Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

SU-E-J-150: Impact of Intrafractional Prostate Motion On the Accuracy and Efficiency of Prostate SBRT Delivery: A Retrospective Analysis of Prostate Tracking Log Files

Purpose: To measure intrafractional prostate motion by time-based stereotactic x-ray imaging and investigate the impact on the accuracy and efficiency of prostate SBRT delivery. Methods: Prostate tracking log files with 1,892 x-ray image registrations from 18 SBRT fractions for 6 patients were retrospectively analyzed. Patient setup and beam delivery sessions were reviewed to identify extended periods of large prostate motion that caused delays in setup or interruptions in beam delivery. The 6D prostate motions were compared to the clinically used PTV margin of 3–5 mm (3 mm posterior, 5 mm all other directions), a hypothetical PTV margin of 2–3 mm (2 mm posterior, 3 mm all other directions), and the rotation correction limits (roll ±2°, pitch ±5° and yaw ±3°) of CyberKnife to quantify beam delivery accuracy. Results: Significant incidents of treatment start delay and beam delivery interruption were observed, mostly related to large pitch rotations of ≥±5°. Optimal setup time of 5–15 minutes was recorded in 61% of the fractions, and optimal beam delivery time of 30–40 minutes in 67% of the fractions. At a default imaging interval of 15 seconds, the percentage of prostate motion beyond PTV margin of 3–5 mm varied among patients, with a mean at 12.8% (range 0.0%–31.1%); and the percentage beyond PTV margin of 2–3 mm was at a mean of 36.0% (range 3.3%–83.1%). These timely detected offsets were all corrected real-time by the robotic manipulator or by operator intervention at the time of treatment interruptions. Conclusion: The durations of patient setup and beam delivery were directly affected by the occurrence of large prostate motion. Frequent imaging of down to 15 second interval is necessary for certain patients. Techniques for reducing prostate motion, such as using endorectal balloon, can be considered to assure consistently higher accuracy and efficiency of prostate SBRT delivery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-P-36: Evaluation of MLC Positioning Errors in Dynamic IMRT Treatments by Analyzing Dynalog Files

Purpose: To assess the accuracy of MLC positioning in Varian linear accelerator, in dynamic IMRT technique, from the analysis of dynalog files generated by the MLC controller. Methods: In Clinac accelerators (pre-TrueBeam technology), control system has an approximately 50ms delay (one control cycle time). Then, the system compares the measured position to the planned position corresponding to the next control cycle. As it has been confirmed by Varian technical support, this effect causes that measured positions appear in dynalogs one cycle out of phase with respect to the planned positions. Around 9000 dynalogs have been analyzed, coming from the three linear accelerators of our center (one Trilogy and two Clinac 21EX) equipped with a Millennium 120 MLC. In order to compare our results to recent publications, leaf positioning errors (RMS and 95th percentile) are calculated with and without delay effect. Dynalogs have been analyzed using a in-house Matlab software. Results: The RMS errors were 0.341, 0.339 and 0.348mm for each Linac; being the average error 0.343 mm. The 95th percentiles of the error were 0.617, 0.607 and 0.625; with an average of 0.617mm. A recent multi-institution study carried out by Kerns et al. found a mean leaf RMS error of 0.32mm and a 95th percentile error value of 0.64mm.Without delay effect, mean leaf RMS errors obtained were 0.040, 0.042 and 0.038mm for each treatment machine; being the average 0.040mm. The 95th percentile error values obtained were 0.057, 0.058 and 0.054 mm, with an average of 0.056mm. Conclusion: Results obtained for the mean leaf RMS error and the mean 95th percentile were consistent with the multi-institution study. Calculated error statistics with delay effect are significantly larger due to the speed proportional and systematic leaf offset. Consequently it is proposed to correct this effect in dynalogs analysis to determine the MLC performance.

60 APPLIED LIFE SCIENCES↗

SU-E-T-644: QuAArC: A 3D VMAT QA System Based On Radiochromic Film and Monte Carlo Simulation of Log Files

Purpose: VMAT involves two main sources of uncertainty: one related to the dose calculation accuracy, and the other linked to the continuous delivery of a discrete calculation. The purpose of this work is to present QuAArC, an alternative VMAT QA system to control and potentially reduce these uncertainties. Methods: An automated MC simulation of log files, recorded during VMAT treatment plans delivery, was implemented in order to simulate the actual treatment parameters. The linac head models and the phase-space data of each Control Point (CP) were simulated using the EGSnrc/BEAMnrc MC code, and the corresponding dose calculation was carried out by means of BEAMDOSE, a DOSXYZnrc code modification. A cylindrical phantom was specifically designed to host films rolled up at different radial distances from the isocenter, for a 3D and continuous dosimetric verification. It also allows axial and/or coronal films and point measurements with several types of ion chambers at different locations. Specific software was developed in MATLAB in order to process and evaluate the dosimetric measurements, which incorporates the analysis of dose distributions, profiles, dose difference maps, and 2D/3D gamma index. It is also possible to obtain the experimental DVH reconstructed on the patient CT, by an optimization method to find the individual contribution corresponding to each CP on the film, taking into account the total measured dose, and the corresponding CP dose calculated by MC. Results: The QuAArC system showed high reproducibility of measurements, and consistency with the results obtained with the commercial system implemented in the verification of the evaluated treatment plans. Conclusion: A VMAT QA system based on MC simulation and high resolution dosimetry with film has been developed for treatment verification. It shows to be useful for the study of the real VMAT capabilities, and also for linac commissioning and evaluation of other verification devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

UNITY: Unified Memory and File Space. In: ROSS '17 Proceedings of the 7th International Workshop on Runtime and Operating Systems for Supercomputers ROSS 2017, Article No. 6

This paper describes the vision for UNITY, a new high-performance computing focused data storage abstraction that places the entire memory hierarchy, including both traditionally separated memory-and file-based data storage, into one storage continuum. Through the use of a novel API and a set of services centered around a smart runtime system, UNITY is able to provide a number of valuable and interesting benefits. The unified storage space provides a scalable and resilient data environment that dynamically manages the mapping of data onto available resources based on multiple factors, including desired persistence and energy budget considerations. By eliminating the need for high-performance computing domain scientists to develop architecture-dependent optimizations for rapidly evolving data storage technologies, UNITY addresses both ease-of-use and performance.

Jones, Terry↗

Spify Parser of Input Files with YAML syntax

SPIFY is a C++ library for parsing input files to be used in scientific computing applications. The library allows an application developer to define a full set of required and optional input variable of different types and handles all of the parsing and validation.

Whitesides, Russell↗

UnifyFS: A Distributed Burst Buffer File System - 0.1.0

UnifyFS is a user-level burst buffer file system under active development. UnifyFS supports scalable and efficient aggregation of I/O bandwidth from burst buffers while having the same life cycle as a batch-submitted job. While UnifyFS is designed for N-N write/read, UnifyFS compliments its functionality with the support for N-1 write/read. It efficiently accelerates scientific I/O based on scalable metadata indexing, co-located I/O delegation, and server-side read clustering and pipelining.

ECP↗

Software Library for Bruker TopSpin NMR Data Files

A software library for parsing and manipulating frequency-domain data files that have been processed using the Bruker TopSpin NMR software package. In the context of NMR, the term "processed" indicates that the end-user of the Bruker TopSpin NMR software package has (a) Fourier transformed the raw, time-domain data (the Free Induction Decay) into the frequency-domain and (b) has extracted the list of NMR peaks.

Source record↗

SCALE Input and Result Files Supporting SCALE Inventory and Reactivity Analysis as Part of the Hermes 2021 PSAR Review

This dataset contains input and result files of computational simulations with the SCALE code system. The simulations cover radionuclide inventory and reactivity analyses of a fluoride salt-cooled high temperature pebble-bed reactor (PB-FHR), specifically the Hermes low-power PB-FHR demonstration reactor. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

equilibrium core↗

SCALE Input and Result Files Supporting SCALE Inventory and Reactivity Analysis of the gFHR

This dataset contains input and result files of computational simulations with the SCALE code system. The simulations cover radionuclide inventory and reactivity analyses of a fluoride salt-cooled high temperature pebble-bed reactor (PB-FHR), specifically the generic FHR benchmark. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cascades/Aleutian Play Fairway Analysis: Data and Map Files

Contains Excel data files used to quantifiably rank the geothermal potential of each of the young volcanic centers of the Cascade and Aleutian Arcs using world power production volcanic centers as benchmarks. Also contains shapefiles used in play fairway analysis with power plant, volcano, geochemistry and structural data.

15 GEOTHERMAL ENERGY↗

BRAD BRDY and BRD1 GPS Station RINEX Files 09-17-2015

CSV files with links to RINEX data for stations BRAD and BRDY for all days after those reported previous (i.e., since 21-JAN-2015) Links to websites that show the position time-series of both stations.

15 GEOTHERMAL ENERGY↗

GEOPHIRES files for DDU techno-economic simulations

During 2017-2019, the U.S. Department of Energy funded six geothermal deep direct-use (DDU) projects to investigate feasibility of DDU for heating, cooling and thermal storage in the United States. In a follow-on study conducted at the National Renewable Energy Laboratory (NREL), findings of these six projects were reviewed and analyzed, and additional simulations were conducted using the simulator GEOPHIRES to explore technical performance and cost-competitiveness of DDU. The results of the NREL study were published in the paper "Evaluating the Feasibility of Geothermal Deep Direct-Use in the United States." The GEOPHIRES files developed in that study are included in this submission. The reference for the paper under review is below: Beckers KF, Kolker A, Pauling H, McTigue JD, and Kesseli D (2021) ?Evaluating the Feasibility of Geothermal Deep Direct-Use in the United States?, Submitted to Energy Conversion and Management, Under Review.

15 GEOTHERMAL ENERGY↗

EGS-Collab Experiment 1: Time-lapse ERT Data and E4D Inversion Files for 10-24-2018 through 11-07-2018 Flow Test

This data submission includes the raw time-lapse ERT (electrical resistivity tomography) monitoring data, flow system data, operator logs, E4D (https://e4d.pnnl.gov) inversion files, and meta-data necessary to reproduce the 4D ERT inversion for the Oct. 24 through Nov. 7 2018 post-stimulation flow test in test bed 1. The tests were done at the Sanford Underground Research Facility at Homestake Mine in South Dakota.

15 GEOTHERMAL ENERGY↗

Advanced TidGen Power System - ProteusDS Version 2.43.5 Files

The TidGen Power System generates emission-free electricity from tidal currents and connects directly into existing grids using smart grid technology. The power system consists of three major subsystems: shore-side power electronics, mooring system, and turbine generator unit (TGU) device. ProteusDS is a full featured dynamic analysis software capable of simulating vessels, structures, lines, and technologies in harsh marine environments. This simulation software that was used to test the Advanced TidGen Power System. This submission includes the supporting Proteus simulation files.

16 TIDAL AND WAVE POWER↗