Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Deployable Structure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Scanning Cloud Radar Observations at Azores: Preliminary 3D Cloud Products

The deployment of the Scanning W-Band ARM Cloud Radar (SWACR) during the AMF campaign at Azores signals the first deployment of an ARM Facility-owned scanning cloud radar and offers a prelude for the type of 3D cloud observations that ARM will have the capability to provide at all the ARM Climate Research Facility sites by the end of 2010. The primary objective of the deployment of Scanning ARM Cloud Radars (SACRs) at the ARM Facility sites is to map continuously (operationally) the 3D structure of clouds and shallow precipitation and to provide 3D microphysical and dynamical retrievals for cloud life cycle and cloud-scale process studies. This is a challenging task, never attempted before, and requires significant research and development efforts in order to understand the radar's capabilities and limitations. At the same time, we need to look beyond the radar meteorology aspects of the challenge and ensure that the hardware and software capabilities of the new systems are utilized for the development of 3D data products that address the scientific needs of the new Atmospheric System Research (ASR) program. The SWACR observations at Azores provide a first look at such observations and the challenges associated with their analysis and interpretation. The set of scan strategies applied during the SWACR deployment and their merit is discussed. The scan strategies were adjusted for the detection of marine stratocumulus and shallow cumulus that were frequently observed at the Azores deployment. Quality control procedures for the radar reflectivity and Doppler products are presented. Finally, preliminary 3D-Active Remote Sensing of Cloud Locations (3D-ARSCL) products on a regular grid will be presented, and the challenges associated with their development discussed. In addition to data from the Azores deployment, limited data from the follow-up deployment of the SWACR at the ARM SGP site will be presented. This effort provides a blueprint for the effort required for the development of 3D cloud products from all new SACRs that the program will deploy at all fixed and mobile sites by the end of 2010.

54 ENVIRONMENTAL SCIENCES↗

Advanced Structured Adsorbent Architectures for Transformative Carbon Dioxide Capture Performance (Final Report)

Svante is a world leader at using solid sorbents for low-cost Carbon Dioxide (CO 2 ) capture, a technology which is recognized as critical in meeting the dual mandates of energy security/reliability and the mitigation of man-made CO 2 emissions. Svante has been developing proprietary adsorbent material compositions, forming them into structured laminates, developing and optimizing process cycles, and system design for efficient capture of CO 2 from post-combustion flue gases of thermal power plants and industrial facilities. The deployment of first-generation CO 2 capture technology has been significantly hampered by high costs and energy penalties, among other barriers. Second generation CO 2 capture technologies (including the Mark I variant of Svante’s Veloxotherm™ adsorption-based technology), utilizing single adsorbent architecture, show promise for reducing the barriers to deploying CO 2 capture plants in commercially meaningful numbers. The objective of this project was to evaluate the Recipient’s transformational (Mark-II) VeloxoTherm™ Technology via the development and bench-scale testing of an advanced structured adsorbent, including novel Bi-layer, laminated adsorbent structures and segmented beds. Svante selected, synthesized, and characterized tailored solid adsorbents for computational modeling, advanced structured adsorbent development, process simulations, and dynamic bench scale (~1-10 kg/day CO 2 captured) testing using an existing single-bed VeloxoTherm™ Station (VTS) coupled with a natural gas-fired boiler. Segmented beds used the in-house, multi-bed Process Demonstration Unit (PDU) to demonstrate key performance indicators (KPIs), such as recovery, product purity, regeneration energy, and the integrated system's productivity in lifetime analysis. Segmented beds were used at a 1 tonne per day (TPD) unit at an industrial site to provide bench-scale validation of performance in an industrial setting. Svante was developing and optimizing the post-combustion CO 2 adsorption technology architectures, including the Bi-layer and segmented laminated adsorbent structure design, integrated rapid cycle temperature swing adsorption (RC-TSA) cycle, flow path architecture, and adsorbent bed construction and packaging (including gas porting) to progress towards achievement of DOE’s Transformational CO 2 Capture goals of 95% CO 2 purity and a cost of electricity at least 30% lower than a supercritical Pulverized Coal (PC) power plant with CO 2 capture, or approximately $30 per tonne of CO 2 captured ready for demonstration by 2030. The main requirements to reach the DOE target cost of carbon capture below $30/MT using Rapid-Cycling Temperature Swing Adsorption (RC-TSA) are as follows: (1) Increased capacity at different CO 2 concentrations, (2) Increased sorbents cycle life, (3) Increased O 2 resistance, and (4) Decreased steam requirement to extract 1 kg of CO 2 .

20 FOSSIL-FUELED POWER PLANTS↗

Regulation of Cathode Mass and Charge Transfer by Structural 3D Engineering for Protonic Ceramic Fuel Cell at 400 °C

Abstract Lowering the operating temperature (ideally below 400 °C) for solid oxide fuel cell (SOFC) technology deployment has been an important transition that introduces the benefit of reduced operational costs and system durability. However, the key technical issue limiting the transition is the sluggish cathodic performance, namely the oxygen reduction reaction (ORR) rate of the conventional sponge‐like cathode dramatically drops as the temperature reduces. In this paper, 3D engineering of a cathode is conducted on a protonic ceramic fuel cell to obtain an enhanced ORR between 400 and 600 °C. Compared with a cell using a conventional sponge‐like cathode, 3D engineering improves the cathode ORR by 41% at 400 °C with a peak power density of 0.410 W cm −2 . A phase field simulation is applied to assist the engineering by understanding the competition between the cathode mass and charge transfer with different cathode porosities. The results show that structural engineering of existing well‐developed cathodes is a simple and effective method to promote cathode ORR for low temperature SOFC by regulating the mass and charge transfer.

Bian, Wenjuan↗

Rooftop Solar Deployment, Potential Electricity Rate Impacts, and the Timing of Revisions to State Net Metering Policy

Most U.S. states require utilities to credit residential solar photovoltaic (PV) output at the retail electricity rate, a structure known as net metering. However, 12 states have replaced net metering with alternative rate structures that reduce PV adopter bill savings. The share of households living in states that require net metering fell from around 84% in 2014 to around 57% by the end of 2023. Proponents of net metering revisions have argued that net metering can affect the electricity rates of customers without PV. This report analyzes the relationships between state PV deployment levels, potential electricity rate impacts on PV nonadopters, and the timing of revisions to net metering policy.

14 SOLAR ENERGY↗

TEAMER: Triton Systems Oscillating Water Column Modeling Data and Report

This dataset provides the output of six Wave Energy Converter Simulator (WEC-Sim) simulations and accompanying documentation for the modeling of Triton Systems' oscillating water column (OWC) system at tank scale (validated using available data for tuning the model, Tests 1-2) and deployment scale (for which no validation data is available, Tests 4-6). Included are the output data in a MATLAB file structure, a comprehensive report on the modeling and design of the Triton OWC system, and a link to the WEC-Sim GitHub page. This work was supported by funding from TEAMER RFTS 5 (Request for Technical Support).

16 TIDAL AND WAVE POWER↗

Optimal Efficiency and Operational Cost Savings: A Framework for Automated Rooftop PV Placement

Residential energy consumers are charged based on a utility rate structure, such as net metering or feed-in tariff. To lower consumers' electricity bills, expensive batteries are deployed to reduce the electricity fed from the grid during peak hours. However, strategic photovoltaic (PV) panel placement enables the reduction of operational energy cost while considering the spatial feasibility and efficiency for hosting rooftop PV. In this paper, we present a framework to automatically identify the optimal location of rooftop PV panels on residential buildings. Our framework integrates multiple workflows, including energy and environmental simulation, parametric modeling, and optimization to identify the ideal location of PV panels to balance the demand and supply at a building and community scale. These workflows are linked using the Grasshopper plug-in for Rhinoceros CAD software. The framework includes two different workflows, each satisfying a target for optimal PV placement: (a) maximizing PV panel efficiency, where users aim to maximize energy generation, and (b) minimizing operational energy cost, where "best'' panels are selected considering utility rates for operational energy cost. Our framework is demonstrated in a residential community in Fort Collins, Colorado, to generate the optimal PV placement for each of the two aforementioned targets. Results from the two workflows are compared to illustrate the effect of PV location and orientation on solar energy production efficiency and operational energy cost. The developed workflows are introduced as tools within the Grasshopper plug-in to investigate the solar potential of rooftop PV panels while taking into account factors such as contextual shading, utility rate structures, and buildings' energy demand profiles.

30 DIRECT ENERGY CONVERSION↗

Geophysical monitoring using active seismic techniques at the Citronelle Alabama CO 2 storage demonstration site

Between August 2012 and September 2014, about 114,000 metric tonnes of CO 2 was captured from the coal-fired Plant Barry Power Station at Bucks Alabama and injected into the Paluxy Formation above the oil pool in the southeast unit of the Citronelle Oilfield. Various monitoring methods were deployed at land surface and in project wells to measure system performance, comply with permit requirements and test new and innovative monitoring tools. The monitoring program relied heavily on active seismic methods for subsurface imaging of geologic structure and time-lapse seismic techniques to track the CO 2 migration in the injection interval. Both conventional geophone/hydrophone and fiber-optic based Distributed Acoustic Sensing (DAS) arrays were deployed and tested, allowing a side by side comparison of the equipment and techniques. Geophysical imaging of the subsurface was successful using DAS in the offset vertical seismic profile (OVSP) survey configuration. A high resolution OVSP image of the subsurface was obtained in 2014 with DAS, which exceeded project expectations in comparison to a lower resolution image obtained in 2012 using a conventional 80-level geophone array. A time-lapse image of the redistribution of CO 2 after injection ended in September 2014 was obtained with two DAS OVSP surveys from June 2014 and December 2015, thus successfully demonstrating its proof-of-concept. Unfortunately, a pre-injection baseline survey with DAS, which was in its initial stage of technology development in 2012, did not have sufficient quality for use, making it difficult to interpret the acquired DAS time-lapse difference. Additional research in this area has since demonstrated the utility of time-lapse DAS OVSP. DAS data were also acquired during a cross-well seismic survey conducted in 2014. Unfortunately, the DAS technique was not success in the cross-well survey configuration because the system noise level was too high in the crosswell frequency output range (100–1200 Hz) of the piezoelectric source (increasing by a factor of ten compared to VSP frequency band). Additionally, the cross-well geometry causes sub-horizontal (broadside) incidence on the vertical DAS fiber cable, which is known to be problematic. Current research is focused on improving the DAS cable response to broadside acoustic energy. Time-lapse seismic surveys using commercially available conventional arrays were also acquired. In contrast to the DAS acquired data, the cross-well seismic results obtained with the conventional array was highly successful and clearly showed the CO 2 remained in zone at the end of injection. Time-lapse differencing of the OSVP surveys acquired with the conventional arrays proved to be inconclusive. Finally, changes in wellbore conditions between surveys and unavoidable changes in equipment (the array used for the baseline survey was retired) affected data quality, making it difficult to interpret the OVSP results.

58 GEOSCIENCES↗

Validating modern methods for impurity analysis in fluoride salts

Salt impurities directly affect degradation of structural materials in molten salt environments, so impurity quantification and analysis of salts is important for the deployment of next generation molten salt nuclear reactors. Despite the importance of moisture and other oxygen containing impurities, reliable methods of measuring these impurities are not well qualified or commonly used. Herein, we present two methods for analysis of oxygen content and one method for analysis of hydrogen content in fluoride salts demonstrated on two batches of LiF-NaF-KF (FLiNaK) salt with differing purity levels. The intentional addition of varying amounts of oxygen and hydrogen to the FLiNaK salt as internal standards produced a linear response using a commercial combustion analysis instrument, and measured amounts were consistent with the standards. Overall, these results indicate the technique is a valid method for measuring oxygen and hydrogen content in fluoride salts. Corrosion studies of 316H in FLiNaK revealed 5 times more mass loss in the salt containing more impurities including hydrogen and transition metals.

36 MATERIALS SCIENCE↗

Computational modeling of graphite degradation in molten salt reactors: Role of infiltration

Molten salt reactors (MSRs) often employ graphite as a moderator and reflector. An important challenge for deploying graphite in these reactors is that, due to limited experimental data, our understanding of graphite’s structural integrity in molten salt environments remains incomplete. Here, this study addresses heat generation from fuel-bearing salt that has infiltrated open pores in the graphite, driven primarily by pressure differentials. This is one of multiple identified physical and chemical mechanisms through which molten salt could potentially degrade graphite. Thermally driven stresses are quantified using the Molten-Salt Reactor Experiment (MSRE) graphite moderator elements as a case study. Finite element simulations predict stress distributions at varying infiltration levels, indicating that thermal stresses increase with higher infiltration. Rare-event simulations using the parallel subset simulation framework identify the combinations and corresponding ranges of input parameters that lead to stresses above a specified threshold. In particular, combinations involving high infiltration amounts, high power density, and low thermal conductivity tend to induce the highest stresses. Under the inputs and assumptions considered in this work, the magnitudes of the thermally driven stresses are quite low, with a very low likelihood of causing failure due to exceeding the graphite’s tensile strength. Additionally, rare-event simulations were performed for two more scenarios: a scaled-up moderator geometry and a localized hotspot in the original geometry. Both cases resulted in increased susceptibility to failure, though not to a detrimental extent. Furthermore, the combined effects of irradiation and infiltration-induced thermal stresses were evaluated. The results showed that thermal stresses from infiltration were negligible compared to those caused by irradiation. The findings of such a study are inherently component-specific, but the methodology presented here could be used for similar assessments of salt-infiltration effects in other graphite components.

36 - MATERIALS SCIENCE↗

Radiation Stability of Mixed Tin-Lead Halide Perovskites: Implications for Space Applications

Mixed organic-inorganic halide perovskite solar cells (PSCs) have received considerable attention in recent years for their impressive solar to electrical power efficiency gains and potentially lower material and processing costs for optoelectronic applications. In addition to terrestrial applications, PSCs are of interest to the space power markets for their low cost, low weight, adaptability to flexible architectures, and tolerance to high energy particle irradiation (mainly protons and electrons). Here we investigate the properties of mixed formamidinium-methylammonium tin-lead iodide (FASn)0.6(MAPb)0.4I3 perovskites which lower the lead content as well as the bandgap, making them attractive for the low bandgap absorber material in tandem PSCs. Through current density-voltage (JV) characterization at lower temperatures, majority carrier transport is hindered and a barrier to photogenerated carrier extraction is evident. This is attributed to the thermally induced change of the bandgap of the absorber layer relative to the energy selective contacts in the device. We find that although the architecture used here hinders the performance at temperatures below 225 K, the tolerance to high energy (3.7 MeV) protons is impressive, considerably out-performing commercially available thin-film CIGS. These results suggest further improvements to structural and interface stability as well as lightweight encapsulation could lead to all perovskite flexible tandem arrays deployed for power generation on missions to low Earth orbit, the moon, Mars, and beyond.

perovskite solar cells↗

A redox-active organic cation for safer high energy density Li-ion batteries

Ni-rich layered cathode materials are at the forefront to be deployed in high energy density Li-ion batteries for the automotive market. However, the intrinsic poor structural and interfacial stability during overcharging could trigger violent thermal failure, which severely limits their wide application. To protect the Ni-rich cathode from overcharging, we firstly report a redox-active cation, thioether-substituted diaminocyclopropenium, as an electrolyte additive to limit the cell voltage within the safe value during overcharging. The organic cation demonstrates a record-breaking electrochemical reversibility at ~4.55 V versus Li + /Li and solubility (0.5 M) in carbonate-based electrolyte. The protection capability of the additive was explored in two cell chemistries: a LiNi 0.8 Co 0.15 Al 0.05 O 2 /graphite cell and a LiNi 0.8 Co 0.15 Al 0.05 O 2 /silicon–graphene cell with areal capacities of ~2.2 mA h cm -2 and ~3 mA h cm -2 , respectively. With 0.2 M addition, the LiNi 0.8 Co 0.15 Al 0.05 O 2 /graphite cell survived 54 cycles at 0.2C with 100% overcharge. Moreover, the cell can carry an utmost 4.4 mA cm -2 (2C) with 100% overcharge and a maximum capacity of 7540% SOC at 0.2C.

25 ENERGY STORAGE↗

Deuterium Hugoniot: Pitfalls of thermodynamic sampling beyond density functional theory

Outstanding problems in the high-pressure phase diagram of hydrogen have demonstrated the need for more accurate ab initio methods for thermodynamic sampling. One promising method that has been deployed extensively above 100 GPa is coupled electron-ion Monte Carlo (CEIMC), which treats the electronic structure with quantum Monte Carlo (QMC). However, CEIMC predictions of the deuterium principal Hugoniot disagree significantly with experiment, overshooting the experimentally determined peak compression density by 7% and lower temperature gas-gun data by well over 20%. By deriving an equation relating the predicted Hugoniot density to underlying equation of state errors, we show that QMC and many-body methods can easily spoil the error cancellation properties inherent in the Rankine-Hugoniot relation, and very likely suffer from error addition. By cross validating QMC based on systematically improvable trial functions against post-Hartree-Fock many-body methods, we find that these methods introduce errors of the right sign and magnitude to account for much of the observed discrepancy between CEIMC and experiment. In conclusion, we stress that this is not just a CEIMC problem, but that thermodynamic sampling based on other many-body methods is likely to experience similar difficulties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Benchmarking density functionals for hydrogen-helium mixtures with quantum Monte Carlo: Energetics, pressures, and forces

An accurate understanding of the phase diagram of dense hydrogen and helium mixtures is a crucial component in the construction of accurate models of Jupiter, Saturn, and Jovian extrasolar planets. Though DFT based rst principles methods have the potential to provide the accuracy and computational e ciency required for this task, recent benchmarking in hydrogen has shown that achieving this accuracy requires a judicious choice of functional, and a quanti cation of the errors introduced. In this work, we present a quantum Monte Carlo based benchmarking study of a wide range of density functionals for use in hydrogen-helium mixtures at thermodynamic conditions relevant for Jovian planets. Not only do we continue our program of benchmarking energetics and pressures, but we deploy QMC based force estimators and use them to gain insights into how well the local liquid structure is captured by di erent density functionals. We nd that TPSS, BLYP and vdW-DF are the most accurate functionals by most metrics, and that the enthalpy, energy, and pressure errors are very well behaved as a function of helium concentration. Beyond this, we highlight and analyze the major error trends and relative di erences exhibited by the major classes of functionals, and estimate the magnitudes of these e ects when possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-EF-210-07: Development of a Minimally Invasive Photo Acoustic Imaging System for Early Prostate Cancer Detection

Purpose: The objective of this work is to design, implement and characterize a catheter-based ultrasound/photoacoustic imaging probe for early-diagnosis of prostate cancer and to aid in image-guided radiation therapy. Methods: The need to image across 6–10cm of tissue to image the whole prostate gland limits the resolution achievable with a transrectal ultrasound approach. In contrast, the urethra bisects the prostate gland, providing a minimally invasive pathway for deploying a high resolution ultrasound transducer. Utilizing a high-frequency (20MHz) ultrasound/photoacoustic probe, high-resolution structural and molecular imaging of the prostate tissue is possible. A custom 3D printed probe containing a high-frequency single-element ultrasound transducer is utilized. The diameter of the probe is designed to fit inside a Foley catheter and the probe is rotated around the central axis to achieve a circular B-scan. A custom ultrasound amplifier and receiver was set up to trigger the ultrasound pulse transmission and record the reflected signal. The reconstructed images were compared to images generated by traditional 5 MHz ultrasound transducers. Results: The preliminary results using the high-frequency ultrasound probe show that it is possible to resolve finely detailed information in a prostate tissue phantom that was not achievable with previous low-frequency ultrasound systems. Preliminary ultrasound imaging was performed on tissue mimicking phantom and sensitivity and signal-to-noise ratio of the catheter was measured. Conclusion: In order to achieve non-invasive, high-resolution, structural and molecular imaging for early-diagnosis and image-guided radiation therapy of the prostate tissue, a transurethral catheter was designed. Structural/molecular imaging using ultrasound/photoacoustic of the prostate tissue will allow for localization of hyper vascularized areas for early-stage prostate cancer diagnosis.

60 APPLIED LIFE SCIENCES↗

Multi-Sensor Estimation of Mixing Heights Over a Coastal City

An airborne Microwave Temperature Profiler (MTP) was deployed during the An airborne Microwave Temperature Profiler (MTP) was deployed during the Texas 2000 Air Quality Study (TexAQS-2000) to make measurements of boundary layer thermal structure. An objective technique is developed and tested for estimating the mixed layer (ML) height from the MTP vertical temperature profiles. The technique identifies the ML height as a threshold increase of potential temperature from its minimum value within the boundary layer. In order to calibrate the technique and evaluate the usefulness of this approach, coincident estimates from radiosondes, radar wind profilers, an aerosol backscatter lidar, and in situ aircraft measurements were compared with each other and with the MTP. Relative biases among all instruments were generally less than 50 m, and the agreement between MTP ML height estimates and other estimates was at least as good as the agreement among the other estimates. The ML height estimates from the MTP and other instruments are utilized to determine the spatial and temporal evolution of ML height in the Houston area on 1 Sept. 2000. An elevated temperature inversion was present, so ML growth was inhibited until early afternoon. In the afternoon, large spatial variations in ML height developed across the Houston area. The highest ML heights, well over 2 km, were observed to the north of Houston, while downwind of Galveston Bay and within the late afternoon sea breeze ML heights were much lower. The spatial variations that were found away from the immediate influence of coastal circulations were unexpected, and multiple independent ML height estimates were essential for documenting this feature.

54 ENVIRONMENTAL SCIENCES↗

Avoided electricity subsidy payments can finance substantial appliance efficiency incentive programs: Case study of Mexico

Numerous countries use taxpayer funds to subsidize residential electricity for a variety of socioeconomic objectives. These subsidies lower the value of energy efficiency to the consumer while raising it for the government. Further, while it would be especially helpful to have stringent Minimum Energy Performance Standards (MEPS) for appliances and buildings in this environment, they are hard to strengthen without imposing a cost on ratepayers. In this secondbest world, where the presence of subsidies limits the government’s ability to strengthen standards, we find that avoided subsidies are a readily available source of financing for energy efficiency incentive programs. Here, we introduce the LBNL Energy Efficiency Revenue Analysis (LEERA) model to estimate the appliance efficiency improvements that can be achieved in Mexico by the revenue neutral financing of incentive programs from avoided subsidy payments. LEERA uses the detailed techno-economic analysis developed by LBNL for the Super-efficient Equipment and Appliance Deployment (SEAD) Initiative to calculate the incremental costs of appliance efficiency improvements. We analyze Mexico’s tariff structures and the long-run marginal cost of supply to calculate the marginal savings for the government from appliance efficiency. We find that avoided subsidy payments alone can finance incentive programs that cover the full incremental cost of refrigerators that are 27% more efficient and TVs that are 32% more efficient than baseline models. We find less substantial market transformation potential for room ACs primarily because AC energy savings occur at less subsidized tariffs.

25 ENERGY STORAGE↗

Exotanium DOE SBIR Phase I Results Summary

Exotanium demonstrated this technology with the Idaho National Laboratory’s MASTODON application, a Multiphysics environment designed to run typical high-performance computing (HPC) simulations for structural dynamics, seismic analysis, and risk assessment. The MASTODON application was packaged into a container using Docker, Deployed on Amazon ECS, and managed through a custom Scale-Out Compute on AWS (SOCA) implementation.

97 MATHEMATICS AND COMPUTING↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗