Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Tissue factor pathway inhibitor prevents airway obstruction, respiratory failure and death due to sulfur mustard analog inhalation

Sulfur mustard (SM) inhalation causes airway injury, with enhanced vascular permeability, coagulation, and airway obstruction. The objective of this study was to determine whether recombinant tissue factor pathway inhibitor (TFPI) could inhibit this pathogenic sequence. Methods: Rats were exposed to the SM analog 2-chloroethyl ethyl sulfide (CEES) via nose-only aerosol inhalation. One hour later, TFPI (1.5 mg/kg) in vehicle, or vehicle alone, was instilled into the trachea. Arterial O{sub 2} saturation was monitored using pulse oximetry. Twelve hours after exposure, animals were euthanized and bronchoalveolar lavage fluid (BALF) and plasma were analyzed for prothrombin, thrombin–antithrombin complex (TAT), active plasminogen activator inhibitor-1 (PAI-1) levels, and fluid fibrinolytic capacity. Lung steady-state PAI-1 mRNA was measured by RT-PCR analysis. Airway-capillary leak was estimated by BALF protein and IgM, and by pleural fluid measurement. In additional animals, airway cast formation was assessed by microdissection and immunohistochemical detection of airway fibrin. Results: Airway obstruction in the form of fibrin-containing casts was evident in central conducting airways of rats receiving CEES. TFPI decreased cast formation, and limited severe hypoxemia. Findings of reduced prothrombin consumption, and lower TAT complexes in BALF, demonstrated that TFPI acted to limit thrombin activation in airways. TFPI, however, did not appreciably affect CEES-induced airway protein leak, PAI-1 mRNA induction, or inhibition of the fibrinolytic activity present in airway surface liquid. Conclusions: Intratracheal administration of TFPI limits airway obstruction, improves gas exchange, and prevents mortality in rats with sulfur mustard-analog-induced acute lung injury. - Highlights: • TFPI administration to rats after mustard inhalation reduces airway cast formation. • Inhibition of thrombin activation is the likely mechanism for limiting casts. • Rats given TFPI had improved tissue oxygenation, and mortality was prevented.

60 APPLIED LIFE SCIENCES↗

Functional performance of pyrovalves

Following several flight and ground test failures of spacecraft systems using single-shot, 'normally closed' pyrotechnically actuated valves (pyrovalves), a Government/Industry cooperative program was initiated to assess the functional performance of five qualified designs. The goal of the program was to provide information on functional performance of pyrovalves to allow users the opportunity to improve procurement requirements. Specific objectives included the demonstration of performance test methods, the seating; these gases/particles entered the fluid path of measurement of 'blowby' (the passage of gases from the pyrotechnic energy source around the activating piston into the valve's fluid path), and the quantification of functional margins for each design. Experiments were conducted at NASA's Langley Research Center on several units for each of the five valve designs. The test methods used for this program measured the forces and energies required to actuate the valves, as well as the energies and the pressures (where possible) delivered by the pyrotechnic sources. Functional performance ranged widely among the designs. Blowby cannot be prevented by o-ring seals; metal-to-metal seals were effective. Functional margin was determined by dividing the energy delivered by the pyrotechnic sources in excess to that required to accomplish the function by the energy required for that function. Two of the five designs had inadequate functional margins with the pyrotechnic cartridges evaluated.

Bement, Laurence J.↗

Petrophysical properties of saprolites from the Oak Ridge Integrated Field Research Challenge site, Tennessee

At the Oak Ridge Integrated Field Research Challenge site, near Oak Ridge, Tennessee, the shallow saprolitic aquifer is contaminated by nitric acid, uranium, and metals originating from the former S3 settling ponds. To interpret low-frequency geophysical methods used to image contaminant plumes, we have characterized the petrophysical properties of three representative saprolite core samples. Their hydraulic conductivity ranges from to in agreement with field data. Complex conductivity measurements, in the frequency range of 1 mHz to 45 kHz, were performed with NaCl solutions with electrical conductivities in the range to , a range representative of field conditions. The electrical conductivity data were well reproduced with a simple linear conductivity model between the saprolite conductivity and the pore water conductivity. The conductivity plots were used to estimate the formation factor (the cementation exponent was about ) and the surface conductivity ( ). The magnitude of the surface conductivity depended on the degree of weathering and therefore on the amount of smectite and mixed layer (illite-smectite) clays present in the saprolite. The chargeability of the core samples was in the range of and is strongly dependent on the salinity. We also performed streaming potential measurements with the same pore fluid composition as that used for the complex conductivity measurements. We found an excess of movable electrical charges on the order of 100 to in agreement with previous investigations connecting the movable excess charge density to permeability. The zeta potential was in the range of to independent on the salinity. The electrical measurements were consistent with an average cation exchange capacity in the range of 1.4 to and a specific surface area on the order of 4000 to about 30,000 . Read More: http://library.seg.org/doi/abs/10.1190/geo2012-0176.1

Revil, André↗

PIV Investigations of the Flow Field in the Volute of a Rotary Blood Pump

A full-size acrylic model of a rotary blood pump was developed in order to utilize Particle Image Velocimetry (PIV) to make measurements of the fluid velocities and turbulent stresses throughout the device. The development of an understanding of the hemodynamics within the blood pump is critical to the development and validation of computational models. A blood analog solution, consisting of sodium iodide solution and glycerin, was developed to match physiological kinematic viscosity. The refractive indecies of the fluid, the pump casing and the impeller were matched to facilitate the use of PIV to make velocity measurements. Velocity measurements made in the volute exit/diffuser region are presented for pumps speeds of 3000-3850 rpm. At each speed data were obtained at a physiological pressure of 90 mmHg and at a maximum flow condition. Four hundred data pairs were used for each resultant mean velocity vector value, representing greater than an order of magnitude more data pairs than reported previously in the literature on similar devices and resulting in velocity uncertainty levels of approximately 2.9%.

Sankovic, John M.↗

PIV Investigations of the Flow Field in the Volute of a Rotary Blood Pump

A full-size acrylic model of a rotary blood pump was developed in order to utilize Particle Image Velocimetry (PIV) to make measurements of the fluid velocities and turbulent stresses throughout the device. The development of an understanding of the hemodynamics within the blood pump is critical to the development and validation of computational models. A blood analog solution, consisting of sodium iodide solution and glycerin, was developed to match physiological kinematic viscosity. The refractive indices of the fluid, the pump casing, and the impeller were matched to facilitate the use of PIV to make velocity measurements. Velocity measurements made in the volute exit/diffuser region are presented for pumps speeds of 3000-3850 rpm. At each speed data were obtained at a physiological pressure of 12 kPa and at a maximum flow condition. Four hundred data pairs were used for each resultant mean velocity vector value, representing greater than an order of magnitude more data pairs than reported previously in the literature on similar devices and resulting in velocity uncertainty levels of approximately 22.9%.

Sankovic, John M.↗

Fluid Shifts

INTRODUCTION: Mechanisms responsible for the ocular structural and functional changes that characterize the visual impairment and intracranial pressure (ICP) syndrome (VIIP) are unclear, but hypothesized to be secondary to the cephalad fluid shift experienced in spaceflight. This study will relate the fluid distribution and compartmentalization associated with long-duration spaceflight with VIIP symptoms. We also seek to determine whether the magnitude of fluid shifts during spaceflight, as well as the VIIP-related effects of those shifts, can be predicted preflight with acute hemodynamic manipulations, and also if lower body negative pressure (LBNP) can reverse the VIIP effects. METHODS: Physiologic variables will be examined pre-, in- and post-flight in 10 International Space Station crewmembers including: fluid compartmentalization (D2O and NaBr dilution); interstitial tissue thickness (ultrasound); vascular dimensions and dynamics (ultrasound and MRI (including cerebrospinal fluid pulsatility)); ocular measures (optical coherence tomography, intraocular pressure, ultrasound); and ICP measures (tympanic membrane displacement, otoacoustic emissions). Pre- and post-flight measures will be assessed while upright, supine and during 15 deg head-down tilt (HDT). In-flight measures will occur early and late during 6 or 12 month missions. LBNP will be evaluated as a countermeasure during HDT and during spaceflight. RESULTS: The first two crewmembers are in the preflight testing phase. Preliminary results characterize the acute fluid shifts experienced from upright, to supine and HDT postures (increased stroke volume, jugular dimensions and measures of ICP) which are reversed with 25 millimeters Hg LBNP. DISCUSSION: Initial results indicate that acute cephalad fluid shifts may be related to VIIP symptoms, but also may be reversible by LBNP. The effect of a chronic fluid shift has yet to be evaluated. Learning Objectives: Current spaceflight VIIP research is described, including novel hardware and countermeasures.

Stenger, M. B.↗

Opto-mechano-fluidic viscometer

The recent development of opto-mechano-fluidic resonators has provided—by harnessing photon radiation pressure—a microfluidics platform for the optical sensing of fluid density and bulk modulus. Here, we show that fluid viscosity can also be determined through optomechanical measurement of the vibrational noise spectrum of the resonator mechanical modes. A linear relationship between the spectral linewidth and root-viscosity is predicted and experimentally verified in the low viscosity regime. Our result is a step towards multi-frequency measurement of viscoelasticity of arbitrary fluids, without sample contamination, using highly sensitive optomechanics techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Containers and systems for the measurement of radioactive gases and related methods

Containers for a fluid sample containing a radionuclide for measurement of radiation from the radionuclide include an outer shell having one or more ports between an interior and an exterior of the outer shell, and an inner shell secured to the outer shell. The inner shell includes a detector receptacle sized for at least partial insertion into the outer shell. The inner shell and outer shell together at least partially define a fluid sample space. The outer shell and inner shell are configured for maintaining an operating pressure within the fluid sample space of at least about 1000 psi. Systems for measuring radioactivity in a fluid include such a container and a radiation detector received at least partially within the detector receptacle. Methods of measuring radioactivity in a fluid sample include maintaining a pressure of a fluid sample within a Marinelli-type container at least at about 1000 psi.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Measurement Sensor of the Boundary Shear Stress in Fluid Flow

The flow fields and boundary erosion that are associated with scour at bridge piers are very complex. Direct measurement of the boundary shear stress and boundary pressure fluctuations in experimental scour research has always been a challenge and high spatial resolution and fidelity have been almost impossible. Most researchers have applied an indirect process to determine shear stress using precise measured velocity profiles. Laser Doppler Anemometry and Particle Image Velocimetry are common techniques used to accurately measure velocity profiles. These methods are based on theoretical assumptions to estimate boundary shear stress. In addition, available turbulence models cannot very well account for the effect of bed roughness which is fundamentally important for any CFD simulation. The authors have taken on the challenge to advance the magnitude level to which direct measurements of the shear stress in water flow can be performed. This paper covered the challenges and the efforts to develop a higher accuracy and small spatial resolution sensor. Also, preliminary sensor designs and test results are presented.

Badescu, Mircea↗

Predictive models for moving contact line flows

Modeling flows with moving contact lines poses the formidable challenge that the usual assumptions of Newtonian fluid and no-slip condition give rise to a well-known singularity. This singularity prevents one from satisfying the contact angle condition to compute the shape of the fluid-fluid interface, a crucial calculation without which design parameters such as the pressure drop needed to move an immiscible 2-fluid system through a solid matrix cannot be evaluated. Some progress has been made for low Capillary number spreading flows. Combining experimental measurements of fluid-fluid interfaces very near the moving contact line with an analytical expression for the interface shape, we can determine a parameter that forms a boundary condition for the macroscopic interface shape when Ca much les than l. This parameter, which plays the role of an "apparent" or macroscopic dynamic contact angle, is shown by the theory to depend on the system geometry through the macroscopic length scale. This theoretically established dependence on geometry allows this parameter to be "transferable" from the geometry of the measurement to any other geometry involving the same material system. Unfortunately this prediction of the theory cannot be tested on Earth.

Rame, Enrique↗

Microparticle analysis system and method

A device for analyzing microparticles is provided which includes a chamber with an inlet and an outlet for respectively introducing and dispensing a flowing fluid comprising microparticles, a light source for providing light through the chamber and a photometer for measuring the intensity of light transmitted through individual microparticles. The device further includes an imaging system for acquiring images of the fluid. In some cases, the device may be configured to identify and determine a quantity of the microparticles within the fluid. Consequently, a method for identifying and tracking microparticles in motion is contemplated herein. The method involves flowing a fluid comprising microparticles in laminar motion through a chamber, transmitting light through the fluid, measuring the intensities of the light transmitted through the microparticles, imaging the fluid a plurality of times and comparing at least some of the intensities of light between different images of the fluid.

Morrison, Dennis R.↗

Fluid mass sensor for a zero gravity environment

A sensor for measuring the mass of fluids, is described which includes a housing having an inlet and outlet for receiving and dumping the fluid, a rotary impeller within the housing for imparting centrifugal motion to the fluid and a pressure sensitive transducer attached to the housing to sense the rotating fluid pressure. The fluid may be drawn into the housing by entrainment within a gas stream. The resulting mixture is then separated into two phases: gas and liquid. The gas is removed from the housing and the pressure of the liquid, under centrifugal motion, is sensed and correlated with the mass of the fluid.

Fogal, G. L.↗

CARS measurements of temperature and species number density in supersonic combusting flow

A supersonic combustion burner has been probed by coherent anti-Stokes Raman Spectroscopy and the results compared with computational fluid dynamics. Simultaneous measurement of temperature, nitrogen number density and oxygen number density have been acquired throughout the external combustion region. Preliminary calculations have been made on this system to estimate the burner performance. Comparisons of these techniques are included.

Antcliff, Richard R.↗

Tissue fluid shift, forelimb loading, and tail tension in tail-suspended rats

The tail suspension model (head-down tilt) simulates hypogravity in terms of musculoskeletal loss in the rat. However, little is known of tissue fluid shifts and body weight distribution in this model. Tissue fluid pressures were measured by wick catheters in 12 Munich-Wistar rats before, during, and after 48 hrs of tail suspension (about 30 deg head-down tilt). Subcutaneous tissue fluid pressure in the neck increased from -2.2 + or - 0.4 (normal horizontal position) to +4.0 + or - 1.5 cm H2O during tail suspension, indicating a cephalic fluid shift and significant edema during head-down tilt. In a separate study, six rats were suspended at 30-70 deg, and forelimb load and tail tension were measured by a balance and force transducer, respectively. Approximately 50 percent of body weight (BW) was loaded on forelimbs at a head-down tilt angle of 30 deg and forelimb load declined linearly to 10 percent BW at 70 deg. Furthermore, tail tension increased from 50 percent BW at 30 deg to 85 percent BW at 70 deg. These results indicate that less than normal loads are applied to forelimbs of rats suspended at angles of less than 30 deg and that the tail bears an increasing proportion of the rat's body weight at head-down tilt angles of less than 30 deg.

Hargens, A. R.↗

A Broadband Laboratory Study of the Seismic Properties of Cracked and Fluid-Saturated Synthetic Glass Media

In this paper, for better understanding of frequency dependence (dispersion) of seismic wave velocities caused by stress-induced fluid flow, broadband laboratory measurements were performed on a suite of synthetic glass media containing both equant pores and thermal cracks. Complementary forced oscillation, resonant bar, and ultrasonic techniques provided access to millihertz-hertz frequencies, ~1 kHz frequency, and ~1 MHz frequency, respectively. The wave speeds or effective elastic moduli and associated dissipation were measured on samples under dry, argon- or nitrogen-saturated, and water-saturated conditions in sequence. The elastic moduli, in situ permeability, and crack porosity inferred from in situ X-ray computed tomography all attest to strong pressure-induced crack closure for differential (confining-minus-pore) pressures <30 MPa, consistent with zero-pressure crack aspect ratios <4 × 10 -4 . The low permeabilities of these materials allow access to undrained conditions, even at subhertz frequencies. The ultrasonically measured elastic moduli reveal consistently higher shear and bulk moduli upon fluid saturation—diagnostic of the saturated-isolated regime. For a glass rod specimen, containing cracks but no pores, saturated-isolated conditions apparently persist to subhertz frequencies—requiring in situ aspect ratios (minimum/maximum dimension) <10 -5 . In marked contrast, the shear modulus measured at subhertz frequencies on a cracked glass bead specimen of 5% porosity, is insensitive to fluid saturation, consistent with the Biot-Gassmann model for the saturated-isobaric regime. Finally, the measured dispersion of the shear modulus approaches 10% over the millihertz-megahertz frequency range for the cracked and fluid-saturated media—implying that laboratory ultrasonic data should be used with care in the interpretation of field data.

58 GEOSCIENCES↗

Capturing soil moisture and salinity changes in flooded coastal forests using electrical resistivity and induced polarization

Geophysical methods provide high-resolution spatial measurements of physical quantities sensitive to changes in soil moisture and salinity and can be used to monitor soil hydrological responses to flooding. However, extracting quantitative hydrological information from geophysical data remains challenging. In this study, we extended existing petrophysical models to estimate soil moisture and salinity from electrical measurements to address this challenge. We manipulated two hydrologically isolated 2000 m 2 experimental plots by simultaneously inundating them with 265 m 3 of either freshwater or estuarine water. Repeated electrical resistivity and induced polarization measurements were used to image the water and solute infiltration along two transects that are 100 and 42 m in length. Petrophysical models derived from laboratory multi-salinity electrical measurements were used to estimate changes in soil moisture and fluid salinity from field measurements of real and imaginary conductivity during the ecosystem-scale flooding experiment. The real conductivity increased by ∼100% in the freshwater plot and ∼570% in the saltwater plot. The change in imaginary conductivity in the freshwater plot was <1 mS/m, whereas that of the estuarine water plot was ∼5 mS/m. Real conductivity shows dependence on soil moisture content with a coefficient of determination (R 2 ) > 0.7, while the imaginary conductivity shows a dependence on soil salinity with R 2 > 0.6. The results validate the use of electrical resistivity for estimating changes in soil moisture content in response to flooding. Combining electrical resistivity imaging with induced polarization measurements provides the possibility to account for changes in pore fluid conductivity.

Adebayo, Moses B. [Univ. of Toledo, OH (United Sta↗