENERGY STORAGE↗