Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Mitigation of Acute Ammonia Emissions With Biochar During Swine Manure Agitation Before Pump-Out: Proof-of-the-Concept

Ammonia (NH 3 ) emissions from animal agriculture can cause eutrophication of water ecosystems and are precursors to secondary particulate matter (PM 2 .5 ). NH 3 emissions from stored swine manure represent nutrient loss affecting the fertilizing value of manure. The short-term emission bursts occur when farmers agitate manure before emptying storage and fertilizing fields. There is no proven technology to mitigate gaseous emissions during agitation, while the hazards of acute releases (e.g., H 2 S) are well-known. Biochar mitigates NH 3 emissions from manure over the long-term. The objective of this research was to evaluate the mitigation of acute NH 3 emissions during/after agitation. Two biochars, highly alkaline and porous (HAP from corn stover) and red oak (RO), were tested. The 6 and 12 mm-thick layers of biochar powder were surficial applied followed by 3 min agitation. NH 3 concentrations were measured before/during/after agitation. Mitigation was assessed by comparing: (i) the maximum (peak) flux, (ii) total emission (from agitation start till NH 3 concentration returned to the before-agitation), and (iii) the total emissions during agitation. The 12 mm HAP significantly ( p < 0.05) reduced (i–iii) by 63, 70, and 85%, respectively. The 6 mm HAP significantly reduced (i–iii) by 76, 75, and 78%, respectively. The 12 mm RO significantly reduced (i–iii) by 9, 53, and 57%, respectively. The 6 mm RO significantly reduced (i–iii) by 61, 86, and 63%, respectively. The NH 3 emission kinetics model confirmed that a 6 mm dose was just as effective as the larger dose. More research is needed to optimize and scale-up mitigating emissions and retention of nutrients in manure with biochar.

Chen, Baitong↗

ExpoKids: An R-based tool for characterizing aggregate chemical exposure during childhood

Background: Aggregate exposure, the combined exposures to a single chemical from all pathways, is a critical children’s health issue. Objective: The primary objective is to develop a tool to illustrate potential differences in aggregate exposure at various childhood lifestages and the adult lifestage. Methods: We developed ExpoKids (an R-based tool) using oral exposure estimates across lifestages generated by US EPA’s Exposure Factors Interactive Resource for Scenarios Tool (ExpoFIRST). Results: ExpoKids is applied to illustrate aggregate oral exposure, for ten media, as average daily doses (ADD) and lifetime average daily doses (LADD) in five graphs organized across seven postnatal childhood lifestages and the adult lifestage. This data visualization tool conveys ExpoFIRST findings, from available exposure data, to highlight the relative contributions of media and lifestages to chemical exposure. To evaluate the effectiveness of ExpoKids, three chemical case examples (di[2-ethylhexyl] phthalate [DEHP], manganese, and endosulfan) were explored. Data available from the published literature and databases for each case example were used to explore research questions regarding media and lifestage contributions to aggregate exposure. Significance: These illustrative case examples demonstrate ExpoKids’ versatile application to explore a diverse set of children’s health risk assessment and management questions by visually depicting specific media and lifestage contributions to aggregate exposure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Predicting oncology drug-induced cardiotoxicity with donor-specific iPSC-CMs—a proof-of-concept study with doxorubicin

Abstract Many oncology drugs have been found to induce cardiotoxicity in a subset of patients, which significantly limits their clinical use and impedes the benefit of lifesaving anticancer treatments. Human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) carry donor-specific genetic information and have been proposed for exploring the interindividual difference in oncology drug-induced cardiotoxicity. Herein, we evaluated the inter- and intraindividual variability of iPSC-CM-related assays and presented a proof of concept to prospectively predict doxorubicin (DOX)-induced cardiotoxicity (DIC) using donor-specific iPSC-CMs. Our findings demonstrated that donor-specific iPSC-CMs exhibited greater line-to-line variability than the intraindividual variability in impedance cytotoxicity and transcriptome assays. The variable and dose-dependent cytotoxic responses of iPSC-CMs resembled those observed in clinical practice and largely replicated the reported mechanisms. By categorizing iPSC-CMs into resistant and sensitive cell lines based on their time- and concentration-related phenotypic responses to DOX, we found that the sensitivity of donor-specific iPSC-CMs to DOX may predict in vivo DIC risk. Furthermore, we identified a differentially expressed gene, DND microRNA-mediated repression inhibitor 1 (DND1), between the DOX-resistant and DOX-sensitive iPSC-CMs. Our results support the utilization of donor-specific iPSC-CMs in assessing interindividual differences in DIC. Further studies will encompass a large panel of donor-specific iPSC-CMs to identify potential novel molecular and genetic biomarkers for predicting DOX and other oncology drug-induced cardiotoxicity.

Toxicology↗

Simultaneous Exposure of Cultured Human Lymphoblastic Cells to Simulated Microgravity and Radiation Increases Chromosome Aberrations

During space travel, humans are continuously exposed to two major environmental stresses, microgravity (μG) and space radiation. One of the fundamental questions is whether the two stressors are interactive. For over half a century, many studies were carried out in space, as well as using devices that simulated μG on the ground to investigate gravity effects on cells and organisms, and we have gained insights into how living organisms respond to μG. However, our knowledge on how to assess and manage human health risks in long-term mission to the Moon or Mars is drastically limited. For example, little information is available on how cells respond to simultaneous exposure to space radiation and μG. In this study, we analyzed the frequencies of chromosome aberrations (CA) in cultured human lymphoblastic TK6 cells exposed to X-ray or carbon ion under the simulated μG conditions. A higher frequency of both simple and complex types of CA were observed in cells exposed to radiation and μG simultaneously compared to CA frequency in cells exposed to radiation only. Our study shows that the dose response data on space radiation obtained at the 1G condition could lead to the underestimation of astronauts’ potential risk for health deterioration, including cancer. This study also emphasizes the importance of obtaining data on the molecular and cellular responses to irradiation under μG conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Radionuclide Inventory Threshold for Trench 31 and 34 Located Within the 200 West Area Low-Level Burial Grounds

Trenches 31 and 34 located in the 200 West Area Low-Level Burial Ground (LLBG) are authorized for disposal of low-level and mixed low-level radioactive waste under DOE Order 435.1, Radioactive Waste Management. A revised Disposal Authorization Statement was issued in October 2023 following approval of the performance assessment (PA) and supporting technical basis documents. To be consistent with approved PA calculations, the waste acceptance criteria (WAC) needs to be updated to include concentration limits for Category 1 (CAT1) and Category 3 (CAT3) waste along with the inventory limits. This environmental calculation file (ECF) provides the inventory limits for Category 1 and Category 3 waste disposal of radionuclides at Trench 31 and 34 based on the PA calculations. The concentration limits are not calculated as they are provided in the PA itself. The inventory thresholds (or limits) are calculated for only those radionuclides that are identified in the PA as the primary dose contributors. The primary dose contributors for the groundwater pathway are technetium-99, iodine-129, niobium-94, chlorine-36, molybdenum-93, and niobium-93m while those for the air pathway are tritium and carbon-14.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A New Shutdown Dose Rate Benchmark Problem for Representative Fusion Applications

Here, this work introduces a new benchmark problem for calculating shutdown dose rates (SDDRs) aimed at fusion reactor applications. The model is designed to represent a simplified version of a typical ITER port plug. The responses of interest include neutron flux, gamma flux, and gamma SDDR at 12 different locations scattered throughout the port. This article outlines the geometry specifications of the problem, provides material definitions for the components, specifies the required responses to be calculated, and presents the source definition information. The need for this benchmark arises from the limited availability of publicly accessible references, with only one benchmark representing the typical dimensions and materials found in fusion systems. This existing benchmark has been cited extensively, reflecting the demand within the scientific community to test both established and novel workflows for SDDR calculations. However, since its presentation at a conference in 2011, the results have become increasingly well known. Moreover, the absence of formal publication and peer review has led to the details of this benchmark being extracted from secondary sources, such as subsequent studies that reference it. As a result, analysts are left with significant flexibility in interpreting the key parameters, which can be adjusted to account for unknown systematic errors, ultimately reproducing the already well-known responses. This new benchmark serves as an updated version of that earlier work, with the aim of providing a more reliable description of the materials and their impurities, which is crucial for assessing activation and subsequent gamma emission. Additionally, it seeks to provide a geometry that more closely represents an ITER port plug. The improvements in the problem definition will lead to a more reproducible benchmark problem, while also presenting the radiation transport community with a completely new challenge. The results will be published in a future article to allow analysts adequate time to analyze this problem independently.

Benchmark↗

Back to functional hydrides: Effects of neutron-irradiated microstructure on hydrogen retention in yttrium hydride

Functional hydrides are promising candidates for advanced nuclear reactors, particularly in portable or transportable applications, due to their high hydrogen-retention capabilities, enabling efficient neutron moderation, and compact reactor design. However, hydrogen mobility in hydrides at elevated irradiation temperatures poses significant technological challenges, necessitating a comprehensive understanding of their irradiation behavior. Furthermore, this study investigated the microstructural and chemical stability of neutron-irradiated yttrium hydrides to assess their hydrogen-retention capacity. A targeted literature review was also conducted to contextualize neutron-irradiation effects on functional hydrides with regards to structural stability and hydrogen retention. Experimental characterizations revealed that, at high temperatures, irradiated hydrides retained their phase stability, which was likely enhanced by irradiation-induced microstructure evolution. Notably, an amorphous yttrium and oxygen -rich surface layer was present at the free surface of the hydride. Its thickness decreased while a continuous crystalline Y-O-rich layer was formed with increasing neutron damage. Additionally, the number density of dislocation loops and cavities generally increased as a function of neutron dose. First-principles calculations of hydrogen behavior within yttrium vacancy clusters in yttrium hydrides demonstrated vacancy-size-dependent hydrogen stability and configuration, highlighting the role of vacancy geometry in regulating hydrogen retention. Thus, the presence of irradiation-induced dislocation loops and cavities were hypothesized to improve hydrogen retention. Collectively, these findings advance the understanding of hydride behavior under neutron irradiation as well as their technological readiness for portable or transportable nuclear reactors.

Defect clusters↗

Assessment of thermal and radiation induced creep in the dual cooled lead lithium blanket

The creep in recently designed blanket for the fusion nuclear science facility is described by decomposing it into thermal, irradiation and cavity swelling creep. Initial estimates of thermal creep using elastic high temperature rules showed that the recent heat transfer improvements at the first wall (FW) is feasible, and the FW can withstand heat flux of 0.35 MW/m 2 at 3000 hrs without rupture. A viscoplastic model that is based on Norton's power law and relies on Multiphysics coupling of solid mechanics and heat transfer modules is used to capture the inelastic deformation in the blanket. Results showed that the design peak heat flux of 0.25 MW/m 2 produced maximum thermal creep strain of 0.45 % and the relaxation of the thermal stress at the FW. Irradiation creep is prescribed to be proportional to the displacement damage dose and applied stress. The displacements from irradiation creep radially decrease from the FW to the back wall, but the maximum deformation is found at the back wall that is connected to the Helium manifold due to the high stresses at the region. In conclusion, cavity swelling creep is dominant at steady state and combined with radiation creep to produce displacement of about 8 mm at the FW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of Baseline Monitoring Data for the Remote-Handled Low-Level Waste Disposal Facility at Idaho National Laboratory

The purpose of this document is to summarize environmental monitoring data collected at the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility during the first four years of facility operations (FY 2019 through FY 2022). This summary provides a “baseline” condition for the facility, which can be used to distinguish contaminant releases from the RHLLW Disposal Facility from pre existing contamination as well as potential future releases from other sources (i.e., upgradient aquifer sources), as specified in the facility monitoring plan. Sufficient data has been collected over the first four years of operation of the RHLLW Disposal Facility to establish baseline conditions for future compliance monitoring of aquifer wells and performance monitoring of vadose zone lysimeters. Except for seven elevated tritium measurements from lysimeter HFEF-South believed to have been impacted by waste disposals, all data was deemed appropriate for establishing baseline concentrations. Monitoring of the aquifer detected indicator analytes gross alpha and gross beta and target analytes tritium and C-14. There were a few C-14 detections prior to an increase in the required detection level (RDL) after the first round of sampling. I-129 and Tc-99 were not detected above RDLs in aquifer samples. Lysimeter samples detected indicator analytes gross alpha and gross beta and target analyte tritium. Target analytes C-14, I-129, and Tc-99 were not detected above RDLs in lysimeter samples. Except for tritium, baseline concentrations of indicator and target analytes measured during the first four years of RHLLW facility operations are expected to represent conditions through the expected 20 year operating period of the facility. Elevated tritium in the aquifer, a result of past discharges of tritium at upgradient facilities, showed a decline over the first four years of operations, and levels are expected to continue to decline with time as a result of dilution and decay. Current tritium levels in lysimeter samples may be elevated due to tritium in the water applied during construction and infiltration testing of the facility. As a result, tritium concentrations in lysimeters may decline with time as a result of dilution and decay. Statistical measures (i.e., mean, standard deviation, and 99% upper confidence level [UCL]) were calculated for all detected analytes using the four years of concentration data. These measures will be used to evaluate future monitoring results and to demonstrate the facility is performing, or not performing, as established in the facility performance assessment (PA). Future monitoring results will also be combined with the baseline data in this report to further establish temporal trends and natural variability in the measurements. Based on the data collected during the baseline period, it is recommended the gross alpha action level for performance monitoring increase from 10 to 20 pCi/L due to several baseline measurements exceeding the preliminary action level of 10. An action level of 20 pCi/L is slightly greater than the 99% UCL, is protective of the aquifer, and would reduce unnecessary sampling. It is also recommended that tritium be added to the lysimeter analyte list for post-baseline period monitoring. Tritium, while not a dose concern, is a good tracer that can provide valuable information on water flow in and around the RHLLW Disposal Facility. Recommendations for a tritium action level are provided if considered necessary.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Raman spectroscopy of neutron irradiated silicon carbide

The effects of neutron irradiation on microstructural evolution and the resultant changes in physical and mechanical properties are of critical importance for the development of silicon carbide (SiC) materials for nuclear applications. This study neutron-irradiated βSiC under a wide range of conditions at temperatures between 235 and 750°C and neutron doses of 0.01–11.8 displacements per atom, and then evaluated the effects on the SiC structure using Raman spectroscopy. The SiC optical phonon lines were shifted to lower wavenumbers by irradiation. Correlations were found among the wavenumber of the longitudinal optical phonon line, irradiation-induced swelling, and irradiation temperature. The peak shift also correlated indirectly with decreasing thermal conductivity of irradiated SiC. The irradiation-induced peak shift is explained by combinations of lattice strain, reduction of the elastic modulus, and other factors including decreasing coherent domain size. These findings bridge irradiation-induced microstructural changes and property changes and illustrate how Raman spectroscopy is a useful tool for nondestructively assessing irradiated SiC materials for nuclear applications.

Koyanagi, T.↗

HFIR SiC Bowing Test Ready to Insert

This report describes the successful assembly of a High Flux Isotope Reactor (HFIR) irradiation experiment designed to assess radiation-induced lateral bowing of silicon carbide fiber–reinforced, silicon carbide matrix composite (SiC/SiC) components under a radial fast neutron flux gradient. Excessive bowing of a SiC/SiC channel box in a boiling water reactor could potentially interfere with control blade movements. Similar concerns exist for SiC/SiC fuel cladding in light water reactors. The experiment described herein will provide experimental validation of the structural response of a miniature SiC/SiC channel box and tube specimens with pressurized water reactor diameters during irradiation. The significant radial fast neutron flux gradients that exist in the permanent reflector of HFIR were characterized using detailed three-dimensional neutronic calculations. The three-dimensional displacement damage dose rate profile and the resulting volumetric swelling in SiC were used as inputs to structural analyses that predicted the deformation and stresses in the channel box specimen. The specimens were thoroughly characterized prior to irradiation using traditional dimensional inspection and surface profilometry so that these measurements can later be compared with similar measurements that will be made post-irradiation to determine radiation-induced deformations. Furthermore, fine engraving markers were inscribed along all outer surfaces of the specimen and mapped using a digital microscope and a three-dimensional stage. This technique allowed for accurate measurements of the marker spacings, which can be compared with similar measurements that will be made post-irradiation to provide local radiation-induced strain mapping. The experiment was successfully assembled and is scheduled for insertion during HFIR cycle 492, which is currently scheduled to run from May 25, 2021 to June 18, 2021.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification and Validation of START: A Spent Nuclear Fuel Routing and Decision Support Tool

The Stakeholder Tool for Assessing Radioactive Transportation (START) is a web-based geospatial decision-support tool being developed by the US Department of Energy’s Office of Integrated Waste Management (IWM) to support federal interim storage for spent nuclear fuel (SNF) and associated transportation. START provides many functions for the IWM program including: serving as a communications tool for conveying geospatial data and information, an options analysis tool for exploring potential transport modes and routes for transporting SNF from nuclear power plants to future federal interim storage facilities, an emergency response planning tool for Tribes and States to identify training needs along potential SNF transport corridors, an environmental analysis tool for estimating potential radiation dose exposure from incident-free and incident-case SNF transport conditions, and a systems analysis support tool providing route-related inputs for system throughput analysis. As part of the START development process, a verification and validation (V&V) effort is being undertaken. In the initial V&V phase, several outputs of the START tool were checked such as the total distance, population and population densities within the buffer zone, and incident free dose. The V&V process is fluid as it will be utilized after each version change to ensure that the core functionalities of the tool are maintained and the results are consistent with the previous versions. Efforts have also been put into developing scripts to aid in the process of automating certain sections of the V&V work. As some of the V&V efforts use Environmental Systems Research Institute’s (ESRI) tools upon which the START framework is built, the START data were compared against outputs from tools like Quantum Geographic Information System (QGIS) for buffer zone populations and route lengths to ensure independence of the V&V process. Good agreement was observed between the START results and the independent V&V studies with the majority of the differences falling between 1% and 5% for populations within the buffer zone and route distance. This presentation describes the development and design of the START tool, V&V methods employed for various metrics of interest and their respective results, and future plans.

START, transportation, GIS, V&V↗

Update of Receptor Locations for INL National Emissions Standard for Hazardous Air Pollutants (NESHAP) Assessments

This report documents the selection of updated public receptor locations for use in conducting regulatory assessments of radioactive air emissions for Idaho National Laboratory (INL) facilities. The basis for this receptor location analysis is found in 40 CFR 61 Subpart H, “National Emissions Standards for Emissions of Radionuclide Other than Radon from Department of Energy Facilities,” where the requirements for identifying National Emission Standards for Hazardous Air Pollutants (NESHAP) receptor locations are outlined. Receptor locations (residences, schools, businesses, or farm operations) were identified using high-resolution satellite imagery. This assessment identified 31 unique receptor locations for all INL Site facilities, and 30 receptor locations for INL in-town facilities that have the potential to emit radioactive materials. Identification of receptors for each in-town facility is new to this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of time-resolved photoluminescence and deep-level transient spectroscopy defect evaluations in an InAs nBn detector subjected to in situ and ex situ 63 MeV proton irradiation

Deep-level transient spectroscopy and temperature-dependent time-resolved photoluminescence experiments are performed on identical InAs nBn photodetector structures as a function of in situ and ex situ 63 MeV proton irradiation to assess their generation and recombination dynamics. Pre-irradiation, the n-type InAs absorbing region, exhibits a steadily increasing minority carrier lifetime with increasing temperature, providing evidence that excited minority carriers may be recombining via shallow defect levels. From deep-level transient spectroscopy, two features are found between 10 and 275 K: a low temperature broad “shoulder,” which suggests emission from multiple shallow electron defect levels with energies <29 meV and a high temperature minimum occurring at ∼230 K with an activation energy of 539 meV, which suggests a defect in the barrier layer in the device. Two similar nBn detectors are then subjected to 63 MeV proton irradiation in step doses and measured between steps. One experiment is performed in situ with an nBn held at ∼10 K during dosing, and the other experiment is performed ex situ with a similar nBn held at room temperature for dosing. The ex situ dosing results in an evaluation of the defect introduction rate that is three to four times lower than in situ due to partial annealing of the proton-induced displacement damage at room temperature. The results of these two experiments are then compared with the dose-dependent recombination rate analysis, resulting in an estimated recombination defect cross section of 1.6 × 10 −13 cm 2 for the shallow shoulder defect.

Carrasco, Rigo A. [Air Force Research Laboratory (↗

Performance Assessment for the E-Area Low Level Radioactive Waste Disposal Facility at the Savannah River Site: Chapter 1

This report documents the revised Performance Assessment (PA) analysis for the E-Area Low-Level Waste Facility (ELLWF) at the United States (U.S.) Department of Energy (DOE) Savannah River Site (SRS). A PA analysis is required for DOE-operated facilities that dispose of low-level radioactive waste. PA analyses simulate (1) the release of radionuclides from the disposal site after facility closure, (2) transport of those contaminants through the environment, and (3) exposure/impacts to potential receptors. The purpose of the PA analysis is to demonstrate that the facility is operated in a manner that ensures long-term environmental protection after facility closure, thereby providing for the protection of public health and safety in limiting doses to a hypothetical member of the public (MOP) or an inadvertent human intruder (IHI). DOE Manual (M) 435.1-1, Chg. 3, Radioactive Waste Management (U.S. DOE, 2021b) establishes quantitative post-closure environmental impact limits and requires a facility-specific PA analysis to demonstrate compliance with these limits for DOE low-level waste (LLW) disposed of after September 26, 1988. These limits are defined in terms of human health (e.g., dose limits) with respect to radioactive constituents in the waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Statin Drug‐Drug Interactions: Pharmacokinetic Basis of FDA Labeling Recommendations and Comparison Across Common Tertiary Clinical Resources

Abstract Statins are widely prescribed and highly susceptible to pharmacokinetic (PK)‐based drug–drug interactions (DDIs). To date, there has not been a comprehensive analysis of the basis upon which statin DDI recommendations in US Food and Drug Administration (FDA) prescribing information (PI) are derived. We have conducted such an analysis. We also assessed the degree of concordance of statin DDI recommendations in FDA PI and those provided in common tertiary clinical resources. We catalogued statin DDI information, including PK data and management recommendations, for statin precipitant drugs approved from 2010 to 2021, available from FDA PI and tertiary clinical resource databases. Recommendations were categorized and mapped with associated PK data to assess consistency in the PK basis for labeling recommendations. From the 80 precipitant drugs evaluated, 180 statin DDIs were identified in FDA PI. Dedicated clinical DDI studies were conducted for 54% (n = 97) of these DDIs and 34% (n = 61) of DDI recommendations were extrapolated from clinical data with other statins. Overall, we found that PK‐based statin recommendations were consistent across PI. These findings highlight regulatory precedence for translating information across statins without conducting dedicated clinical DDI studies, which may support future efforts toward streamlining the approach to investigation and labeling of statin DDIs. In addition, with the exception of some notable discrepancies, general concordance was observed between FDA and tertiary resources regarding “Dose Adjustment” and “Avoid Coadministration” recommendations. However, further analyses are warranted across other DDI pairs to determine whether discordance can routinely lead to different clinical recommendations depending on the drug information resource.

Mease, James↗