Phase IB study of ziv-aflibercept plus pembrolizumab in patients with advanced solid tumors

Background The combination of antiangiogenic agents with immune checkpoint inhibitors could potentially overcome immune suppression driven by tumor angiogenesis. We report results from a phase IB study of ziv-aflibercept plus pembrolizumab in patients with advanced solid tumors. Methods This is a multicenter phase IB dose-escalation study of the combination of ziv-aflibercept (at 2–4 mg/kg) plus pembrolizumab (at 2 mg/kg) administered intravenously every 2 weeks with expansion cohorts in programmed cell death protein 1 (PD-1)/programmed death-ligand 1(PD-L1)-naïve melanoma, renal cell carcinoma (RCC), microsatellite stable colorectal cancer (CRC), and ovarian cancer. The primary objective was to determine maximum tolerated dose (MTD) and recommended dose of the combination. Secondary endpoints included overall response rate (ORR) and overall survival (OS). Exploratory objectives included correlation of clinical efficacy with tumor and peripheral immune population densities. Results Overall, 33 patients were enrolled during dose escalation (n=3) and dose expansion (n=30). No dose-limiting toxicities were reported in the initial dose level. Ziv-aflibercept 4 mg/kg plus pembrolizumab 2 mg/kg every 2 weeks was established as the MTD. Grade ≥3 adverse events occurred in 19/33 patients (58%), the most common being hypertension (36%) and proteinuria (18%). ORR in the dose-expansion cohort was 16.7% (5/30, 90% CI 7% to 32%). Complete responses occurred in melanoma (n=2); partial responses occurred in RCC (n=1), mesothelioma (n=1), and melanoma (n=1). Median OS was as follows: melanoma, not reached (NR); RCC, 15.7 months (90% CI 2.5 to 15.7); CRC, 3.3 months (90% CI 0.6 to 3.4); ovarian, 12.5 months (90% CI 3.8 to 13.6); other solid tumors, NR. Activated tumor-infiltrating CD8 T cells at baseline (CD8+PD1+), high CD40L expression, and increased peripheral memory CD8 T cells correlated with clinical response. Conclusion The combination of ziv-aflibercept and pembrolizumab demonstrated an acceptable safety profile with antitumor activity in solid tumors. The combination is currently being studied in sarcoma and anti-PD-1-resistant melanoma. Trial registration number NCT02298959 .

Rahma, Osama E.↗

Synergistically combining peracetic acid and reduced graphene oxide membranes to degrade trace organic contaminants

The removal of trace organic contaminants is a critical step for the reuse of municipal and industrial wastewater. Herein, we demonstrate a catalytic membrane platform synergistically integrating reduced graphene oxide (rGO) membranes and peracetic acid (PAA) oxidation, using a dye of methylene blue (MB) and a pesticide of 2,4-dichlorophenoxyacetic acid (2,4-D) as model contaminants. In a crossflow system with rGO membrane and 25 ppm PAA, the degradation rates of MB and 2,4-D were 22 and 0.12 g h −1 per g rGO, with an initial concentration of 10 and 1.1 ppm, respectively. The degradation time profile of MB and 2,4-D follows a pseudo-first-order model, and the degradation rate constant increases with increasing initial PAA doses. Here, the rGO membranes also exhibited good stability over a 1-month test for 2,4-D degradation. In addition to the nanofiltration performance of the rGO membrane, the integrated PAA-rGO membrane process shows great potential to degrade various organic contaminants without the need to separate and recover the metal-free catalyst in downstream treatment.

2,4-D↗

Fading study of Harshaw LiF:Mg,Ti thermoluminescence dosimeters exposed to neutron doses

Sensitivity and signal fading were tested in Harshaw LiF:Mg,Ti thermoluminescence dosimeters (TLDs) exposed to neutron and beta/photons doses. A significant difference in the signal fading rate was observed for TLDs exposed to neutrons compared with TLDs exposed to betas. This difference may have been related to differences in glow curves for dosimeters exposed to different beams and to differences in glow curve evolution after exposure. A fading-correction algorithm was developed to correct the cumulative sensitivity + signal fading of TL doses for the fading time t using the formulae: y = 0.147∗exp(-t/4.36) + 0.308∗exp(-t/34.1) + 0.73 for neutrons, and: y = 0.132∗exp(-t/10.72) + 0.174∗exp(-t/31.5) + 0.8 for betas/photons. The formula was validated using the dose recovery test, where the average deviation of fading-corrected doses from delivery doses was within 1%. In conclusion, the proposed fading-correction approaches may significantly improve the accuracy of Harshaw TL dosimetry with LiF:Mg,Ti cards for both neutron and beta/gamma irradiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Psychosomatic Bias in Low-dose Radiation Epidemiology: Assessing the Role of Radiophobia and Stress in Cancer Incidence

Abstract Historical assessment of radiation effects at low doses (below 0.2 Sv) are generally the result of back extrapolation from higher doses, which are known to have a linear relation between risk and dose. There are multiple counter-examples, and some literature argues that a threshold, nonlinear, or even a beneficial effect (hormeisis) can occur from radiation below these doses. The common theme found in all of these studies stems from the traditional approach of correlating disease rates to stimulus and then effectively curve-fitting the result toward zero dose. What has not been considered in general are the personal stress levels of the exposed individuals due to fear of cancer from low doses. The increased levels of cortisol due to the psychological stress from fear or depression has been shown in the literature to increase cancer probability. The extent to which low-dose exposed individuals were highly fearful or stressed from the radiation exposure would then give rise to elevated cancer based on stress rather than a fundamental radiogenic mechanism. If the population under epidemiological study is aware of a potential historical exposure (no matter how small) and has then lived under stress from fear or depression due to that exposure, the psychosomatic effects will bias the epidemiology accordingly and so should be quantified and accounted for as done with the effects of smoking. Health Phys. 129(0):000-000; 2025

Environmental Sciences & Ecology↗

Protection against Different Genotypes of Newcastle Disease Viruses (NDV) Afforded by an Adenovirus-Vectored Fusion Protein and Live NDV Vaccines in Chickens

The efficacy of an adenovirus-vectored Newcastle disease virus (NDV) vaccine expressing the fusion (F) NDV protein (adeno-F) was evaluated against challenges with virulent heterologous and homologous NDV strains to the F protein. In a preliminary study, two different doses (low and high) of adeno-F were tested against a virulent NDV strain containing the homologous NDV F protein, CA02. In a second study, at three weeks post-vaccination, the efficacy of the high dose of adeno-F was compared to a live attenuated NDV vaccine strain (LaSota) against three antigenically distinct virulent NDV challenge strains, one homologous (CA02) and two heterologous (TZ12, EG14) to F in the vectored vaccine. In both experiments, clinical signs, mortality, virus shedding, and humoral response were evaluated. In the first experiment, the survival rates from birds vaccinated with adeno-F at a high and low dose were 100% and 25%, respectively. In the second experiment, birds vaccinated with the high dose of adeno-F had a survival rate of 80%, 75%, and 65% after challenge with the CA02, TZ12, and EG14 viruses, respectively. All of the LaSota-vaccinated birds survived post-challenge no matter the NDV challenge strain. High antibody titers were detected after vaccination with LaSota by HI and ELISA tests. The majority of adeno-F-vaccinated birds had detectable antibodies using the ELISA test, but not using the HI test, before the challenge. The data show that both the similarity of the F protein of the adeno-F vaccine to the challenge virus and the adeno-F vaccination dose affect the efficacy of an adenovirus-vectored NDV vaccine against a virulent NDV challenge.

Ferreira, Helena L. (ORCID:0000000232613712)↗

Radiation hard gallium oxide scintillators for high count rate radiation detection

Despite decades of materials research, the availability of appropriate crystalline radiation-hard scintillators with ultrafast decay times (~10ns) and high light yields (>2000 ph/MeV) are still limited. In this study, we demonstrate the potential of gallium oxide (β-Ga 2 O 3 ) based scintillators for high count rate applications. The low-cost rugged β-Ga 2 O 3 scintillators were grown using the optical float zone (FZ) technique. Several dopants and growth atmospheres were used to demonstrate the balance between ultrafast primary decay time and the light yield of the scintillators. Light yields as high as 6446 ± 716 ph/MeV were obtained with 18.3 ns decay time for 662 keV gamma rays. Decay times as fast as 12ns were obtained with a 3212 ± 357 ph/MeV light yield. An excellent 662 keV gamma energy resolution of 7% was obtained using the β-Ga 2 O 3 :Ce crystals. Even with these excellent scintillation properties, the gamma radiation hardness of β-Ga 2 O 3 crystals was better than the leading radiation-hard lead tungstate (PbWO 4 ) crystals. Twenty-six scintillators fabricated from the grown β-Ga 2 O 3 crystals were tested for radiation hardness with a 60 Co gamma irradiation rate of 14 krad/h with a total radiation dose of 2 Mrad. The scintillation properties of these crystals remained unaffected. To date, no other scintillator has demonstrated such high radiation resistance. Furthermore, these FZ-grown low-cost, non-hygroscopic, and high-density β-Ga 2 O 3 scintillators can replace the existing scintillators in many applications ranging from nuclear and high energy physics experiments to nuclear security.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation damages the silicates present in polyphasic mineral aggregates causing concrete’s degradation

While many U.S. nuclear power plants have submitted Subsequent License Renewal Application to operate beyond 60 years, others are already considering Operations Beyond Eighty years. In such cases, concrete biological shields are exposed to neutron and gamma radiation exceeding prescribed thresholds. Radiation-induced volumetric expansion (RIVE), extensively studied in single crystals, may also contribute to the degradation of polycrystalline aggregates. Since minerals differ in atomic structure and chemistry, radiation can affect them in distinct ways. This study examines quartzite, marble, and limestone to evaluate how irradiation affects their physical attributes and chemical reactivity. Results show crystalline silicates experience significant RIVE damage and enhanced reactivity in alkaline solutions compared to non-irradiated phases. Enhanced intra- and inter-granular dissolution could compromise aggregate integrity. An empirical correlation links silicate dissolution rate to atomic constraints (density, rigidity) and radiation dose, providing a predictive framework for estimating changes in silicate aggregate properties within radiation-exposed concrete.

Bouissonnié, Arnaud [Univ. of California, Los Ange↗

Software Validation Work With The ZPPR-15 Data

The analysis activities for fast reactors involve using many different pieces of software that are relied upon for their predictive capabilities. For this software to be considered reliable, documented proof that the predictions of the software are accurate is required. In this manuscript, the validation work that covers some of the Argonne software used in fast reactor design activities is discussed and displayed. This validation work includes neutron and gamma flux distributions, reaction rate distributions, and reactivity worth. In an ideal world, a reactor development program would have access to a comprehensive set of experimental facilities to help inform the design aspects of the reactor itself. While thermal-hydraulics experiments, and to a limited degree mechanical experiments, can be carried out today for validation needs, neutronics related experimental facilities are rather impractical because of the lack of experimental facilities. Given the desired time table for construction of new reactors, the reconstitution or creation of new neutronic experimental facilities is untenable and thus those reactor development programs must rely upon any available experimental measurements that are qualitatively similar to the design. While a methodology has been proposed to assess the similarity between the past experimental measurements and the reactor itself, that aspect is beyond the scope of this manuscript. In this manuscript, the focus is entirely placed on the analysis results for a series of experiments carried out at the ZPPR facility in Idaho in the mid-1980s. In this regard, this manuscript only shows the validation of the stated neutronics software for specific loadings of the ZPPR reactor. Because of the fuel form, its proposed enrichment, and the material content of the reactor core, the ZPPR-15 experiments were identified as potential validation data for the reactor. The ZPPR-15 experiments were intended as mockups of a 330 MWe Integral Fast Reactor program which was a follow on program to the Clinch River Breeder Reactor. In the ZPPR-15 series of experiments, measurements of the neutron spectrum, control rod worth, sodium void worth, foil reaction rate distributions, Doppler worth of heated samples, gamma dose, and axial expansion worth were all carried out and published. In many cases, these reactivity coefficients are good candidates to validate the reactivity coefficient calculation scheme used by the analysis software and included in the safety analysis activities of fast reactor development projects today. This manuscript discusses the modeling methodology and accuracy of the calculated experimental results using the LANL software MCNP and the ANL software package ARC (Argonne Reactor Codes). As will be shown, for many of the experimental measurements, the two software packages are found to be good predictive analysis tools for those experiments. In other cases, problems with the analysis methodology or underlying cross section data are exposed which indicates where predictive analysis is not as reliable. Finally, in some of the measurements the conclusion is reached that the experimental measurement cannot be reproduced with the analysis software as it is simply too difficult.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Software Validation Work With The ZPPR-15 Data

The analysis activities for fast reactors involve using many different pieces of software that are relied upon for their predictive capabilities. For this software to be considered reliable, documented proof that the predictions of the software are accurate is required. In this manuscript, the validation work that covers some of the Argonne software used in fast reactor design activities is discussed and displayed. This validation work includes neutron and gamma flux distributions, reaction rate distributions, and reactivity worth. In an ideal world, a reactor development program would have access to a comprehensive set of experimental facilities to help inform the design aspects of the reactor itself. While thermal-hydraulics experiments, and to a limited degree mechanical experiments, can be carried out today for validation needs, neutronics related experimental facilities are rather impractical because of the lack of experimental facilities. Given the desired time table for construction of new reactors, the reconstitution or creation of new neutronic experimental facilities is untenable and thus those reactor development programs must rely upon any available experimental measurements that are qualitatively similar to the design. While a methodology has been proposed to assess the similarity between the past experimental measurements and the reactor itself, that aspect is beyond the scope of this manuscript. In this manuscript, the focus is entirely placed on the analysis results for a series of experiments carried out at the ZPPR facility in Idaho in the mid-1980s. In this regard, this manuscript only shows the validation of the stated neutronics software for specific loadings of the ZPPR reactor. Because of the fuel form, its proposed enrichment, and the material content of the reactor core, the ZPPR-15 experiments were identified as potential validation data for the reactor. The ZPPR-15 experiments were intended as mockups of a 330 MWe Integral Fast Reactor program which was a follow on program to the Clinch River Breeder Reactor. In the ZPPR-15 series of experiments, measurements of the neutron spectrum, control rod worth, sodium void worth, foil reaction rate distributions, Doppler worth of heated samples, gamma dose, and axial expansion worth were all carried out and published. In many cases, these reactivity coefficients are good candidates to validate the reactivity coefficient calculation scheme used by the analysis software and included in the safety analysis activities of fast reactor development projects today. This manuscript discusses the modeling methodology and accuracy of the calculated experimental results using the LANL software MCNP and the ANL software package ARC (Argonne Reactor Codes). As will be shown, for many of the experimental measurements, the two software packages are found to be good predictive analysis tools for those experiments. In other cases, problems with the analysis methodology or underlying cross section data are exposed which indicates where predictive analysis is not as reliable. Finally, in some of the measurements the conclusion is reached that the experimental measurement cannot be reproduced with the analysis software as it is simply too difficult.

Aliberti, Gerardo↗

Tank 11H Low Temperature Aluminum Dissolution and Inhalation Dose Potential Analyses at Savannah River Site – 26018

Currently, there is approximately 34 million gallons of high-level radioactive tank waste in the Tank Farm at the Savannah River Site (SRS). The ultimate goal of operations at the Tank Farm is to remove the high level waste (HLW) from the tanks followed by stabilization of the waste through vitrification of the HLW into glass or grouting the decontaminated waste into saltstone. After bulk removal of the HLW consisting of sludge, saltcake, and supernatant, further efforts are made to reduce the residual waste present in the tank in order to declare preliminary cease waste removal (PCWR) signifying completion of HLW removal. These reduction efforts can include tank washing to remove soluble salts and radioisotopes and dissolution of solids including aluminum. Aluminum in the form of gibbsite and boehmite is relatively insoluble in water. Through addition of aqueous sodium hydroxide, the aluminum can be dissolved at mild temperatures. In order for the waste tank to meet closure mode requirements of the Concentration, Storage, and Transfer Facilities (CSTF), which includes the Tank Farm, Documented Safety Analysis (DSA), a component of the safety basis, the inhalation dose potential (IDP) and the radiolytic hydrogen generation rate of the stored waste must be demonstrated to be lower than their respective designated limits. These parameters are calculated from measured radiochemical analyses of isotopes that emit a high amount of radioactivity including Cs-137, Sr-90, Pu-238, Pu-239, Pu-240, Pu-241, Am-241, and Cm-244. Following the low temperature aluminum dissolution (LTAD) process, Tank 11H slurry samples were pulled from the tank and sent to Savannah River National Laboratory (SRNL) to measure the extent of aluminum dissolution, hydroxide concentration, densities of slurry and supernatant, weight percent solids analyses, and radionuclide activities. The analyses of the composite sample found that approximately 90% of the total aluminum in the slurry was dissolved, indicating successful reduction of the insoluble aluminum in the waste tank. Additionally, the weight percent insoluble solids (slurry basis) measurement of the composite sample was found to be approximately 1%, demonstrating that minimal solids still remain in the tank. Finally, the radiochemical analyses of the composite sample determined that the waste contents of the tank met the IDP and radiolytic hydrogen generation rate requirements of the CSTF DSA. These measurements have shown that the LTAD process in Tank 11H was successful in waste reduction efforts and a positive step towards declaring PCWR and tank closure at SRS.

Dekarske, John [Savannah River National Laboratory↗

Idaho National Laboratory CY 2024 National Emission Standards for Hazardous Air Pollutants Analysis, Methodology, and Results for Radionuclides

This report documents the methodology and results for calculating the effective dose equivalent (EDE) to the maximally exposed individual (MEI) from atmospheric radionuclide emissions from Idaho National Laboratory (INL) sources in Calendar Year (CY) 2024. The calculations were performed in accordance with requirements in Code of Federal Regulations (CFR), Title 40, “Protection of the Environment,” Part 61, “National Emission Standards for Hazardous Air Pollutants (NESHAPs),” Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” (40 CFR 61, Subpart H). UDFs were calculated using the computer model CAP88-PC for unit (1 Ci/yr) emission rates at INL Site facilities and INL in-town (Idaho Falls) facilities and stored in Microsoft Access databases. The UDFs—in this case, mrem/Ci—were then combined with radionuclide-specific release (emission) rates for each facility-specific source to compute doses at predetermined public receptor locations, including the MEI locations. This report contains the dose results and a description of the methodology and tools used to compute the doses.

07 - ISOTOPES AND RADIATION SOURCES↗

Air Exchange Rate Impact on Activity Equilibrium Factors and Inhalation Fractional Equilibrium Factors for Rn, Xe, Kr, Ar, Ne, and Their Progeny in Vapor Intrusion, Risk, and Dose Models

Exposure to the radioactive noble gasses, especially radon, is of high concern and poses a significant risk to humans in an indoor air environment as the second leading cause of lung cancer in the United States. To evaluate and minimize the risks posed by these gasses, it is important to understand their radiological and physical properties. The EPA’s Radon Vapor Intrusion Screening Level (RVISL) calculator calculates indoor air RVISLs based on target working levels (WLs), target excess lifetime cancer risk (ELCR), and annual dose limits for the actinon (Rn-219), thoron (Rn-220), and radon (Rn-222) decay series. The RVISLs are based on inhalation and submersion in gas cloud exposure routes for residential and commercial settings. The RVISLs are analogous to preliminary remediation goals (PRGs) and dose compliance concentrations (DCCs), where the isotope-specific values are in units of activity concentration (activity per unit volume). If the concentration of a parent isotope of radon or its progeny is found to exceed the RVISL, then further action to ensure cleanup of the contaminant may be necessary. In residential and commercial settings, the RVISLs will vary based on the air exchange rate present. The EPA’s Radionuclide PRG and DCC Calculators also assess the risk/dose from noble gases in the air due to household use of water like showering. In this study, a computational method in MATLAB was developed to determine the impact of the air exchange rate on the activity equilibrium factor (A eq ) and the inhalation fractional equilibrium factor (F eq ). Both factors are values that reflect the equilibrium concentrations of progeny to their parent in the air. These factors have a direct impact on the RVISL, PRG, and DCC calculations of WL, ELCR, and annual dose, respectively. This study builds on a previous report that only focused on actinon, thoron, and radon by revisiting the original A eq and F eq calculation methods, as well as including the values for the Rn-207, Rn-209, Rn-210, Rn-211, Rn-215, Rn-216, Rn-217, Rn-218, Rn-223, Ne-24, Ar-42, Ar-43, Ar-44, Kr-74, Kr-75, Kr-76, Kr-77, Kr-88, Kr-89, Xe-120, Xe-121, Xe-122, Xe-123, Xe-135m, and Xe-138 decay chains, which are not currently available in literature. The EPA’s RVISL calculator will be updated to include the new A eq and F eq values for the actinon, thoron, and radon decay chains, while the rest of the calculators will incorporate all the new A eq and F eq values as appropriate.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Oxamniquine derivatives overcome Praziquantel treatment limitations for Schistosomiasis

Human schistosomiasis is a neglected tropical disease caused by Schistosoma mansoni, S. haematobium, and S. japonicum. Praziquantel (PZQ) is the method of choice for treatment. Due to constant selection pressure, there is an urgent need for new therapies for schistosomiasis. Previous treatment of S. mansoni included the use of oxamniquine (OXA), a drug that is activated by a schistosome sulfotransferase (SULT). Guided by data from X-ray crystallography and Schistosoma killing assays more than 350 OXA derivatives were designed, synthesized, and tested. We were able to identify CIDD-0150610 and CIDD-0150303 as potent derivatives in vitro that kill (100%) of all three Schistosoma species at a final concentration of 71.5 μM. We evaluated the efficacy of the best OXA derivates in an in vivo model after treatment with a single dose of 100 mg/kg by oral gavage. The highest rate of worm burden reduction was achieved by CIDD -150303 (81.8%) against S. mansoni, CIDD-0149830 (80.2%) against S. haematobium and CIDD-066790 (86.7%) against S. japonicum. We have also evaluated the ability of the derivatives to kill immature stages since PZQ does not kill immature schistosomes. CIDD-0150303 demonstrated (100%) killing for all life stages at a final concentration of 143 μM in vitro and effective reduction in worm burden in vivo against S. mansoni. To understand how OXA derivatives fit in the SULT binding pocket, X-ray crystal structures of CIDD-0150303 and CIDD-0150610 demonstrate that the SULT active site will accommodate further modifications to our most active compounds as we fine tune them to increase favorable pharmacokinetic properties. Treatment with a single dose of 100 mg/kg by oral gavage with co-dose of PZQ + CIDD-0150303 reduced the worm burden of PZQ resistant parasites in an animal model by 90.8%. Therefore, we conclude that CIDD-0150303, CIDD-0149830 and CIDD-066790 are novel drugs that overcome some of PZQ limitations, and CIDD-0150303 can be used with PZQ in combination therapy.

59 BASIC BIOLOGICAL SCIENCES↗

Air Pathway Dose Modeling for the E-Area Low-Level Waste Facility

The US Department of Energy (DOE) Order 435.1 performance assessment (PA) process (USDOE 1999) prescribes a performance objective (10 mrem y -1 ) for evaluating atmospheric releases of radionuclides from DOE low-level waste (LLW) disposal facilities. The potential dose to an individual from exposure to radionuclides released into the atmosphere from LLW disposals can be estimated by application of radionuclide -specific dose-release factors (DRFs) (mrem Ci -1 ) to estimated flux rates (Ci y -1 ) at a particular time and location. In Revision 0 of this report, Lee (2006) calculated DRFs for potential atmospheric releases of 15 volatile radionuclides from seven ELLWF disposal units in support of the 2008 ELLWF PA (WSRC 2008). The mainframe version of the US Environmental Protection Agency’s (EPA) dose model CAP88 was used in the Revision 0 assessment. In Revision 1 of this report (Dixon and Minter 2017), the site-specific Savannah River National Laboratory (SRNL) atmospheric dose models MAXDOSE-SR version 2013 (Stone and Jannik 2013a) and MAXINE version 2017 (Bell 2017) were used to calculate DRFs for ten radionuclides. This work (Revision 2) supersedes Revision 0 (Lee 2006) and Revision 1 (Dixon and Minter 2017) of this report. The Revision 2 method for estimating new DRFs for the ELLWF disposal units is described in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Air Pathway Dose Modeling for the E-Area Low-Level Waste Facility

The US Department of Energy (DOE) Order 435.1 performance assessment (PA) process (USDOE 1999) prescribes a performance objective (10 mrem y -1 ) for evaluating atmospheric releases of radionuclides from DOE low-level waste (LLW) disposal facilities. The potential dose to an individual from exposure to radionuclides released into the atmosphere from LLW disposals can be estimated by application of radionuclide-specific dose-release factors (DRFs) (mrem Ci -1 ) to estimated flux rates (Ci y -1 ) at a particular time and location. In Revision 0 of this report, Lee (2006) calculated DRFs for potential atmospheric releases of 15 volatile radionuclides from seven ELLWF disposal units in support of the 2008 ELLWF PA (WSRC 2008). The mainframe version of the US Environmental Protection Agency’s (EPA) dose model CAP88 was used in the Revision 0 assessment. In Revision 1 of this report (Dixon and Minter 2017), the site-specific Savannah River National Laboratory (SRNL) atmospheric dose models MAXDOSE-SR version 2013 (Stone and Jannik 2013a) and MAXINE version 2017 (Bell 2017) were used to calculate DRFs for ten radionuclides. Revision 2 provided updated DRFs using the current version of the US Environmental Protection Agency’s (EPA) dose model CAP88-PC Version 4.1. After Revision 2 was finalized, DRFs were requested for Ar-37, Ar-39, Kr-83m, and Hg-206. Revision 3 provides the additional DRFs calculated using the same methods as used in Revision 2 of this document. The method for estimating new DRFs for the ELLWF disposal units is described in this report.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clinical 6 MV X-Ray Facility Photo-Neutron/Fission Interrogations with TMFD Sensors

Detection of several targets (U, Be, D2O) of interest to national security has been achieved at Purdue University’s 6 MV (~104 R/h) X-Ray clinical linear accelerator (CLINAC), from photoneutron/fission induced neutron signatures using a Centrifugally Tensioned Metastable Fluid Detector (CTMFD). Traditional neutron detection schemes were saturated and ineffective under the intense (to ~104 R/h) photon environment; however, the CTMFD sensor technology was capable of measuring the relatively insignificant (~10-12x lower intensity) neutron field produced from 6 MeV-end point X-Ray beam interactions with the CLINAC components and surroundings. This is in stark contrast to published results based on conventional belief for immeasurable neutron dose in 6 MV CLINAC facilities. Photoneutron and photofission neutron production rates were detected and analyzed at various standoffs from the isocenter, with and without special nuclear material (SNM) related targets ranging in mass from 5 g of Be, to ~0.6 kg of UO2. It was confirmed that 6 MV X-Ray photons do result in measurable neutron dose above normal cosmic background. Additionally, in threshold mode, the CTMFD operating under a tensioned metastable pressure of -5bar, enabled conclusive rejection of background photoneutrons, while enabling the rapid detection of: Be, D2O, C and U targets within seconds to minutes while operating in and around 104 R/h photon fields.

Ozerov, Stepan↗

Evaluation of planar silicon pixel sensors with the RD53A readout chip for the Phase-2 Upgrade of the CMS Inner Tracker

The Large Hadron Collider at CERN will undergo an upgrade inorder to increase its luminosity to7.5 × 10$^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosityduring this High-Luminosity running phase, starting around 2029,means a higher rate of proton-proton interactions, hence a largerionizing dose and particle fluence for the detectors. The currenttracking system of the CMS experiment will be fully replaced inorder to cope with the new operating conditions. Prototype planarpixel sensors for the CMS Inner Tracker with square50 μm × 50 μm and rectangular100 μm × 25 μm pixels read out by theRD53A chip were characterized in the lab and at the DESY-II testbeamfacility in order to identify designs that meet the requirements ofCMS during the High-Luminosity running phase. A spatial resolutionof approximately 3.4 μm (2 μm) is obtained using themodules with 50 μm × 50 μm(100 μm × 25 μm) pixels at the optimalangle of incidence before irradiation. After irradiation to a 1 MeVneutron equivalent fluence ofΦ$_{eq}$ = 5.3 × 10$^{15}$ cm$^{-2}$, a resolution of9.4 μm is achieved at a bias voltage of 800 V using a modulewith 50 μm × 50 μm pixel size. All modulesretain a hit efficiency in excess of 99% after irradiation tofluences up to 2.1 × 10$^{16}$ cm$^{-2}$. Further studies ofthe electrical properties of the modules, especially crosstalk, arealso presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstructed lung doses for the million person study cohort of 26,650 Tennessee Eastman corporation workers employed between 1942 and 1947

Abstract Tennessee Eastman Corporation workers were exposed to uranium dust resulting in high-linear energy transfer (LET) irradiation to lung tissue. In this work, radiation lung doses were reconstructed for 26 650 men and women working at the plant between 1942 and 1947. Site air monitoring data of uranium concentrations and payroll records were used to determine the daily inhaled activities and annualized lung doses. Variations in the activity median aerodynamic diameter of the uranium dust, the solubility of particulate matter in the lungs and the sex-specific breathing rate were investigated as part of a sensitivity analysis. Male and female mean lung doses of 18.9 and 32.7 mGy, respectively, from high-LET alpha irradiation, and there was general agreement with evaluations from previously published epidemiological studies. Annual lung dose estimates and sensitivity analysis for the 26 650 workers in the TEC cohort have been archived on the United States Department of Energy Comprehensive Epidemiologic Data Resource.