Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EVAPORATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Enhancing Electrophoretic Display Lifetime: Thiol-Polybutadiene Evaporation Barrier Property Response to Network Microstructure

An evaporation barrier is required to enhance the lifetime of electrophoretic deposition (EPD) displays. As EPD functions on the basis of reversible deposition and resuspension of colloids suspended in a solvent, evaporation of the solvent ultimately leads to device failure. Incorporation of a thiol-polybutadiene elastomer into EPD displays enabled display lifetime surpassing six months in counting and catalyzed rigid display transition into a flexible package. Final flexible display transition to mass production compels an electronic-ink approach to encapsulate display suspension within an elastomer shell. Final thiol-polybutadiene photosensitive resin network microstructure was idealized to be dense, homogeneous, and expose an elastic response to deformation. Research at hand details an approach to understanding microstructural change within display elastomers. Polybutadiene-based resin properties are modified via polymer chain structure, with and without added aromatic urethane methacrylate difunctionality, and in measuring network response to variation in thiol and initiator concentration. Dynamic mechanical analysis results signify that cross-linked segments within a difunctionalized polybutadiene network were on average eight times more elastically active than that of linked segments within a non-functionalized polybutadiene network. Difunctionalized polybutadiene samples also showed a 2.5 times greater maximum elastic modulus than non-functionalized samples. Hybrid polymer composed of both polybutadiene chains encompassed TE-2000 stiffness and B-1000 elasticity for use in encapsulating display suspension. Later experiments measured kinetic and rheological response due to alteration in dithiol cross-linker chain length via real time Fourier transform infrared spectroscopy and real-time dynamic rheology. Distinct differences were discovered between dithiol resin systems, as maximum thiol conversion achieved in short and long chain length dithiols was 86% and 11%, respectively. Oscillatory real-time rheological experiments confirmed a more uniform network to better dissipate applied shear in short chain length dithiol systems, as long chain length dithiols relayed a steep internal stress build-up due to less cross-links and chain entanglements. Thorough understanding of network formation aids the production of a stronger and impermeable elastomeric barrier for preservation of EPD displays.

36 MATERIALS SCIENCE↗

Analysis of the 2H-evaporator scale samples (HTF-17-56, -57)

Savannah River National Laboratory analyzed scale samples from both the wall and cone sections of the 242-16H Evaporator prior to chemical cleaning. The samples were analyzed for uranium and plutonium isotopes required for a Nuclear Criticality Safety Assessment of the scale removal process. The analysis of the scale samples found the material to contain crystalline nitrated cancrinite and clarkeite. Samples from both the wall and cone contain depleted uranium. Uranium concentrations of 16.8 wt% 4.76 wt% were measured in the wall and cone samples, respectively. The ratio of plutonium isotopes in both samples is ~85% Pu-239 and ~15% Pu-238 by mass and shows approximately the same 3.5 times higher concentration in the wall sample versus the cone sample as observed in the uranium concentrations. The mercury concentrations measured in the scale samples were higher than previously reported values. The wall sample contains 19.4 wt% mercury and the cone scale sample 11.4 wt% mercury. The results from the current scales samples show reasonable agreement with previous 242-16H Evaporator scale sample analysis; however, the uranium concentration in the current wall sample is substantially higher than previous measurements.

2H evaporator system↗

Feasibility Study – Using a Solar Evaporator to Reduce the Metalworking Fluid (MWF) Waste Stream

A solar evaporator was designed, built, and operated to reduce the water-based metalworking fluid waste stream. The evaporator was setup in Waste Management’s barrel lot inside one of the confinement areas. The unit processed three batches of waste fluid during the prototype testing. Initial tests removed 13% of the fluid waste stream. Subsequent modifications to the collector improved the rate to almost 20% per week. Evaluation of the risk during operation showed that even a small spill when associated with precipitation, and the unit placement within a confinement area, gave it the potential to contaminate more fluid that what it could save.

14 SOLAR ENERGY↗

Use of Air2Air Technology to Recover Fresh-Water from the Normal Evaporative Cooling Loss at Coal-Based Thermoelectric Power Plants

This program was undertaken to build and operate the first Air2Air{trademark} Water Conservation Cooling Tower at a power plant, giving a validated basis and capability for water conservation by this method. Air2Air{trademark} water conservation technology recovers a portion of the traditional cooling tower evaporate. The Condensing Module provides an air-to-air heat exchanger above the wet fill media, extracting the heat from the hot saturated moist air leaving in the cooling tower and condensing water. The rate of evaporate water recovery is typically 10%-25% annually, depending on the cooling tower location (climate).

01 COAL, LIGNITE, AND PEAT↗

THE USE OF DI WATER TO MITIGATE DUSTING FOR ADDITION OF DWPF FRIT TO THE SLURRY MIX EVAPORATOR

The Defense Waste Processing Facility (DPWF) presently is in the process to determine means to reduce water utilization in the Slurry Mix Evaporator (SME) process, thus reducing effluent and processing times. The frit slurry addition system mixes the dry frit with water, yielding approximately a 50 weight percent slurry containing frit and the other fraction water. This slurry is discharged into the SME and excess water is removed via boiling. To reduce this water load to the SME, DWPF has proposed using a pneumatic system in conveying the frit to the SME, in essence a dry delivery system. The problem associated with utilizing a dry delivery system with the existing frit is the generation of dust when discharged into the SME. The use of water has been shown to be effective in the mining industry as well in the DOE complex to mitigate dusting. The method employed by SRNL to determine the quantity of water to mitigate dusting in dry powders was effective, between a lab and bench scale tests. In those tests, it was shown that as high as five weight percent (wt%) of water addition was required to mitigate dust from batches of glass forming minerals used by the Waste Treatment Plant at Hanford, Washington. The same method used to determine the quantity of water to mitigate dusting was used in this task to determine the quantity of water to mitigate this dusting using as-received frit. The ability for water to mitigate dusting is due to its adhesive properties as shown in Figure 1-1. Wetting the frit particles allows for the smaller frit particles (including dust) to adhere to the larger frit particles or to agglomerate into large particles. Fluids other than water can also be used, but their adhesive properties are different than water and the quantity required to mitigate dusting is different, as was observed in reference 1. Excessive water, a few weight percentages greater than that required to mitigate dusting can cause the resulting material not to flow. The primary objective of this task is to perform bench scale testing on various frits that have been used at DWPF or in test programs at SRNL to determine the quantity of de-ionized (DI) water required to mitigate dusting per mass basis of frit. The quantity of DI water required was determined visually by observing the effluent port of the mixer, and DI water addition was made to the point where no visible dust was observed leaving the effluent port. A total of eight different frits were selected for testing. Secondary objectives in this task include the following: (1) Video taping of the de-dusting procedure, (2) Particle size distribution analyses of the dry and wetted frits at the weight fraction of water required for de-dusting, (3) Plate flow tests to determine angle of flow and quantity of material remaining on plate at 90 degrees, (4) Microscopy of dry and wetted frit, and (5) Effect of excess water for selected frits on plate flow. The above analyses were performed within one hour of water addition, to minimize the effect of evaporative water losses. To better understand the size of dust particles, perform settling tests on selected frits and capture the fines. Analyze the fines for particle size distribution. Finally, it is expected that the surface area of frit is an important parameter in the quantity of water required for dust mitigation. An analysis of particle size distribution (PSD) data of as-received frit analyzed by SRNL over the past two to three years will be performed to determine the variation in the distribution of as-received frit. The following objectives were stated in the Technical Task Request4 as objectives that given adequate time would provide insight in helping DWPF in assessing equipment or processes for de-dusting and processing of dry frit. Due to time constraints, commercial methods for dedusting are provided. These results are detailed in section 3.7. Obtain design information from Hanford with respective to equipment used for dedusting. Suggestions on enhanced design features, such as flush water, pipe air purges, humidified compressed air, options for agitation, and other base (SRNL) knowledge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermoeconomic Evaluation and Optimization of Using Different Environmentally Friendly Refrigerant Pairs for a Dual-Evaporator Cascade Refrigeration System

Applications of dual-evaporator refrigeration systems have recently gained much attention both in academia and industry due to their multiple benefits. In this study, a comprehensive thermodynamic and economic analysis is conducted to evaluate the potential of using several environmentally friendly refrigerant couples and identifies the most suitable one yielding the best economic results. To achieve this goal, a detailed parametric study is conducted, and an optimization process is performed using a particle swarm optimization (PSO) approach to minimize the unit production cost of cooling (UPCC) of the cascade refrigeration system. The results showed that among all selected 18 refrigerant pairs and for all ranges of examined operating parameters, the R170-R161 pair and R1150-R1234yf pair are identified as the best and worst pairs, respectively, from both thermodynamic and economic viewpoints. The results also confirm that R170-R161 pair has an improvement over R717-R744, used as a typical refrigerant pair of cascade refrigeration cycles. For a base case analysis, the COP of R170-R161 and R1150-R1234yf pairs is determined as 1.727 and 1.552, respectively, while their UPCC is found to be $0.395/ton-hr and $0.419/ton-hr, respectively, showing the influence of proper selection of refrigerant pairs on the cascade cycle’s performance. Overall, this study offers a useful thermodynamic and economic insight regarding the selection of proper refrigerant pairs for a dual-evaporator cascade vapor compression refrigeration system.

42 ENGINEERING↗

SLIPPING MAGNETIC RECONNECTION, CHROMOSPHERIC EVAPORATION, IMPLOSION, AND PRECURSORS IN THE 2014 SEPTEMBER 10 X1.6-CLASS SOLAR FLARE

We investigate the occurrence of slipping magnetic reconnection, chromospheric evaporation, and coronal loop dynamics in the 2014 September 10 X-class flare. Slipping reconnection is found to be present throughout the flare from its early phase. Flare loops are seen to slip in opposite directions toward both ends of the ribbons. Velocities of 20–40 km s{sup −1} are found within time windows where the slipping is well resolved. The warm coronal loops exhibit expanding and contracting motions that are interpreted as displacements due to the growing flux rope that subsequently erupts. This flux rope existed and erupted before the onset of apparent coronal implosion. This indicates that the energy release proceeds by slipping reconnection and not via coronal implosion. The slipping reconnection leads to changes in the geometry of the observed structures at the Interface Region Imaging Spectrograph slit position, from flare loop top to the footpoints in the ribbons. This results in variations of the observed velocities of chromospheric evaporation in the early flare phase. Finally, it is found that the precursor signatures, including localized EUV brightenings as well as nonthermal X-ray emission, are signatures of the flare itself, progressing from the early phase toward the impulsive phase, with the tether-cutting being provided by the slipping reconnection. The dynamics of both the flare and outlying coronal loops is found to be consistent with the predictions of the standard solar flare model in three dimensions.

79 ASTRONOMY AND ASTROPHYSICS↗

Explosive chromospheric evaporation in a circular-ribbon flare

In this paper, we report our multiwavelength observations of the C4.2 circular-ribbon flare in active region (AR) 12434 on 2015 October 16. The short-lived flare was associated with positive magnetic polarities and a negative polarity inside, as revealed by the photospheric line-of-sight magnetograms. Such a magnetic pattern is strongly indicative of a magnetic null point and spine-fan configuration in the corona. The flare was triggered by the eruption of a mini-filament residing in the AR, which produced the inner flare ribbon (IFR) and the southern part of a closed circular flare ribbon (CFR). When the eruptive filament reached the null point, it triggered null point magnetic reconnection with the ambient open field and generated the bright CFR and a blowout jet. Raster observations of the Interface Region Imaging Spectrograph show plasma upflow at speeds of 35–120 km s{sup −1} in the Fe xxi λ1354.09 line (logT≈7.05) and downflow at speeds of 10–60 km s{sup −1} in the Si iv λ1393.77 line (logT≈4.8) at certain locations of the CFR and IFR during the impulsive phase of the flare, indicating explosive chromospheric evaporation. Coincidence of the single hard X-ray source at 12–25 keV with the IFR and calculation based on the thick-target model suggest that the explosive evaporation was most probably driven by nonthermal electrons.

79 ASTRONOMY AND ASTROPHYSICS↗

Breakthrough Video: Desiccant Enhanced Evaporative Air Conditioning

Researchers at the National Renewable Energy Laboratory (NREL) invented a breakthrough technology that improves air conditioning in a novel way—with heat. NREL combined desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90% less electricity and up to 80% less total energy than traditional air conditioning (AC). This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental Evaluation of a Residential Refrigerator with a Novel Rotating Heat Exchanger as an Evaporator

Residential refrigerator designs have improved significantly over the recent years to achieve the required federal minimum energy standard and match with consumer expectations. Designers have been able to use innovative design features and components; however, evaporator designs have lagged in performance improvement due to the need to properly manage frost and maximize the freezer interior volume. Rotating Heat Exchangers (RHX) provide an innovative solution that addresses both of these concerns. The rotation of the fins results in continuous disruption to the boundary layer, hence reducing the overall thermal resistance. Thus, for the same capacity, the heat transfer area can be greatly reduced. Furthermore, the rotation inhibits frost growth on the fins and reduces the time and frequency of defrosting. In this paper, we present an experimental evaluation of the RHX in a benchtop refrigerant loop system showing results for different operating configurations. Cooling capacity, cooling COP, and overall energy consumption are investigated. High-speed imaging is also used to capture frost growth patterns over time on the RHX fins in the presence and absence of rotation. The results show that the rotating heat exchanger evaporator is capable of meeting the 100 W capacity requirement of residential refrigerators, while offering the potential of significant reduction in defrost energy consumption.

Evaporator↗

Minimizing environmental risk through the use of evaporation - 15090

At the Hanford Site, work is being done to utilize a portable exhauster to reduce the remaining free liquid in the older underground storage tanks. Use of an exhauster allows the water in the free liquid to be evaporated reducing the possibility that mobile contaminants will leak into the soil and groundwater. Transferring the remaining liquid waste to newer tanks requires major infrastructure installation. Currently one set of tanks is undergoing the retrieval of solids and liquids. This retrieval requires substantial infrastructure in order to mobilize and pump the waste to newer tanks. Reducing the remaining liquid waste by pumping would require much of the same retrieval infrastructure and is cost prohibitive. The use of a portable exhauster will require minimal infrastructure and is much more efficient. Past results have demonstrated that this technology can be successfully used on various sizes of underground storage tanks. A portable exhauster is planned to be connected to the one tank believed to be leaking and will be used to evaporate the remaining free liquid, beginning in 2015. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contaminant Entrainment in a Liquid Fuel Fire with Multi-Component Evaporation Droplet Model

A number of fire scenarios can result in the release of hazardous chemical or radiological contaminants as sub-micron solid particulates, posing a significant danger of inhalation. These particulates may be entrained in the air around the fire through a variety of mechanisms including liquid droplet formation above the boiling surface of the contaminated fuel. The formation of both film drops from the rupture of a liquid film as a boiling bubble bursts and jet drops from the collapse of the cavity of a ruptured bubble may be involved. A 2015 study by Brown and Louie focused on such a fire scenario to investigate the physics of contaminant release. This paper extends that study by supplementing the existing physics models with a multicomponent evaporation mechanism, where liquid droplets formed near the boiling fuel surface experience evaporation of their various components at different rates based on distinct material properties (density, specific heat, heat of vaporization, etc.). As in the Brown and Louie study, the Sierra low-Mach module Fuego is used as the Lagrangian-Eulerian code for simulation of this scenario. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Crystallization Temperature of Aqueous Lithium Bromide Solutions at Low Evaporation Temperature

Water- aqueous Lithium Bromide (LiBr) solutions have shown superior performance as working fluid pairs for absorption refrigeration cycles. Most of the available literature (e.g. ASHRAE Handbook of Fundamentals, etc.) provide crystallization behavior down to only 10 C. The typical evaporating temperature for an absorption chiller system is usually lower than 10 C. Hence, it is essential to have an accurate prediction of the crystallization temperature in this range in order to avoid crystallization during the design phase. We have therefore conducted a systematic study to explore the crystallization temperatures of LiBr/Water solutions that fall below an evaporating temperature of 10 C. Our preliminary studies revealed that the rate of cooling of the sample solution influences the crystallization temperature; therefore we have performed a quasi steady test where the sample was cooled gradually by reducing the sample temperature in small steps. Results from this study are reported in this paper and can be used to extend the data available in open literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaporation estimates using weather station data and boundary layer theory

Global estimates of evapotranspiration remain a challenge. In this study, we show that the daily course of air temperature and specific humidity available at routine weather stations can be used to estimate evapotranspiration and the evaporative fraction, the ratio of latent heat flux to available energy at the surface. Indeed, the diurnal increase in air temperature reflects the magnitude of the sensible heat flux and the increase of specific humidity after sunrise reflects the amplitude of evapotranspiration. Here, the method is physically constrained and based on the budget of heat and moisture in the boundary layer. Unlike land surface-based estimates, the proposed boundary layer estimate does not rely on ad hoc surface resistance parameterizations (e.g., Penman-Monteith). The proposed methodology can be applied to data collected at weather stations to estimate evapotranspiration and evaporative fraction under cloudy conditions and in the pre–remote sensing era.

54 ENVIRONMENTAL SCIENCES↗

Rain evaporation and moist patches in tropical boundary layers

Moist patches are areas in the subcloud layer characterized by a positive water vapor anomaly compared to the environment and are considered important in triggering new convective cells. A correct understanding of the origin of the water vapor in these patches is, thus, essential to improving existing convective parameterizations. Recent studies have addressed this problem and have shown that contrary to what was previously thought, the main source of water vapor in moist patches are surface latent heat fluxes, instead of rain evaporation. This paper offers a different perspective to the topic, focusing on the origin only of the water vapor that makes moist patches anomalously moist when compared to the environment. Finally, it is found that near the surface, rain evaporation contributes half as much as latent heat fluxes, implying that a parameterization of the thermodynamic forcing should be more sensitive to environmental variables, like relative humidity, than recently suggested.

54 ENVIRONMENTAL SCIENCES↗

Evaporated Se x Te 1-x Thin Films with Tunable Bandgaps for Short-Wave Infrared Photodetectors

Semiconducting absorbers in high-performance short-wave infrared (SWIR) photodetectors and imaging sensor arrays are dominated by single-crystalline germanium and III-V semiconductors. However, these materials require complex growth and device fabrication procedures. In this work, thermally evaporated Se x Te 1- x alloy thin films with tunable bandgaps for the fabrication of high-performance SWIR photodetectors are reported. From absorption measurements, it is shown that the bandgaps of Se x Te 1- x films can be tuned continuously from 0.31 eV (Te) to 1.87 eV (Se). Owing to their tunable bandgaps, the peak responsivity position and photoresponse edge of Se x Te 1- x film-based photoconductors can be tuned in the SWIR regime. By using an optical cavity substrate consisting of Au/Al 2 O 3 to enhance its absorption near the bandgap edge, the Se 0.32 Te 0.68 film (an optical bandgap of ≈0.8 eV)-based photoconductor exhibits a cut-off wavelength at ≈1.7 μm and gives a responsivity of 1.5 AW -1 and implied detectivity of 6.5 × 10 10 cm Hz 1/2 W -1 at 1.55 μm at room temperature. Importantly, the nature of the thermal evaporation process enables the fabrication of Se 0.32 Te 0.68 -based 42 × 42 focal plane arrays with good pixel uniformity, demonstrating the potential of this unique material system used for infrared imaging sensor systems.

36 MATERIALS SCIENCE↗

Sodium doping of solution-processed amine-thiol based CIGS solar cells by thermal evaporation of NaCl

Poor crystallinity, high degree of porosity and rough surfaces are the main drawbacks of solution-processed CIGS absorbers resulting in lower power conversion efficiencies when compared to vacuum-based CIGS solar cells. Therefore, promoting absorber grain growth is key to further improve solution-based solar cell performance. The effect of alkali elements such as Na in CIGS absorbers is generally recognised to have beneficial effects not only on the absorber opto-electronic properties but also on the grain growth. In this work, thermal evaporation of a thin layer of NaCl prior to selenisation resulted in absorbers with significantly larger CIGS grains than previously seen with Na diffusing directly from the from soda-lime glass substrate. NaCl is non-toxic, abundant and readily available compound that has not been typically used as an evaporation source, but rather as an additive into CIGS precursor solution. The effect of Na on these solution-processed CIGS devices was primarily observed in the spectacular morphological changes leading to improved carrier collection and minority carrier lifetimes, but less on the absorber doping. Transmission electron microscopy (TEM) revealed voids forming around large CIGS grains upon NaCl addition and these had a negative effect on inter-grain carrier transport. Nonetheless, the resulting device performance doubled from 5% to 10% with addition of Na using this doping approach; however, a compromise between the optimum grain growth and optimum electronic properties had to be made. This study demonstrates a novel, simple and effective Na-doping strategy for CIGS absorbers and reveals the current limitations of the Na-doping in solution-processed atmospherically deposited cells.

14 SOLAR ENERGY↗

A random unitary circuit model for black hole evaporation

Inspired by the Hayden-Preskill protocol for black hole evaporation, we consider the dynamics of a quantum many-body qudit system coupled to an external environment, where the time evolution is driven by the continuous limit of certain 2-local random unitary circuits. We study both cases where the unitaries are chosen with and without a conserved U(1) charge and focus on two aspects of the dynamics. First, we study analytically and numerically the growth of the entanglement entropy of the system, showing that two different time scales appear: one is intrinsic to the internal dynamics (the scrambling time), while the other depends on the system-environment coupling. In the presence of a U(1) conserved charge, we show that the entanglement follows a Page-like behavior in time: it begins to decrease in the middle stage of the “evaporation”, and decreases monotonically afterwards. Second, we study the time needed to retrieve information initially injected in the system from measurements on the environment qudits. Based on explicit numerical computations, we characterize such time both when the retriever has control over the initial configuration or not, showing that different scales appear in the two cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗