Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Pressure transfer function of a JT15D nozzle due to acoustic and convected entropy fluctuations

An acoustic transmission matrix analysis of sound propagation in a variable area duct with and without flow is extended to include convected entropy fluctuations. The boundary conditions used in the analysis are a transfer function relating entropy and pressure at the nozzle inlet and the nozzle exit impedance. The nozzle pressure transfer function calculated is compared with JT15D turbofan engine nozzle data. The one dimensional theory for sound propagation in a variable area nozzle with flow but without convected entropy is good at the low engine speeds where the nozzle exit Mach number is low (M=0.2) and the duct exit impedance model is good. The effect of convected entropy appears to be so negligible that it is obscured by the inaccuracy of the nozzle exit impedance model, the lack of information on the magnitude of the convected entropy and its phase relationship with the pressure, and the scatter in the data. An improved duct exit impedance model is required at the higher engine speeds where the nozzle exit Mach number is high (M=0.56) and at low frequencies (below 120 Hz).

Miles, J. H.↗

The ground vortex flow field associated with a jet in a cross flow impinging on a ground plane for uniform and annular turbulent axisymmetric jets

An experimental study was conducted of the impingement of a single circular jet on a ground plane in a cross flow. This geometry is a simplified model of the interaction of propulsive jet exhaust from a V/STOL aircraft with the ground in forward flight. Jets were oriented normal to the cross flow and ground plane. Jet size, cross flow-to-jet velocity ratio, ground plane-to-jet board spacing, and jet exit turbulence level and mean velocity profile shape were all varied to determine their effects on the size of the ground vortex interaction region which forms on the ground plane, using smoke injection into the jet. Three component laser Doppler velocimeter measurements were made with a commercial three color system for the case of a uniform jet with exit spacing equal to 5.5 diameters and cross flow-to-jet velocity ratio equal to 0.11. The flow visualization data compared well for equivalent runs of the same nondimensional jet exit spacing and the same velocity ratio for different diameter nozzles, except at very low velocity ratios and for the larger nozzle, where tunnel blockage became significant. Variation of observed ground vortex size with cross flow-to-jet velocity ratio was consistent with previous studies. Observed effects of jet size and ground plane-to-jet board spacing were relatively small. Jet exit turbulence level effects were also small. However, an annular jet with a low velocity central core was found to have a significantly smaller ground vortex than an equivalent uniform jet at the same values of cross flow-to-jet velocity ratio and jet exit-to-ground plane spacing. This may suggest a means of altering ground vortex behavior somewhat, and points out the importance of proper simulation of jet exit velocity conditions. LV data indicated unsteady turbulence levels in the ground vortex in excess of 70 percent.

Cavage, William M.↗

Phase 2: HGM air flow tests in support of HEX vane investigation

Following the start of SSME certification testing for the Pratt and Whitney Alternate Turbopump Development (ATD) High Pressure Oxidizer Turbopump (HPOTP), cracking of the leading edge of the inner HEX vane was experienced. The HEX vane, at the inlet of the oxidizer bowl in the Hot Gas Manifold (HGM), accepts the HPOTP turbine discharge flow and turns it toward the Gaseous Oxidizer Heat Exchanger (GOX HEX) coil. The cracking consistently initiated over a specific circumferential region of the hex vane, with other circumferential locations appearing with increased run time. Since cracking had not to date been seen with the baseline HPOTP, a fluid-structural interaction involving the ATD HPOTP turbine exit flowfield and the HEX inner vane was suspected. As part of NASA contract NAS8-36801, Pratt and Whitney conducted air flow tests of the ATD HPOTP turbine turnaround duct flowpath in the MSFC Phase 2 HGM air flow model. These tests included HEX vane strain gages and additional fluctuating pressure gages in the turnaround duct and HEX vane flowpath area. Three-dimensional flow probe measurements at two stations downstream of the turbine simulator exit plane were also made. Modifications to the HPOTP turbine simulator investigated the effects on turbine exit flow profile and velocity components, with the objective of reproducing flow conditions calculated for the actual ATD HPOTP hardware. Testing was done at the MSFC SSME Dynamic Fluid Air Flow (Dual-Leg) Facility, at air supply pressures between 50 and 250 psia. Combinations of turbine exit Mach number and pressure level were run to investigate the effect of flow regime. Information presented includes: (1) Descriptions of turbine simulator modifications to produce the desired flow environment; (2) Types and locations for instrumentation added to the flow model for improved diagnostic capability; (3) Evaluation of the effect of changes to the turbine simulator flowpath on the turbine exit flow environment; and (4) Comparison of the experimental turbine exit flow environment to the environment calculated for the ATD HPOTP.

Cox, G. B., Jr.↗

Fundamental Mixing and Combustion Experiments for Propelled Hypersonic Flight

The first experiment is a study of a coaxial jet discharging into stagnant laboratory air, with center jet of a mixture of 5% oxygen and 95% helium by volume and coflow jet of air. The exit flow pressure of both center-jet and coflow nozzles is 1 atmosphere. The presence of oxygen in the center jet is to allow the use of an oxygen flow-tagging technique (RELIEF4) to obtain non-intrusive velocity measurements. Both jets are nominally Mach 1.8, but, because of the greater speed of sound, the center jet velocity is more than twice that of the coflow. The mixing layer which forms between the center jet and the coflow near the nozzle exit is compressible, with a calculated convective Mach number of approximately 0.7. This geometry has several advantages: The streamwise development of the flow is generally dominated by turbulent stresses (rather than pressure forces), and thus calculations are sensitive to turbulence modeling. It includes features present in supersonic combustors, including a compressible mixing layer near the nozzle exit and a light-gas/air plume downstream. Since it is a free jet, it provides easy access for both optical instrumentation and probes. Since it is axisymmetric, it requires fewer experimental measurements to fully characterize, and calculations can be performed with more modest computer resources. However, weak shock waves formed at the nozzle exit strengthen and turn normal as they approach the axis, complicating the flow. Care is thus taken in the design of the facility to provide as near as possible to 1-D flow at the exit of both center and coflow nozzles, and to minimize the strength of waves generated at the nozzle exit. Results from this experiment are compared to CFD solutions obtained by VULCAN, a previously developed code used in engine analysis. The second experiment is a study of a supersonic combustor consisting of a diverging duct with single downstream-angled wall injector. Thus, the geometry is relatively simple and large regions of subsonic recirculating flow are avoided. The nominal entrance Mach number is 2 and the enthalpy of the test gas (hot air "simulant") is nominally that of Mach 7 flight. It was believed, on the basis of calculations performed that this would produce mixing-limited flow, that is to say, one for which chemical reaction to equilibrium proceeds at a much greater rate than mixing. It later proved that this was not the case. The primary experimental technique employed is coherent anti-Stokes Raman spectroscopy, known by its acronym CARS. The species probed is molecular nitrogen and the quantity measured is temperature. Intrusive probes, such as Pitot, total temperature, hot-wire, etc., are not used due to access difficulty and high heat flux in the combustor, and because they may alter the flow. CARS has several advantages over other optical methods. It is a relatively mature and well-understood technique. Signal levels are relatively high and the signal is in the form of a coherent (laser) beam that can be collected through small windows. Incoherent (non-CARS) interferences are rejected by spatial filtering.

Diskin, G. S.↗

Design of a Mach-3 Nozzle for TBCC Testing in the NASA LaRC 8-ft High Temperature Tunnel

A new nozzle is being constructed for the NASA Langley Research Center 8-Foot High Temperature Tunnel. The axisymmetric nozzle was designed with a Mach-3 exit flow for testing Turbine-Based Combined-Cycle engines at a Mach number in the vicinity of the transition from turbojet to ramjet operation. The nozzle contour was designed using the NASA Langley IMOCND computer program which solves the potential equation using the classical method of characteristics. To include viscous effects, the design procedure iterated the MOC contour generation with CFD Navier-Stokes calculations, adjusting MOC input parameters until target nozzle-exit conditions were achieved in the Navier-Stokes calculations. The design process was complicated by a requirement to use the final 29.5 inches of an existing 54.5-inch exit-diameter Mach-5 nozzle contour. This was accomplished by generating a Mach-3 contour that matched the radius of the Mach-5 contour at the match point and using a 3rd order polynomial to create a smooth transition between the two contours. During the final evaluation of the design it was realized that the throat diameter is more than half that of the upstream mixing chamber. This led to the concern that large vortical structures generated in the mixer would persist downstream, affecting nozzle-exit flow. This concern was addressed by analyzing the results of three-dimensional, viscous, numerical simulations of the entire flowfield, from the exit of the facility combustor to the nozzle exit. An analysis of the solution indicated that large scale structures do not pass through the throat and that both the total temperature and species (CO2) are well mixed in the mixer, providing uniform flow to the nozzle and subsequently the test cabin.

Gaffney, Richard L., Jr.↗

Angled slit design for computed tomographic imaging of electron beams

Computed tomographic method and apparatus includes an electron or ion beam having a beam axis, a refractory metal disk; at least one slit in the refractory metal disk that receive the beam, wherein the slit is at an angle to the beam axis; a beam entrance opening in the slit that allows the beam to enter; an effective beam exit opening in the slit that allow the beam to exit, wherein the beam effective exit opening is smaller than the beam entrance opening; and a system for moving the beam across the refractory metal disk, wherein the beam enters the slit through the beam entrance opening and exits the slit through the effective beam exit opening; and a computed tomographic device for measuring the beam that enters and exits the slit for analyzing the beam.

Elmer, John W.↗

End-of-Mission Planning Challenges for a Satellite in a Constellation

At the end of a mission, satellites embedded in a constellation must first perform propulsive maneuvers to safely exit the constellation before they can begin with the usual end-of-mission activities: deorbit, passivation, and decommissioning. The target orbit for these exit maneuvers must be sufficiently below the remaining constellation satellites such that, once achieved, there is no longer risk of close conjunctions. Yet, the exit maneuvers must be done based on the spacecraft's state of health and operational capability when the decision to end the mission is made. This paper focuses on the recently developed exit strategy for the CloudSat mission to highlight problems and issues, which forced the discarding of CloudSat's original EoM Plan and its replacement with a new plan consistent with changes to the spacecraft's original operational mode. The analyses behind and decisions made in formulating this new exit strategy will be of interest to other missions in a constellation currently preparing to update their End-of-Mission Plan.

CloudSat↗

Effect of Dimensional Changes on Plasma Characteristics in Electrothermal Capillary Discharges for Optimized Performance in Fusion Pellet Injection

Geometrical changes in capillary discharges influence the plasma properties and can control exit parameters to certain desired values. For a fixed capillary radius of 2 mm and a 72-μs 43.9-kA peak discharge current, the plasma temperature is about 2.7 eV for different capillary lengths due to the constant input energy, while the number densities tend to saturate for capillary lengths greater than 12 cm. The electrical conductivity reaches 4.02 × 104 Ω{sup −1} m{sup −1} and then tends to saturate for 9-cm capillary length. The maximum bulk velocity at the capillary exit slightly increases with the increase in the capillary length from 6.15 to 6.26 km/s for lengths below 18 cm and decreases to 5.88 km/s for longer capillaries due to the higher amount of ablated mass and increased drag forces. For a 9-cm length with the same 72-μs 43.9-kA peak discharge current, the increase in the capillary radius reduces the energy density, which in turn reduces the total ablate mass, plasma density, electrical conductivity, and exit pressure. It is shown that the plasma temperature decreases from 4.6 to 2.1 eV by increasing the capillary radius and radiant heat flux also drops from 463 to 18.1 GW/m{sup 2}. The exit bulk velocity drops from 8.7 to 5.3 km/s as the radius increases from 0.5 to 3.6 mm, respectively. The design features of a capillary discharge can be adjusted for the radius and length, to produce specific plasma parameters for desired applications. Scaling laws relating exit peak plasma parameters to radius and length are obtained to facilitate quick estimate of plasma parameters. The validation of this model has been confirmed by confronting with experimental measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Outflow Boundary Conditions for Turbine-Integrated Rotating Detonation Combustors

This study examines outflow boundary conditions (BCs) in computational fluid dynamics (CFD) simulations of a transition duct with and without guide vanes that converts supersonic flow exiting a rotating detonation combustor (RDC) to subsonic flow to drive a turbine. Since the flow exiting the transition duct has swirling shock waves with significant spatial and temporal variations in pressure, temperature, and Mach number, imposing proper BCs poses a challenge. To ensure all swirling shock waves exit the transition duct without creating non-physical reflected waves at its outlet, this study examined three outflow BCs: (1) the average pressure imposed at the duct’s outlet, (2) a nonreflecting BC (NRBC) with a specified average pressure imposed at the duct’s outlet, (3) the average pressure imposed at the outlet of an extension duct made up of a buffer layer and a sponge layer. This study is based on the three-dimensional, unsteady density-weighted-ensemble-averaged continuity, Navier–Stokes, and energy equations for a thermally perfect gas closed by the realizable k–ε model and “enhanced” wall functions. The results obtained show that imposing an average pressure at the transition duct’s outlet produces spurious waves that degrade the physical meaningfulness of the solution. When the NRBC was applied, swirling shock waves exited the duct’s outlet without creating spurious waves. However, its usage requires the gas to be thermally, as well as calorically, perfect, which this study shows could be a concern. By imposing the average pressure at the outlet of an extension duct, the gas does not need to be calorically perfect. The results obtained show the effects of the sponge layer’s length and coarsening ratio on damping nonuniformities in non-physical reflected waves to ensure the flow exiting the transition duct’s outlet can do so as if there are no boundaries present and has the desired average pressure—even though the BC is applied at the extension duct’s outlet.

gas turbines↗

Analytical correlation of centrifugal compressor design geometry for maximum efficiency with specific speed

Centrifugal compressor performance was examined analytically to determine optimum geometry for various applications as characterized by specific speed. Seven specific losses were calculated for various combinations of inlet tip-exit diameter ratio, inlet hub-tip diameter ratio, blade exit backsweep, and inlet-tip absolute tangential velocity for solid body prewhirl. The losses considered were inlet guide vane loss, blade loading loss, skin friction loss, recirculation loss, disk friction loss, vaneless diffuser loss, and vaned diffuser loss. Maximum total efficiencies ranged from 0.497 to 0.868 for a specific speed range of 0.257 to 1.346. Curves of rotor exit absolute flow angle, inlet tip-exit diameter ratio, inlet hub-tip diameter ratio, head coefficient and blade exit backsweep are presented over a range of specific speeds for various inducer tip speeds to permit rapid selection of optimum compressor size and shape for a variety of applications.

Galvas, M. R.↗

Evaluation of an experimental short-length annular combustor: One-side-entry dilution airflow concept

A test program was conducted to evaluate an experimental short-length annular combustor that uses a one-side-entry dilution airflow concept. The combustor design features scoops on the outer liner for controlling the primary- and secondary-zone airflow distribution. Combustor inlet total pressures were limited to 62 N/sq cm (90 psia) with inlet-air temperatures from 590 K (600 F) to 890 K (1150 F). At a diffuser inlet Mach number of 0.25, the exit temperature pattern factor was 0.44 with an average exit temperature of 1436 K (2124 F) and a total pressure loss of 4.3 percent. At a diffuser inlet Mach number of 0.31, the exit temperature pattern factor was reduced to 0.29 with an average exit temperature of 1450 K (2151 F) and a total pressure loss of 6.1 percent. Nominal combustion efficiencies of 100 percent were obtained with the ASTM A-1 fuel. Exhaust gas emissions, smoke, and altitude relight data are included with exit-temperature profiles and distribution patterns.

Humenik, F. M.↗

Laser Doppler systems in pollution monitoring

The paper reports on a program undertaken to determine the feasibility of using a laser Doppler velocimeter (LDV) to measure smoke-stack gas exit velocity, particulate concentration, and mass flow. Measurements made with a CO2 laser Doppler radar system at a coal-burning power plant are compared with in-stack measurements made by a pitot tube. The operational principles of a LDV are briefly described along with the system employed in the present study. Data discussed include typical Doppler spectra from smoke-stack effluents at various laser elevation angles, the measured velocity profile across the stack exit, and the LDV-measured exit velocity as a function of the exit velocity measured by the in-stack instrument. The in-stack velocity is found to be about 14% higher than the LDV velocity, but this discrepancy is regarded as a systematic error. In general, linear relationships are observed between the laser data, the exit velocity, and the particulate concentration. It is concluded that an LDV has the capability of determining both the mass concentration and the mass flow from a power-plant smoke stack.

Miller, C. R.↗

Computational analysis and preliminary redesign of the nozzle contour of the Langley hypersonic CF4 tunnel

A computational analysis, modification, and preliminary redesign study was performed on the nozzle contour of the Langley Hypersonic CF4 Tunnel. This study showed that the existing nozzle was contoured incorrectly for the design operating condition, and this error was shown to produce the measured disturbances in the exit flow field. A modified contour was designed for the current nozzle downstream of the maximum turning point that would provide a uniform exit flow. New nozzle contours were also designed for an exit Mach number and Reynolds number combination which matches that attainable in the Langley 20-Inch Mach 6 Tunnel. Two nozzle contours were designed: one having the same exit radius but a larger mass flow rate than that of the existing CF4 Tunnel, and the other having the same mass flow rate but a smaller exit radius than that of the existing CF4 Tunnel.

Thompson, R. A.↗

Enhanced mixing of an axisymmetric jet by aerodynamic excitation

The main objective of acoustic excitation studies is to gain a high level of control over processes governing free shear flow characteristics. The basic premise is that inherent instability waves in free shear flows are excitable by external perturbations with frequencies close to the natural instability frequency of the flow. An 8.89 cm diameter axisymmetric jet was acoustically excited by four loudspeakers placed upstream of the nozzle exit. Measurements were made at Mach numbers of 0.435 and 0.2. A single hot-wire probe was used to obtain turbulence levels at the nozzle exit and along the centerline, and a microphone at the nozzle exit was used to study the resonance characteristics of the rig. A Pitot probe was stationed at X/D = 9 downstream along the nozzle axis to study the Strouhal number dependence and to look at threshold levels for excitation. The test results were obtained after a preliminary evaluation and facility improvement. Excitation at the correct Strouhal number enhanced mixing significantly. The effects were most prominent in the Strouhal number range between 0.4 and 1.0. The effects of acoustic excitation also depend considerably on the sound pressure level at the nozzle exit and were more pronounced at higher sound levels. Other factors which influenced the excitability were valve noise, exit turbulence levels, extraneous noise, and a flanged nozzle. Analysis of the hot-wire signal, in conditions of optimum jet mixing, showed vortex pairing to occur between 2 and 3 diameters downstream.

Raman, Ganesh↗

An analysis of the viscous flow through a compact radial turbine by the average passage approach

A steady, three-dimensional viscous average passage computer code is used to analyze the flow through a compact radial turbine rotor. The code models the flow as spatially periodic from blade passage to blade passage. Results from the code using varying computational models are compared with each other and with experimental data. These results include blade surface velocities and pressures, exit vorticity and entropy contour plots, shroud pressures, and spanwise exit total temperature, total pressure, and swirl distributions. The three computational models used are inviscid, viscous with no blade clearance, and viscous with blade clearance. It is found that modeling viscous effects improves correlation with experimental data, while modeling hub and tip clearances further improves some comparisons. Experimental results such as a local maximum of exit swirl, reduced exit total pressures at the walls, and exit total temperature magnitudes are explained by interpretation of the flow physics and computed secondary flows. Trends in the computed blade loading diagrams are similarly explained.

Heidmann, James D.↗

Evaluation of water cooled supersonic temperature and pressure probes for application to 2000 F flows

The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.

Lagen, Nicholas T.↗

An analysis of the viscous flow through a compact radial turbine by the average passage approach

A steady, three-dimensional viscous average passage computer code is used to analyze the flow through a compact radial turbine rotor. The code models the flow as spatially periodic from blade passage to blade passage. Results from the code using varying computational models are compared with each other and with experimental data. These results include blade surface velocities and pressures, exit vorticity and entropy contour plots, shroud pressures, and spanwise exit total temperature, total pressure, and swirl distributions. The three computational models used are inviscid, viscous with no blade clearance, and viscous with blade clearance. It is found that modeling viscous effects improves correlation with experimental data, while modeling hub and tip clearances further improves some comparisons. Experimental results such as a local maximum of exit swirl, reduced exit total pressures at the walls, and exit total temperature magnitudes are explained by interpretation of the flow physics and computed secondary flows. Trends in the computed blade loading diagrams are similarly explained.

Heidmann, James D.↗

Measurement and analysis of a small nozzle plume in vacuum

Measurements of Pitot pressure and flow angle were made in the plume of a nozzle flowing nitrogen and exhausting to a vacuum. The measurements were compared to results from a numerical simulation of the flow that was based on kinetic theory and used the direct-simulation Monte Carlo (DSMC) method. Numerical results were compared with measurements made in the plume at various axial and radial stations. Total pressure measurements were made with Pitot tubes sized for specific regions of the plume. Flow angle measurements were made with a conical probe. The measurement area for flow angle extended to 160 mm (5 exit diameters) downstream of the nozzle exit plane and radially to 60 mm (1.9 exit diameters) from the plume axis. The total pressure measurements extended 480 mm (16 exit diameters) downstream and radially to 60 mm. Comparisons of computed results from the DSMC method with measurements of flow angle displayed improved agreement with increasing distance from the exit plane. Pitot pressures computed from the DSMC method were in reasonably good agreement with experimental results over the entire measurement area.

Penko, Paul F.↗