Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CO2 absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Infrared Signature Masking by Air Plasma Radiation

Detailed measurements and modeling of the spectral emission of an atmospheric pressure air plasma at temperatures up to -3400 K have been made. The cold gas injected in the plasma torch contained an estimated mole fraction of water vapor of approximately 4.5 x 10(exp -3) and an estimated carbon dioxide mole fraction of approximately 3.3 x 10(exp -4). Under these conditions, the minimum level of air plasma emission is found to be between 3.9 and 4.15 microns. Outside this narrow region, significant spectral emission is detected that can be attributed to the fundamental and overtone bands of NO and OH, and to the v(sub 3) and the (v(sub 1)+v(sub 3)) bands Of CO2. Special attention was paid to the effects of ambient air absorption in the optical path between the plasma and the detector. Excellent quantitative agreement is obtained between the measured and simulated spectra, which are both on absolute intensity scales, thus lending confidence in the radiation models incorporated into NEQAIR2-IR over the course of this research program.

Kruger, C. H.↗

Miniaturized Laser Absorption Spectrometer for Combustion Calorimetry and Process Monitoring

A miniaturized tunable laser absorption spectrometer capable of measuring gas-phase concentrations of CO, CO2, and O2 has been developed for operation in spacecraft environments. As part of the Spacecraft Fire Safety Demonstration (Saffire) project, we previously demonstrated the Combustion Product Monitor (CPM) instrument to characterize pyrolysis of relevant test materials in low gravity aboard a transfer vehicle returning from low Earth orbit. Here, we adapted the CPM instrument design to achieve detection of CO, CO2, and O2 with improved minimum detection limits and dynamic range as well as reduced instrument size and power. The instrument can be operated in either an open or sealed configureation, allowing for ambient gas composition measuremnts or in-line monitoring of gas streams. By accurately monitoring CO, CO2, and O2 with broad pressure/temperature calibration and response time on the order of 1 s, the instrument can be used to characterize the dynamics of combustion reactions in a variety of environments.

Briggs, Ryan M.↗

A Two Micron Coherent Differential Absorption Lidar Development

A pulsed, 2-micron coherent Differential Absorption Lidar (DIAL)/Integrated Path Differential Absorption (IPDA) transceiver, developed under the Laser Risk Reduction Program (LRRP) at NASA, is integrated into a fully functional lidar instrument. This instrument measures atmospheric CO2 profiles (by DIAL) from a ground platform. It allows the investigators to pursue subsequent in science-driven deployments, and provides a unique tool for Active Sensing of CO2 Emissions over Night, Days, and Seasons (ASCENDS) validation that was strongly advocated in the recent ASCENDS Workshop. Keywords: Differential Absorption Lidar, Near Infrared Laser,

Yu, Jirong↗

A Preliminary Study of CO2 Flux Measurements by Lidar

A mechanistic understanding of the global carbon cycle requires quantification of terrestrial ecosystem CO2 fluxes at regional scales. In this paper, we analyze the potential of a Doppler DIAL system to make flux measurements of atmospheric CO2 using the eddy-covariance and boundary layer budget methods and present results from a ground based experiment. The goal of this study is to put CO2 flux point measurements in a mesoscale context. In June 2007, a field experiment combining a 2-m Doppler Heterodyne Differential Absorption Lidar (HDIAL) and in-situ sensors of a 447-m tall tower (WLEF) took place in Wisconsin. The HDIAL measures simultaneously: 1) CO2 mixing ratio, 2) atmosphere structure via aerosol backscatter and 3) radial velocity. We demonstrate how to synthesize these data into regional flux estimates. Lidar-inferred fluxes are compared with eddy-covariance fluxes obtained in-situ at 396m AGL from the tower. In cases where the lidar was not yet able to measure the fluxes with acceptable precision, we discuss possible modifications to improve system performance.

Gibert, Fabien↗

Optical properties of CO2 ice and CO2 snow from ultraviolet to infrared: Application to frost deposits and clouds on Mars

Researchers found that it is possible to grow large clear samples of CO2 ice at Mars-like temperatures of 150-170K if a temperature controlled refrigerator is connected to an isolated two-phase pure CO2 system. They designed a chamber for transmission measurements whose optical path between the 13mm diameter window is adjustable from 1.6mm to 107mm. This will allow measurements of linear absorption down to less than 0.01 cm (exp -1). A preliminary transmission spectrum of a thick sample of CO2 ice in the near infrared was obtained. Once revised optical constants have been determined as a function of wavelength and temperature, they can be applied to spectral reflectance/emissivity models for CO2 snow surfaces, both pure and contaminated with dust and water ice, using previously established approaches. It will be useful, also, to develop an infrared scattering-emission cloud radiance model (especially as viewed from near the limb) in order to develop a strategy for the identification of CO2 cloud layers by the atmospheric infrared radiometer instrument on the Mars Observer.

Hansen, Gary B.↗

Precision measurements of photoabsorption cross sections of Ar, Kr, Xe, and selected molecules at 58.4, 73.6, and 74.4 nm

Absolute absorption cross sections have been measured for the rare gases at 58.43, 73.59, and 74.37 nm with an accuracy of + or - 0.8 percent. For the molecules H2, N2, O2, CO, N2O, CO2, and CH4, precision measurements were made at 58.43 nm with an accuracy of + or - 0.8 percent. Molecular absorption cross sections are also reported at 73.59 and 74.37 nm. However, in the vicinity of these wavelengths most molecules exhibit considerable structure, and cross sections measured at these wavelengths may depend on the widths and the amounts of self-reversal of these resonance lines. A detailed discussion is given of the systematic errors encountered with the double-ion chamber used in the cross-sectional measurements. Details are also given of precision pressure measurements.

Samson, James A. R.↗

Total absorption cross sections of several gases of aeronomic interest at 584 A.

Total photoabsorption cross sections have been measured at 584.3 A for N2, O2, Ar, CO2, CO, NO, N2O, NH3, CH4, H2, and H2S. A monochromator was used to isolate the He I 584 line produced in a helium resonance lamp, and thin aluminum filters were used as absorption cell windows, thereby eliminating possible errors associated with the use of undispersed radiation or windowless cells. Sources of error are examined, and limits of uncertainty are given. Previous relevant cross-sectional measurements and possible error sources are reviewed. Wall adsorption as a source of error in cross-sectional measurements has not previously been considered and is discussed briefly.

Starr, W. L.↗

Coherent CO2 lidar: A superior system for observing clouds?

Lidars have long been used to study various parameters of clouds. NOAA's Wave Propagation Laboratory has operated a coherent CO2 lidar for over a decade, using Doppler to study wind fields and turbulence, atmospheric absorption for Differential Absorption Lidar (DIAL) applications, backscatter to investigate aerosol distributions, and backscatter and extinction measurements on clouds. A system under development for our laboratory promises to overcome the older system's problems of large size, frequency instability, and need for continual operator attention. We are also thoroughly evaluating the capabilities of CO2 lidar for observing clouds, including development of some new techniques. CO2 lidar provides a view of clouds different in many ways from that of lidars at other extinction measurements from clouds. This discussion argues in support of the proposition: coherent CO2 lidar can be a superior lidar system for measuring most cloud properties.

Eberhard, Wynn L.↗

Collision-induced Absorption in the Infrared: A Data Base for Modelling Planetary and Stellar Atmospheres

Accurate knowledge of certain collision-induced absorption continua of molecular pairs such as H2-H2, H2-He, H2-CH4, CO2-CO2, etc., is a prerequisite for most spectral analyses and modelling attempts of atmospheres of planets and cold stars. We collect and regularly update simple, state of the art computer programs for the calculation of the absorption coefficient of such molecular pairs over a broad range of temperatures and frequencies, for the various rotovibrational bands. The computational results are in agreement with the existing laboratory measurements of such absorption continua, recorded with a spectral resolution of a few wavenumbers, but reliable computational results may be expected even in the far wings, and at temperatures for which laboratory measurements do not exist. Detailed information is given concerning the systems thus studied, the temperature and frequency ranges considered, the rotovibrational bands thus modelled, and how one may obtain copies of the FORTRAN77 computer programs by e-mail.

Borysow, Aleksandra↗

Atmospheric Airborne Pressure Measurements Using the Oxygen A Band for the ASCENDS Mission

We report on airborne atmospheric pressure measurements using new fiber-based laser technology and the oxygen A-band at 765 nm. Remote measurements of atmospheric temperature and pressure are required for a number of NASA Earth science missions and specifically for the Active Sensing of CO2 Emissions Over Nights, Days, and Seasons (ASCENDS) mission. Accurate measurements of tropospheric CO2 on a global scale are very important in order to better understand its sources and sinks and to improve predictions on any future climate change. The ultimate goal of a CO2 remote sensing mission, such as ASCENDS, is to derive the CO2 concentration in the atmosphere in terms of mole fraction in unit of parts-per-million (ppmv) with regard to dry air. Therefore, both CO2 and the dry air number of molecules in the atmosphere are needed in deriving this quantity. O2 is a stable molecule and uniformly mixed in the atmosphere. Measuring the O2 absorption in the atmosphere can thus be used to infer the dry air number of molecules and then used to calculate CO2 concentration. With the knowledge of atmospheric water vapor, we can then estimate the total surface pressure needed for CO2 retrievals. Our work, funded by the ESTO IIP program, uses fiber optic technology and non-linear optics to generate 765 nm laser radiation coincident with the Oxygen A-band. Our pulsed, time gated technique uses several on- and off-line wavelengths tuned to the O2 absorption line. The choice of wavelengths allows us to measure the pressure by using two adjacent O2 absorptions in the Oxygen A-band. Our retrieval algorithm fits the O2 lineshapes and derives the pressure. Our measurements compare favorably with a local weather monitor mounted outside our laboratory and a local weather station.

Riris, Haris↗

Atmospheric Airborne Pressure Measurements Using the Oxygen A Band for the ASCENDS Mission

We report on airborne atmospheric pressure measurements using new fiber-based laser technology and the oxygen A-band at 765 nm. Remote measurements of atmospheric temperature and pressure are required for a number of NASA Earth science missions and specifically for the Active Sensing of CO2 Emissions Over Nights, Days, and Seasons (ASCENDS) mission. Accurate measurements of tropospheric CO2 on a global scale are very important in order to better understand its sources and sinks and to improve predictions on any future climate change. The ultimate goal of a CO2 remote sensing mission, such as ASCENDS, is to derive the CO2 concentration in the atmosphere in terms of mole fraction in unit of parts-per-million (ppmv) with regard to dry air. Therefore, both CO2 and the dry air number of molecules in the atmosphere are needed in deriving this quantity. O2 is a stable molecule and uniformly mixed in the atmosphere. Measuring the O2 absorption in the atmosphere can thus be used to infer the dry air number of molecules and then used to calculate CO2 concentration. With the knowledge of atmospheric water vapor, we can then estimate the total surface pressure needed for CO2 retrievals. Our work, funded by the ESTO IIP program, uses fiber optic technology and non-linear optics to generate 765 nm laser radiation coincident with the Oxygen A-band. Our pulsed, time gated technique uses several on- and off-line wavelengths tuned to the O2 absorption line. The choice of wavelengths allows us to measure the pressure by using two adjacent O2 absorptions in the Oxygen A-band. Our retrieval algorithm fits the O2 lineshapes and derives the pressure. Our measurements compare favorably with a local weather monitor mounted outside our laboratory and a local weather station.

Riris, Haris↗

Tunable high pressure lasers

Atmospheric transmission of high energy CO2 lasers is considerably improved by high pressure operation which, due to pressure broadening, permits tuning the laser lines off atmospheric absorption lines. Pronounced improvement is shown for horizontal transmission at altitudes above several kilometers and for vertical transmission through the entire atmosphere. Applications of tunable high pressure CO2 lasers to energy transmission and to remote sensing are discussed along with initial efforts in tuning high pressure CO2 lasers.

Hess, R. V.↗

Quantification of UV stimulated ice chemistry: CO and CO2

Recent laboratory experiments are presented that show that during photolysis of the pure ices there is evidence of the interconversion of CO to CO2 and CO2 to CO using Lyman alpha (1216A) radiation. In addition, there is a substantial amount of another substance being produced. This substance is evident by its infrared absorption peak at 2235 cm(-1). It is believed that this new peak is due to carbon suboxide, C3O2. CO and CO2 have already been detected in comets, and C3O2 has been suggested as a cometary from radiation of CO. Comparisons are made between our results at 1215A and proton radiation experiments and radiation at other wavelengths. The suggestion is that the processing of ices is energy dependent, i.e., dependent on the type of radiation. Several difficult problems have to be solved before these radiation conversions can be quantified. The steps that we are taking to quantify the kinetics are discussed.

Anicich, V. G.↗

Airborne Demonstration of Atmospheric Oxygen Optical Depth Measurements with an Integrated Path Differential Absorption Lidar

We report on an airborne demonstration of atmospheric oxygen (O2) optical depth measurements with an Integrated Path Differential Absorption (IPDA) lidar using a fiber-based laser transmitter and photon counting detectors. Accurate atmospheric temperature and pressure measurements are needed for NASA's Active Sensing of CO2 Emissions over Nights, Days and Seasons (ASCENDS) mission. Since O2 is uniformly mixed in the atmosphere, its spectrum can be used to estimate the dry mixing ratio of CO2. In its airborne configuration, the IPDA lidar uses an Erbium Doped Fiber amplifier, a frequency doubler and single photon counting detectors to measure O2 absorption at multiple wavelengths near 765 nm. This instrument was deployed in 2013 and 2014 aboard NASA's DC-8 airborne laboratory as part of two campaigns to measure CO2 mixing ratios over a wide range of topography and weather conditions from altitudes ranging between 3 km and 13 km. In this paper we will review a summary of the results from our flights, discuss the errors that limit the precision and accuracy of the measurement and identify possible areas of improvement.

Methane↗

DIAL with heterodyne detection including speckle noise: Aircraft/shuttle measurements of O3, H2O, and NH3 with pulsed tunable CO2 lasers

Atmospheric trace constituent measurements with higher vertical resolution than attainable with passive radiometers are discussed. Infrared differential absorption lidar (DIAL), which depends on Mie scattering from aerosols, has special advantages for tropospheric and lower stratospheric applications and has great potential importance for measurements from shuttle and aircraft. Differential absorption lidar data reduction involves comparing large amplitude signals which have small differences. The accuracy of the trace constituent concentration inferred from DIAL measurements depends strongly on the errors in determining the amplitude of the signals. Thus, the commonly used SNR expression (signal divided by noise in the absence of signal) is not adequate to describe DIAL measurement accuracy and must be replaced by an expression which includes the random coherent (speckle) noise within the signal. A comprehensive DIAL computer algorithm is modified to include heterodyne detection and speckle noise. Examples for monitoring vertical distributions of O3, H2O, and NH3 using a ground-, aircraft-, or shuttle-based pulsed tunable CO2 laser DIAL system are given.

Brockman, P.↗

Development of an infrared absorption transducer to monitor partial pressure of carbon dioxide for space applications

An infrared (IR) carbon dioxide (CO2) transducers has been designed, developed, and produced for space applications. The transducer provides measurement of partial pressure of CO2 in life support applications, including the Extravehicular Mobility Unit (EMU), Space Shuttle Orbiter and Spacehab. The electrochemical sensor presently used for these applications has a slow reponse time and has reliability concerns due to the electrolyte. The new microprocessor based unit has a fast response time and can be tailored to other space applications.

Lutz, Glenn↗

Heterodyne frequency measurements on N2O at 5.3 and 9.0 microns

Heterodyne frequency measurements on the 01(1)1-00(0)0 band of N2O have been made with the use of a tunable-diode laser, CO laser transfer oscillator, and a CO2 laser frequency synthesizer. A beat frequency was measured between a CO laser and tunable-diode laser whose frequency was locked to the peak of N2O absorption features. The frequency of the CO laser was simultaneously determined by neasuring the beat frequency with respect to a reference synthesized from two CO2 lasers. New rovibrational constants are given for the 01(1)1 state of N2O, which are in excellent agreement with previous results, although the band center is 4 MHz higher than in the previous measurements. A table for the line frequencies and their absolute uncertainties is given for the N2O absorption lines in the wave-number region from 1830 to 1920 kaysers. Some additional frequency measurements near the lower-frequency end of the 02(0)0-00(0)0 band have also been made with respect to a C-12)(0-18)2 laser.

Wells, J. S.↗

A far wing line shape theory and its application to the foreign-broadened water continuum absorption. III

The far wing line shape theory developed previously and applied to the calculation of the continuum absorption of pure water vapor is extended to foreign-broadened continua. Explicit results are presented for H2O-N2 and H2O-CO2 in the frequency range from 0 to 10,000/cm. For H2O-N2 the positive and negative resonant frequency average line shape functions and absorption coefficients are computed for a number of temperatures between 296 and 430 K for comparison with available laboratory data. In general the agreement is very good.

Ma, Q.↗