Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREQUENCY STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

The SA-2239/WLQ-4(V) Cutty Sark distribution system

A redundant frequency and time distribution system provides a multiplicity of isolated outputs, all of which are derived from three atomic frequency standards. The distribution system monitors input parameters of the signals coming from the Cesium Standards and selects one to be the primary standard, phase locks an internal oscillator which has excellent aging characteristics in the open loop mode and acts as a filter to provide phase noise improvement, and generates 1 megahertz and 100 kHz by direct synthesis. Additionally, the system distributes RF and timing signals consisting of 5 MHz, 1 MHz, 100 kHz, BCD Time-of-Day, 1 pps and 1 ppm.

Vulcan, A.↗

The impact of WARC-79 on space applications

It is pointed out that the decisions of WARC-79 are crucial to the future utility of applications evolving from research and development of space techniques. WARC-79 provided the spectrum allocations and protection which will permit continued development of a broad range of space applications. Space research and earth-exploration satellite services are discussed, taking into account remote sensing, spectrum requirements, implications for designers and regulators, and space research and earth exploration satellite services. Meteorological satellites are considered along with search-and-rescue operations, standard frequency and time satellites, the search for extraterrestrial intelligence, and the solar-power satellite. The WARC rejected a U.S. allocation proposal for the solar-power satellite on the basis that the proposal was premature because spectrum, biological, and ecological impacts have not yet been fully examined.

Kiebler, J. W.↗

A rubidium clock for GPS

The design objectives and approach; the more important design features; the signal parameters and error budget; and early test results in the development of a second-source rubidium frequency standard for use in the GPS navigation satellites are discussed. Tests of a breadboard version of the RFS show that the measured time-domain stability is within the goal specification. The results are uncorrected for the conribution of the reference and are probably limited by the reference stability in the medium term region. The Rb reference is bbetter in the medium term region, but the Cs reference is etter at 10,000 seconds and longer, probably because of the barometric sensitivity of the rubidium reference unit.

Riley, W. J.↗

Satellite time and frequency transfer (STIFT)

The concept of placing a hydrogen maser high stability clock in Earth orbit to provide accurate time and frequency comparisons worldwide to major timing centers and to a large number of radio observatory antenna sites involved in VLBI measurements was studied. The proposal was chiefly directed toward studies and initial hardware designs for time comparisons between hydrogen maser frequency standards and to modifications of the hydrogen maser for long-term use in space.

Vessot, R. F. C.↗

Phase Calibration for the Block 1 VLBI System

Very Long Baseline Interferometry (VLBI) in the DSN provides support for spacecraft navigation, Earth orientation measurements, and synchronization of network time and frequency standards. An improved method for calibrating instrumental phase shifts has recently been implemented as a computer program in the Block 1 system. The new calibration program, called PRECAL, performs calibrations over intervals as small as 0.4 seconds and greatly reduces the amount of computer processing required to perform phase calibration.

Roth, M. G.↗

One nanosecond time synchronization using series and GPS

Subnanosecond time sychronization between two remote rubidium frequency standards is verified by a traveling clock comparison. Using a novel, code ignorant Global Positioning System (GPS) receiver developed at JPL, the SERIES geodetic baseline measurement system is applied to establish the offset between the 1 Hz. outputs of the remote standards. Results of the two intercomparison experiments to date are presented as well as experimental details.

Buennagel, A. A.↗

Accurate frequency and intensity measurements of the infrared spectra of atmospheric molecules

Various problems encountered and solutions found in infrared laboratory measurements on atmospheric molecules are discussed. The advantages and limitations of various measurement techniques and equipment are discussed, with emphasis placed on calibration techniques and measurement accuracy and precision. Frequency calibration aids are presented, including the current and planned tables of absorption frequency standards being developed by the Bureau of Standards for the calibration of high-resolution devices with an accuracy of + or - 3 MHz. It is noted that intensity measurements are highly susceptible to systematic errors and that great care must be taken to obtain accuracies better than + or - 10%. What is even more difficult is knowing the accuracy of a particular measurement. Recent work done on providing accurate intensity data are described.

Maki, A. G.↗

Tuning Concept for Resonant Cavities

Deviations from resonance detected by sampling phases. Automatic tuner feedback control system derives error signal from E and H plane probe signals. Control objective to maintain phase difference between E and H at 90 degrees. Technique estimated to sensitive to fractional frequency deviation of about 5 X 10-16 and applicable not only to masers but also other microwave elements, including klystrons, general purpose oscillators, and frequency standards.

Sydnor, R. L.↗

Precise spacecraft tracking using VLBI digital tone extraction for the purpose of gravitational wave detection

The prospect for the detection of a cosmic background of gravitational wave radiation is discussed. Experiments utilizing precise Doppler tracking of interplanetary spacecraft for the purpose of detecting this background are reviewed. Results of a recent experiment are presented which used facilities of NASA's Deep Space Tracking Network and Owens Valley Radio Observatory to track the Voyager spacecraft in an ultra precise manner using two independent hydrogen masers as frequency standards. The present limiting sensitivity of these experiments are believed to be tropospheric and plasma variations affecting the X band microwave signals at periods of between 1,000 - 10,000 seconds duration.

Anderson, A. J.↗

Satellite Time- and Frequency-Transfer System

Time synchronized at distant points within nanosecond. Report describes satellite-borne time-and frequency-transfer system proposed for synchronization of clocks at stations around Earth. Orbiting hydrogen-maser clock and frequency standard communicate by microwave links with Earth stations using hydrogen masers as local clocks. Pulsed-laser time-transfer sub-system also operated concurrently, either synchronized or unsynchronized with microwave subsystems.

Vessot, R. F. C.↗

Methods to recover the narrow Dicke sub-Doppler feature in evacuated wall-coated cells without restrictions on cell size

The hyperfine resonance observed in evacuated wall-coated cells with dimensions lambda/2 (lambda is the hyperfine resonance wavelength) consists of a narrow Dicke sub-Doppler linewidth feature, the spike, superimposed on a broad pedestal. The hydrogen maser provides a classic example of this lineshape. As cell size is increased, an effect unique to evacuated wall-coated cells occurs. Certain combinations of microwave field distribution and cell size result in a lineshape having a pedestal with a small spike feature or only the broad pedestal with no spike. Such conditions are not appropriate for atomic frequency standard applications. The cause of the evacuated wall-coated cell lineshape is reviewed and methods to recover the narrow spike feature without restrictions on cell size is discussed. One example is a cell with dimensions having equal volumes of exposure to opposite phases of the microwave magnetic field.

Robinson, H. G.↗

Development of hydrogen masers for K-3 VLBI system

Two field operable hydrogen masers were developed for the VLBI joint experiment conducted by the cooperation between RRL and NASA. They are now playing an important role as the time and frequency standard of the K-3 VLBI system, which has also been developed by RRL.

Morikawa, T.↗

The seasonal variation of the D region as inferred from propagation characteristics of LF radio waves

The propagation data of JG2AS 40 kHz (Japanese Standard Frequency), Loran C 100 kHz radio waves, and meteorological data were analyzed to study the association of propagation characteristics of LF radio waves with the atmospheric circulation in the mesosphere. The monthly averaged electric fields were depicted on the complex plane for typical summer and winter months, June and November. The locus traced out by the electric field vector during daytime is nearly circular. This is because during daytime the amplitude of the sky wave remains nearly constant while its phase changes in accord with the height change of the reflection layer, and thus the electric field vector traces out a circular locus with its center at the tip of the supposed ground wave vector. The locus has a loop during the sunrise or sunset period, which seems to arise from interference of two waves reflected by two different layers. In June the amplitude of the sky wave decreases rapidly before the dawn or increases after the dusk. In November such rapid change is not observed. During nighttime, the sky wave phase changes in such a way as to suggest that the reflection height moves upwards with time before midnight or lowers after midnight in November. In June it changes similarly before midnight, but after midnight it varies erratically. These characteristics are closely related to the structure of the D region, which is clearly shown by simulating the loci traced out by electric fields.

Ishimine, T.↗

Estimation of neutral wind velocity in the ionospheric heights by HF-Doppler technique

Three net stations located about 100 kilometers apart were set up around the station of the standard frequency and time signals (JJY) in central Japan and measurements of atmospheric gravity waves in the ionospheric heights (F-region, 200 to 400 km) were made by means of the HF-Doppler technique during the period of February 1983 to December 1983. The frequencies of the signals received are 5.0, 8.0 and 10.0 MHz, but only the 8.0 MHz signals are used for the present study, because no ambiguities due to the interference among other stations such as BPM, BSF, etc. exist by the use of 8.0 MHz. Two main results concerning the horizontal phase velocity of the atmospheric gravity waves with periods of 40 to 70 min may be summarized as follows: (1) the value of the phase velocity ranges from 50 m/s to 300 m/s; (2) the direction of the gravity wave propagation shows a definite seasonal variation. The prevailing direction of the gravity waves in winter is from north to south, which is consistent with the results obtained from other investigations. On the other hand, the two directions, from northeast to southwest and from southeast to northeast, dominate in summer.

Kitamura, T.↗

Cost characteristics of tilt-rotor, conventional air and high speed rail short-haul intercity passenger service

The cost analysis done to support an assessment of the potential for a small tilt-rotor aircraft to operate in short-haul intercity passenger service is described in detail. Anticipated costs of tilt-rotor air service were compared to the costs of two alternatives: conventional air and high speed rail (HSR). Costs were developed for corridor service, varying key market characteristics including distance, passenger volumes, and minimum frequency standards. The resulting cost vs output information can then be used to compare modal costs for essentially identical service quality and passenger volume or for different service levels and volumes for each mode, as appropriate. Extensive sensitivity analyses are performed. The cost-output features of these technologies are compared. Tilt-rotor is very attractive compared to HSR in terms of costs over the entire range of volume. It also has costs not dramatically different from conventional air, but tilt-rotor costs are generally higher. Thus some of its other advantages, such as the VTOL capability, must offset the cost disadvantage for it to be a preferred or competitive mode in any given market. These issues are addressed in the companion report which considers strategies for tilt-rotor development in commercial air service.

Schoendorfer, David L.↗