Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Non-Uniform Dose Mapping Controlled by Modulated Vertical and Horizontal Scans

Since geometries of semi-conductor devices continue to shrink, the requirement for each process becomes severer to keep uniformity of electrical parameters of the semi-conductor devices. A larger wafer also causes larger variations. Thus it has been strongly required for ion implantation process to compensate for the variations from other processes because of its good dose controllability. A newly developed mapping of intentional non-uniform dosage system, which is named 'MIND system', is implemented in SEN's single-wafer-type implanters. The MIND system controls both horizontal and vertical scan speed simultaneously. Intentional two-dimensional non-uniform profiles of sheet resistance, such as concentric and eccentric profiles, are obtained only by single-step ion implantation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The change in permeability spectra due to ion irradiation in the Co-based amorphous ribbon

The Ar ion has been irradiated by an ion implanter with energy of 50, 70, and 100 keV and an ion dosage was set to 1.0x10{sup 17} ion/cm{sup 2} at a beam flux of 3.7 {mu}A/cm{sup 2}. The ion irradiation decreased the initial permeability and increased the relaxation frequency, and the behavior of permeability spectra due to ion irradiation was explained with damped harmonic model of domain wall on the general basis of magnetization mechanism. The ion irradiation gives rise to a significant change on the restoring force of domain wall but minor effect on the spin rotation. The enhancement in the permeability of the amorphous ribbon upon ion irradiation leads to a parallel improvement of giant magneto impedance response of the material, which is of practical use for sensing applications.

36 MATERIALS SCIENCE↗

Physical and Chemical Changes of Polystyrene Nanospheres Irradiated with Laser

It has been reported that polymer resist such as PMMA (Poly(methyl methacrylate) which is a well known and commonly used polymer resist for fabrication of electronic devices can show zwitter characteristic due to over exposure to electron beam radiation. Overexposed PMMA tend to changes their molecular structure to either become negative or positive resist corresponded to electron beam irradiation doses. These characteristic was due to crosslinking and scissors of the PMMA molecular structures, but till now the understanding of crosslinking and scissors of the polymer resist molecular structure due to electron beam exposure were still unknown to researchers. Previously we have over exposed polystyrene nanospheres to various radiation sources, such as electron beam, solar radiation and laser, which is another compound that can act as polymer resist. We investigated the physical and chemical structures of the irradiated polystyrene nanospheres with FTIR analysis. It is found that the physical and chemical changes of the irradiated polystyrene were found to be corresponded with the radiation dosages. Later, combining Laser irradiation and Reactive Ion Etching manipulation, created a facile technique that we called as LARIEA NSL (Laser and Reactive Ion Etching Assisted Nanosphere Lithography) which can be a facile technique to fabricate controllable carbonaceous nanoparticles for applications such as lithographic mask, catalysts and heavy metal absorbers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

1-D fluid model of atmospheric-pressure rf He+O{sub 2} cold plasmas: Parametric study and critical evaluation

In this paper atmospheric-pressure rf He+O{sub 2} cold plasmas are studied by means of a 1-D fluid model. 17 species and 60 key reactions selected from a study of 250+ reactions are incorporated in the model. O{sub 2}{sup +}, O{sub 3}{sup -}, and O are the dominant positive ion, negative ion, and reactive oxygen species, respectively. Ground state O is mainly generated by electron induced reactions and quenching of atomic and molecular oxygen metastables, while three-body reactions leading to the formation of O{sub 2} and O{sub 3} are the main mechanisms responsible for O destruction. The fraction of input power dissipated by ions is {approx}20%. For the conditions considered in the study {approx}6% of the input power is coupled to ions in the bulk and this amount will increase with increasing electronegativity. Radial and electrode losses of neutral species are in most cases negligible when compared to gas phase processes as these losses are diffusion limited due to the large collisionality of the plasma. The electrode loss rate of neutral species is found to be nearly independent of the surface adsorption probability p for p > 0.001 and therefore plasma dosage can be quantified even if p is not known precisely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma radiation induced degradation in PE-PP block copolymer

In the present investigation, effect of gamma irradiation on the PP-PE block copolymer has been studied. The polymer has been subjected to gamma irradiation from 100 to 500 Mrad dosages. Characterization of the polymer using XRD and FTIR was done both before irradiation and after irradiation in each step. Effect of irradiation on the electrical properties of the material has also been studied. FTIR study shows that the sample loses C - C stretching mode of vibration but gains C=C stretching mode of vibration after irradiation. Present investigation clearly indicates that though the electrical conductivity increases in the material, it undergoes degradation and shows brittleness due to irradiation.

36 MATERIALS SCIENCE↗

Characterization of irradiation damage distribution near TiO{sub 2}/SrTiO{sub 3} interfaces using coherent acoustic phonon interferometry

We apply ultrafast coherent acoustic phonon interferometry to characterize the distribution of the radiation damage near the TiO{sub 2}/SrTiO{sub 3} interfaces. We show that the optical and mechanical properties of anatase TiO{sub 2} remain unaffected by the radiation dosages in the 0.1 Division-Sign 5 dpa (displacements per atom) range, while the degraded optical response indicates a significant defect accumulation in the interfacial region of SrTiO{sub 3} at 0.1 dpa and subsequent amorphization at 3 dpa. Comparison between the theoretical simulations and the experimental results reveals an almost threefold reduction of the sound velocity in the irradiated SrTiO{sub 3} layer with peak damage levels of 3 and 5 dpa.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Suppression of shear banding in amorphous ZrCuAl nanopillars by irradiation

Using molecular dynamics simulations, model Zr{sub 50}Cu{sub 40}Al{sub 10} metallic glass (MG) nanopillars were subjected to simulated irradiation processes followed by uniaxial compression tests. As the intensity or dosage of irradiation increases, the plastic deformation mode of the MG nanopillars transits from localized shear banding to homogeneous shear flow. The suppression of shear banding in MG nanopillars is due to irradiation-induced structural disordering. Furthermore, a correlation is found between the average potential energy of MG nanopillars and their deformation modes, common to both irradiation processing and thermal processing. Our results imply that the homogeneous shear flow observed in experimental MG nanopillars carved by focused ion beam may be due to irradiation damage instead of size effect.

36 MATERIALS SCIENCE↗

Evolution of nanoripples on silicon by gas cluster-ion irradiation

Si wafers of (100), (110) and (111) orientations were bombarded by gas cluster ion beam (GCIB) of 3000 Ar-atoms/cluster on average at a series of angles. Similar surface morphology ripples developed in different nanoscales. A simple scaling functional satisfactorily describe the roughness and wavelength of the ripple patterns as a function of dosage and angle of incidence. The ripples are formed orthogonal to the incident cluster-ions at large off-normal angles. An ellipsoidal pattern was created by two consecutive irradiations incident in mutually orthogonal directions with unequal exposure times between each irradiation, from 7:1 to 10:1, beyond which the original ripple imprints would be over-written. This work was inspired by use of the ripples to seed growth of controlled nanostructures without patterning by lithography or predeposition of catalysts.

36 MATERIALS SCIENCE↗

Extreme ultraviolet induced defects on few-layer graphene

We use Raman spectroscopy to show that exposing few-layer graphene to extreme ultraviolet (EUV, 13.5 nm) radiation, i.e., relatively low photon energy, results in an increasing density of defects. Furthermore, exposure to EUV radiation in a H{sub 2} background increases the graphene dosage sensitivity, due to reactions caused by the EUV induced hydrogen plasma. X-ray photoelectron spectroscopy results show that the sp{sup 2} bonded carbon fraction decreases while the sp{sup 3} bonded carbon and oxide fraction increases with exposure dose. Our experimental results confirm that even in reducing environment oxidation is still one of the main source of inducing defects.

36 MATERIALS SCIENCE↗

Cavity morphology in a Ni based superalloy under heavy ion irradiation with hot pre-injected helium. II

In the current investigation, TEM in-situ heavy ion (1 MeV Kr{sup 2+}) irradiation with helium pre-injected at elevated temperature (400 °C) was conducted to simulate in-reactor neutron irradiation induced damage in CANDU spacer material Inconel X-750, in an effort to understand the effects of helium on irradiation induced cavity microstructures. Three different quantities of helium, 400 appm, 1000 appm, and 5000 appm, were pre-injected directly into TEM foils at 400 °C. The samples containing helium were then irradiated in-situ with 1 MeV Kr{sup 2+} at 400 °C to a final dose of 5.4 dpa (displacement per atom). Cavities were formed from the helium injection solely and the cavity density and size increased with increasing helium dosage. In contrast to previous heavy ion irradiations with cold pre-injected helium, heterogeneous nucleation of cavities was observed. During the ensuing heavy ion irradiation, dynamical observation showed noticeable size increase in cavities which nucleated close to the grain boundaries. A “bubble-void” transformation was observed after Kr{sup 2+} irradiation to high dose (5.4 dpa) in samples containing 1000 appm and 5000 appm helium. Cavity distribution was found to be consistent with in-reactor neutron irradiation induced cavity microstructures. This implies that the distribution of helium is greatly dependent on the injection temperature, and helium pre-injection at high temperature is preferred for simulating the migration of the transmutation produced helium.

36 MATERIALS SCIENCE↗

Microstructural, thermal and antibacterial properties of electron beam irradiated Bombyx mori silk fibroin films

The Bombyx mori silk fibroin (SF) films were prepared by solution casting method and the effects of electron beam on structural, thermal and antibacterial responses of the prepared films were studied. The electron irradiation for different doses was carried out using 8 MeV Microtron facility at Mangalore University. The changes in microstructural parameters and thermal stability of the films were investigated using Wide Angle X-ray Scattering (WAXS) and thermogravimetric analysis (TGA) respectively. Both microstructuralline parameters (crystallite size and lattice strain (g in %)) and thermal stability of the irradiated films have increased with radiation dosage. Agar diffusion method demonstrated the antibacterial activity of SF film which was increased after irradiation on both Gram-positive and Gram-negative species.

36 MATERIALS SCIENCE↗

Calibration and equivalency analysis of image plate scanners

A universal procedure was developed to calibrate image plate scanners using radioisotope sources. Techniques to calibrate scanners and sources, as well as cross-calibrate scanner models, are described to convert image plate dosage into physical units. This allows for the direct comparison of quantitative data between any facility and scanner. An empirical relation was also derived to establish sensitivity response settings for arbitrary gain settings. In practice, these methods may be extended to any image plate scanning system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple-robot drug delivery strategy through coordinated teams of microswimmers

Untethered robotic microswimmers are very promising to significantly improve various types of minimally invasive surgeries by offering high accuracy at extremely small scales. A prime example is drug delivery, for which a large number of microswimmers is required to deliver sufficient dosages to target sites. For this reason, the controllability of groups of microswimmers is essential. In this paper, we demonstrate simultaneous control of multiple geometrically similar but magnetically different microswimmers using a single global rotating magnetic field. By exploiting the differences in their magnetic properties, we triggered different swimming behaviors from the microswimmers by controlling the frequency and the strength of the global field, for example, one swim and the other does not while exposed to the same control input. Our results show that the balance between the applied magnetic torque and the hydrodynamic torque can be exploited for simultaneous control of two microswimmers to swim in opposite directions, with different velocities, and with similar velocities. This work will serve to establish important concepts for future developments of control systems to manipulate multiple magnetically actuated microswimmers and a step towards using swarms of microswimmers as viable workforces for complex operations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiosensitivity study and radiation effects on morphology characterization of grey oyster mushroom Pleurotus sajor-caju

Radiosensitive dosage and morphology characterization of irradiated grey oyster mushroom Pleurotus sajor-caju by gamma rays was investigated due to effects of irradiation. In order to establish the effect, mycelium of P. sajor-caju was irradiated by gamma rays at dose 0.1 to 8.0 kGy with dose rate 0.227 Gy sec{sup −1}. The irradiation of mycelia was carried out at the radiation facility in Malaysian Nuclear Agency. The radiosensitivity study was performed by evaluating the percentage of survival irradiated mycelia. The lethal dose of the mycelium P. sajor-caju was determined at 4.0 kGy and LD{sub 50} to be equal at 2.2 kGy. The radiation effects on morphology were evaluated based on growth rate of irradiated mycelia, mycelia types, colonization period on substrate, morphology of fruit bodies and yields. The results shown growth rate of irradiated mycelium was slightly lower than the control and decreased as the dose increased. Irradiation was found can induced the primordia formation on PDA and the BE of irradiated seed is higher than to control. The irradiation is proven to be useful for generating new varieties of mushroom with commercial value to the industry.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A microwave resonator for limiting depth sensitivity for electron paramagnetic resonance spectroscopy of surfaces

A microwave Surface Resonator Array (SRA) structure is described for use in Electron Paramagnetic Resonance (EPR) spectroscopy. The SRA has a series of anti-parallel transmission line modes that provides a region of sensitivity equal to the cross-sectional area times its depth sensitivity, which is approximately half the distance between the transmission line centers. It is shown that the quarter-wave twin-lead transmission line can be a useful element for design of microwave resonators at frequencies as high as 10 GHz. The SRA geometry is presented as a novel resonator for use in surface spectroscopy where the region of interest is either surrounded by lossy material, or the spectroscopist wishes to minimize signal from surrounding materials. One such application is in vivo spectroscopy of human finger-nails at X-band (9.5 GHz) to measure ionizing radiation dosages. In order to reduce losses associated with tissues beneath the nail that yield no EPR signal, the SRA structure is designed to limit depth sensitivity to the thickness of the fingernail. Another application, due to the resonator geometry and limited depth penetration, is surface spectroscopy in coating or material science. To test this application, a spectrum of 1.44 μM of Mg{sup 2+} doped polystyrene 1.1 mm thick on an aluminum surface is obtained. Modeling, design, and simulations were performed using Wolfram Mathematica (Champaign, IL; v. 9.0) and Ansys High Frequency Structure Simulator (HFSS; Canonsburg, PA; v. 15.0). A micro-strip coupling circuit is designed to suppress unwanted modes and provide a balanced impedance transformation to a 50 Ω coaxial input. Agreement between simulated and experimental results is shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemoradiotherapeutic wrinkled mesoporous silica nanoparticles for use in cancer therapy

Over the last decade, the development and application of nanotechnology in cancer detection, diagnosis, and therapy have been widely reported. Engineering of vehicles for the simultaneous delivery of chemo- and radiotherapeutics increases the effectiveness of the therapy and reduces the dosage of each individual drug required to produce an observable therapeutic response. We here developed a novel chemoradiotherapeutic 1,2-dioleoyl-sn-glycero-3-phosphocholine lipid coated/uncoated platinum drug loaded, holmium-containing, wrinkled mesoporous silica nanoparticle. The materials were characterized with TEM, FTIR, {sup 1}H NMR, energy dispersive x-ray, inductively coupled plasma-mass spectrometry, and zeta potential measurements. In vitro platinum drug release from both lipid coated and uncoated chemoradiotherapeutic wrinkled mesoporous silica are reported. Various kinetic models were used to analyze the release kinetics. The radioactivity of the chemoradiotherapeutic nanocarriers was measured after neutron-activation.

36 MATERIALS SCIENCE↗

Raman spectra and electron-phonon coupling in disordered graphene with gate-tunable doping

We report a Raman spectroscopy study of graphene field-effect transistors with a controlled amount of defects introduced in graphene by exposure to electron-beam irradiation. Raman spectra are taken at T = 8 K over a range of back gate voltages (V{sub g}) for various irradiation dosages (R{sub e}). We study effects in the Raman spectra due to V{sub g}-induced doping and artificially created disorder at various R{sub e}. With moderate disorder (irradiation), the Raman G peak with respect to the graphene carrier density (n{sub FE}) exhibits a minimum in peak frequency and a maximum in peak width near the charge-neutral point (CNP). These trends are similar to those seen in previous works on pristine graphene and have been attributed to a reduction of electron-phonon coupling strength (D) and removal of the Kohn anomaly as the Fermi level moves away from the CNP. We also observe a maximum in I{sub 2D}/I{sub G} and weak maximum in I{sub D}/I{sub G} near the CNP. All the observed dependences of Raman parameters on n{sub FE} weaken at stronger disorder (higher R{sub e}), implying that disorder causes a reduction of D as well. Our findings are valuable for understanding Raman spectra and electron-phonon physics in doped and disordered graphene.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct nano-patterning of graphene with helium ion beams

Helium ion microscopy (HIM) was used for direct nano-patterning of single-layer graphene (SLG) on SiO{sub 2}/Si substrates. This technique involves irradiation of the sample with accelerated helium ions (He{sup +}). Doses of 2.0 × 10{sup 16 }He{sup + }cm{sup −2} from a 30 kV beam induced a metal-insulator transition in the SLG. The resolution of HIM patterning on SLG was investigated by fabricating nanoribbons and nanostructures. Analysis of scanning capacitance microscopy measurements revealed that the spatial resolution of HIM patterning depended on the dosage of He{sup +} in a non-monotonic fashion. Increasing the dose from 2.0 × 10{sup 16} to 5.0 × 10{sup 16 }He{sup + }cm{sup −2} improved the spatial resolution to several tens of nanometers. However, doses greater than 1.0 × 10{sup 17 }He{sup + }cm{sup −2} degraded the patterning characteristics. Direct patterning using HIM is a versatile approach to graphene fabrication and can be applied to graphene-based devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗