Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Hanford Double Shell Waste Tank Corrosion Studies (Final Report FY2018)

For FY18, Savannah River National Laboratory (SRNL) focused on four main tasks in its study of corrosion of Hanford Double-Shell Tanks (DSTs). The New Limits task focused on the development of a pitting factor as a localized corrosion predictor. Electrochemical experiments were directed towards pitting factors between 1 and 2 (i.e., borderline conditions) and separating the effects of chloride and fluoride in the pitting factor equation. In addition, long term immersion testing experiments with partial and completely immersed coupons in solutions with a wide range of pitting factors were tested. Secondary liner studies continued this year with a new vapor corrosion inhibition (VCI) strategy in which ground water (GW) simulants at a specified concentration of commercial VCI were mixed. The specific concentrations were recommended by Cortec® and was compared with similar concentration of GW with calcium carbonate. The anodic drift task utilized a simulant corresponding to AN-107 waste tank chemistry. The chemistry was studied with three different surface conditions: mill-scale, partial mill-scale and ground to 600 grit to study the impact of different surfaces on the potential drift. The final task was focused on ammonia concentration determination of a vapor space corrosion (VSC) test vessel using Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) detector. A summary of each task is presented below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Role of pH and Eh in geothermal systems: Thermodynamic examples and impacts on scaling and corrosion

The global demand for sustainable and clean renewable energy sources is rapidly increasing to meet growing energy demands while curtailing the CO2 emissions from fossil fuels. Harnessing the natural heat or geothermal energy of the Earth's interior can simultaneously address both issues by offering a clean and renewable energy source. Enhanced geothermal systems require the movement and cycling of fluid through a porous rock media. Further, this process requires understanding the chemistry occurring at the fluid-rock and fluid-metal interfaces both in the deep subsurface and surface, where fluid is circulated for energy transfer or storage. In this review paper, we evaluate the current state of research on how two key variables, pH and Eh, control the fluid-rock reactions controlling mineral scaling and the steel corrosion reactions associated with geothermal systems. These variables are frequently used in geochemical modeling to predict chemical reactions in geothermal systems. Prediction of the fluid-rock behavior can be utilized to formulate new strategies for extending the lifespan and efficiency of heat extraction and utilization and maximizing the safety of geothermal systems.

15 GEOTHERMAL ENERGY↗

Corrosion Embrittlement of Duralumin III Effect of the Previous Treatment of Sheet Material on the Susceptibility to This Type of Corrosion

As a result of testing, it was determined that control of the rate of quenching and the avoidance of accelerated aging by heating are the only means of modifying duralumin itself so as to minimize the intercrystalline form of corrosive attack. It is so simple a means that it should be adopted even though it may not completely prevent, but only reduce, this form of corrosive attack. By so doing, the need for protection of the surface is less urgent.

Rawdon, Henry S↗

The Development of an INL Capability for High Temperature Flow, Heat Transfer, and Thermal Energy Storage with Applications in Advanced Small Modular Reactors, High Temperature Heat Exchangers, Hybrid Energy Systems, and Dynamic Grid Energy Storage C

The overall goal of this project is to support Idaho National Laboratory in developing a new advanced high temperature multi fluid multi loop test facility that is aimed at investigating fluid flow and heat transfer, material corrosion, heat exchanger characteristics and instrumentation performance, among others, for nuclear applications. Specifically, preliminary research has been performed at The Ohio State University in the following areas: 1. A review of fluoride molten salts’ characteristics in thermal, corrosive, and compatibility performances. A recommendation for a salt selection is provided. Material candidates for both molten salt and helium flow loop have been identified. 2. A conceptual facility design that satisfies the multi loop (two coolant loops [i.e., fluoride molten salts and helium]) multi purpose (two operation modes [i.e., forced and natural circulation]) requirements. Schematic models are presented. The thermal hydraulic performances in a preliminary printed circuit heat exchanger (PCHE) design have been estimated. 3. An introduction of computational methods and models for pipe heat loss analysis and cases studies. Recommendations on insulation material selection have been provided. 4. An analysis of pipe pressure rating and sizing. Preliminary recommendations on pipe size selection have been provided. 5. A review of molten fluoride salt preparation and chemistry control. An introduction to the experience from the Molten Salt Reactor Experiment at Oak Ridge National Laboratory has been provided. 6. A review of some instruments and components to be used in the facility. Flowmeters and Grayloc connectors have been included. This report primarily presents the conclusions drawn from the extensive review of literatures in material selections and the facility design progress at the current stage. It provides some useful guidelines in insulation material and pipe size selection, as well as an introductory review of facility process and components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ion-Exchange Interdiffusion Model with Potential Application to Long-Term Nuclear Waste Glass Performance

Ion exchange is an integral mechanism influencing the corrosion of glasses. Due to the formation of alteration layers in aqueous conditions, it is difficult to conclusively deconvolute the process of ion exchange from other processes, principally dissolution of the glass matrix. Therefore, we have developed a method to isolate alkali diffusion that involves contacting glass coupons with a solution of 6 LiCl dissolved in functionally inert dimethyl sulfoxide. Here, we employ the method at temperatures ranging from 25 to 150 °C with various glass formulations. Glass compositions include simulant nuclear waste glasses, such as SON68 and the international simple glass (ISG), glasses in which the nature of the alkali element was varied, and glasses that contained more than one alkali element. An interdiffusion model based on Fick’s second law was developed and applied to all experiments to extract diffusion coefficients. The model expands established models of interdiffusion to the case where multiple types of alkali sites are present in the glass. Activation energies for alkali ion exchange were calculated and the results are in agreement with those obtained in glass strengthening experiments but are nearly five times higher than values reported for diffusion-controlled processes in nuclear waste glass corrosion experiments. A discussion of the root causes for this apparent discrepancy is provided. The interdiffusion model derived from laboratory experiments is expected to be useful for modeling glass corrosion in a geological repository when the silicon concentration is high.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Corrosion behaviors of friction welded dissimilar aluminum alloys

Highlights: • Corrosion properties of friction welded dissimilar aluminum alloys seem to be governed by the anode part in the weld. • Intense corrosion near the interface has the limited region due to insufficient ionic transport. • Self-formation of a micro-galvanic cell is a main reason for the inferior corrosion performance. - Abstract: Corrosion behaviors of the friction welded dissimilar aluminum alloys were investigated to understand how galvanic effect plays a role in altering corrosion properties of the dissimilar weld. From the fact that the weld had the similar OCP value to that of AA2017, it can be inferred that the corrosion characteristics of the weld is under the control of the AA2017 part in the weld and as a result, only the AA2017 part in the weld had experienced severe corrosion, leaving AA6063 under cathodic protection. Intense corrosion occurring near the interface implies that the area near the interface is placed under the effect of galvanic corrosion and there was the effective distance where the galvanic effect exerts an impact due to the increase in the resistance of the electrolyte with the distance from the interface. The disappearance of Warburg diffusion plot in Nyquist plots for the weld seemed to be the breakdown of the passivation layer related to the formation of the micro-galvanic cell, which in turn presented the shrinkage in the capacitance response, indicating that charge reactions in the form of corrosion occurred.

36 MATERIALS SCIENCE↗

The effect of magnetic field on copper in various corrosive medium

The effect of applied magnetic field on the corrosion behaviour of copper within various corrosive medium is investigated. The copper coupon is immersed in 0.5 M HCl, 0.5 M NaCl and 0.5 M NaOH with or without applying up to 40 mT magnetic fields for 24 hours. The weight loss of copper coupon in HCl increased up to 96.56% with applied magnetic fields. However, in NaOH medium, only 33.33% more weight loss was observed and no difference were observed for coupons in NaCl when magnetic field is applied. This observation indicates that corrosion behaviour in HCl and NaOH is controlled by mass transport that can be influenced by the induced magneto hydrodynamics effect when magnetic field is applied. There was no change in weight loss of copper in NaCl when magnetic field is applied because the corrosion mechanism of copper in NaCl is governed by electron charge transfer.

36 MATERIALS SCIENCE↗

RELATIVE HUMIDITY TESTS IN SUPPORT OF THE 3013 STORAGE AND SURVEILLANCE PROGRAM

Techniques to control the initial relative humidity over oxide/salt mixtures have been developed using cerium oxide as a surrogate for plutonium oxide. Such control is required to validate certain assumptions in the Department of Energy Standard DOE-STD-3013, and to provide essential information to support field surveillance at the storage sites for excess plutonium oxides. Concern over the validity of the assumption that corrosion induced degradation in 3013 containers could be controlled by assuring that the moisture content of any stored oxide/salt mixture was below 0.5 w t% arose when stress corrosion cracks were found in test samples exposed at room temperature to plutonium oxide/salt mixtures having a moisture content only marginally above 0.5 wt %. Additionally, analysis of the stress corrosion cracking observations suggests that the initial relative humidity over the oxide/salt mixture may play a major role in the cracking process. The investigations summarized in this report provide the procedures necessary to control the initial relative humidity to selected values within the range of 16 to 50% by controlling the loading relative humidity (18 to 60%) and the oxide/salt mixture water content (0.05 to 0.45 wt %). The studies also demonstrated that the initial relative humidity may be estimated by calculations using software EQ3/6. Cerium oxide/salt mixtures were used in this study because qualification tests with non-radioactive materials will reduce costs while increasing the breadth of the test programs required to support field surveillances of stored 3013 containers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EXPERT PANEL OVERSIGHT COMMITTEE ASSESSMENT OF FY2008 CORROSION AND STRESS CORROSION CRACKING SIMULANT TESTING PROGRAM

The Expert Panel Oversight Committee (EPOC) has been overseeing the implementation of selected parts of Recommendation III of the final report, Expert Panel workshop for Hanford Site Double-Shell Tank Waste Chemistry Optimization, RPP-RPT-22126. Recommendation III provided four specific requirements necessary for Panel approval of a proposal to revise the chemistry control limits for the Double-Shell Tanks (DSTs). One of the more significant requirements was successful performance of an accelerated stress corrosion cracking (SCC) experimental program. This testing program has evaluated the optimization of the chemistry controls to prevent corrosion in the interstitial liquid and supernatant regions of the DSTs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel use of a hand-held laser induced breakdown spectroscopy instrument to monitor hydride corrosion in uranium

With a compact hand-held laser-induced breakdown spectroscopy (LIBS) instrument, studies were performed on specimens of uranium charged with controlled hydrogen concentrations for a qualitative evaluation of hydride corrosion. Four samples of depleted uranium with two different starting microstructures (cast and rolled) were used for this study. The hydrogen charged samples (rolled 1.8 wppm H and cast 14 wppm H by weight) are representative of the pre-corrosion states with hydrides distributed throughout the bulk. In-depth LIBS measurements were carried out, after the thick surface corrosion layer was removed, by applying 100 laser pulses from sample surface into the bulk on five different sample locations. Three additional areas on each sample were investigated by laser ablation using a 12-point grid approach. The atomic emission signals of elemental uranium, carbon, hydrogen, and oxygen were identified and analyzed. All four samples showed similar uranium and carbon concentrations, as expected. Hydrogen content was consistent with each sample's specification, such that the hydrogen charged samples exhibited higher hydrogen concentration than their references. Both specimens charged with hydrogen showed elevated oxygen content as well, due to rapid oxidation of uranium and uranium hydrides. The oxidation process was facilitated by the laser ablation and plasma plume's high temperature effects on the sample combined with the glovebox environment. The uranium surface damage produced by laser ablation was quantitatively evaluated by optical microscopy.

36 MATERIALS SCIENCE↗

Multifunctional polymer composite coatings and adhesives by incorporating cellulose nanomaterials

Regardless of their applications, polymers are still considered mechanically weak and functionally insufficient for certain demanding coating and adhesive uses. To address those issues, nanomaterials have been extensively studied as reinforcing fillers, which have been proven to effectively promote the performance of polymer coatings/adhesives. However, conventional nanofillers are expensive and non-biodegradable. Meanwhile, cellulose nanomaterials (CNMs), a class of nanomaterials produced from biomass feedstocks, can circumvent the drawbacks of conventional nanofillers. Here, this review paper first focuses on the multi-functionalities CNMs bring to polymer coatings, including mechanical reinforcement (wear resistance and hardness enhancement), gas barrier, flame resistance, corrosion resistance, self-healing (controlled-release), optical regulation, self-cleaning/antifouling, and antimicrobial characteristics. Then we discuss the benefits of CNM addition to polymer adhesives, such as mechanical enhancement, curing promotion, volatile organic compound (VOC) suppression, and electrical conductivity. Finally, we provide insights into future research efforts with CNMs. The goal of this paper is to promote the pilot-scale study and commercial use of CNMs as multifunctional additives in green and sustainable polymer composite coating and adhesive formulations.

36 MATERIALS SCIENCE↗

Cold Spray NDE for Porosity and Other Process Anomalies

This paper describes a technology review of non-destructive examination (NDE) methods that can be applied to cold spray coatings. Cold spray is a process for depositing metal powder at high velocity so that it bonds to the substrate metal without significant heating that would be likely to cause additional residual tensile stresses. Coatings in the range from millimeters to centimeters are possible at relatively high deposition rates. Cold spray coatings that may be used for hydroelectric components that are subject to erosion, corrosion, wear, and cavitation damage are of interest. The topic of cold spray NDE is treated generally however and may be considered applicable to virtually any cold spray application except where there are constraints of the hydroelectric component application that bear special consideration. Hydroelectric turbine components are primarily made from low carbon and austenitic stainless steels. They are typically very large components that are partially assembled on-site. Transport of these components within the hydroelectric facility and away from the hydroelectric facility is challenging due to the component’s size and weight, high cost of disassembly, and the confined space of the dam. One method for prolonging component life is application of cold spray and thermal powder metal coatings to the components most susceptible to erosion, corrosion, cracking, and mechanical wear. Process controls and visual inspections have historically been applied to cold spray application; however, quantitative NDE could detect anomalies not readily apparent from such a visual examination. Optical profilometry, Eddy current, ultrasound, and hardness tests are shown for one set of good, fair, and poor Nickle-Chrome (NiCr) on 304 stainless steel (304SS) cold spray samples to demonstrate inspection possibilities. The primary indicator of cold spray quality is the cold spray porosity that is most directly measured with witness-sample destructive examinations (DE) – mostly photo-micrographs. These DE generated porosity values are correlated with optical profilometry, eddy current, ultrasound, and hardness test NDE methods to infer the porosity and other Information of interest. These parameters of interest primarily include: • Porosity primarily caused by improper process conditions (temperature, gas velocity, spray standoff, spray angle, powder size, condition, surface cleanliness, surface oxide, etc.). • Presence/absence of the cold spray coating including possible over-sprayed voids • Coating thickness Optical profilometry measurements of surface roughness trended with porosity plus if compared with a reference measurement or reference drawing would provide information on the coating thickness. Ultrasound could provide similar surface profile information plus attenuation measurements trended with porosity. The ultrasound measurements however may be limited to geometries where the substrate back-wall is normal to the cold spray surface and not too thick. Eddy current showed a strong correlation with porosity. Eddy currents can also be sensitive to cracks and do not need fluid coupling to make measurements. Eddy currents however are not sensitive to coating thicknesses in most cases. Vickers hardness measurements also tracked well with porosity. These types of hardness measurements however are also not sensitive to coating thickness. An NDE program may include multiple measurements. Acknowledgement: This work is sponsored by Bonneville Power Administration (BPA) under their technology innovation project program. Such support does not constitute BPA endorsement of views expressed in this work.

Glass, Samuel W.↗

Effect of surface segregation on the oxidation resistance of Cu 3 Pt ( 100 )

Alloying element segregation often occurs under a reactive environment but its interplay with the subsequent surface oxidation of the alloy remains unclear. Using synchrotron-based ambient-pressure x-ray photoelectron spectroscopy, we dynamically monitor the surface segregation in Cu 3 Pt(100) in response to temperature and oxygen gas. Vacuum annealing leads to surface segregation of Cu along with the enrichment of Pt in the subsurface region. Upon switching to the O 2 atmosphere, dissociative chemisorption of oxygen does not change the surface segregation profile from that under the vacuum annealing condition. A stepwise increase in the oxygen pressure results in the transformation pathway of Cu → Cu 2 O → CuO, in which the selective oxidation of Cu gives rise to further accumulation of Pt underneath the oxide/alloy interface that hinders the supply of Cu from the bulk to the oxide/alloy interface, thereby leading to the termination of the surface oxidation after the Cu 2 O → CuO conversion is completed. This differs from the transformation pathway of Cu → Cu 2 O → Cu 2 O/CuO for the oxidation of pure Cu and Cu-Au alloys, in which the oxidation of Cu continues and the Cu 2 O/CuO bilayer growth is constantly maintained. Furthermore, these key differences provide useful insight into alloy design for controlling the surface properties such as corrosion resistance and catalytic performance of Cu base alloys.

36 MATERIALS SCIENCE↗

Incorporation of Pertechnetate and Perrhenate into Corroded Steel Surfaces Studied by X-ray Absorption Fine Structure Spectroscopy

Batch reaction experiments and solid-phase characterization analyses were completed to examine the uptake of dissolved perrhenate [Re(VII)] or pertechnetate [Tc(VII)] by A-516 steel coupons that corroded in simulated groundwater solutions or dilute water. The goal was to identify the mechanism(s) that control the uptake of 99Tc by corrosion products on carbon steel in the presence of dilute solutions. X-ray absorption fine structure spectroscopy (XAFS) was used to study the oxidation states of Re and Tc incorporated into the corroded steel coupon surfaces. X-ray fluorescence maps showed that the corroded coupons contain localized regions enriched in Re or Tc. The Re L3 near edge XAS results for the coupons reacted with Re-spiked waters were consistent with all sorbed Re being present as perrhenate and not significantly reduced to Re(IV). Linear combination fits of the EXAFS signals for the perrhenate and ReIVO2 standards indicate that Re sorbed to the steel coupons corroded in simulated J-13 (a relatively dilute Na-HCO3-CO3 groundwater) and even more dilute waters consists of a maximum of 5 and 10% Re(IV), respectively. The fluorescence results also showed that the Re concentrations increased with increasing time of exposure to the x-ray beam time, which suggests that the perrhenate ions are only weakly bonded to the matrix of the corrosion product. In contrast to the Re results, the Tc K edge XAFS results for the coupons reacted in 99Tc-spiked waters indicate that most of the sorbed Tc had been reduced to Tc(IV). The shape of the near edge and extended fine structure is similar to the Tc(IV)-hydrous ferric oxide (HFO) and not the TcO2-nH2O standard. Differences were noted in the XAS results for steel coupons reacted with waters spiked with 0.001 versus 0.1 mmol/L 99Tc in that much more of the sorbed Tc from 0.001 mmol/L 99Tc experiments was in the form of pertechnetate. Comparison of the XAS results for coupons reacted with 0.001 mmol/L 99Tc-spiked dilute simulated Na-HCO3-CO3 groundwater versus 0.001 mmol/L 99Tc-spiked dilute water also suggest that there are likely differences in the sorption mechanism for the pertechnetate fraction in the corrosion product which formed in these two test solutions. The cause for these differences is not known, but is likely due differences in the compositions of the dilute simulated Na-HCO3-CO3 groundwater and more dilute waters, such as the dissolved carbonate concentrations.

36 MATERIALS SCIENCE↗

Corrosion in Supercritical Carbon Dioxide: Materials, Environmental Purity, Surface Treatments, and Flow Issues (Project No. 10-872)

The supercritical CO 2 Brayton cycle is gaining importance for power conversion in the Generation IV fast reactor system because of its high conversion efficiencies. When used in conjunction with a sodium fast reactor, the supercritical CO 2 cycle offers additional safety advantages by eliminating potential sodium-water interactions that may occur in a steam cycle. In power conversion systems for Generation IV fast reactors, supercritical CO 2 temperatures could be in the range of 30°C to 650°C, depending on the specific component in the system. Materials corrosion primarily at high temperatures will be an important issue. Therefore, the corrosion performance limits for materials at various temperatures must be established. The proposed research will have four objectives centered on addressing corrosion issues in a high-temperature supercritical CO 2 environment: Task 1: Evaluation of corrosion performance of candidate alloys in high-purity supercritical CO 2 : The following alloys will be tested: Ferritic-martensitic Steels NF616 and HCM12A, austenitic alloys Incoloy 800H and 347 stainless steel, and two advanced concept alloys, AFA (alumina forming austenitic) steel and MA754. Supercritical CO 2 testing will be performed at 450°C, 550°C, and 650°C at a pressure of 20 MPa, in a test facility that is already in place at the proposing university. High purity CO 2 (99.9998%) will be used for these tests. Task 2: Investigation of the effects of CO, H 2 O, and O 2 impurities in supercritical CO 2 on corrosion: Impurities that will inevitably present in the CO 2 will play a critical role in dictating the extent of corrosion and corrosion mechanisms. These effects must be understood to identify the level of CO 2 chemistry control needed to maintain sufficient levels of purity to manage corrosion. The individual effects of important impurities CO, H 2 O, and O 2 will be investigated by adding them separately to high purity CO 2 . Task 3: Evaluation of surface treatments on the corrosion performance of alloys in supercritical CO 2 : Surface treatments can be very beneficial in improving corrosion resistance. Shot peening and yttrium and aluminum surface treatments will be investigated. Shot peening refines the surface grain sizes and promotes protective Cr-oxide layer formation. Both yttrium and aluminum form highly stable oxide layers (Y 2 O 3 and Al 2 O 3 ), which can get incorporated in the growing Fe-oxide layer to form an impervious complex oxide to enhance corrosion resistance. Task 4: Study of flow-assisted corrosion of select alloys in supercritical CO 2 under a selected set of test conditions: To study the effects of flow-assisted corrosion, tests will be conducted in a supercritical CO 2 flow loop. An existing facility used for supercritical water flow studies at the proposing university will be modified for use in this task. The system is capable of flow velocities up to 10 m/s and can operate at temperatures and pressures of up to 650°C and 20 MPa, respectively. All above tasks will be performed in conjunction with detailed materials characterization and analysis using scanning electron microscopy/energy dispersive spectroscopy (SEM-EDS), x-ray diffraction (XRD), Auger electron spectroscopy (AES) techniques, and weight change measurements. Inlet and outlet gas compositions will be monitored using gas chromatography-mass spectrometry (GCMS).

36 MATERIALS SCIENCE↗

PLUTONIUM-URANIUM EXTRACTION (PUREX) FACILITY ALARACT DEMONSTRATION FOR FILTER HOUSING

This document presents an As Low As Reasonably Achievable Control Technology (ALARACT) demonstration for evaluating corrosion on the I-beam supporting filter housing No.9 for the 291-A-l emission unit of the Plutonium-Uranium Extraction (PUREX) Facility, located in the 200 East Area of the Hanford Site. The PUREX facility is currently in surveillance and maintenance mode. During a State of Washington, Department of Health (WDOH) 291-A-l emission unit inspection, a small amount of corrosion was observed at the base of a high-efficiency particulate air (HEPA) filter housing. A series of internal and external inspections identified the source of the corrosion material as oxidation of a small section of one of the carbon steel I-beams that provides support to the stainless steel filter housing. The inspections confirmed the corrosion is isolated to one I-beam support location and does not represent any compromise of the structural support or filter housing integrity. Further testing and inspections of the support beam corrosion and its cause were conducted but did not determine the cause. No definitive evidence was found to support any degradation of the housing. Although no degradation of the housing was found, a conservative approach will be implemented. The following actions will be taken: (1) The current operating filter housing No.9 will be removed from service. (2) The only remaining available filter housings (No.1, No.2, and No.3) will be placed in service. These filter housings have new HEPA filters fitted with stainless steel frames and faceguards which were installed in the spring of 2007. (3) Filter housings No.5 and No.10 will be put on standby as backups. To document the assessment of the unit, a draft ALARACT filter housing demonstration for the PUREX filter housing was prepared, and informally provided to WDOH on August 7, 2008. A follow up WDOH response to the draft ALARACT filter housing demonstration for the PUREX filter housing questioned whether deteriorated galvanized filter faceguards discovered during an internal filter housing inspection met American Society of Mechanical Engineers (ASME) AG-l or Military Specification (MIL) 51068 standards. The filter system was designed and installed prior to the issuance of AG-l, February 1986; however, MIL 51068 did require galvanized faceguards. The faceguards are not necessary for filtration or structural purposes; it is concluded that the system is in compliance with the intent of the applicable standard. Appendix B provides supporting information to address this issue.

36 MATERIALS SCIENCE↗

Ion and laser microprobes applied to the measurement of corrosion-produced hydrogen on a microscopic scale

An ion microprobe and a laser microprobe were used to measure concentrations of corrosion-produced hydrogen on a microscopic scale. Hydrogen concentrations of several thousand ppm were measured by both analytical techniques below the fracture surfaces of hot-salt stress-corroded titanium alloy specimens. This segregation of hydrogen below fracture surfaces supports a previously proposed theory that corrosion-produced hydrogen is responsible for hot-salt stress-corrosion embrittlement and cracking of titanium alloys. These advanced analytical techniques suggest great potential for many areas of stress-corrosion and hydrogen embrittlement research, quality control, and field inspection applications.

Gray, H. R.↗

Zero-leak valve

Zero-leakage valve has fluid-sealing diaphragm support and flat sievelike sealing surface. Diaphragm-support valve is easy to fabricate and requires minimum maintenance. Potential applications include isolation valve for waste systems and remote air-actuated valve. Device is also useful in controlling flow of liquid fluorine and corrosive fluids at high pressures.

Macglashan, W. F., Jr.↗