Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Angular oversampling with temporally offset layers on multilayer detectors in computed tomography

Purpose: Today’s computed tomography (CT) scanners operate at an increasingly high rotation speed in order to reduce motion artifacts and to fulfill the requirements of dynamic acquisition, e.g., perfusion and cardiac imaging, with lower angular sampling rate as a consequence. In this paper, a simple method for obtaining angular oversampling when using multilayer detectors in continuous rotation CT is presented. Methods: By introducing temporal offsets between the measurement periods of the different layers on a multilayer detector, the angular sampling rate can be increased by a factor equal to the number of layers on the detector. The increased angular sampling rate reduces the risk of producing aliasing artifacts in the image. A simulation of a detector with two layers is performed to prove the concept. Results: The simulation study shows that aliasing artifacts from insufficient angular sampling are reduced by the proposed method. Specifically, when imaging a single point blurred by a 2D Gaussian kernel, the method is shown to reduce the strength of the aliasing artifacts by approximately an order of magnitude. Conclusions: The presented oversampling method is easy to implement in today’s multilayer detectors and has the potential to reduce aliasing artifacts in the reconstructed images.

60 APPLIED LIFE SCIENCES↗

Characterization and performance of the DTAS detector

DTAS is a segmented total absorption γ-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also under real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which is complicated by the effect of NaI(Tl) light-yield non-proportionality. The use of a system to correct for time variations of the gain in individual detector modules, based on a light pulse generator, is demonstrated. We describe also an event-based method to evaluate the summing-pileup electronic distortion in segmented spectrometers. All of this allows a careful characterization of the detector with Monte Carlo simulations that is needed to calculate the response function for the analysis of total absorption γ-ray spectroscopy data. In conclusion, special attention was paid to the interaction of neutrons with the spectrometer, since they are a source of contamination in studies of β-delayed neutron emitting nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Full Simulation of CMS for Run-3 and Phase-2

In this contribution we report the status of the CMS Geant4 simulation and the prospects for Run-3 and Phase-2. Firstly, we report about our experience during the start of Run-3 with Geant4 10.7.2, the common software package DD4hep for geometry description, and VecGeom runtime geometry library. In addition, FTFP_BERT_EMM Physics List and CMS configuration for tracking in magnetic field have been utilized. For the first time, for the Grid mass production of Monte-Carlo, this combination of components is used. Further simulation improvements are under development targeting Run-3 such as the switch to the new Geant4 11.1 in production, that provides several features important for the optimization of simulation, for example the new transportation process with built-in multiple scattering, neutron general process, custom tracking manager, G4HepEm sub-library, and others. We will present evaluation of various options, validation results, and the final choice of simulation configuration for 2023 production and beyond. The performance of the CMS full simulation for Run-2 and Run-3 will also be discussed. CMS development plan for the Phase-2 Geant4 based simulation is very ambitious, and it includes a new geometry description, physics, and simulation configurations. The progress on new detector descriptions and full simulation will be presented as well as the R&D in progress to reduce compute capacity needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-18A-08: Effect of Quantum Detection Efficiency and Energy Bin Selection On Contrast-To-Noise-Ratio for Energy-Resolved Photon-Counting Detectors

Purpose: Energy-resolved photon-counting detectors have the capability to discriminate photons according to their energies. By using optimal energy weighting factors, the contrast-to-noise-ratio (CNR) of the reconstructed image can be improved. In this work, we investigate how quantum detection efficiency (QDE) affects the determination of the optimal energy threshold bins, and therefore the CNR improvement of photon-counting detectors. Methods: In this simulation study a photon-counting detector, based on Silicon (Si), was investigated. A task-oriented algorithm was used to determine the optimal energy bin setting in order to maximize CNR. Projection-based and Image-based energy weighting techniques were implemented. A 13 mm PMMA phantom with two contrast materials, hydroxyapatite (HA) and iodine (I), at different concentrations (100, 200, and 300 mg/mL for HA and 2, 4, and 8 mg/mL for I) was used. TASMIP algorithm was used to generate the spectrum with 2.7 mm Al filter. Different tube voltages, number of energy bins, and bin widths were investigated. Different thicknesses of Si were also investigated to determine the QDE effect on CNR. Results: CNR increased as the detector material thickness increased until it reached 30 mm for Si thickness such that the CNR value was near to the value predicted by an ideal detector. Also, the results indicated that the improvement of CNR due to the QDE is task-dependent when comparing weighted images to photon-counting images. For hydroxyapatite the improvement is approximately 20%, whereas for iodine it is less than 10%. Conclusion: The results showed that the improvement of CNR for an energy-resolved photon-counting detector is highly task-dependent when QDE is taken into account.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulated Energy Response in a Multiplicity Detector

Neutron multiplicity analysis is used for many applications, including nonproliferation and criticality safety. Multiplicity detectors have advantages over total neutron counting as they provide the ability to assess both multiplication and mass in fissionable material. In addition, multiplicity detectors can generate real-time information, e.g., dose estimation. The ability to evaluate the detector efficiency in each application is of primary importance in producing meaningful analyses. Multiplicity detectors usually house 3 He tubes within a polyethylene moderator. If the tubes are located behind different thickness of polyethylene, they will have different energy responses. This paper assesses 3 He tube efficiency as a function of neutron energy for a specific multiplicity detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the automatic reconstruction of protons from simulated neutrino interactions in the ICARUS detector: study of the performance of track vs shower discrimination algorithms

ICARUS, Imaging Cosmic and Rare Underground Signals, is the far detector of the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). This program was born with the purpose of definitely explaining some anomalies in the field of neutrino oscillation physics, that can suggest the existence of a 4-type of neutrino: the sterile neutrino. It doesn’t interact directly with ordinary matter through the weak interaction, but we can observed the effect of its oscillation. In this chapter I will briefly observe: • the physics goals of the SBN Program; • the role of ICARUS as SBN far detector; • the detection technology.

43 PARTICLE ACCELERATORS↗

Simulation study of geometric shape factor approach to estimating earth emitted flux densities from wide field-of-view radiation measurements

A study was performed on the use of geometric shape factors to estimate earth-emitted flux densities from radiation measurements with wide field-of-view flat-plate radiometers on satellites. Sets of simulated irradiance measurements were computed for unrestricted and restricted field-of-view detectors. In these simulations, the earth radiation field was modeled using data from Nimbus 2 and 3. Geometric shape factors were derived and applied to these data to estimate flux densities on global and zonal scales. For measurements at a satellite altitude of 600 km, estimates of zonal flux density were in error 1.0 to 1.2%, and global flux density errors were less than 0.2%. Estimates with unrestricted field-of-view detectors were about the same for Lambertian and non-Lambertian radiation models, but were affected by satellite altitude. The opposite was found for the restricted field-of-view detectors.

Weaver, W. L.↗

Simulation and Measurement of the Qweak Main Detector Energy Sensitivity

The Qweak experiment in Hall C at Jefferson lab aims to make the first direct measurement of the weak charge of the proton with about 4{\%} overall uncertainty by measuring the parity violating asymmetry in elastic electron-proton scattering. Changes in helicity correlated beam properties create false asymmetries, particularly if the apparatus is misaligned. We measure and correct such false asymmetries, but also try to understand and reduce them where possible. This talk will emphasize simulations of the sensitivity of the main detector to energy jitter (the single largest correction!) and what the comparison to data tells us about our detector alignment.

Subedi, Adesh↗

Long-baseline neutrino oscillation physics potential of the DUNE experiment

The sensitivity of the Deep Underground Neutrino Experiment (DUNE) to neutrino oscillation is determined, based on a full simulation, reconstruction, and event selection of the far detector and a full simulation and parameterized analysis of the near detector. Detailed uncertainties due to the flux prediction, neutrino interaction model, and detector effects are included. DUNE will resolve the neutrino mass ordering to a precision of 5σ, for all δ CP values, after 2 years of running with the nominal detector design and beam configuration. It has the potential to observe charge-parity violation in the neutrino sector to a precision of 3σ (5σ) after an exposure of 5 (10) years, for 50% of all δ CP values. It will also make precise measurements of other parameters governing long-baseline neutrino oscillation, and after an exposure of 15 years will achieve a similar sensitivity to sin 2 2$θ_{13}$ to current reactor experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction of Charged Particle Tracks in Realistic Detector Geometry Using a Vectorized and Parallelized Kalman Filter Algorithm

One of the most computationally challenging problems expected for the High-Luminosity Large Hadron Collider (HL-LHC) is finding and fitting particle tracks during event reconstruction. Algorithms used at the LHC today rely on Kalman filtering, which builds physical trajectories incrementally while incorporating material e ects and error estimation. Recognizing the need for faster computational throughput, we have adapted Kalman-filterbased methods for highly parallel, many-core SIMD and SIMT architectures that are now prevalent in high-performance hardware. Previously we observed significant parallel speedups, with physics performance comparable to CMS standard tracking, on Intel Xeon, Intel Xeon Phi, and (to a limited extent) NVIDIA GPUs. While early tests were based on artificial events occurring inside an idealized barrel detector, we showed subsequently that our mkFit software builds tracks successfully from complex simulated events (including detector pileup) occurring inside a geometrically accurate representation of the CMS-2017 tracker. Here, we report on advances in both the computational and physics performance of mkFit, as well as progress toward integration with CMS production software. Recently we have improved the overall eciency of the algorithm by preserving short track candidates at a relatively early stage rather than attempting to extend them over many layers. Moreover, mkFit formerly produced an excess of duplicate tracks; these are now explicitly removed in an additional processing step. We demonstrate that with these enhancements, mkFit becomes a suitable choice for the first iteration of CMS tracking, and eventually for later iterations as well. We plan to test this capability in the CMS High Level Trigger during Run 3 of the LHC, with an ultimate goal of using it in both the CMS HLT and oine reconstruction for the HL-LHC CMS tracker.

Cerati, Giuseppe↗

Fast Simulation of the NICER Instrument

The NICER mission uses a complicated physical system to collect information from objects that are, by x-ray timing science standards, rather faint. To get the most out of the data we will need a rigorous understanding of all instrumental effects. We are in the process of constructing a very fast, high fidelity simulator that will help us to assess instrument performance, support simulation-based data reduction, and improve our estimates of measurement error. We will combine and extend existing optics, detector, and electronics simulations. We will employ the Compute Unied Device Architecture (CUDA2) to parallelize these calculations. The price of suitable CUDA-compatible multi-gigaflop cores is about $0.20/core, so this approach will be very cost-effective.

gEDA↗