Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EVAPORATION RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Precipitation recycling in the Amazon basin

Precipitation recycling is the contribution of evaporation within a region to precipitation in that same region. The recycling rate is a diagnostic measure of the potential for interactions between land surface hydrology and regional climate. In this paper we present a model for describing the seasonal and spatial variability of the recycling process. The precipitation recycling ratio, rho, is the basic variable in describing the recycling process. Rho is the fraction of precipitation at a certain location and time which is contributed by evaporation within the region under study. The recycling model is applied in studyiing the hydrologic cycle in the Amazon basin. It is estimated that about 25% of all the rain that falls in the Amazon basin is contributed by evaporation within the basin. This estimate is based on analysis of a data set supplied by the European Centre for Medium-range Weather Forecasts (ECMWF). The same analysis is repeated using a different data set from the Geophysical Fluid Dynamics Laboratory (GFDL). Based on this data set, the recycling ratio is estimated to be 35%. The seasonal variability of the recycling ratio is small compared with the yearly average. The new estimates of the recycling ratio are compared with results of previous studies, and the differences are explained.

Eltahir, E. A. B.↗

Flare loop radiative hydrodynamics. IV - Dynamic evolution of unstable semiempirical loop models

The evolution of the unstable solar atmosphere into the nonlinear phase, in response to various perturbations, is followed. The initial dynamic evolution of the atmosphere follows the predictions of linear stability analysis. In the nonlinear phase, rapid changes are confined to the transition region; these changes are manifested as a propagation of the transition region through the plasma, i.e., chromospheric evaporation or condensation. Global evolution therefore proceeds on the coronal conductive time scale. The rate of propagation of the transition region is determined by the imbalance between the energy supplied by thermal conduction from the corona and radiative cooling within the transition region itself. Flow velocities in the lower corona during evaporation or condensation are, in the cases studied, of order 3 km/s. The observed dynamic evolution is consistent with the existence of relatively long-lived coronal loops whose brightnesses vary on the evaporative time scale.

An, C.-H.↗

Evaluation of Thermolytic Hydrogen Generation Rate Models at High-Temperature/High-Hydroxide Regimes

This report describes the results of testing performed to extend the applicable ranges of temperature and hydroxide concentration for use within the Glycolate and Global Total Organic Carbon (TOC) Hydrogen Generation Rate (HGR) expressions. Seven experimental conditions (six simulants of the 242-25H Evaporator system chosen as a D-optimal set of experiments and a single test conducted at an elevated boiling point of 170 °C) were investigated in the presence of sodium glycolate and Xiameter TM AFE-1010. Glycolate was employed to study the extension of the Glycolate Thermolytic HGR expression while Xiameter TM AFE-1010 was employed to study the extension of the Global TOC Thermolytic HGR expression. The following conclusions were derived from this testing: The Glycolate Thermolytic HGR expression may be confidently used to predict thermolytic HGRs from glycolate at temperatures as high as 170 °C and hydroxide concentrations as high as 23 M.; The hydroxide and temperature-dependence predicted by the Global TOC Thermolytic HGR expression has been confirmed at temperatures as high as 170 °C and hydroxide concentrations as high as 23 M, suggesting that the Global TOC Thermolytic HGR expression may be used at these ranges.; Methane was observed from tests with Xiameter TM AFE-1010 at production rates higher than those observed for hydrogen. These rates were observed at temperatures higher than 100 °C.; Preliminary models suggest that increasing hydroxide/temperature causes an increase in Methane Generation Rate (MGR) from Xiameter TM AFE-1010. The following recommendations are based on this testing: The existing equations for thermolytic HGR from glycolate and non-glycolate organics should be used at Concentration, Storage, and Transfer Facilities (CSTF) storage and evaporation conditions, including temperatures and hydroxide concentrations exhibited in the 242-25H Evaporator.; Further investigation should be made into the influence of methylsilanes on CSTF flammability. This investigation should include: determination of the types of methylsilanes historically added to the CSTF, determination of methane formation rates from each type of methylsilane, and determination of the extent of degradation of methylsilanes in CSTF waste.; Characterization techniques should be developed by Savannah River National Laboratory (SRNL) to assist in the speciation of methylsilane-containing waste in the CSTF.; Additional testing with radioactive waste should be performed to determine the MGRs possible in radioactive waste and better inform model predictions made from testing with simulants.

08 HYDROGEN↗

Seasonal and Interannual Variations of Evaporation and their Relations with Precipitation, Net Radiation, and Net Carbon Accumulation for the Gediz Basin Area

A model combining the rate of carbon assimilation with water and energy balance equations has been run using satellite and ancillary data for a period of 60 months (January 1986 to December 1990). Calculations for the Gediz basin area give mean annual evaporation as 395 mm, which is composed of 45% transpiration, 42% soil evaporation and 13% interception. The coefficient of interannual variation of evaporation is found to be 6%, while that for precipitation and net radiation are, respectively, 16% and 2%, illustrating that net radiation has an important effect in modulating interannual variation of evaporation. The mean annual water use efficiency (i.e., the ratio of net carbon accumulation and total evaporation) is ca. 1 g/sq m/mm, and has a coefficient of interannual variation of 5%. A comparison of the mean water use efficiency with field observations suggests that evaporation over the area is utilized well for biomass production. The reference crop evaporation for irrigated areas has annual mean and coefficient of variation as, respectively, 1176 mm and 3%. The total evaporation during three summer months of peak evaporation (June-August) is estimated to be about 575 mm for irrigated crops like maize and cotton. Seasonal variations of the fluxes are presented.

Choudhury, Bhaskar J.↗

Evaluation of a locally homogeneous model of spray evaporation

A model of spray evaporation which employs a second-order turbulence model in conjunction with the locally homogeneous flow approximation, which implies infinitely fast interphase transport rates is presented. Measurements to test the model were completed for single phase constant and variable density jets, as well as an evaporating spray in stagnant air. Profiles of mean velocity, composition, temperature and drop size distribution as well as velocity fluctuations and Reynolds stress, were measured within the spray. Predictions were in agreement with measurements in single phase flows and also with many characteristics of the spray, e.g. flow width, radial profiles of mean and turbulent quantities, and the axial rate of decay of mean velocity and mixture fraction.

Shearer, A. J.↗

Determination of the 60 Zn level density from neutron evaporation spectra

Nuclear reactions of interest for astrophysics and applications often rely on statistical model calculations for nuclear reaction rates, particularly for nuclei far from β stability. However, statistical model parameters are often poorly constrained, where experimental constraints are particularly sparse for exotic nuclides. For example, our understanding of the breakout from the NiCu cycle in the astrophysical rp-process is currently limited by uncertainties in the statistical properties of the proton-rich nucleus 60 Zn. We have determined the nuclear level density of 60 Zn using neutron evaporation spectra from 58 Ni( 3 He,n) measured at the Edwards Accelerator Laboratory. We compare our results to a number of theoretical predictions, including phenomenological, microscopic, and shell-model-based approaches. Notably, we find the 60 Zn level density is somewhat lower than expected for excitation energies populated in the 59 Cu(p,γ) 60 Zn reaction under rp-process conditions. This includes a level density plateau from roughly 5 to 6 MeV excitation energy, which is counter to the usual expectation of exponential growth and all theoretical predictions that we explore. Here, a determination of the spin distribution at the relevant excitation energies in 60 Zn is needed to confirm that the Hauser-Feshbach formalism is appropriate for the 59 Cu(p,γ) 60 Zn reaction rate at x-ray burst temperatures

59 ≤ A ≤ 89↗

Modeling the use of a binary mixture as a control scheme for two-phase thermal systems

Two-phase thermal loops using mechanical pumps, capillary pumps, or a combination of the two have been chosen as the main heat transfer systems for the space station. For these systems to operate optimally, the flow rate in the loop should be controlled in response to the vapor/liquid ratio leaving the evaporator. By substituting a mixture of two non-azeotropic fluids in place of the single fluid normally used in these systems, it may be possible to monitor the temperature of the exiting vapor and determine the vapor/liquid ratio. The flow rate would then be adjusted to maximize the load capability with minimum energy input. A FLUINT model was developed to study the system dynamics of a hybrid capillary pumped loop using this type of control and was found to be stable under all the test conditions.

Benner, S. M.↗

Effect of Metal Halides Treatment on High Throughput Low Temperature CIGS Solar Cells

Copper indium gallium diselenide (CIGS) semiconductor thin films were deposited at high rate and low temperature using single-stage thermal co-evaporation process on molybdenum back contact. A post deposition treatment was done by flashing AgBr at 350 ºC to induce recrystallization. Changes in morphology were confirmed by SEM, with an observed increase in grain size, as well as by XRD measurements, with a decrease in FWHM. Device results show an improvement of the performance after the AgBr vapor treatment, as all the photovoltaic parameters enhanced. Altogether, AgBr seems to be a suitable transport agent and beneficial for device fabrication.

14 SOLAR ENERGY↗

Refueling Infrastructure Scoping and Feasibility Assessment for Hydrogen Rail Applications

The feasibility and component cost of hydrogen rail refueling infrastructure is examined. Example reference stations can inform future studies on components and systems specifically for hydrogen rail refueling facilities. All of the 5 designs considered assumed the bulk storage of liquid hydrogen on-site, from which either gaseous or liquid hydrogen would be dispensed. The first design was estimated to refuel 10 multiple unit trains per day, each train containing 260 kg of gaseous hydrogen at 350 bar on-board. The second base design targeted the refueling of 50 passenger locomotives, each with 400 kg of gaseous hydrogen on-board at 350 bar. Variations from this basic design were made to consider the effect of two different filling times, two different hydrogen compression methods, and two different station design approaches. For each design variation, components were sized, approximate costs were estimated for major components, and physical layouts were created. For both gaseous hydrogen-dispensing base designs, the design of direct-fill using a cryopump design was the lowest cost due to the high cost of the cascade storage system and gas compressor. The last three base designs all assumed that liquid hydrogen was dispensed into tender cars for freight locomotives that required 7,500 kg of liquid hydrogen, and the three different designs assumed that 5, 50, or 200 tender cars were refueled every day. The total component costs are very different for each design, because each design has a very different dispensing capacity. The total component cost for these three designs are driven by the cost of the liquid hydrogen tank; additionally, delivering that much liquid hydrogen to the refueling facility may not be practical. Many of the designs needed the use of multiple evaporators, compressors, and cryopumps operating in parallel to meet required flow rates. In the future, the components identified here can be improved and scaled-up to better fit the needs of heavy-duty refueling facilities. This study provides basic feasibility and first-order design guidance for hydrogen refueling facilities serving emerging rail applications.

08 HYDROGEN↗

Review of critical flow rate, propagation of pressure pulse, and sonic velocity in two-phase media

For single-phase media, the critical discharge velocity, the sonic velocity, and the pressure pulse propagation velocity can be expressed in the same form by assuming isentropic, equilibria processes. In two-phase mixtures, the same concept is not valid due to the existence of interfacial transports of momentum, heat, and mass. Thus, the three velocities should be treated differently and separately for each particular condition, taking into account the various transport processes involved under that condition. Various attempts are reviewed to predict the critical discharge rate or the propagation velocities by considering slip ratio (momentum change), evaporation (mass and heat transport), flow pattern, etc. Experimental data were compared with predictions based on various theorems. The importance is stressed of the time required to achieve equilibrium as compared with the time available during the process, for example, of passing a pressure pulse.

Hsu, Y.↗

The effects of surface evaporation parameterizations on climate sensitivity to solar constant variations

The effects of two different evaporation parameterizations on the sensitivity of simulated climate to solar constant variations are investigated by using a zonally averaged climate model. One parameterization is a nonlinear formulation in which the evaporation is nonlinearly proportional to the sensible heat flux, with the Bowen ratio determined by the predicted vertical temperature and humidity gradients near the earth's surface (model A). The other is the formulation of Saltzman (1968) with the evaporation linearly proportional to the sensible heat flux (model B). The computed climates of models A and B are in good agreement except for the energy partition between sensible and latent heat at the earth's surface. The difference in evaporation parameterizations causes a difference in the response of temperature lapse rate to solar constant variations and a difference in the sensitivity of longwave radiation to surface temperature which leads to a smaller sensitivity of surface temperature to solar constant variations in model A than in model B. The results of model A are qualitatively in agreement with those of the general circulation model calculations of Wetherald and Manabe (1975).

Chou, S.-H.↗

Current Status on the use of Parallel Computing in Turbulent Reacting Flow Computations Involving Sprays, Monte Carlo PDF and Unstructured Grids

The state of the art in multidimensional combustor modeling as evidenced by the level of sophistication employed in terms of modeling and numerical accuracy considerations, is also dictated by the available computer memory and turnaround times afforded by present-day computers. With the aim of advancing the current multi-dimensional computational tools used in the design of advanced technology combustors, a solution procedure is developed that combines the novelty of the coupled CFD/spray/scalar Monte Carlo PDF (Probability Density Function) computations on unstructured grids with the ability to run on parallel architectures. In this approach, the mean gas-phase velocity and turbulence fields are determined from a standard turbulence model, the joint composition of species and enthalpy from the solution of a modeled PDF transport equation, and a Lagrangian-based dilute spray model is used for the liquid-phase representation. The gas-turbine combustor flows are often characterized by a complex interaction between various physical processes associated with the interaction between the liquid and gas phases, droplet vaporization, turbulent mixing, heat release associated with chemical kinetics, radiative heat transfer associated with highly absorbing and radiating species, among others. The rate controlling processes often interact with each other at various disparate time 1 and length scales. In particular, turbulence plays an important role in determining the rates of mass and heat transfer, chemical reactions, and liquid phase evaporation in many practical combustion devices.

Raju, M. S.↗

Response of deep and shallow tropical maritime cumuli to large-scale processes

The bulk diagnostic method of Yanai et al. (1973) and a simplified version of the spectral diagnostic method of Nitta (1975) are used for a more quantitative evaluation of the response of various types of cumuliform clouds to large-scale processes, using the same data set in the Marshall Islands area for a 100-day period in 1956. The dependence of the cloud mass flux distribution on radiative cooling, large-scale vertical motion, and evaporation from the sea is examined. It is shown that typical radiative cooling rates in the tropics tend to produce a bimodal distribution of mass spectrum exhibiting deep and shallow clouds. The bimodal distribution is further enhanced when the large-scale vertical motion is upward, and a nearly unimodal distribution of shallow clouds prevails when the relative cooling is compensated by the heating due to the large-scale subsidence. Both deep and shallow clouds are modulated by large-scale disturbances. The primary role of surface evaporation is to maintain the moisture flux at the cloud base.

Yanai, M.↗

Chromospheric Evaporation and Decimetric Radio Emission in Solar Flares

We have discovered decimetric signatures of the chromospheric evaporation process. Evidence for the radio detection of chromospheric evaporation is based on the radio-inferred values of (1) the electron density, (2) the propagation speed, and (3) the timing, which are found to be in good agreement with statistical values inferred from the blueshifted Ca xix soft X-ray line. The physical basis of our model is that free-free absorption of plasma emission is strongly modified by the steep density gradient and the large temperature increase in the upflowing flare plasma. The steplike density increase at the chromospheric evaporation front causes a local discontinuity in the plasma frequency, manifested as almost infinite drift rate in decimetric type III bursts. The large temperature increase of the upflowing plasma considerably reduces the local free-free opacity (due to the T-(exp -3/2) dependence) and thus enhances the brightness of radio bursts emitted at the local plasma frequency near the chromospheric evaporation front, while a high-frequency cutoff is expected in the high-density regions behind the front, which can be used to infer the velocity of the upflowing plasma. From model calculations we find strong evidence that decimetric bursts with a slowly drifting high-frequency cutoff are produced by fundamental plasma emission, contrary to the widespread belief that decimetric bursts are preferentially emitted at the harmonic plasma level. We analyzed 21 flare episodes from 1991-1993 for which broadband (100-3000 MHz) radio dynamic spectra from Phoenix, hard X-ray data from BATSE/CGRO, and soft X-ray data from GOES were available. We detected slowly drifting high-frequency cutoffs between 1.1 and 3.0 GHz, with drift rates of -41 +/- 32 MHz/s, extending over time intervals of 24 +/- 23 s. Developing a density model for type III-emitting flare loops based on the statistically observed drift rate of type III bursts by Alvarez & Haddock, we infer velocities of up to 360 km/s for the upflowing plasma, with an average of v(sub CE) = 236 +/- 130 km /s for episodes with 5-15 s duration. The mean electron density of the upflowing plasma is n(sub e) = 5.2(+/-3.1) x 10(exp 10) /cu cm when it is first detected in radio, at coronal altitudes of h(sub 0) = 9.2 +/- 2.3 Mm.

Aschwanden, Markus J.↗

Does the ocean-atmosphere system have more than one stable mode of operation?

The climate record obtained from two long Greenland ice cores reveals several brief climate oscillations during glacial time. The most recent of these oscillations, also found in continental pollen records, has greatest impact in the area under the meteorological influence of the northern Atlantic, but none in the United States. This suggests that these oscillations are caused by fluctuations in the formation rate of deep water in the northern Atlantic. As the present production of deep water in this area is driven by an excess of evaporation over precipitation and continental runoff, atmospheric water transport may be an important element in climate change. Changes in the production rate of deep water in this sector of the ocean may push the climate system from one quasi-stable mode of operation to another.

Broecker, W. S.↗

Investigation of VEGGIE Root Mat

VEGGIE is a plant growth facility that utilizes the phenomenon of capillary action as its primary watering system. A cloth made of Meta Aramid fiber, known as Nomex is used to wick water up from a reservoir to the bottom of the plants roots. This root mat system is intended to be low maintenance with no moving parts and requires minimal crew interface time. Unfortunately, the water wicking rates are inconsistent throughout the plant life cycle, thus causing plants to die. Over-wicking of water occurs toward the beginning of the cycle, while under-wicking occurs toward the middle. This inconsistency of wicking has become a major issue, drastically inhibiting plant growth. The primary objective is to determine the root cause of the inconsistent wicking through experimental testing. Suspect causes for the capillary water column to break include: a vacuum effect due to a negative pressure gradient in the water reservoir, contamination of material due to minerals in water and back wash from plant fertilizer, induced air bubbles while using syringe refill method, and material limitations of Nomex's ability to absorb and retain water. Experimental testing will be conducted to systematically determine the cause of under and over-wicking. Pressure gages will be used to determine pressure drop during the course of the plant life cycle and during the water refill process. A debubbler device will be connected to a root mat in order to equalize pressure inside the reservoir. Moisture and evaporation tests will simultaneously be implemented to observe moisture content and wicking rates over the course of a plant cycle. Water retention tests will be performed using strips of Nomex to determine materials wicking rates, porosity, and absorptivity. Through these experimental tests, we will have a better understanding of material properties of Nomex, as well as determine the root cause of water column breakage. With consistent test results, a forward plan can be achieved to resolve the issue and give valuable insight for the next generation of VEGGIE.

Subbiah, Arun M.↗

Reduction of the neutron imaginary potential off the stability line and its possible impact on neutron capture rates

The effect of the isovector imaginary optical potential has been studied experimentally by using the particle-evaporation technique for the 11 B + 48 Ca reaction with a 21.8 MeV 11 B beam. Spectra of neutron, proton, and α particles emitted from the neutron-rich compound nucleus 59 Mn have been measured and analyzed with traditional optical model potentials with their original parametrizations as well as with adjusted isovector imaginary components. It is shown that the isovector component of the imaginary potential is indispensable in the reproduction of proton and α-particle yields from this reaction and even needs to be enhanced compared with the suggestions of the original model parametrizations. Furthermore, this can lead to important consequences for astrophysical reaction-rate calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗