Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLOW RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Experiments on transferring helium II with a thermomechanical pump

Porous plugs were tested as thermomechanical pumps for the transfer of helium II from one dewar to another through a transfer line and two valves. SEM images for two different size porous plugs are presented. The present pump design was shown to transfer 80 liters at a maximum flow rate of 90 liters/hr. Temperature, pressure, flow rate, and heater power data are compared with theoretical results.

Mills, G. L.↗

The flow of a thin liquid film on a stationary and rotating disk. I - Experimental analysis and flow visualization

The mean thickness of a thin liquid film of deionized water with a free surface on a stationary and rotating horizontal disk has been measured with a nonobtrusive capacitance technique. The measurements were taken when the rotational speed was 0-300 RPM and the flow rate was 7.0-15.0 LPM. A flow visualization study of the thin film was also performed to determine the characteristics of the waves on the free surface. When the disk was stationary, a circular hydraulic jump was present on the disk. Surface waves were found in the supercritical and subcritical regions at all flow rates studied. When the rotational speed of the disk is low, a standing wave at the edge of the disk was present. As the rotational speed increased, the surface waves changed from the wavy-laminar region to a region in which the waves ran nearly radially across the disk on top of a thin substrate of fluid.

Thomas, S.↗

Loop Heat Pipe Temperature Oscillation Induced by Gravity Assist and Reservoir Heating

The Laser Thermal Control System (LCTS) for the Advanced Topographic Laser Altimeter System (ATLAS) to be installed on NASA's Ice, Cloud, and Land Elevation Satellite (ICESat-2) consists of a constant conductance heat pipe and a loop heat pipe (LHP) with an associated radiator. During the recent thermal vacuum testing of the LTCS where the LHP condenser/radiator was placed in a vertical position above the evaporator and reservoir, it was found that the LHP reservoir control heater power requirement was much higher than the analytical model had predicted. Even with the control heater turned on continuously at its full power, the reservoir could not be maintained at its desired set point temperature. An investigation of the LHP behaviors found that the root cause of the problem was fluid flow and reservoir temperature oscillations, which led to persistent alternate forward and reversed flow along the liquid line and an imbalance between the vapor mass flow rate in the vapor line and liquid mass flow rate in the liquid line. The flow and temperature oscillations were caused by an interaction between gravity and reservoir heating, and were exacerbated by the large thermal mass of the instrument simulator which modulated the net heat load to the evaporator, and the vertical radiator/condenser which induced a variable gravitational pressure head. Furthermore, causes and effects of the contributing factors to flow and temperature oscillations intermingled.

Thermal Control Systems↗

Loop Heat Pipe Temperature Oscillation Induced by Gravity Assist and Reservoir Heating

The Laser Thermal Control System (LCTS) for the Advanced Topographic Laser Altimeter System (ATLAS) to be installed on NASA's Ice, Cloud, and Land Elevation Satellite (ICESat-2) consists of a constant conductance heat pipe and a loop heat pipe (LHP) with an associated radiator. During the recent thermal vacuum testing of the LTCS where the LHP condenser/radiator was placed in a vertical position above the evaporator and reservoir, it was found that the LHP reservoir control heater power requirement was much higher than the analytical model had predicted. Even with the control heater turned on continuously at its full power, the reservoir could not be maintained at its desired set point temperature. An investigation of the LHP behaviors found that the root cause of the problem was fluid flow and reservoir temperature oscillations, which led to persistent alternate forward and reversed flow along the liquid line and an imbalance between the vapor mass flow rate in the vapor line and liquid mass flow rate in the liquid line. The flow and temperature oscillations were caused by an interaction between gravity and reservoir heating, and were exacerbated by the large thermal mass of the instrument simulator which modulated the net heat load to the evaporator, and the vertical radiator/condenser which induced a variable gravitational pressure head. Furthermore, causes and effects of the contributing factors to flow and temperature oscillations intermingled.

0000↗

Investigation of Multiphase Flow in a Packed Bed Reactor Under Microgravity Conditions

In this paper we study the two-phase flow phenomena in a packed bed reactor using an integrated experimental and numerical method. The cylindrical bed is filled with uniformly sized spheres. In the experiment water and air are injected into the bed simultaneously. The pressure distribution along the bed will be measured. The numerical simulation is based on a two-phase flow solver which solves the Navier-Stokes equations on Cartesian grids. A novel coupled level set and moment of fluid method is used to construct the interface. A sequential method is used to position spheres in the cylinder. Preliminary experimental results showed that the tested flow rates resulted in pulse flow. The numerical simulation revealed that air bubbles could merge into larger bubbles and also could break up into smaller bubbles to pass through the pores in the bed. Preliminary results showed that flow passed through regions where the porosity is high. Comparison between the experimental and numerical results in terms of pressure distributions at different flow injection rates will be conducted. Comparison of flow phenomena under terrestrial gravity and microgravity will be made.

computational fluid dynamics↗

Numerical Simulation of Lean Blowout of Alternative Fuels in 7-element Lean Direct Injector

This research presents the result of numerically simulating 7-element swirl-venturi Lean Direct Injector (SV-LDI) lean blowout (LBO) experiments conducted at NASA Glenn Research Center in May of 2019. After simulating a cold flow case to confirm the pressure drop agrees well with the experiment, additional cases with two different fuels (an average jet fuel and a Gevo alcohol-to-jet fuel) from the National Jet Fuels Combustion Program (NJFCP) were computed to numerically determine the LBO condition. The procedure to approach the LBO follows the method used in the experiment where the air mass flow rate is gradually increased while the fuel supply is maintained. Transient history of global heat release rate as a function of air flow rate is presented, as well as temperature contours at different conditions to give a visual representation of the flame state. The Open National Combustion Code (OpenNCC) used in this research adopted reduced HyChem (Hybrid Chemistry) models along with k-LES turbulence model and a Lagrangian spray model that takes into account droplet internal temperature distribution affected by the shear force on the droplet surface. The transport equations and chemical reaction terms are integrated together to enhance conservation of chemical species that are especially important in the near LBO conditions. After showing the computed range of LBO agrees well with the experimental measurements, time averaged solutions of both fuels at their initial condition and at their limiting condition just before LBO are compared in detail to facilitate the understanding of LBO mechanism.

combustion↗

Two-Dimensional Bifurcated Inlet Variable Cowl Lip Test Completed in 10- by 10-Foot Supersonic Wind Tunnel

Researchers at the NASA Glenn Research Center at Lewis Field successfully tested a variable cowl lip inlet at simulated takeoff conditions in Glenn s 10- by 10-Foot Supersonic Wind Tunnel (10x10 SWT) as part of the High-Speed Research Program. The test was a follow-on to the Two-Dimensional Bifurcated (2DB) Inlet/Engine test. At the takeoff condition for a High-Speed Civil Transport aircraft, the inlet must provide adequate airflow to the engine with an acceptable distortion level and high-pressure recovery. The test was conducted to study the effectiveness of installing two rotating lips on the 2DB Inlet cowls to increase mass flow rate and eliminate or reduce boundary layer flow separation near the lips. Hardware was mounted vertically in the test section so that it extended through the tunnel ceiling and that the 2DB Inlet was exposed to the atmosphere above the test section. The tunnel was configured in the aerodynamic mode, and exhausters were used to pump down the tunnel to vacuum levels and to provide a maximum flow rate of approximately 58 lb/sec. The test determined the (1) maximum flow in the 2DB Inlet for each variable cowl lip, (2) distortion level and pressure recovery for each lip configuration, (3) boundary layer conditions near variable lips inside the 2DB Inlet, (4) effects of a wing structure adjacent to the 2DB Inlet, and (5) effects of different 2DB Inlet exit configurations. It also employed flow visualization to generate enough qualitative data on variable lips to optimize the variable lip concept. This test was a collaborative effort between the Boeing Company and Glenn. Extensive inhouse support at Glenn contributed significantly to the progress and accomplishment of this test.

Hoffman, T. R.↗

Compact and Integrated Liquid Bismuth Propellant Feed System

Operation of Hall thrusters with bismuth propellant has been shown to be a promising path toward high-power, high-performance, long-lifetime electric propulsion for spaceflight missions [1]. There has been considerable effort in the past three years aimed at resuscitating this promising technology and validating earlier experimental results indicating the advantages of a bismuth-fed Hall thruster. A critical element of the present effort is the precise metering of propellant to the thruster, since performance cannot be accurately assessed without an accurate accounting of mass flow rate. Earlier work used a pre./post-test propellant weighing scheme that did not provide any real-time measurement of mass flow rate while the thruster was firing, and makes subsequent performance calculations difficult. The motivation of the present work is to develop a precision liquid bismuth Propellant Management System (PMS) that provides hot, molten bismuth to the thruster while simultaneously monitoring in real-time the propellant mass flow rate. The system is a derivative of our previous propellant feed system [2], but the present system represents a more compact design. In addition, all control electronics are integrated into a single unit and designed to reside on a thrust stand and operate in the relevant vacuum environment where the thruster is operating, significantly increasing the present technology readiness level of liquid metal propellant feed systems. The design of various critical components in a bismuth PMS are described. These include the bismuth reservoir and pressurization system, 'hotspot' flow sensor, power system and integrated control system. Particular emphasis is given to selection of the electronics employed in this system and the methods that were used to isolate the power and control systems from the high-temperature portions of the feed system and thruster. Open loop calibration test results from the 'hotspot' flow sensor are reported, and results of integrated thruster/PMS tests demonstrate operation of the feed system in the relevant environment.

Polzin, Kurt A.↗

Kinetics and Structure of Superagglomerates Produced by Silane and Acetylene

The evolution of smoke in a laminar diffusion flame involves several steps. The first step is particle inception/nucleation in the high-temperature fuel-rich region of the flame followed by surface growth and coagulation/coalescence of the small particles. As the primary spheres grow in size and lose hydrogen, the colliding particles no longer coalesce but retain their identity as a cluster of primary spheres, termed an agglomerate. Finally, in the upper portion of the flame, the particles enter an oxidizing environment which may lead to partial or complete burnout of the agglomerates. Currently there is no quantitative model for describing the growth of smoke agglomerates up to superagglomerates with an overall dimension of 10 microns and greater. Such particles are produced during the burning of acetylene and fuels containing benzene rings such as toluene and polystyrene. In the case of polystyrene, smoke agglomerates in excess of 1 mm have been observed "raining" out from large fires. Evidence of the formation of superagglomerates in a laminar acetylene/air diffusion flame has been recently reported. Acetylene was chosen as the fuel since the particulate loading in acetylene/air diffusion flames is very high. Photographs were obtained by Sorensen using a microsecond xenon lamp of the "stream" of soot just above the flame. For low flow rates of acetylene, only submicrometer soot clusters are produced and they give rise to the homogeneous appearance of the soot stream. When the flow rate is increased to 1.7 cu cm/s, soot clusters up to 10 microns are formed and they are responsible for the graininess and at a flow rate of 3.4 cu cm/s, a web of interconnected clusters as large as the width of the flame is seen. This interconnecting web of superagglomerates is described as a gel state by Sorensen et al (1998). This is the first observation of a gel for a gas phase system. It was observed that this gel state immediately breaks up into agglomerates due to buoyancy induced turbulence and gravitational sedimentation.

Mulholland, G. W.↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Liquid hydrogen suction dip and slosh wave excitation during draining under normal and reduced gravity environments

The paper discusses the dynamical behavior of vapor ingestion, liquid residual at the incipience of suction dip, slosh wave excitation under normal and reduced gravity and different flow rates during liquid hydrogen draining. Liquid residuals at the incipience of suction dip increase as the values of gravity decrease. Also liquid residuals increase with the draining flow rates. Lower ratio of Bond number and Weber number are unable to excite slosh waves. Lower flow rates and higher gravity excites waves with lower frequencies and higher wave amplitude slosh waves.

Hung, R. J.↗

A Burning Rate Emulator (BRE) for Study in Microgravity

A gas-fueled burner, the Burning Rate Emulator (BRE), is used to emulate condensed-phase fuel flames. The design has been validated to easily measure the burning behavior of condensed-phase fuels by igniting a controlled stream of gas fuel and diluent. Four properties, including the heat of combustion, the heat of gasification, the surface temperature, and the laminar smoke point, are assumed to be sufficient to define the steady burning rate of a condensed-phase fuel. The heat of gasification of the fuel is determined by measuring the heat flux and the fuel flow rate. Microgravity BRE tests in the NASA 5.2 s drop facility have examined the burning of pure methane and ethylene (pure and 50 in N2 balance). Fuel flow rates, chamber oxygen concentration and initial pressure have been varied. Two burner sizes, 25 and 50 mm respectively, are chosen to examine the nature of initial microgravity burning. The tests reveal bubble-like flames that increase within the 5.2s drop but the heat flux received from the flame appears to asymptotically approach steady state. Portions of the methane flames appear to locally detach and extinguish at center, while its shape remains fixed, but growing. The effective heat of gasification is computed from the final measured net heat flux and the fuel flow rate under the assumption of an achieved steady burning. Heat flux (or mass flux) and flame position are compared with stagnant layer burning theory. The analysis offers the prospect of more complete findings from future longer duration ISS experiments.

diffusion flames↗

Ammonia Offgassing from SA9T

NH3 is a degradation product of SA9T, a solid-amine sorbent developed by Hamilton Sundstrand, that is continually emitted into the gas stream being conditioned by this sorbent. NH3 offgassing rates were measured using FTIR spectroscopy using a packed bed at similar contact times as offgassing tests conducted at Hamilton Sundstrand and at the Ames Research Center. The bed was challenged with moist air at several flow rates and humidities and NH3 concentration of the effluent was measured for several hours. The NH3 offgassing rates in open-loop testing were calculated from the steady state outlet NH3 concentration and flow rate. NH3 offgassing rates from SA9T were found to be influenced by the contact time with the adsorbent (flow rate) and by the humidity of the inlet gas stream, which are consistent with previous studies. Closed-loop vacuum-swing adsorption cycling rates verified that NH3 offgassing continues when a constant source of water vapor is present.

Monje, Oscar↗

Effects of Background Pressure and Electrical Configuration on the Velocity Field of the HERMeS Hall Thruster

A Laser-Induced Fluorescence test was performed during risk reduction testing on the HERMeS Hall thruster. This article focuses on the portion of the test to study trends in the ion acceleration characteristics with varying anode mass flow rate, background pressure, and electrical configuration. The acceleration zone of the HERMeS Hall thruster was observed to move upstream as the anode mass flow rate decreased and upstream as the background pressure increased. Examination of the characteristics of the ions near the pole covers suggested the possibility that thruster was no longer magnetically shielded at the extreme conditions of very low anode mass flow rate and high background pressure. The acceleration zone was also observed to move slightly upstream when the thruster body was floated as opposed to cathode-tied and did not move appreciably when the thruster body was grounded to the vacuum facility. Characteristics of the ions bombarding the pole covers did not vary across the tested electrical configurations.

Electric Propulsion↗

Propulsion System Testing for the Iodine Satellite (iSAT) Demonstration Mission

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload, providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cm cu and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high delta v maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Recently, work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) 2 that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. 3, 4 Iodine stores as a dense solid at very low pressures, making it acceptable as a propellant on a secondary payload. It has exceptionally high ρIsp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing the potential for systems-level advantages over mid-term high power electric propulsion options. Iodine flow can also be thermally regulated, subliming at relatively low temperature (less than 100 C) to yield I2 vapor at or below 50 torr. At low power, the measured performance of an iodine-fed HET is very similar to that of a state-of-the-art xenon-fed thruster. Just as importantly, the current-voltage discharge characteristics of low power iodine-fed and xenon-fed thrusters are remarkably similar, potentially reducing development and qualifications costs by making it possible to use an already-qualified xenon-HET PPU in an iodine-fed system. Finally, a cold surface can be installed in a vacuum test chamber on which expended iodine propellant can deposit. In addition, the temperature doesn't have to be extremely cold to maintain a low vapor pressure in the vacuum chamber (it is under 10(exp -6) torr at −75 C), making it possible to 'cryopump' the propellant with lower-cost recirculating refrigerant-based systems as opposed to using liquid nitrogen or low temperature gaseous helium cryopanels. An iodine-based system is not without its challenges. The primary challenge is that the entire feed system must be maintained at an elevated temperature to prevent the iodine from depositing (transitioning from the gas phase directly back into the solid phase), which will block the propellant feed lines. Furthermore, deposition will occur unless the temperature in the lines is not greater than the temperature of the propellant reservoir. The flow rate can be controlled by adjusting the heating applied to the reservoir, but as with any thermal control there is a relatively slow response to changes in the heating rate. In the present paper, we describe the propulsion and propellant feed system for the iodine satellite (iSAT) flight demonstration mission. The system is based around the Busek BHT-200 Hall thruster, which has been modified for chemical compatibility with iodine vapor. While the gross propellant flow rate is maintained by the heated propellant reservoir, the flow to the anode and cathode are adjusted using two heated Vacco proportional flow control valves (PFCV), which provide very fast response on the flow rate adjustment. The flight mission design layout will be presented, showing how the system will be packaged into the overall 12-U spacecraft and the techniques being employed to protect the remaining spacecraft hardware from the propulsion system (e.g., plasma impingement, iodine deposition, thermal loads). In addition to the flight system design, results of testing the thruster and cathode with both operating on iodine propellant are presented. The tests are conducted on a thrust stand (see Fig. 1) in a large vacuum chamber containing a beam dump chilled to below -100 C to 'cryopump' the propellant. The thruster performance during these tests is presented, with these data used to evaluate the feed system and guide further refinements. Results of relatively long duration testing are presented to demonstrate the capability to operate for the length of the iSAT mission and to perform a number of re-starts as will be required by the mission concept of operations.

Polzin, Kurt A.↗

The Thermal Response of a Packed Bed Thermal Energy Storage System upon Saturated Steam Injection Using Distributed Temperature Sensing

The effectiveness of a thermal energy storage (TES) system is typically characterized with the help of thermal stratification or temperature gradients along the direction of heat injection, which is typically the flow direction of heat transfer fluid. The steepness of temperature gradients are a direct indicator of the effectiveness or efficiency of the heat storage or dispatch process. The temperature gradient evolution along the packed bed of ceramic particles upon saturated steam injection is presented in this work. Distributed temperature sensing based on optical frequency domain reflectometry was deployed in a packed bed of ceramic particles to capture the thermal front evolution in the axial direction. The physical processes accompanying steam injection in packed beds are complex due to phase change, transitioning two-phase flow, and changes in condensate accumulation. Therefore, the variation of thermal response of the TES system for various steam injection flow rates was experimentally studied using a high-resolution distributed temperature sensing system in a chemically inert alumina particle-packed bed. Distinct zones of different heat transfer modes were observed during the steam injection experiments. A distinct conduction zone, evident from diffuse thermal fronts, was observed at low flow rates, and these thermal gradients became sharper as the flow rate increased. The diffuse thermal fronts in the heat storage media suggest a low exergy efficiency of the TES system, as energy losses started initiating before a significant fraction of the bed was saturated with steam.

25 ENERGY STORAGE↗

NEXIS Reservoir Cathode 2000 Hour Life Test

The current design of the Nuclear Electric Xenon Ion System (NEXIS) employs a reservoir cathode as both the discharge and neutralizer cathode to meet the 10 yr thruster design life. The main difference between a reservoir cathode and a conventional discharge cathode is the source material (barium-containing compound) is contained within a reservoir instead of in an impregnated insert in the hollow tube. However, reservoir cathodes do not have much life test history associated with them. In order to demonstrate the feasibility of using a reservoir cathode as an integral part of the NEXIS ion thruster, a 2000 hr life test was performed. Several proof-of-concept (POC) reservoir cathodes were built early in the NEXIS program to conduct performance testing as well as life tests. One of the POC cathodes was sent to Marshall Space Flight Center (MSFC) where it was tested for 2000 hrs in a vacuum chamber. The cathode was operated at the NEXIS design point of 25 A discharge current and a xenon flow rate of 5.5 sccm during the 2000 hr test. The cathode performance parameters, including discharge current, discharge voltage, keeper current; keeper voltage, and flow rate were monitored throughout test. Also, the temperature upstream of cathode heater, the temperature downstream of the cathode heater, and the temperature of the orifice plate were monitored throughout the life of the test. The results of the 2000 hr test will be described in this paper. Included in the results will be time history of discharge current, discharge voltage, and flow rate. Also, a time history of the cathode temperature will be provided.

Vaughn, Jason↗

Flux Recovery of a Forward Osmosis Membrane After a Fouling Process

Wastewater treatment through Forward Osmosis (FO) membranes is a process that has been evaluated in the past years as an innovative technology for the Next Generation Life Support Systems. FO technologies are cost effective, and require very low energy consumption, but are subject to membrane fouling. Membrane fouling occurs when unwanted materials accumulate on the active side of the membrane during the wastewater treatment process, which leads to a decrease in membrane flow rates. Membrane fouling can be reversed with the use of antifoulant solutions. The aim of this study is to identify the materials that cause flow rate reduction due to membrane fouling, as well as to evaluate the flux recovery after membrane treatment using commercially available antifoulants. 3D Laser Scanning Microscope images were taken to observe the surface of the membrane. Fourier Transform Infrared (FTIR) spectrometry results identified possible compounds that cause membrane fouling and FO testing results demonstrated flow rate recovery after membrane treatment using antifoulants.

Forward osmosis↗