Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computational Load Balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

An Effective Collaborative Mobile Weighted Clustering Schemes for Energy Balancing in Wireless Sensor Networks

Collaborative strategies for mobile sensor nodes ensure the efficiency and the robustness of data processing, while limiting the required communication bandwidth. In order to solve the problem of pipeline inspection and oil leakage monitoring, a collaborative weighted mobile sensing scheme is proposed. By adopting a weighted mobile sensing scheme, the adaptive collaborative clustering protocol can realize an even distribution of energy load among the mobile sensor nodes in each round, and make the best use of battery energy. A detailed theoretical analysis and experimental results revealed that the proposed protocol is an energy efficient collaborative strategy such that the sensor nodes can communicate with a fusion center and produce high power gain.

42 ENGINEERING↗

ASC ATDM Level 2 Milestone #5325: Asynchronous Many-Task Runtime System Analysis and Assessment for Next Generation Platforms

This report provides in-depth information and analysis to help create a technical road map for developing next-generation programming models and runtime systems that support Advanced Simulation and Computing (ASC) work- load requirements. The focus herein is on asynchronous many-task (AMT) model and runtime systems, which are of great interest in the context of "Oriascale7 computing, as they hold the promise to address key issues associated with future extreme-scale computer architectures. This report includes a thorough qualitative and quantitative examination of three best-of-class AIM] runtime systems – Charm-++, Legion, and Uintah, all of which are in use as part of the Centers. The studies focus on each of the runtimes' programmability , performance , and mutability . Through the experiments and analysis presented, several overarching Predictive Science Academic Alliance Program II (PSAAP-II) Asc findings emerge. From a performance perspective, AIV runtimes show tremendous potential for addressing extreme- scale challenges. Empirical studies show an AM runtime can mitigate performance heterogeneity inherent to the machine itself and that Message Passing Interface (MP1) and AM11runtimes perform comparably under balanced conditions. From a programmability and mutability perspective however, none of the runtimes in this study are currently ready for use in developing production-ready Sandia ASC applications. The report concludes by recommending a co- design path forward, wherein application, programming model, and runtime system developers work together to define requirements and solutions. Such a requirements-driven co-design approach benefits the community as a whole, with widespread community engagement mitigating risk for both application developers developers. and high-performance computing runtime systein

97 MATHEMATICS AND COMPUTING↗

Real-time supervisory control implementation of SmAHTR power plant - 143

This paper discusses an implementation of a supervisory control system for a nuclear power plant model using Small modular Advanced High Temperature Reactors (SmAHTR). The simulation operates in real-time using a network of computer agents, implemented on Raspberry Pi's (RPi's), where each major task is performed by one or more RPi's running calculations in parallel. The system architecture contains local, module, master, and operator actions to automate all aspects of the plant. Local level controllers run individual control loops to ensure the desired reference signals are met. The module level controllers set the local level reference signals within each SMR unit and detect sensor and actuator failures to adjust those reference signals as needed. Master level controllers balance plant power by calculating required heat power from each reactor and electric power from each generator and sending that data to the module controllers. Finally, the operator level contains an operator interface to summarize data and faults gathered through the controller levels, with options to review plant and reactor details as desired. This control implementation allows the plant to run autonomously, load follow a desired electrical power curve, and detect a growing number of fault scenarios. Ultimately, this type of supervisory control system will reduce labor-intensive surveillance and testing and allow fewer operators to more safely monitor an entire plant. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamic Economic Dispatch Considering Transmission–Distribution Coordination and Automatic Regulation Effect

With the rapid increase of renewable energy sources, the variability and uncertainty in power systems are significantly increased, and the power system operation is facing more and more challenges. In the traditional dynamic economic dispatch (DED) of transmission systems, the frequency and voltage regulation effects are not actively utilized. In addition, the transmission systems and distribution systems are optimized separately; the transmission–distribution coordination effect is not considered. In this article, a new DED is proposed. The optimal scheduling results are obtained by making a balance between operating cost and reliability cost. Both the automatic regulation effect and transmission–distribution coordination effect are explored and exploited in terms of the equivalent reserve, which can reduce the reserve provided by generating units, and can further enhance the security and economics of power system operation. The validity and effectiveness of the proposed model are illustrated by case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient packet forwarding using cyber-security aware policies

For balancing load, a forwarder can selectively direct data from the forwarder to a processor according to a loading parameter. The selective direction includes forwarding the data to the processor for processing, transforming and/or forwarding the data to another node, and dropping the data. The forwarder can also adjust the loading parameter based on, at least in part, feedback received from the processor. One or more processing elements can store values associated with one or more flows into a structure without locking the structure. The stored values can be used to determine how to direct the flows, e.g., whether to process a flow or to drop it. The structure can be used within an information channel providing feedback to a processor.

97 MATHEMATICS AND COMPUTING↗

Efficient packet forwarding using cyber-security aware policies

For balancing load, a forwarder can selectively direct data from the forwarder to a processor according to a loading parameter. The selective direction includes forwarding the data to the processor for processing, transforming and/or forwarding the data to another node, and dropping the data. The forwarder can also adjust the loading parameter based on, at least in part, feedback received from the processor. One or more processing elements can store values associated with one or more flows into a structure without locking the structure. The stored values can be used to determine how to direct the flows, e.g., whether to process a flow or to drop it. The structure can be used within an information channel providing feedback to a processor.

97 MATHEMATICS AND COMPUTING↗

Enabling Scalable and Extensible Memory-mapped Datastores in Userspace

Exascale workloads are expected to incorporate data-intensive processing in close coordination with traditional physics simulations. These emerging scientific, data-analytics and machine learning applications need to access a wide variety of datastores in flat files and structured databases. Programmer productivity is greatly enhanced by mapping datastores into the application process's virtual memory space to provide a unified “in-memory” interface. Currently, memory mapping is provided by system software primarily designed for generality and reliability. However, scalability at high concurrency is a formidable challenge on exascale systems. Also, there is a need for extensibility to support new datastores potentially requiring HPC data transfer services. In this article, we present UMap , a scalable and extensible userspace service for memory-mapping datastores. Furthermore, through decoupled queue management, concurrency aware adaptation, and dynamic load balancing, UMap enables application performance to scale even at high concurrency. We evaluate UMap in data-intensive applications, including sorting, graph traversal, database operations, and metagenomic analytics. Our results show that UMap as a userspace service outperforms an optimized kernel-based service across a wide range of intra-node concurrency by 1.22-1.9 × . We performed two case studies to demonstrate UMap 's extensibility. First, a new datastore residing in remote memory is incorporated into UMap as an application-specific plugin. Second, we present a persistent memory allocator Metall built atop UMap for unified storage/memory.

97 MATHEMATICS AND COMPUTING↗

Integrated Dynamic Facade Control with an Agent-based Architecture for Commercial Buildings

Dynamic façades have significant technical potential to minimize heating, cooling, and lighting energy use and peak electric demand in the perimeter zone of commercial buildings, but the performance of these systems is reliant on being able to balance complex trade-offs between solar control, daylight admission, comfort, and view over the life of the installation. As the context for controllable energy-efficiency technologies grows more complex with the increased use of intermittent renewable energy resources on the grid, it has become increasingly important to look ahead towards more advanced approaches to integrated systems control in order to achieve optimum life-cycle performance at a lower cost. This study examines the feasibility of a model predictive control system for low-cost autonomous dynamic façades. A system architecture designed around lightweight, simple agents is proposed. The architecture accommodates whole building and grid level demands through its modular, hierarchical approach. Automatically-generated models for computing window heat gains, daylight illuminance, and discomfort glare are described. The open source Modelica and JModelica software tools were used to determine the optimum state of control given inputs of window heat gains and lighting loads for a 24-hour optimization horizon. Penalty functions for glare and view/ daylight quality were implemented as constraints. The control system was tested on a low-power controller (1.4 GHz single core with 2 GB of RAM) to evaluate feasibility. The target platform is a low-cost ($35/unit) embedded controller with 1.2 GHz dual-core cpu and 1 GB of RAM. Configuration and commissioning of the curtainwall unit was designed to be largely plug and play with minimal inputs required by the manufacturer through a web-based user interface. An example application was used to demonstrate optimal control of a three-zone electrochromic window for a south-facing zone. The overall approach was deemed to be promising. Further engineering is required to enable scalable, turnkey solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasible Actuator Range Modifier (FARM), a Tool Aiding the Solution of Unit Dispatch Problems for Advanced Energy Systems

Integrated energy systems (IESs) seek to minimize power generating costs in future power grids through the coupling of different energy technologies. To accommodate fluctuations in load demand due to the penetration of renewable energy sources, flexible operation capabilities must be fully exploited, and even power plants that are traditionally considered as base-load units need to be operated according to unconventional paradigms. Thermomechanical loads induced by frequent power adjustments can accelerate the wear and tear. If a unit is flexibly operated without respecting limits on materials, the risk of failures of expensive components will eventually increase, nullifying the additional profits ensured by flexible operation. In addition to the bounds on power variations (explicit constraints),the solution of the unit dispatch problem needs to meet the limits on the variation of key process variables, including temperature, pressure and flow rate (implicit constraints).The FARM (Feasible Actuator Range Modifier) module was developed to enable existing optimization algorithms to identify solutions to the unit dispatch problem that are both economically favorable and technologically sustainable. Thanks to the iterative dispatcher–validator scheme, FARM permits addressing all the imposed constraints without excessively increasing the computational costs. In this work, the algorithms constituting the module are described, and the performance was assessed by solving the unit dispatch problem for an IES composed of three units, i.e., balance of plant, gas turbine, and high-temperature steam electrolysis. Finally, the FARM module provides dedicated tools for visualizing the response of the constrained variables of interest during operational transients and a tool aiding the operator at making decisions. These techniques might represent the first step towards the deployment of an ecological interface design (EID) for IES units.

47 OTHER INSTRUMENTATION↗

OctoFAS: A Two-Level Fair Scheduler That Increases Fairness in Network-Based Key-Value Storage

We identified a fairness problem in a network-based key-value storage system using Intel Storage Performance Development Kit (SPDK) in a multitenant environment. In such an environment, each tenant’s I/O service rate is not fairly guaranteed compared to that of other tenants. To address the fairness problem, we propose OctoFAS, a two-level fair scheduler designed to improve overall throughput and fairness among tenants. The two-level scheduler of OctoFAS consists of (i) inter-core scheduling and (ii) intra-core scheduling. Through inter-core scheduling, OctoFAS addresses the load imbalance problem that is inherent in SPDK on the storage server by dynamically migrating I/O requests from overloaded cores to underloaded cores, thereby increasing overall throughput. Intra-core scheduling prioritizes handling requests from starving tenants over well-fed tenants within core-specific event queues to ensure fair I/O services among multiple tenants. OctoFAS is deployed on a Linux cluster with SPDK. Through extensive evaluations, we found that OctoFAS ensures that the total system throughput remains high and balanced, while enhancing fairness by approximately 10% compared to the baseline, when both scheduling levels operate in a hybrid fashion.

97 MATHEMATICS AND COMPUTING↗

The Transactive Energy Network Template Metamodel

While transactive energy, which is defined as an allocation of electricity based on dynamically discovered values or prices, has been extensively studied, its uptake and use has been slow. This report describes a tool, the transactive network template, which should hasten the creation and uptake of transactive energy networks. Some basic principles of transactive energy are familiar from existing wholesale electricity markets. Locational prices are calculated today for zones within bulk electric transmission systems. Locational prices differ while accounting for the locational costs of electricity generation and the losses and constraints incurred when electricity is transmitted from generators and distributed to consumers. A transactive energy network might include these transmission zones. However, current research strives to apply transactive energy also in electricity distribution circuits, buildings, and even for individual generating and consuming devices. At the same time, researchers explore how to apply transactive energy in real time during increasingly shorter time intervals. Automated computational agents become necessary as transactive energy becomes applied to smaller circuit zones and at faster dynamic timescales. A transactive energy network is an example of a multi-agent system. Each zone in the network is represented by its transactive agent, which makes decisions for and acts on behalf of a business entity that is responsible for and manages one of the circuit regions. A transactive energy network is also an example of a decentralized, distributed control system. Control decisions and responsibilities are distributed among the network’s transactive agents. The transactive agents are independent; that is, there typically is no centralized authority or oversight function. Instead, transactive agents exchange transactive signals and thereby negotiate the prices and quantities of electricity that they will exchange. Initially, the circuit regions and responsibilities of transactive agents appear to be very dissimilar. Each circuit region may comprise transmission, distribution, or building-level circuits. Each has a unique position and electrical connectivity within the transactive energy network. Each possesses unique assets that either generate or consume electricity, and these (e.g., renewable energy generator, diesel generator, aggregate utility load, building load, space conditioning, refrigerator, etc.) may further differ in their price flexibility and in their strategies for responding to dynamic electricity prices. Given such diversity, an implementer’s first inclination might be to start from scratch to define all these devices and to engineer their seemingly unique interactions. Given that each implementer’s perspective may be narrow within a transactive energy network, it is unlikely that uniquely engineered systems would interact well. This is where the transactive network template is applicable. The transactive network template is a metamodel that has been developed to guide implementers as they configure their own transactive agent within a network of such agents. The object-oriented design of the transactive network template provides basic code object types that may be used and extended by implementers to represent each of the assets in their circuit region. These objects further facilitate the transactive agent’s necessary computations, which are divided among responsibilities to schedule power usage, balance electric supply and demand, and coordinate the exchange of electricity with the other transactive agents. This report addresses the conceptual transactive network template design. Implementers are directed to more formal design documents and reference implementations. A Python™-based1 reference implementation of the transactive network template has been coded, and three implementations have been configured to represent a national laboratory and two university campuses. Version 2 of the transactive node template generalizes the market class and its methods to facilitate multiple, and more diverse market coordination mechanisms than were facilitated by and demonstrated using Version 1. Version 3 includes new Appendix B, which addresses the designs of methods that would make dynamic prices track approved electricity rates. In the future, the author wishes to make the transactive network template more generally applicable to networks that require more accurate power flow. Development of the transactive network template is jointly funded by the U.S. Department of Energy (DOE) Energy Efficiency and Renewable Energy and the DOE Office of Electricity. In late 2015, one of the first projects to be funded by the DOE Grid Laboratory Modernization Laboratory Consortium was the Clean Energy and Transactive Campus project, led by Pacific Northwest National Laboratory. DOE funds were matched by an investment by the Washington Department of Commerce through its Clean Energy Fund. The transactive network template was developed to guide the implementation of transactive energy networks within this project’s scope.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MPACT Development Activities at University of Michigan

This report documents the efforts of general development tasks in MPACT performed primarily at the University of Michigan during FY17. These tasks included: 1. Unstructured CMFD - The unstructured CMFD supports the RIA and BWR challenge problems. It allows MPACT to simulate mixed lattice cores (e.g. 8x8 next to 9x9). This design feature is common to operating BWRs and also the SPERT experiments being used to validate VERA-CS for RIA. 2. Higher order spatial sources for MOC - The higher order sources are for improving the overall performance of MPACT. Higher order spatial sources in MOC provide accurate solutions with potentially significantly fewer mesh regions, thus speeding up every calculation. This method is also particularly important for BWRs. 3. Improving fine source region visualization - The improvement of the visualization of the flat source region mesh in MPACT is to support users and communication of models and results from MPACT. VERAView provides visualization of pin-wise information, however MPACT resolves the spatial solution to intra pin level. The capability provided here will let users visualize the full model geometry and components of the solution at the highest spatial resolution available from MPACT. 4. Automated spatial decomposition - The automated spatial decomposition removes the burden from the user to know how to spatially decompose the model for MPACT; a task that has been rather tricky in the past. Instead the user may give some number of processors that is a multiple of the axial mesh and MPACT will determine a nearly optimal decomposition that gives better load balance than most decompositions used currently. 5. Optimal relaxation factors for feedback - The development of optimal relaxation factor is to improve the stability and robustness of problems with feedback. Presently the default feedback values are 0.5, which may or may not be optimal. Without relaxation the fixed point iteration that is currently used is known to be unstable for large problems. The optimal relaxation factors are derived by utilizing a previous Fourier analysis. From the original milestone there was a scope change where the work on the Intel MIC was deferred for work on the automated spatial decomposition.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hardware Architectures for Data-Intensive Computing Problems: A Case Study for String Matching

DNA analysis is an emerging application of high performance bioinformatic. Modern sequencing machinery are able to provide, in few hours, large input streams of data, which needs to be matched against exponentially growing databases of known fragments. The ability to recognize these patterns effectively and fastly may allow extending the scale and the reach of the investigations performed by biology scientists. Aho-Corasick is an exact, multiple pattern matching algorithm often at the base of this application. High performance systems are a promising platform to accelerate this algorithm, which is computationally intensive but also inherently parallel. Nowadays, high performance systems also include heterogeneous processing elements, such as Graphic Processing Units (GPUs), to further accelerate parallel algorithms. Unfortunately, the Aho-Corasick algorithm exhibits large performance variability, depending on the size of the input streams, on the number of patterns to search and on the number of matches, and poses significant challenges on current high performance software and hardware implementations. An adequate mapping of the algorithm on the target architecture, coping with the limit of the underlining hardware, is required to reach the desired high throughputs. In this paper, we discuss the implementation of the Aho-Corasick algorithm for GPU-accelerated high performance systems. We present an optimized implementation of Aho-Corasick for GPUs and discuss its tradeoffs on the Tesla T10 and he new Tesla T20 (codename Fermi) GPUs. We then integrate the optimized GPU code, respectively, in a MPI-based and in a pthreads-based load balancer to enable execution of the algorithm on clusters and large sharedmemory multiprocessors (SMPs) accelerated with multiple GPUs.

Tumeo, Antonino↗

2007 Wholesale Power Rate Case Initial Proposal : Wholesale Power Rate Development Study.

The Wholesale Power Rate Development Study (WPRDS) calculates BPA proposed rates based on information either developed in the WPRDS or supplied by the other studies that comprise the BPA rate proposal. All of these studies, and accompanying documentation, provide the details of computations and assumptions. In general, information about loads and resources is provided by the Load Resource Study (LRS), WP-07-E-BPA-01, and the LRS Documentation, WP-07-E-BPA-01A. Revenue requirements information, as well as the Planned Net Revenues for Risk (PNNR), is provided in the Revenue Requirement Study, WP-07-E-BPA-02, and its accompanying Revenue Requirement Study Documentation, WP-07-E-BPA-02A and WP-07-E-BPA-02B. The Market Price Forecast Study (MPFS), WP-07-E-BPA-03, and the MPFS Documentation, WP-07-E-BPA-03A, provide the WPRDS with information regarding seasonal and diurnal differentiation of energy rates, as well information regarding monthly market prices for Demand Rates. In addition, this study provides information for the pricing of unbundled power products. The Risk Analysis Study, WP-07-E-BPA-04, and the Risk Analysis Study Documentation, WP-07-E-BPA-04A, provide short-term balancing purchases as well as secondary energy sales and revenue. The Section 7(b)(2) Rate Test Study, WP-07-E-BPA-06, and the Section 7(b)(2) Rate Test Study Documentation, WP-07-E-BPA-06A, implement Section 7(b)(2) of the Northwest Power Act to ensure that BPA preference customers firm power rates applied to their general requirements are no higher than rates calculated using specific assumptions in the Northwest Power Act.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SWIM: A Switch Manager for Datacenter Networks

As modern datacenter networks (DCNs) grow to support hundreds of thousands of servers and beyond, managing network equipment - such as routers, firewalls, and load balancers - becomes increasingly complex. Network attributes such as IP address allocations and BGP neighbor relations are scattered among various network engineering groups, which makes troubleshooting the network a cumbersome task. In addition, network vendor diversity leads to an explosion of vendor-specific management systems or single-use automation scripts, limiting network scalability while increasing the time required to perform management tasks. In this article, the authors propose a unified network management system, Switch Manager (SWIM), to cope with the growth by standardizing the language for describing network attributes and unifying the interface for executing management actions on the network equipment.

97 MATHEMATICS AND COMPUTING↗

Assessment of Model-Based Schemes for Accelerating Optimization by RAVEN

Nuclear-Renewable Hybrid Energy Systems (N-R HES) combine different energy technologies in a synergistic way with the objective of achieving a more economical energy production. In this report the particular hybrid system dealt with includes a PWR nuclear reactor, the associated Rankine-based energy conversion cycle (Balance of Plant, BOP), an Industrial Process (IP) for hydrogen production, a gas turbine (Second Energy Source, SES), and a battery (Energy Storage, ES). The RAVEN-based HYBRID framework is used to find the optimal installed capacity and the optimal economical dispatch of each component of the N-R HES. HYBRID solves the coupled capacity planning-economic and dispatch optimization problem with the objective of minimizing the Levelized Cost of Electricity (LCOE). In the optimization of the power dispatch strategy, the HYBRID framework takes into account the time-dependent dynamics of each subsystem by including a Dymola object-oriented model of the process dynamics. To ease the computational burden of the optimization process, an initial guess for the dispatch optimization problem is provided by a preconditioner. The solution guess is calculated by means of a least-marginal cost approach which applies the same criterion behind the screening curve method. Though this algorithm allows evaluating an economically adapted generation mix for a target load duration curve within a few seconds, it neglects the constraints due to the single component dynamics, and it is not able to adequately represent the ES. An improved treatment of the pre-conditioner problem was addressed by introducing a Monte Carlo based optimization algorithm. The new approach takes into account limits on power rates for the system subcomponents, which was not previously done. Additionally, this new Monte-Carlo based preconditioner addresses the problem with the ES component through improved modeling of that component. The new algorithm has been implemented in the HYBRID framework and tested to assess its performance. The results obtained with the new Monte Carlobased preconditioner were benchmarked against those obtained through the reference deterministic approach. The comparison shows that the Monte-Carlo based approach provides improved solution accuracy to the power dispatch optimization problem. Also in this report, the treatment of the penalty function on LCOE is discussed, and an improved penalty function for missed demand is suggested and tested.

Maronati, Giovanni↗

Nanoparticle O–H Bond Dissociation Free Energies from Equilibrium Measurements of Cerium Oxide Colloids

A novel equilibrium strategy for measuring the hydrogen atom affinity of colloidal metal oxide nanoparticles is presented. Reactions between oleate-capped cerium oxide nanoparticle colloids (nanoceria) and organic proton-coupled electron transfer (PCET) reagents are used as a model system. Nanoceria redox changes, or hydrogen loadings, and overall reaction stoichiometries were followed by both 1 H NMR and X-ray absorption near-edge spectroscopies. Furthermore, these investigations revealed that, in many cases, reactions between nanoceria and PCET reagents reach equilibrium states with good mass balance. Each equilibrium state is a direct measure of the bond strength, or bond dissociation free energy (BDFE), between nanoceria and hydrogen. Further studies, including those with larger nanoceria, indicated that the relevant bond is a surface O–H. Thus, we have measured surface O–H BDFEs for nanoceria—the first experimental BDFEs for any nanoscale metal oxide. Remarkably, the measured CeO–H BDFEs span 13 kcal mol –1 (0.56 eV) with changes in the average redox state of the nanoceria colloid. Possible chemical models for this strong dependence are discussed. We propose that the tunability of ceria BDFEs may be important in explaining its effectiveness in catalysis. More generally, metal oxide BDFEs have been used as predictors of catalyst efficacy that, traditionally, have only been accessible by computational methods. These results provide important experimental benchmarks for metal oxide BDFEs and demonstrate that the concepts of molecular bond strength thermochemistry can be applied to nanoscale materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large-scale frictionless jamming with power-law particle size distributions

Due to significant computational expense, discrete element method simulations of jammed packings of size-dispersed spheres with size ratios greater than 1:10 have remained elusive, limiting the correspondence between simulations and real-world granular materials with large size dispersity. Here, invoking a recently developed neighbor binning algorithm, we generate mechanically stable jammed packings of frictionless spheres with power-law size distributions containing up to nearly 4 000 000 particles with size ratios up to 1:100. By systematically varying the width and exponent of the underlying power laws, we analyze the role of particle size distributions on the structure of jammed packings. The densest packings are obtained for size distributions that balance the relative abundance of large-large and small-small particle contacts. Although the proportion of rattler particles and mean coordination number strongly depend on the size distribution, the mean coordination of nonrattler particles attains the frictionless isostatic value of six in all cases. The size distribution of nonrattler particles that participate in the load-bearing network exhibits no dependence on the width of the total particle size distribution beyond a critical particle size for low-magnitude exponent power laws. This signifies that only particles with sizes greater than the critical particle size contribute to the mechanical stability. However, for high-magnitude exponent power laws, all particle sizes participate in the mechanical stability of the packing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗