Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Extreme Conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Time resolved x-ray diffraction in shock compressed systems

The availability of pulsed x rays on short timescales has opened up new avenues of research in the physics and chemistry of shocked materials. The continued installation of shock platforms such as gas guns and high power lasers placed at beamline x-ray facilities has advanced our knowledge of materials shocked to extreme conditions of pressure and temperature. In addition, theoretical advancements have made direct correspondence with high-pressure x-ray experiments more viable, increasing the predictive capability of these models. In this paper, we discuss both recent experimental results and the theory and modeling that has been developed to treat these complex situations. Finally, we discuss the impact that new platforms and increased beam time may have on the future direction of this field.

36 MATERIALS SCIENCE↗

Pressure-induced spin crossover in a Fe 78 Si 9 B 13 metallic glass

The pressure effect on structures and properties of a Fe 78 Si 9 B 13 metallic glass was investigated by in situ high-pressure synchrotron Fe Kβ x-ray emission spectroscopy and x-ray diffraction, and electrical resistivity measurements up to ~51 GPa. The study reveals a reversible and continuous pressure-induced high- to low-spin crossover of Fe atoms in an amorphous structure. The changes of the local spin moment can be scaled to match its average atomic distance shrinkage very well during compression. The crossover of electronic spin states in the Fe 78 Si 9 B 13 metallic glass resembles that of typical crystalline Fe-bearing materials but without a sharp atomic volume collapse and an abrupt electrical resistivity jump. Furthermore, these findings could help guide applications of Fe-based metallic glasses as a soft ferromagnetic material at extreme conditions and also improve our understanding of magnetism and coupling of its changes with disordered atomic structures and other properties in metallic glasses.

36 MATERIALS SCIENCE↗

In Situ X-ray Diffraction of High Density Polyethylene During Dynamic Compression: Polymer Chain Compression and Phase Transformations

Polymers are widely implemented materials often used for safety and security in our daily lives. However, we do not have a thorough understanding of the phase transformations of these materials when exposed to extreme condition, high strain rate, events. To study polymers in these severe environments, we performed plate impact experiments that impart a one-dimensional shock wave, at high pressures and temperatures, to observe the materials response. Generally, velocimetry is the experimental diagnostic used to capture the movement of high velocity interfaces to then calculate the mechanical variables associated with shock compression. However, when a material undergoes a phase transition, such as between two crystalline phases or melting to decomposition during shock compression, velocimetry does not explicitly indicate what structural change occurred. At the Dynamic Compression Sector at the Advanced Photon Source gas gun driven compression has been paired with x-ray diffraction, providing the ability to study both the shock parameters and structural changes concurrently. We explored high density polyethylene (HDPE) both on its reactants Hugoniot (<10.12 GPa) and within its transition region (24.3 GPa) where HDPE is hypothesized to decompose from reactants to products. With x-ray diffraction we observed both polymer chain compression and crystal structure reorientation from orthorhombic to monoclinic above 6 GPa, as well as either a possible phase change or chemical decomposition at 24.3 GPa. With these experiments we were able to determine the crystalline and amorphous Hugoniot loci at pressures below the polymer transition region.

36 MATERIALS SCIENCE↗

Using extended MHD to explore lasers as a trigger for x-pinches

X-pinches have been shown to be a source of extremely intense x-ray emissions useful for diagnosing plasma dynamics and imaging biological objects. The most striking feature of an x-pinch is the hotspot, the point source from where all the x rays come from. Unfortunately, the exact timing and location of the hotspot are still unpredictable. Since an x-pinch hotspot forms from instabilities (like an m = 0 mode), we will computationally explore whether we can use a high-power laser to control the timing and location of these instabilities. Our goal is to reduce the temporal and spatial jitter associated with the x-ray burst. Using an extended MHD (XMHD) code, we explore the non-relativistic instability generation using a current profile of a 250 kA linear transformer driver system and laser characteristics of SLAC's Matter in Extreme Conditions laboratory. Our results include both laser-penetration results using a boundary-defined electromagnetic (EM) wave and instability results from a power-deposition method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strength of tantalum to 276 GPa determined by two x-ray diffraction techniques using diamond anvil cells

Tantalum (Ta) is a metal that has useful properties that make it useful in extreme environments. It is therefore important to understand how Ta performs in such extreme conditions by accurately measuring its properties. In this work, the yield strength of tantalum has been measured at pressures up to 276 GPa using axial and radial x-ray diffraction (XRD) methods in diamond anvil cells (DAC). We measured strength using XRD in a radial DAC to 50 GPa, in an axial DAC to 60 GPa using diamonds with standard flat culets, and in a final experiment to 276 GPa using toroidal diamond anvils. The radial XRD data were refined using the Material Analysis Using Diffraction (MAUD) Rietveld software package to extract lattice strain and the yield strength. The axial data were refined using the General Structure Analysis System (GSAS) II and a linewidth method was used to calculate the yield strength. The yield strength measured near ambient pressure was found to be 0.5 GPa and increased with pressure up to 50 GPa, where the yield strength plateaued at a value of 2.4 GPa. At pressures above 60 GPa, the strength increased again to a maximum value of 9 GPa at the highest pressure of 276 GPa. Here, the data from the three experiments show good agreement between the methods and previously reported experimental data. This agreement illustrates the value of axial diffraction data for material strength determination and allows for measurements at multihundreds of GPa using toroidal DACs.

36 MATERIALS SCIENCE↗

Observations on the deformation of metal microspheres in shock-driven polymer flows

We report that solid particles can be fragmented by a fast-moving fluid if their velocity difference is great enough, such as during the atmospheric entry of meteoroids or the shock compression of engineered particulate composites. The extent of particle deformation and breakup in such systems is poorly understood because the necessary extreme conditions make observation difficult and data scarce. To meet this need, experiments combining ultrafast synchrotron-based radiography with plate impact loading were performed at the dynamic compression sector at the advanced photon source. Metal microspheres of several densities and strengths (Au, Ta, and W) were placed inside a polymer matrix. A planar shock wave was then produced in the polymer by the impact of a gun-launched flyer plate. X-ray images of the resulting flow were collected at ~150ns intervals. These images document the progression of particle deformation across a range of flow conditions and particle materials. They show that the extent of deformation is sensitive to the ratio of drag stress to particle strength. The deforming particle's shape is determined by the initial shock–particle interaction, fluid stagnation pressure, and vorticity, each acting on its own timescale. A set of scaling relationships is presented to capture these observations and enable comparison with prior hydrodynamic data. The result is a framework for predicting the conditions under which strong particles are severely deformed by a shock-driven flow.

36 MATERIALS SCIENCE↗

Resonant torque differential magnetometry with high frequency quartz oscillators

Sensitive magnetometry has been a powerful probe for investigating quantum materials. Extreme conditions, such as sub-kelvin cryogenic temperatures and ultrahigh magnetic fields, demand further durability for sensitive magnetometry. However, significant mechanical vibrations and rapid magnetic field changes give enormous challenges to conventional magnetometry. Here, this article presents a possible solution to this problem by developing a new magnetometry technique using high-frequency quartz oscillators. The technique takes advantage of the symmetry and geometry of mechanical vibration configurations of standard commercially available MHz quartz oscillators, and the setup keeps the high quality factor resonance with the sample mounted on the oscillator. We further demonstrate the sensitivity of the technique using bismuth single crystals and a Fe 0.25 TaS 2 ferromagnetic material. Quantum oscillations are observed in the magnetometry response below 1 T, and the detected oscillation frequency is shown to come from the electron pockets of the bismuth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Highly ordered graphite (HOPG) to hexagonal diamond (lonsdaleite) phase transition observed on picosecond time scales using ultrafast x-ray diffraction

Here, the response of rapidly compressed highly oriented pyrolytic graphite (HOPG) normal to its basal plane was investigated at a pressure of ~80 GPa. Ultrafast x-ray diffraction using ~100 fs pulses at the Materials Under Extreme Conditions sector of the Linac Coherent Light Source was used to probe the changes in crystal structure resulting from picosecond timescale compression at laser drive energies ranging from 2.5 to 250 mJ. A phase transformation from HOPG to a highly textured hexagonal diamond structure is observed at the highest energy, followed by relaxation to a still highly oriented, but distorted graphite structure following release. We observe the formation of a highly oriented lonsdaleite within 20 ps, subsequent to compression. This suggests that a diffusionless martensitic mechanism may play a fundamental role in phase transition, as speculated in an early work on this system, and more recent static studies of diamonds formed in impact events.

58 GEOSCIENCES↗

Femtosecond diffraction and dynamic high pressure science

Solid-state material at high pressure is prevalent throughout the Universe, and an understanding of the structure of matter under such extreme conditions, gleaned from x-ray diffraction, has been pursued for the best part of a century. The highest pressures that can be reached to date (2 TPa) in combination with x-ray diffraction diagnosis have been achieved by dynamic compression via laser ablation. The past decade has witnessed remarkable advances in x-ray technologies, with novel x-ray Free-Electron-Lasers (FELs) affording the capacity to produce high quality single-shot diffraction data on timescales below 100 fs. We provide a brief history of the field of dynamic compression, spanning from when the x-ray sources were almost always laser-plasma based, to the current state-of-the art diffraction capabilities provided by FELs. We give an overview of the physics of dynamic compression, diagnostic techniques, and the importance of understanding how the rate of compression influences the final temperatures reached. We provide illustrative examples of experiments performed on FEL facilities that are starting to give insight into how materials deform at ultrahigh strain rates, their phase diagrams, and the types of states that can be reached. We emphasize that there often appear to be differences in the crystalline phases observed between the use of static and dynamic compression techniques. We give our perspective on both the current state of this rapidly evolving field and some glimpses of how we see it developing in the near-to-medium term.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffraction enhanced imaging utilizing a laser produced x-ray source

Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ~2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm 2 and 2 × 40 μm 2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.

3D printing↗

Novel fabrication tools for dynamic compression targets with engineered voids using photolithography methods

Mesoscale imperfections, such as pores and voids, can strongly modify the properties and the mechanical response of materials under extreme conditions. Tracking the material response and microstructure evolution during void collapse is crucial for understanding its performance. In particular, imperfections in the ablator materials, such as voids, can limit the efficiency of the fusion reaction and ultimately hinder ignition. To characterize how voids influence the response of materials during dynamic loading and seed hydrodynamic instabilities, we, in this paper, have developed a tailored fabrication procedure for designer targets with voids at specific locations. Our procedure uses SU-8 as a proxy for the ablator materials and hollow silica microspheres as a proxy for voids and pores. By using photolithography to design the targets’ geometry, we demonstrate precise and highly reproducible placement of a single void within the sample, which is key for a detailed understanding of its behavior under shock compression. This fabrication technique will benefit high-repetition rate experiments at x-ray and laser facilities. Insight from shock compression experiments will provide benchmarks for the next generation of microphysics modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray imaging methods for high-energy density physics applications

Large scale high-energy density science facilities continue to grow in scale and complexity worldwide. The increase in driver capabilities, including pulsed-power and lasers, continue to push the boundaries of temperature, pressure, and densities, opening up new physics regimes. X-ray imaging is one of the many diagnostic techniques that are used to probe states of matter in these extreme conditions. Improved fabrication and polishing methods have provided improved x-ray microscope performance, while improving detector and x-ray sources now enable pico-second imaging with few micron resolutions. Here this Review will cover x-ray imaging methods, primarily absorption imaging, and their improvements over the last few decades.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heat capacity of microgram oxide samples by fast scanning calorimetry

Quantitative scanning calorimetry on microgram-sized samples opens a broad, new range of opportunities for studying the thermodynamic properties of quantity-limited materials, including those produced under extreme conditions or found as rare accessory minerals in nature. We calibrated the Mettler Toledo Flash DSC 2+ calorimeter to obtain quantitative heat capacities in the range 200–350 °C, using samples weighing between 2 and 11.5 μg. Our technique is applied to a new set of oxide materials to which it has never been used before, without the need for melting, glass transitions, or phase transformations. Heat capacity data were obtained for silica in the high pressure stishovite (rutile) structure, dense post-stishovite glass, standard fused quartz, and for TiO2 rutile. These heat capacities agree within 5%–15% with the literature values reported for rutile, stishovite, and fused SiO2 glass. The heat capacity of post-stishovite glass, made by heating stishovite to 1000 °C, is a newly reported value. After accurate calibrations, measured heat capacities were then used to calculate masses for samples in the microgram range, a substantial improvement over measurement in conventional microbalances, which have uncertainties approaching 50%–100% for such small samples. Since the typical uncertainty of heat capacities measured on 10–100 mg samples in conventional differential scanning calorimetry is typically 7% (1%–5% with careful work), flash differential scanning calorimetry, using samples a factor of 1000 smaller, increases the uncertainty of heat capacity measurements by a factor of <3, opening the door for meaningful measurements on ultra-small, high-pressure samples and other quantity-limited materials.

Instruments & Instrumentation↗

Graphite resistive heated diamond anvil cell for simultaneous high-pressure and high-temperature diffraction experiments

High-pressure and high-temperature experiments using a resistively heated diamond anvil cell have the advantage of heating samples homogeneously with precise temperature control. Here, we present the design and performance of a graphite resistive heated diamond anvil cell (GRHDAC) setup for powder and single-crystal x-ray diffraction experiments developed at the Extreme Conditions Beamline (P02.2) at PETRA III, Hamburg, Germany. In the GRHDAC, temperatures up to 2000 K can be generated at high pressures by placing it in a water-cooled vacuum chamber. Temperature estimates from thermocouple measurements are within +/–35 K at the sample position up to 800 K and within +90 K between 800 and 1400 K when using a standard seat combination of cBN and WC. Isothermal compression at high temperatures can be achieved by employing a remote membrane control system. Importantly, the advantage of the GRHDAC is demonstrated through the study of geophysical processes in the Earth’s crust and upper mantle region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

High-pressure and temperature neural network reactive force field for energetic materials

Reactive force fields for molecular dynamics have enabled a wide range of studies in numerous material classes. These force fields are computationally inexpensive compared with electronic structure calculations and allow for simulations of millions of atoms. However, the accuracy of traditional force fields is limited by their functional forms, preventing continual refinement and improvement. Therefore, we develop a neural network-based reactive interatomic potential for the prediction of the mechanical, thermal, and chemical responses of energetic materials at extreme conditions. The training set is expanded in an automatic iterative approach and consists of various CHNO materials and their reactions under ambient and shock-loading conditions. Further, this new potential shows improved accuracy over the current state-of-the-art force fields for a wide range of properties such as detonation performance, decomposition product formation, and vibrational spectra under ambient and shock-loading conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MHz free electron laser x-ray diffraction and modeling of pulsed laser heated diamond anvil cell

A new diamond anvil cell experimental approach has been implemented at the European x-ray Free Electron Laser, combining pulsed laser heating with MHz x-ray diffraction. In this report we use this setup to determine liquidus temperatures under extreme conditions, based on the determination of time-resolved crystallization. The focus is on a Fe-Si-O ternary system, relevant for planetary cores. This time-resolved diagnostic is complemented by a finite-element model, reproducing temporal temperature profiles measured experimentally using streaked optical pyrometry. This model calculates the temperature and strain fields by including (i) pressure and temperature dependencies of material properties, and (ii) the heat-induced thermal stress, including feedback effect on material parameter variations. Making our model more realistic, these improvements are critical as they give 7000 K temperature differences compared to previous models. Laser intensities are determined by seeking minimal deviation between measured and modeled temperatures. Combining models and streak optical pyrometry data extends temperature determination below detection limit. The presented approach can be used to infer the liquidus temperature by the appearance of SiO 2 diffraction spots. In addition, temperatures obtained by the model agree with crystallization temperatures reported for Fe–Si alloys. Our model reproduces the planetary relevant experimental conditions, providing temperature, pressure, and volume conditions. Those predictions are then used to determine liquidus temperatures at experimental timescales where chemical migration is limited. This synergy of novel time-resolved experiments and finite-element modeling pushes further the interpretation capabilities in diamond anvil cell experiments.

36 MATERIALS SCIENCE↗

Laser-driven ramp-compression experiments on the national ignition facility

This report details the analyses and related uncertainties in measuring longitudinal-stress–density paths in indirect laser-driven ramp equation-of-state (EOS) experiments. Experiments were conducted at the National Ignition Facility (NIF) located at the Lawrence Livermore National Laboratory. The NIF can deliver up to 2 MJ of laser energy over 30 ns and provide the necessary laser power and control to ramp compress materials to TPa pressures (1 TPa = 10 × 10 6 atmospheres). These data provide low-temperature solid-state EOS data relevant to the extreme conditions found in the deep interiors of giant planets. In these experiments, multi-stepped samples with thicknesses in the range of 40–120 µm experience an initial shock compression followed by a time-dependent ramp compression to peak pressure. Interface velocity measurements from each thickness combine to place a constraint on the Lagrangian sound speed as a function of particle velocity, which in turn allows for the determination of a continuous stress–density path to high levels of compressibility. In this report, we present a detailed description of the experimental techniques and measurement uncertainties and describe how these uncertainties combine to place a final uncertainty in both stress and density. Here, we address the effects of time-dependent deformation and the sensitivity of ramp EOS techniques to the onset of phase transformations.

47 OTHER INSTRUMENTATION↗