Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Charge coupled devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

The prototype MOSAIC detector

The prototype of the MOSAIC (Mosaicked Optical Self-scanned Array Imaging Camera) system, a photon-counting detector designed for use in the far ultraviolet, is described. MOSAIC has a two-dimensional format of 2400 x 2400 pixels, and is easily expandable. Readout is accomplished electronically via charge-coupled devices, making possible remote observations. Preliminary results of computer simulations of the system are presented.

Weistrop, D.↗

An apparent gravitational lens with an image separation of 2.6 arc min

Observations are reported which confirm Paczynski's 1986 speculation that the previously known (Arp and Hazard, 1980) pair of 19th magnitude quasars 1146+111B,C are actually two images of a single object produced by a gravitational lens. The image split is 157 arcsec, more than 20 times greater than any previously reported, thus indicating an exceptionally massive lensing object. The data supporting the lens hypothesis are remarkably similar, high signal-to-noise, moderate resolution spectra of the two components. Both spectra show strong Mg II 2798-angstrom emission at z = 1.012 plus or minus 0.001 with indistinguishable redshifts (delta v = 126 plus or minus 309 km/s), widths (FWHM = 64 plus or minus 4 angstroms) and detailed profile shapes. Both spectra also show broad troughs at 6180 angstroms and several weaker continuum features. Neither object exhibits the O II 3727-A forbidden line which is frequently strong in Mg II emission objects. If the foreground galaxy clustering apparent in a deep R band charge-coupled device image proves insufficient to explain the large image splitting, other possibilities such as massive dark objects (e.g. a black hole of about 10 to the 15th solar masses) or a cosmic string may be indicated.

Turner, E. L.↗

Electron-Focus Adjustment for Photo-Optical Imagers

Internal electron focus made independent of optical focus. Procedure enables fine tuning of internal electron-focusing system of photo-optical imager, without complication by imperfections of associated external optics. Applicable to imager in which electrons emitted from photocathode in optical focal plane, then electrostatically and/or magnetically focused to replica of image in second focal plane containing photodiodes, phototransistorss, charge-coupled devices, multiple-anode outputs, or other detectors.

Fowler, Walter B.↗

Unstable 06.5f?p star HD 148937 and its interstellar environment

The massive, early-type star HD 148937 (spectral type 06.5?p) is surrounded by a unique set of nebulosities. A spherically symmetric Stromgren sphere (Radius approx. - 25 pc), an ellipsoidal filamentary nebulosity (semimajor axis approx. - 5 pc) interpreted as a stellar-wind-blown shell, and a bipolar nebular complex (semimajor axis approx. - 1 pc) with HD 148937 located in the apparent center of symmetry. Observations of these nebulosities are reported (narrow-band charge coupled devices imaging, image dissector scanner (IDS) spectrophotometry, high resolution spectroscopy) in an attempt to establish a consistent model of HD 148937 and its nebulosities.

Leitherer, C.↗

Spectroscopy and CCD-photography of extended red emission in reflection nebulae

Recent spectrographic studies of extended red emission (ERE) seen in the 0.6 to 0.9 micron spectral region in many reflection nebulae have shown fluorescence by amorphous hydrogenated carbon to be the most probable cause of the ERE. Spectrographic observations were performed on the nebulae NGC 2023 and NGC 7023, using the intensified Reticon scanner (IRS) of Kitt Peak National Observatory on the N0-2 0.9 mm telescope. Charge coupled device (CCD) images of NGC2023 and NGC 7023 were obtained with the CfA CCD detector on the 0.6 mm telescope of the Whipple Observatory. Results are discussed.

Witt, A. N.↗

Translucent molecular clouds: Theory and observations

Few suitable stars behind molecular clouds have been identified. A limited survey was performed of interstellar lines toward highly reddened stars in the southern sky, using the ESO 1.4 m CAT telescope with a Reticon detector, and the Cerro Tololo 4 m telescope equipped with a GEC charge coupled device (CCD) detector. Because of the reduced extinction at longer wavelengths, molecules were searched for with transitions in the red part of the spectrum such as C2 and CN. For some lines-of-sight for which C2 was detected, the 4300 A line of CH was also observed. Absorption lines of interstellar C2 around 8750 A were detected in the spectra of about 1/4 of the 36 observed stars. The inferred C2 column densities range between 10 to the 13th power and 10 to the 14th power sq. cm., and are up to an order of magnitude larger than those found for diffuse clouds. The observed column densities of CH correlate very well with those of C2 over this range. In contrast, the measured column densities of CN vary by orders of magnitude between the various regions, and they do not correlate with those of C2 and CH. The observed rotational population distribution of C2 also provides information about the physical conditions in the clouds. Models of translucent molecular clouds have been constructed along the lines described by van Dishoeck and Black (1986) for diffuse clouds. The models compute accurately the fractions of atomic and molecular hydrogen as functions of depth into the clouds, as well as the excitation of H2 by ultraviolet pumping. They also incorporate a detailed treatment of the photodissociation processes of the molecules (cf. van Dishoeck 1986), which play an important role in the chemistry up to depths of about 3 mag.

Vandishoeck, E. F.↗

Integrated infrared array technology

An overview of integrated infrared (IR) array technology is presented. Although the array pixel formats are smaller, and the readout noise of IR arrays is larger, than the corresponding values achieved with optical charge-coupled-device silicon technology, substantial progress is being made in IR technology. Both existing IR arrays and those being developed are described. Examples of astronomical images are given which illustrate the potential of integrated IR arrays for scientific investigations.

Goebel, J. H.↗

Star forming regions in gas-rich SO galaxies

The first results of an H alpha imaging survey of HI rich SO galaxies, which were searched for HII regions and other sources of emission, are presented. The charge coupled device H alpha interference filter images were made of 16 galaxies. Eight of these galaxies show evidence for on-going star formation, one has nuclear emission but no HII regions, and the remaining seven have no emissions detected within well defined upper limits. With the exception of one notably peculiar galaxy in which the emission from HII regions appears pervasive, the HII regions are either organized into inner-disk rings or randomly distributed throughout the disk. A few of these galaxies are found to be clearly not SO's; or peculiar objects atypical of the SO class. Using simple models star formation rates (SFRs) and gas depletion times from the observed H alpha fluxes were estimated. In general, the derived SFRs are much lower than those found in isolated field spiral galaxies and the corresponding gas depletion time scales are also longer.

Pogge, Richard W.↗

The AXAF CCD imaging spectrometer

The AXAF CCD Imaging Spectrometer (ACIS) is currently being defined as a possible focal plane instrument to be flown on the Advanced X-ray Astrophysics Facility (AXAF). The imaging spectrometer consists of an array of charge coupled devices (CCD's) to be placed at the focus of the AXAF mirrors. The array will provide high angular resolution (0.5 arc seconds), moderate spectral resolution (150 eV) over the energy range 0.1 to 10 keV, temporal resolution down to 60 microseconds, and single photon quantum detection efficiencies of up to 90 percent. X-ray sensitivity for a point source exceeds 10 to the -15th ergs/sq cm sec for a 10 to the 5th sec exposure. When used in conjunction with the objective gratings, the array will yield wavelength resolution of up to 200.

Garmire, G. P.↗

Orbit determination accuracy assessment for an asteroid flyby - A Galileo case study

The Galileo spacecraft may be targeted for a close flyby of an asteroid on its way to an encounter with Jupiter. An orbit determination accuracy analysis was carried out for the case of the asteroid 29 Amphitrite based on the use of radio metric and optical data types. Prior to encounter, the uncertainty in the asteroid's position, based on astrometric observations from earth, amounts to several hundred kilometers. This ephemeris uncertainty constitutes the dominant error in the determination of the spacecraft orbit with respect to Amphitrite. It is shown that the spacecraft-asteroid relative position can be improved by imaging asteroid-star pairs with the Galileo charge-coupled device (CCD) camera, enabling an accurate flyby of the asteroid. The main benefit of optical navigation is to enable the instrument pointing updates necessary for closeup viewing of the asteroid. A discussion of the evolution of the target error ellipse parameters as a function of data coverage and various combinations of radiometric and optical data types is also presented.

Kechichian, Jean A.↗

Coronagraph for astronomical imaging and spectrophotometry

A coronagraph designed to minimize scattered light in astronomical observations caused by the structure of the primary mirror, secondary mirror, and secondary support structure of a Cassegrainian telescope is described. Direct (1:1) and reducing (2.7:1) imaging of astronomical fields are possible. High-quality images are produced. The coronagraph can be used with either a two-dimensional charge-coupled device or photographic film camera. The addition of transmission dispersing optics converts the coronagraph into a low-resolution spectrograph. The instrument is modular and portable for transport to different observatories.

Vilas, Faith↗

Qualification of S-glass/epoxy thermal isolator bands

Unidirectional fiberglass reinforced epoxy structures have been evaluated as thermal isolator tension straps for the charge-coupled devices on the Hubble Space Telescope's Wide Field/Planetary Camera. Mechanical and thermal properties are reported for filament-wound S-2 glass in a generic epoxy resin and compared to S-901 glass bands used on a previous camera. Measurements were performed on very small paper clip-shaped bands. Probably the smallest in length and have a load carrying mean cross sectional area of only 0.00024 square inches.

Bauer, Jerry↗

Hybrid X-ray telescope systems

It has been known for some time that glancing incidence X-ray optics have sharply peaked point response functions. The spatial resolution of Wolter X-ray telescope systems is frequently limited by the performance characteristics of the X-ray detector rather than by the optics, even when high resolution detectors such as photographic emulsions are used. This problem becomes even more severe when it is desirable to take advantage of the high sensitivity and broad wavelength response afforded by modern solid state detectors such as charge coupled devices or multi-anode microchannel arrays. Results of theoretical investigations of methods for increasing the telescope plate scale by the use of glancing incidence hyperboloid/ellipsoid X-ray microscope optics and normal incidence contoured layered synthetic microstructure optics for coupling the Wolter mirrors to the detector are reported. The relative merits of the different hybrid X-ray telescope systems which result will be discussed. Considerations will be made concerning applications of these systems to high resolution imagery and spectroscopy of astronomical X-ray/XUV sources.

Shealy, David L.↗

Lightweight Video-Camera Head

Compact, lightweight video camera head constructed by remounting lens and charge-coupled-device image detector from small commercial video camera in separate assembly. Useful in robotics, artificial vision, and vision guidance systems. Designed to be mounted on visor of helmet to monitor motions of eyes in experiments on vestibulo-ocular reflexes.

Proctor, David R.↗

Optical Recognition And Tracking Of Objects

Separate objects moving independently tracked simultaneously. System uses coherent optical techniques to obtain correlation between each object and reference image. Moving objects monitored by charge-coupled-device television camera, output fed to liquid-crystal television (LCTV) display. Acting as spatial light modulator, LCTV impresses images of moving objects on collimated laser beam. Beam spatially low-pass filtered to remove high-spatial-frequency television grid pattern.

Chao, Tien-Hsin↗

A geostationary imaging spectrometer TOMS instrument

One design for a geostationary Total Ozone Mapping Spectrometer (TOMS) with many desirable features is an imaging spectrometer. A preliminary study makes use of a 0.25 m Czerny-Turner spectrometer with which the Earth is imaged on a charge-coupled device (CCD) in dispersed light. The wavelength is determined by a movable grating which can be set arbitrarily by ground control. The signal integration time depends on wavelength but this system allows arbitrary timing by command. Special circumstances such as a requirement to track a low-lying sulfur dioxide cloud or a need to discriminate high level ozone from total ozone at midlatitudes could be obtained by adding a particular wavelength to the normally pre-programmed time sequence. The incident solar irradiance is measured by deploying a diffuser plate in the field of view. Individual detector elements correspond to scene elements in which the several wavelengths are serially sampled and the Earth radiance is compared to the incident sunlight. Thus the problem of uncorrelated drift of multiple detectors is removed.

Krueger, Arlin J.↗

Real time thermal imaging of high temperature semiconductor melts

A real time thermal imaging system with temperature resolution better than + or - 1 C and spatial resolution of better than 0.5 mm was developed and applied to the analysis of melt surface thermal field distributions in both Czochralski and liquid encapsulated Czochralski (LEC) growth configurations. The melt is viewed in near normal incidence by a high resolution charge coupled device camera to which is attached a very narrow bandpass filter. The resulting image is digitized and processed using a pipelined pixel processor operating at an effective 40 million operations per second thus permitting real time high frequency spatial and temporal filtering of the high temperature scene. A multi-pixel averaging algorithm was developed which permits localized, low noise sensing of temperature variations at any location in the hot zone as a function of time. This signial is used to implement initial elements of a feedforward growth control scheme which is aimed at reducing disturbances to the melt caused by the batch nature of the growth process. The effect of magnetic melt stabilization on radial melt temperature distributions was measured using this technique. Problems associated with residual internal reflections and non-optimized path geometry are discussed.

Wargo, Michael J.↗

Integrated infrared array technology

An overview of integrated infrared (IR) array technology is presented. Although the array pixel formats are smaller, and the readout noise of IR arrays is larger than the corresponding values achieved with optical charge-coupled-device silicon technology, substantial progress is being made in IR technology. Both existing IR arrays and those being developed are described. Examples of astronomical images are given which illustrate the potential of integrated IR arrays for scientific investigations.

Goebel, J. H.↗