Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSED AIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Innovative Open-Source Energy Software to Drive and Enable Energy Savings and Process Optimization

U.S. Department of Energy (DOE) energy system-analysis software tools have been used for years helping to identify over 170 TBTU/year of energy savings through the Save Energy Now “Energy Savings Assessment” and Better Plants “In-Plant Training” Programs. While most of the fundamental energy savings opportunities do not evolve much with time, computer technology never stops, leaving most of these software tools inoperable on modern computers.This has sparked an initiative to revitalize the DOE energy system analysis tools into a new, open-source, integrated software tool suite - MEASUR. Designed for industrial energy coordinators, engineers, utility-program implementers and individuals who are interested in improving system efficiency, MEASUR can aide users in identifying, assessing, and quantifying energy savings opportunities within pump, fan, process heating, steam, motors, and compressed air systems. In addition, the software contains over 40 equipment and property calculators for simple energy-related calculations and analyses.This paper will present a results comparison for each energy-consuming system using data from past DOE-sponsored energy assessments (to establish the accuracy of the savings algorithms) to validate and verify the accuracy of the energy and cost savings calculated by MEASUR. Additionally, an example highlighting 3rd-party development of the tool’s opensource framework into real-time sensor systems and efficiency-optimization will be presented.

Armstrong, Kristina↗

Combustor with axially staged fuel injection

A combustor with axially staged fuel injection includes a plurality of nozzle segments annularly arranged about a center fuel nozzle. Each nozzle segment includes a fuel plenum partially defined between a forward plate and an aft plate and a plurality of tubes that extends through the fuel plenum and the aft plate. A panel fuel injector extends axially downstream from the aft plate and includes an outer wall, an inner wall, a plurality of outlets defined along at least one of the outer wall and the inner wall and a plurality of premix channels defined between the outer wall and the inner wall. Each premix channel is in fluid communication with a fuel supply, a compressed air supply and a respective outlet of the plurality of outlets.

42 ENGINEERING↗

Process Heating Assessments Using DOE’s Manufacturing Energy Assessment Software for Utility Reduction (MEASUR) Tool Suite

Process heating is the most energy-intensive manufacturing process for most sectors of industry. To quantify energy savings from various energy conservation measures, the Department of Energy (DOE) sponsored the development of the Process Heating Assessment and Survey Tool (PHAST) and similar tools for other industrial systems in the early 2000s. It has been used extensively in the Save Energy Now Program’s Energy Savings Assessments and the Better Plants Program’s In-Plant Trainings. Since the initial development of the legacy tools, both computer operating systems and software development have evolved significantly. Thus, DOE has invested in the modernization of PHAST and other legacy software tools to create the Manufacturing Energy Assessment Software for Utility Reduction (MEASUR) tool suite. MEASUR offers a collection of software tools that can aid manufacturing facilities in improving the efficiency of energy systems and equipment (specifically pumps, fans, steam, and process heating) and in conducting “Energy Treasure Hunts”. Eventually, the tool will also add compressed air and process cooling systems. The Process Heating Assessment (PHA) module of MEASUR is an upgrade of the PHAST tool. PHA provides the means to model fuel-fired, steam-based, and electric process heating systems, covering process heating for most industrial plants in manufacturing sector. It also includes several key upgrades, including the ability to consider multi-component charge loads and account for several different areas of energy losses. The new tool includes a comprehensive flue gas calculator to quantify available heat and heat loss for various gaseous, liquid, and solid fuels and new heat loss calculators. It generates a report and a dynamic Sankey diagram to show the energy consumption in various areas of energy use. MEASUR has significantly improved the user experience by adopting a modern software design. This paper details the structure and workflow of PHA and presents a real-world case study to demonstrate energy savings quantification and MEASUR’s outstanding reporting capabilities.

Nimbalkar, Sachin U.↗

Thermal Stability of Silica for Application in Thermal Energy Storage

Free from siting constraints, thermal energy storage (TES) shows promise as an economical alternative to traditional pumped-storage hydropower (PSH) and compressed air energy storage (CAES). As potential thermal energy storage media, many solid particles demonstrate stability over wide temperature ranges which allows for increased sensible energy storage density and is essential in achieving low-cost storage. Silica sand, in the form of a-quartz, is one such candidate. This work presents a brief review of relevant silica thermophysical properties and further investigates the thermal stability of silica particles as a candidate TES media by subjecting them to two different thermal campaigns: (1) a 500-hour thermal treatment at 1200°C under varied atmospheres; and (2) cycling 25, 50, and 100 times between 300°C and 1200°C. For both campaigns, particle stability is examined by means of pre- and post-treatment Mie scattering. An additional XRD analysis is conducted for the 500-hour treatment in air. Results indicate limited changes in both particle distribution and crystallographic structure which is promising for the application as solid particle media for thermal energy storage.

27 ARPA - Advanced Research Projects Agency-Energy↗

Thermal Stability of Silica for Application in Thermal Energy Storage: Preprint

Free from siting constraints, thermal energy storage (TES) shows promise as an economical alternative to traditional pumped-storage hydropower (PSH) and compressed air energy storage (CAES). As potential thermal energy storage media, many solid particles demonstrate stability over wide temperature ranges which allows for increased sensible energy storage density and is essential in achieving low-cost storage. Silica sand, in the form of a-quartz, is one such candidate. This work presents a brief review of relevant silica thermophysical properties and further investigates the thermal stability of silica particles as a candidate TES media by subjecting them to two different thermal campaigns: (1) a 500-hour thermal treatment at 1200°C under varied atmospheres; and (2) cycling 25, 50, and 100 times between 300°C and 1200°C. For both campaigns, particle stability is examined by means of pre- and post-treatment Mie scattering. An additional XRD analysis is conducted for the 500-hour treatment in air. Results indicate limited changes in both particle distribution and crystallographic structure which is promising for the application as solid particle media for thermal energy storage.

27 ARPA - Advanced Research Projects Agency-Energy↗

Open-Loop Control of Adjustable Tuned Mass Dampers for Floating Wind Turbine Platforms

In this study, we demonstrate the ability of adjustable tuned mass dampers (TMDs) to reduce the platform motion of floating offshore wind turbines (FOWTs). The TMDs are located in the hull and provide control authority by varying the amount of water ballast and compressed air in a reservoir over time. The optimal TMD settings depend on the wind and wave conditions of the FOWT. We present an open-loop control scheme that changes the TMD natural frequency based on sea state and a simple method for estimating the peak wave period and significant wave height. The performance of this open-loop control is compared to ideal control of the TMDs (set knowing the exact sea state), a TMD with a constant natural frequency targeting the design load case with the greatest platform motion, and a baseline set of simulations of the platform without TMDs. The constant natural frequency case performs nearly as effectively as the actively controlled case, suggesting that the TMDs can be simply designed for extreme load conditions and provide consistent control over a range of environments; however, the methods used to find the optimal TMD parameters and estimate sea state statistics could be used in other aspects of FOWT control and design.

artificial intelligence↗

Combustor with axially staged fuel injection

A combustor with axially staged fuel injection includes an endcover and a fuel injector that extends axially downstream from the endcover. The fuel injector includes a cylindrical shell formed by an outer wall and an inner wall. A first plurality of outlets is circumferentially spaced across the inner wall. A first plurality of premix channels is defined between the outer wall and the inner wall. Each premix channel of the first plurality of premix channels is in fluid communication with a fuel supply, a compressed air supply and a respective outlet of the first plurality of outlets.

Berry, Jonathan Dwight↗

Review of Wave Energy Converter Power Take-Off Systems, Testing Practices, and Evaluation Metrics: Preprint

While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continuing proving themselves as a promising modern renewable energy field. One of the difficulties that wave energy systems have been struggling to overcome is the design of highly efficient energy conversion systems that can convert the mechanical power, derived from the oscillation of wave activated bodies, into another useful product. Often the power take-off (PTO) is defined as the single unit responsible for converting mechanical power into another usable form such as electricity, pressurized fluid, compressed air, and others. The PTO, and the entire power conversion chain (PCC), is of great importance as it affects not only how efficient wave power is converted into electricity, but also contributes to the mass, size, structural dynamics, and levelized cost of energy (LCOE) of the wave energy converter (WEC). Unlike wind and solar, there is no industrial standard device, or devices, for wave energy conversion and this diversity is transferred to the PTO system. The majority of current WEC PTO systems incorporate a mechanical or hydraulic drive train, power generator, and an electrical control system. The challenge of WEC PTO designs is designing a mechanical-to-electrical component that can efficiently convert irregular, bi-directional, low frequency and low alternating velocity wave motions. While gross average power levels can be predicted in advance, the variable wave elevation input has to be converted into smooth electrical output and hence usually necessitates some type of energy storage system, such as battery storage, accumulator super capacitors, etc., or other means of compensation such as an array of devices. One of the primary challenges for wave energy converter systems is the fluctuating nature of wave resources, which require WEC components to be designed to handle loads (i.e. torques, forces, and powers) that are many times greater than the average load. This approach requires a much greater PTO capacity than the average power output and indicates a higher cost. In addition, supporting mechanical coupling and or gearing can be added to the PCC to help alleviate the difficulties with transmission and control of fluctuating large loads with low frequencies (indicative of wave forcing) into smaller loads at higher frequencies (optimum for conventional electrical machine design) can quickly increase the complexity of the PCC which could result in a greater number of failure modes and increased maintenance costs. All of the previous points demonstrate how the PTO influences WEC dynamics, reliability, performance and cost which are critical design factors. This paper further explores these topics by providing a review of the state-of-the-art PTO systems currently under development, how these novel PTO systems are tested and derisked prior to precommercial deployment, and the evaluation metrics historically used to differentiate between PTO designs and how they can be improved to support control co-design focused development of wave energy systems.

laboratory testing↗

Techno-Economic Analysis of an SOFC Hybrid Carbon Conversion Concept

This is a presentation prepared for the 2023 Hydrogen and Fuel Cell Seminar to take place in Long Beach, CA on February 7-9, 2023. The presentation highlights analysis recently conducted by NETL on the cost and performance associated with operating SOFC systems in a hybridized configuration with compressed air energy storage.

Buchheit, Kyle L.↗

The power of simplification: Operator interface with the AP1000{sup R} during design-basis and beyond design-basis events

The AP1000{sup R} plant is an 1100-MWe pressurized water reactor with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance, safety and cost. The passive safety features are designed to function without safety-grade support systems such as component cooling water, service water, compressed air or HVAC. The AP1000 passive safety features achieve and maintain safe shutdown in case of a design-basis accident for 72 hours without need for operator action, meeting the expectations provided in the European Utility Requirements and the Utility Requirement Document for passive plants. Limited operator actions may be required to maintain safe conditions in the spent fuel pool (SFP) via passive means. This safety approach therefore minimizes the reliance on operator action for accident mitigation, and this paper examines the operator interaction with the Human-System Interface (HSI) as the severity of an accident increases from an anticipated transient to a design basis accident and finally, to a beyond-design-basis event. The AP1000 Control Room design provides an extremely effective environment for addressing the first 72 hours of design-basis events and transients, providing ease of information dissemination and minimal reliance upon operator actions. Symptom-based procedures including Emergency Operating Procedures (EOPs), Abnormal Operating Procedures (AOPs) and Alarm Response Procedures (ARPs) are used to mitigate design basis transients and accidents. Use of the Computerized Procedure System (CPS) aids the operators during mitigation of the event. The CPS provides cues and direction to the operators as the event progresses. If the event becomes progressively worse or lasts longer than 72 hours, and depending upon the nature of failures that may have occurred, minimal operator actions may be required outside of the control room in areas that have been designed to be accessible using components that have been designed to be reliable in these conditions. The primary goal of any such actions is to maintain or refill the passive inventory available to cool the core, containment and spent fuel pool in the safety-related and seismically qualified Passive Containment Cooling Water Storage Tank (PCCWST). The seismically-qualified, ground-mounted Passive Containment Cooling Ancillary Water Storage Tank (PCCAWST) is also available for this function as appropriate. The primary effect of these actions would be to increase the coping time for the AP1000 during design basis events, as well as events such as those described above, from 72 hours without operator intervention to 7 days with minimal operator actions. These Operator actions necessary to protect the health and safety of the public are addressed in the Post-72 Hour procedures, as well as some EOPs, AOPs, ARPs and the Severe Accident Management Guidelines (SAMGs). Should the event continue to become more severe and plant conditions degrade further with indications of inadequate core cooling, the SAMGs provide guidance for strategies to address these hypothetical severe accident conditions. The AP1000 SAMG diagnoses and actions are prioritized to first utilize the AP1000 features that are expected to retain a damaged core inside the reactor vessel. Only one strategy is undertaken at any time. This strategy will be followed and its effectiveness evaluated before other strategies are undertaken. This is a key feature of both the symptom-oriented AP1000 EOPs and the AP1000 SAMGs which maximizes the probability of retaining a damaged core inside the reactor vessel and containment while minimizing the chances for confusion and human errors during implementation. The AP1000 SAMGs are simple and straight-forward and have been developed with considerable input from human factors and plant operations experts. Most importantly, and different from severe accident management strategies for other plants, the AP1000 SAMGs do not require diagnosis of the location of the core (i.e., whether reactor vessel failure has occurred). This is a fundamental consequence of the AP1000 In-Vessel Retention approach, which allows severe accident management to be based on fundamental principles (e.g. provide coolant as close as possible to the core) that do not change during a specific event. This eliminates the need for one of the more difficult diagnostic requirements, since reactor vessel failure does not directly relate to any measurable plant parameter, and differs from other designs in that an engineered failure of the pressure vessel' (e.g. core catcher) is never required. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pneumatic System for the Neutron Generator Facility at SRNL

A neutron generator system equipped with a pneumatic sample transfer system, enables scientists to perform neutron activation analysis with increased efficiency and accuracy. The samples are placed in sealed containers called 'rabbits' and are passed through the system. Once sealed in the rabbit, the samples are loaded into the tubes via a hopper mechanism. The sample is launched into the generator with compressed air and captures neutrons, causing the sample to become radioactive. Next, the sample is sent to a detector, where the samples are counted for a set length of time on a Ge detector. Once the detection is completed, the sample is then sent to the trash. The system utilizes an interface to select which generator valve and detector location to send the sample too. This project is supports the future development of the neutron generator in the F wing of 773-A. A program is used to automate the passing of the rabbit through the system. The user is able to select the generator valve and detector to be utilized in the testing of the sample. Using the 'Add Rabbit' button the user can add as many sample rabbits to rabbit editor tab. Characteristics are then entered into the fields for each rabbit. The Pre-Det Cooldown and Post-Det Cooldown are intervals used to space out the time before the rabbit is sent into and out of the detector. After all characteristics are entered, the 'Submit to Hopper' button is selected thus preparing the program to run the rabbits in the inserted order. Small setup of the system using the available parts. Simulates the movement of the rabbit from the generator to the detector. Small valves are located before each manifold. To transport the rabbit from one side to the other, the valve of the sending side must be open and the receiving side must be closed. The manifold and valve in direct line with the compressor would extend to the hopper. Once the hopper is loaded, the valve would be open to send the rabbit to generator. Additional manifolds and other mechanical parts are necessary to complete the system design. To complete the construction of the system additional parts, such as the mechanical parts for the switching mechanism and the solenoid valves, are necessary. Further, to complete the automatization of the system, an Arduino is required to communicate with the valves and adjust the linear servos appropriately so that the rabbits are sent to the selected generator location and detector. This work is aimed to be completed in the next fiscal year.

42 ENGINEERING↗

On a new type of wind tunnel

Discussed here is a new type of wind tunnel, its advantages, the difficulties attendant upon its use, and the special methods required for its operation. The main difference between the new type of wind tunnel and the ones now in operation is the use of a different fluid. The idea is to diminish the effect of viscosity If air is compressed, it becomes a fluid with new properties - a fluid that is best suited for reliable and exact tests on models. When air is compressed, its density increases, but its viscosity does not. It is argued that the increase of pressure greatly increases the range and value of wind tunnel tests. Reynolds number, deductions from the Reynolds law, the causes of errors that result in differences between tests on models and actual flights, and the dimensions of a compressed air wind tunnel are covered.

Munk, Max↗

Compressibility and Heating Effects on Pressure Loss and Cooling of a Baffled Cylinder Barrel

Theoretical investigations have shown that, because air is compressible, the pressure-drop requirements for cooling an air-cooled engine will be much greater at high altitudes and high speeds than at sea level and low speeds. Tests were conducted by the NACA to obtain some experimental confirmation of the effect of air compressibility on cooling and pressure loss of a baffled cylinder barrel and to evaluate various methods of analysis. The results reported in the present paper are regarded as preliminary to tests on single-cylinder and multicylinder engines. Tests were conducted over a wide range of air flows and density altitudes.

Goldstein, Arthur W↗

Compressibility and Heating Effects on Pressure Loss and Cooling of a Baffled Cylinder Barrel

Theoretical investigations have shown that, because air is compressible, the pressure-drop requirements for cooling an air-cooled engine will be much greater at high altitudes and high speeds than at sea level and low speeds. Tests were conducted by the NACA to obtain some experimental confirmation of the effect of air compressibility on cooling and pressure loss of a baffled cylinder barrel and to evaluate various methods of analysis. The results reported in the present paper are regarded as preliminary to tests on single-cylinder and multi-cylinder engines. Tests were conducted over a wide range of air flows and density altitudes.

Goldstein, Arthur W.↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗