Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes: Martha's Vineyard, Massachusetts
This report presents a cold climate project that examines the relationships among very energy efficient single-family residential thermal enclosures, room-to-room temperature variations, and simplified space conditioning systems. The project was developed, designed, and built by South Mountain Company and is located in West Tisbury, Massachusetts, on the island of Martha’s Vineyard. This project allowed investigators to compare room-to-room temperatures in four virtually identical houses that were all built to the same construction standard. Each of the four all-electric homes has a single ductless heat pump unit (DHU) located in the main living space with a single programmable thermostatic control built into the unit. Each bedroom and the main bathroom have radiant electric resistance panels with individual nonprogrammable thermostatic controls that occupants can turn on and off for their comfort. Results indicate that temperature fluctuations in the living room resulting from aggressive setup and setback of the DHU may contribute to fewer hours when the bedroom temperatures are within ±2°F of the living room temperatures, compared to houses without setback. Solar gains in the living room, along with opening and closing doors, appear to have a significant impact on room-to-room temperature differences, as would be expected. Setback strategies do not appear to save energy but do contribute to significant temperature variations.