Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Collective motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Surface and Buried Thermal, and RGB Unexploded Ordnance Data Collection

This document provides a description of a data collection campaign of unexploded ordnance (UXOI) set. The dataset captures a controlled UAV imaging campaign designed to support detection of UXO across varied environmental conditions. Data were collected during three campaigns in Norris and Northeast Knoxville, Tennessee, using RGB, and thermal sensors mounted on Parrot UKR. In total, the dataset contains 9925 images, 26 full-motion video, and approximately 81.99 GB of data, collected across late spring/summer conditions, every hour during sunlight, and multiple surface contexts, including tall grass, short grass, gravel, as well as buried in sand, and other gravel mixtures. The collection was designed to capture thermal and visual variability relevant to UXO detection in agricultural land, bare earth, and subsurface. Review of the imagery showed that ordnance was most detectable during periods of changing solar input, especially approximately 10-60 minutes after sunrise, approximately 20-60 minutes after sunset, and 2-3 min after cloud cover interrupted prolonged solar heating. These conditions increased thermal contrast because many ordnance items retained or released heat differently than the surrounding vegetation and ground surface. This dataset provides a useful resource for developing and evaluating airborne UXO detection methods under realistic field conditions. All ordnance used in the study was inert, and thermal behavior may differ from that of live ordnance. In addition, variation in ordnance type, composition, and placement introduced differences in thermal response that should be considered when interpreting results.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Bessel Tube to Capture Lunar Volatiles

Current arts to create linear motion or acceleration of fine particles and molecules into devices such as mass spectrometers and vacuum pumps rely on the pressure difference created by a pinhole or mechanical processes. However, in an environment of vacuum, these approaches do not create such a pressure differential to drive and move fine particles and molecules. In some cases, electrostatic or magnetic processes may work to create the desired motion. A cylindrical harmonic of electric field, which is widely used in electron accelerators, offers a unique capability to capture and induce a linear motion of molecules and particles when electrically charged. Generally, lunar volatiles are electrostatically charged. The idea to capture and collect the lunar volatiles by creating a drift axis of motion using a cylindrical harmonic field has led to the development of a device concept, called a Bessel Tube. The Bessel Tube concept ingests fine particles, gaseous atoms, and gaseous molecules and guides them along an extraction tube for collection, separation, and analysis. The Bessel Tube concept for lunar volatile collection is discussed.

Bessel Tube↗

The Interstellar Gas Experiment: Analysis in progress

The Interstellar Gas Experiment (IGE) exposed thin metallic foils aboard the LDEF spacecraft in low Earth orbit in order to collect neutral interstellar particles which penetrate the solar system due to their motion relative to the sun. By mechanical penetration these atoms were imbedded in the collecting foils along with precipitating magnetospheric ions and, possibly, with ambient atmospheric atoms. During the entire LDEF mission, seven of these foils collected particles arriving from seven different directions as seen from the spacecraft. After the foils were returned to Earth, a mass spectrometric analysis of the noble gas component of the trapped particles was begun. The isotopes of He-3, He-4, Ne-20, and Ne-22 were detected. We have given a first account of the experiment. In order to infer the isotopic ratios in the interstellar medium from the concentrations found in the foils, several lines of investigation had to be initiated. The flux of ambient atmospheric noble gas atoms moving toward the foils due to the orbital motion of LDEF was estimated by detailed calculations. Any of these particles which evaded the baffles in the IGE collector could be entrapped in the foils as a background flux. However, the calculations have shown that this flux is negligible, which was the intent of the experiment hardware design. This conclusion is supported by the measurements. However, both the concentration of trapped helium and its impact energy indicate that the flux of magnetospheric ions which was captured was larger than had been expected. In fact, it appears that the magnetospheric particles constitute the largest fraction of the particles in the foils. Since little is known about this particle flux, their presence in the IGE foils appears fortunate. The analysis of these particles provides information about their isotropic composition and average flux.

Buehler, F.↗

Toward A Method for Scaling Human Body Models in an IMU-Based Workflow

- Scaled biomechanical models can more accurately inform crew health decisions when tailored to the wide range of astronaut sizes. One component to improve scaling of existing models to better represent each unique astronaut’s size is the individual length scaling of limbs. Traditionally, limb lengths are determined by motion capture or manual measurement. - A new method is herein proposed for length scaling which can be done by measuring linear and angular accelerations at a desired point during isolated motion around a point of rotation, then calculating the distance between the desired point and point of rotation. - When an Inertial Measurement Unit (IMU) device is placed at the distal point of a limb, the isolated motion is about that limb’s proximal joint. This method of scaling limb segments can be used for any limb that has an easily defined proximal joint for the limb to rotate around including hands, arms, legs, feet. - Calculated limb lengths are then used to scale models to each unique astronaut’s size, thereby improving the applicability of the model. - This method was investigated as a possible away to obtain scaling information in data collections where IMUs are worn, but optical motion capture may not always be available, such as inside spacesuits or during crew exercise on the International Space Station.

E. K. Marecki↗

Molecular rotation and reorientation - Microscopic and hydrodynamic contributions

The relative roles of microscopic and hydrodynamic contributions to molecular rotation and reorientation are examined within the framework of the microscopic boundary layer theory recently proposed by the authors. The theory is applied to rough spheres, for which computer simulation data are available and to experimental results on spherical top molecules. Attention is focused on rotational diffusion constants, the kappa parameter introduced by Kivelson et al., and orientational relaxation times. It is shown that, while collective effects are present and often nonnegligible, the motion of small molecules is dominated by its microscopic aspects. Experimental trends which can incorrectly suggest dominance by hydrodynamic contributions are discussed in some detail. Finally, the transition to the regime where collective effects are dominant is considered.

Hynes, J. T.↗

Replacing missing data between airborne SAR coherent image pairs

For synthetic aperture radar systems, missing data samples can cause severe image distortion. When multiple, coherent data collections exist and the missing data samples do not overlap between collections, there exists the possibility of replacing data samples between collections. For airborne radar, the known and unknown motion of the aircraft prevents direct data sample replacement to repair image features. Finally, this paper presents a method to calculate the necessary phase corrections to enable data sample replacement using only the collected radar data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Motility of Synthetic Cells from Engineered Lipids

Synthetic cells are artificial systems that resemble natural cells. Significant efforts have been made over the years to construct synthetic protocells that can mimic biological mechanisms and perform various complex processes. These include compartmentalization, metabolism, energy supply, communication, and gene reproduction. Cell motility is also of great importance, as nature uses elegant mechanisms for intracellular trafficking, immune response, and embryogenesis. In this review, we discuss the motility of synthetic cells made from lipid vesicles and relevant molecular mechanisms. Synthetic cell motion may be classified into surface-based or solution-based depending on whether it involves interactions with surfaces or movement in fluids. Collective migration behaviors have also been demonstrated. The swarm motion requires additional mechanisms for intercellular signaling and directional motility that enable communication and coordination among the synthetic vesicles. In addition, intracellular trafficking for molecular transport has been reconstituted in minimal cells with the help of DNA nanotechnology. These efforts demonstrate synthetic cells that can move, detect, respond, and interact. Finally, we envision that new developments in protocell motility will enhance our understanding of biological processes and be instrumental in bioengineering and therapeutic applications.

59 BASIC BIOLOGICAL SCIENCES↗

SU-F-T-560: Measurement of Dose Blurring Effect Due to Respiratory Motion for Lung Stereotactic Body Radiation Therapy (SBRT) Using Monte Carlo Based Calculation Algorithm

Purpose: Intra-fractional tumor motion due to respiration may potentially compromise dose delivery for SBRT of lung tumors. Even sufficient margins are used to ensure there is no geometric miss of target volume, there is potential dose blurring effect may present due to motion and could impact the tumor coverage if motions are larger. In this study we investigated dose blurring effect of open fields as well as Lung SBRT patients planned using 2 non-coplanar dynamic conformal arcs(NCDCA) and few conformal beams(CB) calculated with Monte Carlo (MC) based algorithm utilizing phantom with 2D-diode array(MapCheck) and ion-chamber. Methods: SBRT lung patients were planned on Brainlab-iPlan system using 4D-CT scan and ITV were contoured on MIP image set and verified on all breathing phase image sets to account for breathing motion and then 5mm margin was applied to generate PTV. Plans were created using two NCDCA and 4-5 CB 6MV photon calculated using XVMC MC-algorithm. 3 SBRT patients plans were transferred to phantom with MapCheck and 0.125cc ion-chamber inserted in the middle of phantom to calculate dose. Also open field 3×3, 5×5 and 10×10 were calculated on this phantom. Phantom was placed on motion platform with varying motion from 5, 10, 20 and 30 mm with duty cycle of 4 second. Measurements were carried out for open fields as well 3 patients plans at static and various degree of motions. MapCheck planar dose and ion-chamber reading were collected and compared with static measurements and computed values to evaluate the dosimetric effect on tumor coverage due to motion. Results: To eliminate complexity of patients plan 3 simple open fields were also measured to see the dose blurring effect with the introduction of motion. All motion measured ionchamber values were normalized to corresponding static value. For open fields 5×5 and 10×10 normalized central axis ion-chamber values were 1.00 for all motions but for 3×3 they were 1 up to 10mm motion and 0.97 and 0.87 for 20 and 30mm motion respectively. For SBRT plans central axis dose values were within 1% upto 10mm motions but decreased to average of 5% for 20mm and 8% for 30mm motion. Mapcheck comparison with static showed penumbra enlargement due to motion blurring at the edges of the field for 3×3,5×5,10×10 pass rates were 88% to 12%, 100% to 43% and 100% to 63% respectively as motion increased from 5 to 30mm. For SBRT plans MapCheck mean pass rate were decreased from 73.8% to 39.5% as motion increased from 5mm to 30mm. Conclusion: Dose blurring effect has been seen in open fields as well as SBRT lung plans using NCDCA with CB which worsens with increasing respiratory motion and decreasing field size(tumor size). To reduce this effect larger margins and appropriate motion reduction techniques should be utilized.

60 APPLIED LIFE SCIENCES↗

Modified Autogenic Feedback Training Produces Effect on Motion Sickness

Motion sickness is a common physiological reaction to provocative motion and is characterized by a constellation of symptoms, including stomach awareness, nausea, emesis, pallor, sweating, hypersalivation, and fatigue. The emergence of these symptoms can pose a significant threat to safety, particularly in the context of aviation. Given its prevalence among aviators and its detrimental impact on performance, researchers have endeavored to identify effective countermeasures for motion sickness. Currently, many of the existing interventions are pharmacological in nature and while effective, they present a problem due to their associated adverse side effects. A modified two-hour version of Autogenic Feedback Training Exercise (AFTE) could be an effective countermeasure to motion sickness without adverse side effects. AFTE combines principles of autogenic therapy, biofeedback, and learning to teach individuals to control their own internal physiological reactions through a series of relaxation and arousal exercises. AFTE was administered over six days. On the first day, participants were exposed to provocative motion via a rotating chair test to collect baseline physiological data. AFTE sessions were conducted on four consecutive days and lasted approximately 30 minutes each session. Participants were exposed to the rotating chair again on the 6th day. Results: Participants (n = 16) were evaluated on the number of rotations experienced and cumulative minutes spun in the chair. Participants tended to ride longer (M = 21.0 min, SD = 16.56) and tolerated more rotations (M = 244.8 rotations, SD = 310.62) on their second rotating chair test compared to baseline (M = 14.0 min, SD = 9.35; M = 125.8 rotations, SD = 124.08; t(15) = 2.21, p = .02). A moderate effect size was recorded (Hedges’s g = 0.44). A modified two-hour version of the AFTE is effective at increasing tolerance of symptoms associated with motion sickness.

motion sickness↗

Dynamic crystallography reveals spontaneous anisotropy in cubic GeTe

Cubic energy materials such as thermoelectrics or hybrid perovskite materials are often understood to be highly disordered. In GeTe and related IV–VI compounds, this is thought to provide the low thermal conductivities needed for thermoelectric applications. Since conventional crystallography cannot distinguish between static disorder and atomic motions, we develop the energy-resolved variable-shutter pair distribution function technique. This collects structural snapshots with varying exposure times, on timescales relevant for atomic motions. In disagreement with previous interpretations, we find the time-averaged structure of GeTe to be crystalline at all temperatures, but with anisotropic anharmonic dynamics at higher temperatures that resemble static disorder at fast shutter speeds, with correlated ferroelectric fluctuations along the <100> c direction. We show that this anisotropy naturally emerges from a Ginzburg–Landau model that couples polarization fluctuations through long-range elastic interactions. By accessing time-dependent atomic correlations in energy materials, we resolve the long-standing disagreement between local and average structure probes and show that spontaneous anisotropy is ubiquitous in cubic IV–VI materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The multiple applications of electrons in space

An electron source such as a simple cathode is a cheap and light device which can serve several technological and scientific purposes in space: (1) electrostatic charging of a spacecraft can be limited by releasing electrons accumulated on the conductive elements of their surface; (2) the erosion of conductive coatings and the ability of conductive paints to withstand the space environment can be evaluated by monitoring the flow of charged particles impinging on their surface; (3) measuring the current collected by the spacecraft surface as a function of its potential with respect to an emitter is a very sensitive diagnostic technique which can yield a number of plasma parameters, such as density and temperature; (4) it is possible to convert the thermal motion of space plasmas into electrical energy by collecting energetic electrons and returning them to the medium as cold particles; (5) a wave in a plasma is characterized by a conduction current density which gives rise to fluctuations of the current flowing to the surface.

Grard, R. J. L.↗

Exact methods for self interacting neutrinos

The effective many-body Hamiltonian which describes vacuum oscillations and self interactions of neutrinos in a two flavor mixing scheme under the single angle approximation has the same dynamical symmetries as the well known BCS pairing Hamiltonian. These dynamical symmetries manifest themselves in terms of a set of constants of motion and can be useful in formulating the collective oscillation modes in an intuitive way. In particular, we show that a neutrino spectral split can be simply viewed as an avoided level crossing between the eigenstates of a mean field Hamiltonian which includes a Lagrange multiplier in order to fix the value of an exact many-body constant of motion. We show that the same dynamical symmetries also exist in the three neutrino mixing scheme by explicitly writing down the corresponding constants of motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic cellular finite-element method for modelling large-scale cell migration and proliferation under the control of mechanical and biochemical cues: a study of re-epithelialization

Computational modelling of cells can reveal insight into the mechanisms of the important processes of tissue development. However, current cell models have limitations and are challenged to model detailed changes in cellular shapes and physical mechanics when thousands of migrating and interacting cells need to be modelled. In this paper we describe a novel dynamic cellular finite-element model (DyCelFEM), which accounts for changes in cellular shapes and mechanics. It also models the full range of cell motion, from movements of individual cells to collective cell migrations. The transmission of mechanical forces regulated by intercellular adhesions and their ruptures are also accounted for. Intra-cellular protein signalling networks controlling cell behaviours are embedded in individual cells. We employ DyCelFEM to examine specific effects of biochemical and mechanical cues in regulating cell migration and proliferation, and in controlling tissue patterning using a simplified re-epithelialization model of wound tissue. Our results suggest that biochemical cues are better at guiding cell migration with improved directionality and persistence, while mechanical cues are better at coordinating collective cell migration. Finally and overall, DyCelFEM can be used to study developmental processes when a large population of migrating cells under mechanical and biochemical controls experience complex changes in cell shapes and mechanics.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental and theoretical study of the plasma physics of antihydrogen generation and trapping. Final Scientific Report

The main goal of the project was to determine if matter and antimatter are exact conjugates. According to the current best understanding of the universe, this property should hold. The ALPHA collaboration performed a series of high precision measurements on trapped antihydrogen and compared the results to those that would be expected for hydrogen. Any difference would have enormous implications for our understanding of basic physics because a difference would mean the CPT theorem is violated. In pursuit of this goal, we needed to understand plasma and atomic processes for a novel set of plasma parameters: extremely low temperature (a few 10's of K) and high magnetic field (a couple T). Our attempts to control/manipulate these plasmas led to important goals related directly to plasma physics. For example, the radiative coupling of the cyclotron motion to a microwave cavity can display collective effects as the number of positrons increases. This DOE award mainly provided support for theoretical studies of the atomic and plasma processes that determine the outcome of the experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visualization of the laminar-turbulent transition in the flow over an airfoil using the smoke-wire technique

A flow visualization technique, referred to as the smoke-wire, was used for visualization of the transition of the free shear layer associated with the laminar separation bubble of a NACA 66 sub 3-018 airfoil section at low Reynolds number (50,000-130,000). The smoke-wire technique allows the introduction of fine smoke streaklines into the flow field through the electrical resistive heating of a very fine wire which has been coated with oil and which is located upstream from the leading edge of the airfoil section. Streakline data were collected using both high speed still and motion picture photography.

Batill, S. M.↗

Gradiometry coexperiments to the gravity probe B and step missions

The Gravity Probe-B (GP-B) spacecraft, designed to test predictions of general relativity, will fly in the mid 1990s. It will carry four electrostatically suspended gyroscopes in a cryogenic environment and will have a drag-free control system to minimize disturbances on the gyroscopes. The Stanford Test of Equivalence Principle (STEP) spacecraft, to fly later, will carry a set of test masses under very similar conditions. The possibility of using differential measurements of the GP-B gyroscopes suspension forces and the STEP tests mass displacement readout to form single-axis gravity gradiometers is explored. It is shown that the noise in the suspension systems is sufficiently small in the relevant frequency range, and that enough information is collected to compensate for the spacecrafts' attitude motion. Finally, using Breakwell's flat-earth approximation, these experiments are compared to other geodesy experiments and predict the contribution they can make to the knowledge of the Earth's geopotential.

Tapley, M.↗

The interstellar gas experiment

The Interstellar Gas Experiment (IGE) exposed thin metallic foils to collect neutral interstellar gas particles. These particles penetrate the solar system due to their motion relative to the sun. Thus, it is possible to entrap them in the collecting foils along with precipitating magnetospheric and perhaps some ambient atmospheric particles. For the entire duration of the Long Duration Exposure Facility (LDEF) mission, seven of these foils collected particles arriving from seven different directions as seen from the spacecraft. In the mass spectroscopic analysis of the noble gas component of these particles, we have detected the isotopes of He-3, He-4, Ne-20, and Ne-22. In the foil analyses carried out so far, we find a distribution of particle arrival directions which shows that a significant part of the trapped particles are indeed interstellar atoms. The analysis needed to subtract the competing fluxes of magnetospheric and atmospheric particles is still in progress.

Lind, D. L.↗