Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Faulting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Methane Plume Emissions Associated With Puget Sound Faults in the Cascadia Forearc

Methane gas plumes have been discovered to issue from the seafloor in the Puget Sound estuary. These gas emission sites are co-located over traces of three major fault zones that fracture the entire forearc crust of the Cascadia Subduction Zone. Multibeam and single-beam sonar data from cruises conducted in 2011, 2018, 2019, 2020 and 2021 identified the acoustic signature of over 330 bubble plumes. Dissolved gas from the plumes combines to elevate seawater methane concentrations of the entire Puget Sound estuary. Fluid samples from adjacent terrestrial hot springs and deep-water wells surrounding the estuary contain a helium-3 isotope signature, indicating a deep fluid source located near the underlying Cascadia Subduction Zone. However, Puget Sound seawater emission sites lack chemical isotope signatures and elevated thermal anomalies expected from association with a deep plate-interface reservoir. The existence of vigorous marine methane plumes located in areas of thin sediment cover and above the traces of deeply-penetrating forearc fault zones – but still presenting no thermal or chemical anomalies that are found in many other similar forearc environments and remain an unresolved paradox.

54 ENVIRONMENTAL SCIENCES↗

Fault Detection Utilizing Convolution Neural Network on Timeseries Synchrophasor Data From Phasor Measurement Units

An end-to-end supervised learning method is proposed for fault detection in the electric grid using Big Data from multiple Phasor Measurement Units (PMUs). The approach consists of preprocessing steps aimed at reducing data noise and dimensionality, followed by utilization of six classification models considered for detecting faults. Three of the models were variants of Convolutional Neural Network (CNN) architectures that consider a single type of measurement (voltage, current or frequency) at all PMUs or all types together also at all PMUs. CNN based models were compared to traditional methods of Logistic Regression (LR), Multi-layer Perceptron (MLP) and Support Vector Machine (SVM). Evaluation was conducted on two-year data measured by PMUs at 37 locations in a large electric grid. Here, the response variable for classification were extracted from the grid-wide outage event log. Experiments show that CNN-based models outperformed traditional methods on one year out-of-sample outage detection over the entire grid.

42 ENGINEERING↗

Online Detection of Inter-Turn Winding Faults in Single-Phase Distribution Transformers Using Smart Meter Data

Turn-to-turn faults between primary windings due to insulation degradation are a major cause of distribution transformer failure, and occur due to high levels of stress such as overloading and overheating. An additional consequence of these faults is an increased voltage on the transformer secondary due to effective change in turns ratio. This paper develops a novel method for early detection of insulation degradation and subsequent inter-turn winding failure by monitoring the transformer secondary voltage. The algorithm is based on a cumulative sum (CUSUM) statistic and compares voltages on neighbouring transformers to flag degrading assets. Results obtained from simulation as well as experimental data show that smart meter measurements can be utilized to achieve very high detection accuracy while keeping costs low. Here, the paper also demonstrates the validity of the algorithm in the presence of measurement noise, residential solar power injection etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Atomic faulting induced exceptional cryogenic strain hardening in gradient cell–structured alloy

Coarse-grained materials are widely accepted to display the highest strain hardening and the best tensile ductility. We experimentally report an attractive strain hardening rate throughout the deformation stage at 77 kelvin in a stable single-phase alloy with gradient dislocation cells that even surpasses its coarse-grained counterparts. Contrary to conventional understanding, the exceptional strain hardening arises from a distinctive dynamic structural refinement mechanism facilitated by the emission and motion of massive multiorientational tiny stacking faults (planar defects), which are fundamentally distinct from the traditional linear dislocation–mediated deformation. In conclusion, the dominance of atomic-scale planar deformation faulting in plastic deformation introduces a different approach for strengthening and hardening metallic materials, offering promising properties and potential applications.

Gradient dislocation structure↗

Regional-scale fault-to-structure earthquake simulations with the EQSIM framework: Workflow maturation and computational performance on GPU-accelerated exascale platforms

Continuous advancements in scientific and engineering understanding of earthquake phenomena, combined with the associated development of representative physics-based models, is providing a foundation for high-performance, fault-to-structure earthquake simulations. However, regional-scale applications of high-performance models have been challenged by the computational requirements at the resolutions required for engineering risk assessments. The EarthQuake SIMulation (EQSIM) framework, a software application development under the US Department of Energy (DOE) Exascale Computing Project, is focused on overcoming the existing computational barriers and enabling routine regional-scale simulations at resolutions relevant to a breadth of engineered systems. This multidisciplinary software development—drawing upon expertise in geophysics, engineering, applied math and computer science—is preparing the advanced computational workflow necessary to fully exploit the DOE’s exaflop computer platforms coming online in the 2023 to 2024 timeframe. Achievement of the computational performance required for high-resolution regional models containing upward of hundreds of billions to trillions of model grid points requires numerical efficiency in every phase of a regional simulation. This includes run time start-up and regional model generation, effective distribution of the computational workload across thousands of computer nodes, efficient coupling of regional geophysics and local engineering models, and application-tailored highly efficient transfer, storage, and interrogation of very large volumes of simulation data. This article summarizes the most recent advancements and refinements incorporated in the workflow design for the EQSIM integrated fault-to-structure framework, which are based on extensive numerical testing across multiple graphics processing unit (GPU)-accelerated platforms, and demonstrates the computational performance achieved on the world’s first exaflop computer platform through representative regional-scale earthquake simulations for the San Francisco Bay Area in California, USA.

58 GEOSCIENCES↗

Utah FORGE: Fault Shear Reactivation Experimental Data for Fluid Injection-Rate Controls on Seismic Moment

Included are experimental data recorded from shear experiments that specifically explore the link between fluid-injection rate and seismic moment resulting from shear reactivation of laboratory faults. Raw mechanical data from three experiments are included alongside corresponding MATLAB scripts that import and plot the data, as well as use it to calculate shear and normal stress. Experiments are performed on 2.5-3 inch long granitoid cores from the Utah FORGE EGS demonstration site, containing a single inclined fracture with small-scale roughness added to the fracture surface. The raw data included here were recorded from an aluminum triaxial pressure vessel (TEMCO) configured with three independent servo-controlled pumps, with distilled water used as the working fluid. The pumps control confining pressure, upstream pore pressure, and axial pressure, with each pump connected to a LabView interface to record applied pressures, cumulative injected water volumes, and pump flow rates. The downstream outlet from the fracture is closed to allow pressurization, which is measured by an external pressure transducer. A linear variable differential transformer (LVDT) attached to the axial piston measures axial displacement, from which we calculate shear displacement along the fracture. Additionally, P-wave transducers are used to record acoustic signatures, where acoustic emission events and maximum amplitudes are compared against seismic moment and shear slip velocity. Fluid injection rates range between 0.05 mL/min, 0.25 mL/min, and 0.75 mL/min for each experiment. Along-fault pressure distributions are progressively less uniform as injection rates increase, representing a switch from steady-state to transient conditions. Triggered shear displacement is used as a proxy for seismic moment and is indexed against cumulative injection volume and rate. Each experiment is performed under constant shear stress conditions, and the sample is fully saturated with DI water. Axial and confining stresses are applied to 3 MPa through pressure-stepping in 500 kPa increments. The pore pressure is held constant at 200 kPa prior to initiating the experiment, and initial axial displacement is recorded. The axial stress is then increased to initiate shear mobilization during the loading phase (run-in) until a peak steady state is achieved. The initial shear stress is reduced to approximately 80% of the peak shear stress by decreasing the axial stress, then held constant for the duration of each experiment.

15 GEOTHERMAL ENERGY↗

Report on High Energy Arcing Fault Experiments

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for medium voltage electrical switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers four of the fourteen planned medium voltage electrical enclosure experiments. Subsequent reports will document the additional experiments performed in the future. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the United States Nuclear Regulatory Commission (NRC), the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setups and execution. The HEAF experiments were performed on four near-identical units of General Electric metal-clad medium voltage switchgear. The three-phase arcing fault was initiated on the primary cable connection bus. All four experiments used the same system voltage (6.9 kV) but varied the current and duration. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers and slug calorimeters at various locations around the electrical enclosures. Internal enclosure pressures were measured during the experiments. The experiments were documented with normal and high-speed videography, infrared imaging, and photography. Insights from the experimental series included timing information related to enclosure breach, event progression, mass loss measurements for electrodes and steel enclosures, peak pressure rise, particle analysis, along with visual and thermal imaging data to better understand and characterize the hazard. These results will be used in subsequent efforts to advance the state of knowledge related to HEAF.

42 ENGINEERING↗

A Hot‐Swappable, Fault‐Tolerant, Modular Power Converter System for Solar Photovoltaic Plants

The performance metrics of the state-of-the-art commercial solar inverters, such as system cost, operation and maintenance (O&M) cost, service life, reliability, maintainability, and power density are much lower than the target metrics needed to achieve SunShot’s 2030 levelized cost of energy (LCOE) goals. To overcome the shortcomings of the existing solar inverters, this project proposed a novel Hot-Swappable, Fault-Tolerant, Modular Power Converter (HSFT-MPC) concept for solar photovoltaic (PV) plants and proved the concept through the design, fabrication, and laboratory test validation of a single-phase HSFT-MPC prototype. The HSFT-MPC has the following distinct advantages over the state-of-the-art: 1) elimination of harmonic/ electromagnetic interference (EMI) filter in the inverter stage due to the novel topology, 2) lower system cost and higher power density due to the modular design, elimination of harmonic/EMI filter, and lower cooling requirement, 3) higher efficiency due to lower switching frequencies, 4) higher reliability and longer (50 years) service life due to simpler cooling and fault tolerance capability, 5) easier installation, lower O&M cost, and improved maintainability due to the modular design and hot-swappable power electronic building blocks (PEBBs), and 6) improved manufacturability due to the modular design. This project developed a single-phase HSFT-MPC prototype with 25kW nominal output power, 2.4kV, 60Hz nominal AC output, lower than 5% AC output voltage total harmonic distortion, over 5 kW/L inverter power density, and 99.4% inverter peak efficiency, being tolerant to failure of single and multiple PEBBs, and capable of hot swapping of the failed PEBB(s). The HSFT-MPC enables uninterruptable operation of the solar PV plant when failure of single or multiple PEBBs or PV modules occurs. Compared with the existing solar inverters in the market, the HSFT-MPC is expected to reduce the inverter failure-caused downtime and energy losses of solar PV plants by more than 60% and 50%, respectively. Project findings have been presented at major conferences in the field and published in peer-reviewed papers, which added new knowledge to the field of power electronics for solar PV systems. A minicourse on Solar PV Systems was developed for outreach activities. The minicourse will help attract young individuals to the renewable energy profession which has a significant talent shortage. The HSFT-MPC is expected to overcome all of the shortcomings of the state-of-the-art solar inverters in terms of cost, efficiency, service life, reliability, maintainability, and manufacturability targets needed to achieve SunShot’s 2030 LCOE goals. Therefore, the proposed HSFT-MPC concept has the great potential to disrupt the current solar inverter market. This project created a pathway towards industry adoption of the HSFT-MPC to help achieve 50-year service life solar PV systems. Since the solar PV plants using the HSFT-MPC will feature with higher reliability, longer service life, and easier maintenance, they are particularly useful for the rural areas with underserved populations that demand reliable and affordable clean electricity. The outcomes of the project have the strong potential to address national needs in the field of renewable energy to reduce CO 2 emissions from the electricity sector, reduce imports of energy from foreign sources, and improve energy security, efficiency, and sustainability. Since electricity is used in almost all of society’s sectors, the outcomes of the project will benefit various sectors of society and economy.

14 SOLAR ENERGY↗

Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable the bulk integration of renewable resources into the future power grid; however, the performance of GFM inverters during unbalanced faults remains underexplored. This paper proposes a novel current-limiting method for GFM inverters to handle unbalanced fault conditions while providing voltage support to the main grid. The proposed current limiter combines concepts of dynamic virtual-impedance and current-reference saturation limiting, all built in the stationary reference frame, to achieve improved current-limiting performance under unbalanced load/fault conditions. System-wide full-order transient simulations with multiple GFM inverters demonstrate the potential of the method and benchmark the performance against state-of-the-art current limiters. Simulation results portray improved voltage balancing performance of the proposed method compared to both current-reference saturation and virtual-impedance limiting.

controller anti windup↗

Connecting Risk and Resilience for a Power System Using the Portland Hills Fault Case Study

Active seismic faults in the Pacific Northwest area have encouraged electric utilities in the region to deeply contemplate and proactively intervene to support grid resilience. To further this effort this research introduces Monte Carlo (MC)-based power system modeling as a means to inform the Performance Based Earthquake Engineering method and simulates 100,000 sample earthquakes of a 6.8 magnitude (M6.8) Portland Hills Fault (PHF) scenario in the Portland General Electric (PGE) service territory as a proof of concept. This paper also proposes the resilience metric Seismic Load Recovery Factor (SLRF) to quantify the recovery of a downed power system and thus can be used to quantify earthquake economic risk. Using MC results, the SLRF was evaluated to be 19.7 h and the expected economic consequence cost of a M6.8 PHF event was found to be $\$180$ million with an annualized risk of $\$90,000$ given the event’s 1 in 2000 year probability of occurrence. The MC results also identified the eight most consequential substations in the PGE system—i.e., those that contributed to maximum load loss. This paper concludes that retrofitting these substations reduced the expected consequence cost of a M6.8 PHF event to $117 million.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stacking Faults Originating from Star-Defects in 4H-SiC

Intense efforts are currently in progress to study various sources of basal plane dislocations (BPDs) in SiC epitaxial layers. BPDs can generate Shockley-type stacking faults (SSFs) in SiC epitaxial layers, which have been shown to be associated with the degradation of power devices. This study shows that the star-shaped defect can be a source of several BPDs in the epitaxial layer. We investigate the complex microstructure of the star defect, the generation of BPDs, and expansion of SSFs using various complementary microscopy and optical techniques. We show direct evidence that star-defects can be a nucleation point of single-SSFs that can expand at the core of the defect. Newly found secondary dislocation arrays extending over a few centimeters away are found to be emanating from the primary arms of the star defect. The presence of such dislocation walls and the expansion of single-SSFs will affect the yield of numerous die on a wafer. Further understanding of the formation mechanism of stacking faults generated from star-defects as provided in this study helps understand their effect on SiC-based devices, which is crucial to assess device reliability.

36 MATERIALS SCIENCE↗

A dataset of cyber-induced mechanical faults on buildings with network and buildings data

We have collected data of cyber-induced mechanical faults on buildings using a simulation platform. A DOE reference building model was used for running the simulation under a Rogue device attack and collected the network data as well as the physical buildings data to better understand the impacts of cyber attacks on the building and help identify the source of the mechanical fault with the network data. Alfalfa is the tool used for simulating the DOE reference buildings and acts as an interface to the model for querying the status and providing input externally. The Building Automation System (BAS) is the centralized controller providing control commands to other BACnet devices on the network based on the building status received from Alfalfa. The BACnet devices like damper will listen for the control commands from BAS on the BACnet network and implement it. The attacker is the malicious actor on the network creating disruptions by placing cyber-attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification: Preprint

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system monitoring↗

Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults: Preprint

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable bulk integration of renewable sources into the future power grid. However, the performance of GFM inverters during unbalanced faults remains under-explored. In this paper, a novel current-limiting method is proposed for GFM inverters to handle unbalanced fault conditions while providing voltage support to the main grid. The proposed current limiter combines concepts of dynamic virtual-impedance and current-reference saturation limiting, all built-up in the stationary reference frame to achieve improved current-limiting performance under unbalanced load/fault conditions. System-wide full-order transient simulations with multiple GFM inverters demonstrate the potential of the method and benchmark the performance against state-of-the-art current limiters. Simulation results portray improved voltage balancing performance of the proposed method compared to both current-reference saturation and virtual-impedance limiting.

controller anti windup↗

Multi-module-based CVAE to predict HVCM faults in the SNS accelerator

We present a multi-module framework based on Conditional Variational Autoencoder (CVAE) to detect anomalies in the power signals coming from multiple High Voltage Converter Modulators (HVCMs). We condition the model with the specific modulator type to capture different representations of the $\mathcal{normal}$ waveforms and to improve the sensitivity of the model to identify a specific type of fault when we have limited samples for a given module type. We studied several Artificial Neural Network (ANN) architectures for our CVAE model and evaluated the model performance by looking at their loss landscape for stability and generalization. Our results for the Spallation Neutron Source (SNS) experimental data show that the trained model generalizes well to detecting multiple fault types for several HVCM module types. The results of this study can be used to improve the HVCM reliability and overall SNS uptime.

43 PARTICLE ACCELERATORS↗

Shock-induced phase transitions and stacking fault formation in additively manufactured eutectic high-entropy alloy Ni 40 Co 20 Fe 10 Cr 10 Al 18 W 2

Ni 40 Co 20 Fe 10 Cr 10 Al 18 W 2 additively manufactured using laser powder bed fusion (LPBF) is among the toughest as-built alloys reported and is a promising candidate for use in extreme environments. However, its behavior under multi-megabar pressure regimes remains unexplored. We used femtosecond in situ X-ray diffraction to investigate the shock response of LPBF Ni40Co20Fe10Cr10Al18W2 under laser-driven shock compression and release. Our results reveal that the initial dual-phase face-centered + body-centered structure transforms to a single face-centered phase over a wide pressure range of 84±10 to 277±55 GPa, followed by a transition to a single body-centered phase at 431±48 GPa. We establish the Hugoniot equation-of-state of LPBF Ni 40 Co 20 Fe 10 Cr 10 Al 18 W 2 and compare it to the benchmark alloy AlCoCrFeNi 2.1 , demonstrating the effects of W-doping and increased Al content. High stacking fault probabilities, close to those measured in Au and Ag, are observed upon compression. A portion of the stacking faults are annihilated upon release to ambient pressure.

36 MATERIALS SCIENCE↗

Atomic-Scale Observation of O1 Faulted Phase-Induced Deactivation of LiNiO 2 at High Voltage

LiNiO 2 and cobalt-free ultrahigh-Ni content cathodes suffer from rapid capacity loss and severe chemomechanical degradation, especially when operated at high voltages. Here, by cycling LiNiO 2 up to 4.7 V, we report the atomic-scale observation of O1 faulted phase-induced deactivation of LiNiO 2 . We found that although a thin layer of O3 phase forms on the particle surface by reversible O3 → O1 transformation during discharge, the bulk interior still maintains the O1 faulted phase, leading to rapid capacity loss of LiNiO 2 . Moreover, the atomic configuration of the O1/O3 interface is investigated comprehensively. We found that the misfit along the c axes of the O1 and O3 phases results in the formation of misfit dislocations, whereby cation mixing is promoted at dislocation cores. Further, a transition zone with continuous shear along the a-b plane is uncovered between the O1 and O3 phases for the first time. Besides, severe oxygen loss-induced pore formation and concurrent rock salt transformation are also identified.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Predicting Future Laboratory Fault Friction Through Deep Learning Transformer Models

Machine learning models using seismic emissions as input can predict instantaneous fault characteristics such as displacement and friction in laboratory experiments, and slow slip in Earth. Here, we address whether the seismic/acoustic emission (AE) from laboratory experiments contains information about future frictional behavior. The approach uses a convolutional encoder-decoder containing a transformer model in the latent space, similar to models used for natural language processing. We test the model limits using progressively larger AE input time windows and progressively larger output friction time windows. The results demonstrate that very near-term friction predictions are indeed contained in the AE signal, and predictions are progressively worse farther into the future. The future predictions by the model of impending failure in the near-term are remarkably robust. This first effort predicting future fault frictional behavior with machine learning will aid in guiding efforts for applications in Earth.

58 GEOSCIENCES↗