Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHROMIUM ALLOY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

PdCr based high temperature static strain gage

The program at NASA Lewis Research Center to develop a high temperature static strain gage system for the hypersonic vehicle and turbine engine research has emphasized a palladium-13 wt pct chromium (PdCr) alloy. Gages made from this alloy are being developed in both fine wire and thin film form. The wire gage system had platinum wire as a temperature compensator and was coated with a special alumina and zirconia mixture overcoat. This PdCr compensated wire gage responded linearly to the imposed strain to at least 1000 microstrain. The apparent strain varied within 300 microstrain from room temperature to 800 C with a reproducibility within 50 microstrain between thermal cycles to 800 C. The sputtered thin film PdCr strain gage, whose size was 8 x 8 mm and 10 microns thick, has demonstrated the possibility of extending the use of the PdCr strain gage to a temperature of approximately 1000 C.

Lei, Jih-Fen↗

Friction Stir Welding of GR-Cop 84 for Combustion Chamber Liners

GRCop-84 is a copper-chromium-niobium alloy developed by the Glenn Research Center for liquid rocket engine combustion chamber liners. GRCop-84 exhibits superior properties over conventional copper-base alloys in a liquid hydrogen-oxygen operating environment. The Next Generation Launch Technology program has funded a program to demonstrate scale-up production capabilities of GR-Cop 84 to levels suitable for main combustion chamber production for the prototype rocket engine. This paper describes a novel method of manufacturing the main combustion chamber liner. The process consists of several steps: extrude the GR-Cop 84 powder into billets, roll the billets into plates, bump form the plates into cylinder halves and friction stir weld the halves into a cylinder. The cylinder is then metal spun formed to near net liner dimensions followed by finish machining to the final configuration. This paper describes the friction stir weld process development including tooling and non-destructive inspection techniques, culminating in the successful production of a liner preform completed through spin forming.

Russell, Carolyn K.↗

VPS GRCop-84 Liner Development Efforts

For the past several years, NASA's Marshall Space Flight Center (MSFC) has been working with Plasma Processes, Inc. (PPI) to fabricate combustion chamber liners using the Vacuum Plasma Spray (VPS) process. Multiple liners of a variety of shapes and sizes have been created. Each liner has been fabricated with GRCop-84 (a copper alloy with chromium and niobium) and a functional gradient coating (FGC) on the hot wall. While the VPS process offers versatility and a reduced fabrication schedule, the material system created with VPS allows the liners to operate at higher temperatures, with maximum blanch resistance and improved cycle life. A subscal unit (5K lbf thrust class) is being cycle tested in a LOX/Hydrogen thrust chamber assembly at MSFC. To date, over 75 hot-fire tests have been accumulated on this article. Tests include conditions normally detrimental to conventional materials, yet the VPS GRCop-84 liner has yet to show any signs of degradation. A larger chamber (15K lbf thrust class) has also been fabricated and is being prepared for hot-fire testing at MSFC near the end of 2003. Linear liners have been successfully created to further demonstrate the versatility of the process. Finally, scale up issues for the VPS process are being tackled with efforts to fabricate a full size, engine class liner. Specifically, a liner for the SSME's Main Combustion Chamber (MCC) has recently been attempted. The SSME size was chosen for convenience, since its design was readily available and its size was sufficient to tackle specific issues. Efforts to fabricate these large liners have already provided valuable lessons for using this process for engine programs. The material quality for these large units is being evaluated with destructive analysis and these results will be available by the end of 2003.

Elam, Sandra K.↗

An Examination of Materials in Launch Vehicle Propulsion

The primary activities carried out for this effort used Mr. Glasgow's communication skills and materials expertise. He worked closely with both the Space Transportation Project Office and the Materials Division, preparing summaries of the weekly Space Transportation Project Office activities for use by the Materials and the Structures Divisions and for distribution to other portions of the GRC. Mr. Glasgow participated in systems analysis and planning sessions of the Program Office, serving as both a representative of the microtechnologists and as a reviewer of the macrotechnologies involved in proposed new launch vehicles. He helped define the technology readiness level of those new vehicle concepts and provided especially critical expertise to provide realistic technical assessments to various vehicle proponents. While a major portion of his work was performed at the GRC site, travel was required to Langley and to Nashville. In addition to the written contributions mentioned above, he presented summaries of Materials Division activities and interests in industry briefings. Mr. Glasgow continued his interest in the copper-chromium-niobium alloy system, a system originally identified by him as a potential rocket engine material and now chosen as baseline for two new rocket engine designs by the leading US builder of rocket engines.

Source record↗

PdCr Based High Temperature Static Strain Gage

The program at NASA Lewis Research Center to develop a high temperature static strain gage system for the hypersonic vehicle and turbine engine research has emphasized a palladium- 13wt%chromium (PdCr) alloy. Gages made from this alloy are being developed in both fine wire and thin film form. The wire gage system had platinum wire as a temperature compensator and was coated with a special alumina and zirconia mixture overcoat. This PdCr compensated wire gage responded linearly to the imposed strain to at least i000 microstrain. The strain sensitivity of the gage did not vary much with temperature. The apparent strain of this compensated gage was significantly lower than that of the other gages. It varied within 300 microstrain from room temperature to 800 deg. C with a reproducibility within 50 microstrain between thermal cycles to 800 deg. C. This is a significant advance over the 400 deg. C barrier of previous techniques for resistance static strain gages. The sputtered thin film PdCr strain gage, whose size was 8x8 mm and 10 micron thick, has demonstrated the possibility of extending the use of the PdCr strain gage to a temperature of approximately 1000 deg. C.

Lei, Jih-Fen↗

An Intelligent Strain Gauge with Debond Detection and Temperature Compensation

The harsh rocket propulsion test environment will expose any inadequacies associated with preexisting instrumentation technologies, and the criticality for collecting reliable test data justifies investigating any encountered data anomalies. Novel concepts for improved systems are often conceived during the high scrutiny investigations by individuals with an in-depth knowledge from maintaining critical test operations. The Intelligent Strain Gauge concept was conceived while performing these kinds of activities. However, the novel concepts are often unexplored even if it has the potential for advancing the current state of the art. Maturing these kinds of concepts is often considered to be a tangential development or a research project which are both normally abandoned within the propulsion-oriented environment. It is also difficult to justify these kinds of projects as a facility enhancement because facility developments are only accepted for mature and proven technologies. Fortunately, the CIF program has provided an avenue for bringing the Intelligent Strain Gauge to fruition. Two types of fully functional smart strain gauges capable of performing reliable and sensitive debond detection have been successfully produced. Ordinary gauges are designed to provide test article data and they lack the ability to supply information concerning the gauge itself. A gauge is considered to be a smart gauge when it provides supplementary data relating other relevant attributes for performing diagnostic function or producing enhanced data. The developed strain gauges provide supplementary signals by measuring strain and temperature through embedded Karma and nickel chromium (NiCr) alloy elements. Intelligently interpreting the supplementary data into valuable information can be performed manually, however, integrating this functionality into an automatic system is considered to be an intelligent gauge. This was achieved while maintaining a very low mass. The low mass enables debond detection and temperature compensation to be performed when the gauge is utilized on small test articles. It was also found that the element's mass must be relatively small to avoid overbearing the desired thermal dissipation characteristics. Detecting the degradation of a gauge s bond was reliably achieved by correlating thermal dissipation with the bond s integrity. This was accomplished by precisely coupling a NiCr element with a Karma element for accurately interjecting and quantifying thermal energy. A finite amount of thermal energy is consistently placed in the gauge by electrically powering the NiCr element. The energy will only be temporarily stored before it begins to dissipate into the surrounding structure through the gauge bond. The ability to transmit the energy into the structure becomes greatly inhibited by any discontinuity in the bond s substrate. Therefore, the way the thermal dissipation occurs will reveal even the slightest change in the integrity of the bond.

Jensen, Scott L.↗

Rapid Quench in an Electrostatic Levitator

The Electrostatic Levitation (ESL) Laboratory at the NASA Marshall Space Flight Center (MSFC) is a unique facility for investigators studying high-temperature materials. The ESL laboratory’s main chamber has been upgraded with the addition of a rapid quench system. This system allows samples to be dropped into a quench vessel that can be filled with a low melting point material, such as a gallium or indium alloy, as a quench medium. Thereby allowing rapid quenching of undercooled liquid metals. Up to eight quench vessels can be loaded into a wheel inside the chamber that is indexed with control software. The system has been tested successfully with samples of zirconium, iron-cobalt alloys, iron-chromium-nickel, titanium-zirconium-nickel alloys, and a silicon-cobalt alloy. This new rapid quench system will allow materials science studies of undercooled materials and new materials development. The system is described and some initial results are presented.

SanSoucie, Michael P.↗

Neutron Absorber Considerations for the DOE Standardized Canister

The Department of Energy (DOE) standardized canister is being re-evaluated to support the management of non-commercial spent nuclear fuel. The standardized canister would allow a broad range of DOE-managed fuels to be loaded, stored, transported, and disposed of while avoiding the need to re-open the canister after initial loading, thus preventing repackaging of the material. A key safety function of this package is to ensure the material maintains a sub-critical configuration for storage, transportation, and disposal. DOE-managed fuels come from a wide range of reactor types, with various cladding materials and enrichments. Many of these reactors, now decommissioned, had unique design features, such as core configuration, fuel element and assembly geometry, moderator and coolant materials, operational characteristics, and neutron spatial and spectral properties resulting in a large diversity of reactor and fuel designs. To adequately address the diversity of DOE spent nuclear fuel (SNF), a number of basket were designed. The basket material needed to have the ability to ensure subcriticality, be structurally sound, and be corrosion resistant. One such option that was investigated in the late-1990s through mid-2000s was a corrosion-resistant, nickel-chromium-molybdenum alloy containing gadolinium, which was termed the advanced neutron absorber (ANA). A number of analyses were performed to verify the structural, corrosive properties, and neutron absorption performances of this material as well as to compare other potential materials to be used for the basket. Gadolinium-containing carbon steel and borated stainless steel were also considered and evaluated. Boral was briefly considered, but due to its corrosive properties. Each of the evaluated materials have strengths and weaknesses. ANA is the best thermal neutron absorber but lacks confirmatory research for corrosion and weldability. Gadolinium containing carbon steel provides excellent moderator exclusion capabilities but does not contain a sufficient supply of phosphate to ensure the gadolinium precipitates. To minimize the probability of a critical configuration, it is highly desirable for the gadolinium to precipate the probability that the materials will remain within the waste packages over the postclosure time periods of interest. Borated stainless steel has structural integrity and impressive corrosion resistance in most environments, but can undergo galvanic corrosion when in close proximity/contact with aluminum and may experience less than desirable corrosion resistance. This report provides an extensive list and comparison of the materials evaluated to ensure sub-criticality of DOE standardized canister in all credible scenarios. More analyses need to be performed using new and updated corrosion information to re-evaluate the neutron absorber that best meets the objectives of the DOE standardized canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Search for Channel Deformation in Irradiated Vanadium Tensile Specimens

A miniature tensile specimen of V-4Cr-4Ti which had be irradiated in the 17J test at 425°C to 3.7 dpa was mechanically polished, deformed to 3.9% strain at room temperature, and examined by scanning and transmission electron microscopy in order to look for evidence of channel deformation. It was found that uniform deformation can occur without channel deformation, but evidence for channeling was found with channels appearing most prominently after the onset of necking. The channeling occurs on wavy planes with large variations in localized deformation from channel to channel.

36 MATERIALS SCIENCE↗

NON-DESTRUCTIVE POST IRRADIATION EXAMINATION OF FIRST CYCLE ACCIDENT TOLERANT AND ADVANCED ZIRCONIUM ALLOY HIGH BURNUP FUEL RODS

Post irradiation examination (PIE) of accident tolerant fuel concepts and high burnup uranium dioxide advanced zirconium alloy clad fuel contribute to near term nuclear industry goals of enhancing light water reactor safety and economics. Westinghouse is developing chromium coated zirconium alloy cladding as an accident tolerant fuel option for current pressurized water reactors. Examination of high burnup fuel further augments the technical foundation for extending the peak rod average burnup limits beyond the current regulatory limit of 62 MWd/kgU. Seven fuel rods were received at the Oak Ridge National Laboratory Irradiated Fuel Examination Facility. This includes three chromium coated zirconium alloy fuel rods and four high burnup advanced zirconium alloy fuel rods. Six of the seven rods were fueled with standard uranium dioxide while one of the chromium coated rods contained Westinghouse’s ADOPT fuel. The overall hot-cell PIE plan and some PIE results have been presented previously. This paper focuses on the additional non-destructive examination and fission gas release. Highlights from visual examination of these rods are presented. The chromium coating showed little to no visual change following irradiation. Observations of the axial burnup trends in the fuel rods are derived from full rod axial gamma-ray scans with additional observations related to local fission product migration. The axial dimensional changes of the seven rods are evaluated. As expected, creep down had not yet occurred in the chromium coated rods, and the maximum diameter strain in the high burnup advanced zirconium alloy cladding was less than 0.5%. Finally, the steady state fission gas release for these rods was measured ranging from 4.1% to 17.6% which matched expectation from literature. These fuel rods now await further destructive examination.

Harp, Jason↗

Impact of neutron irradiation on mechanical performance of FeCrAl alloy laser-beam weldments

Oxidation-resistant iron-chromium-aluminum (FeCrAl) alloys demonstrate better performance in Loss-of-Coolant Accidents, compared with austenitic- and zirconium-based alloys. However, further deployment of FeCrAl-based materials requires detailed characterization of their performance under irradiation; moreover, since welding is one of the key operations in fabrication of light water reactor fuel cladding, FeCrAl alloy weldment performance and properties also should be determined prior to and after irradiation. In this paper, advanced C35M alloy (Fe-13%Cr-5%Al) and variants with aluminum (+2%) or titanium carbide (+1%) additions were characterized after neutron irradiation in Oak Ridge National Laboratory's High Flux Isotope Reactor at 1.8–1.9 dpa in a temperature range of 195–559 °C. Specimen sets included as-received (AR) materials and specimens after controlled laser-beam welding. Tensile tests with digital image correlation (DIC), scanning electron microscopy-electron back scatter diffraction analysis, fractography, and x-ray tomography analysis were performed. DIC allowed for investigating local yield stress in the weldments, deformation hardening behavior, and plastic anisotropy. Finally, both AR and welded material revealed a high degree of radiation-induced hardening for low-temperature irradiation; however, irradiation at high-temperatures (i.e., 559 °C) had little overall effect on the mechanical performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Corrosion behavior of ferritic FeCrAl alloys in simulated BWR normal water chemistry

Ferritic iron-chromium-aluminum (FeCrAl) alloys with varying Cr content were subjected to in-situ irradiation-corrosion with energetic protons or electron beams in pure water with various oxygen concentrations. Oxide microstructure and composition were characterized to compare the corrosion under irradiation with the thermal corrosion in the same water conditions. The dominant effect seems to be the production of H 2 O 2 at the surface by the intense proton and electron beams. The corrosion potential of FeCrAl under BWR-NWC condition is somewhat above the Cr 2 O 3 /CrO 4 2- phase boundary, oxidizing the Cr(III) to Cr(VI) in the outer part of the film, but with some Cr(III) remaining in the interior of the oxide. The beam increases the corrosion potential, significantly reducing Cr(III) content throughout the oxide. Finally, the crystallites on the surface, which form by re-precipitation from solution, do not contain Cr because at low potential Cr(III) is not soluble, and at high potential Cr(VI) is quite soluble.

36 MATERIALS SCIENCE↗

Effect of surface oxides on tritium entrance and permeation in FeCrAl alloys for nuclear fuel cladding: a review

Abstract Iron-chromium-aluminum (FeCrAl) alloys are being considered for the cladding of uranium dioxide fuel in light water reactors (LWRs). FeCrAl alloys have good mechanical properties at temperatures of 300 °C and higher, and have superlative resistance to attack by steam at temperatures of up to 1000 °C and higher. A concern has been raised that the use of FeCrAl for cladding would result in a higher content of tritium in the reactor coolant as compared with the current system where the cladding is a zirconium based alloy. This review shows that the flux of tritium from the fuel rod cavities to the coolant across the fuel cladding wall will be greatly reduced by the presence of oxides on the surface of the cladding. The review of current literature and permeation data show that (a) protective oxides are expected to be present on both sides of the FeCrAl cladding, and (b) depending on the characteristics of these oxide layers it is reasonable to expect about two–three orders of magnitude reduction in tritium permeation, relative to the permeation response in clean, unoxidized condition for FeCrAl steels of interest, around 277 °C–377 °C temperatures.

Electrochemistry↗

Electroplating on titanium alloy

Activation process forms adherent electrodeposits of copper, nickel, and chromium on titanium alloy. Good adhesion of electroplated deposits is obtained by using acetic-hydrofluoric acid anodic activation process.

Lowery, J. R.↗

Development of an in-situ corrosion monitor for molten salt reactors

A novel in-situ corrosion sensor for structural alloys exposed to molten salts has been initially demonstrated. The measurement is based upon observing the change in magnetic susceptibility of salt wetted structural alloys as corrosion occurs. In halide salts corrosion of structural alloys proceeds primarily through dissolution of the least noble component of the alloy into the melt. All currently available structural alloys intended for use with molten salt reactors (MSRs) include nickel, chromium, and iron. Chromium is preferentially oxidized from the alloy surface by exposure to halide salts at high temperature. Diffusion within the alloy results in progressively deeper depletion of chromium from the alloy surface. Relevant chromium bearing structural alloys are paramagnetic. However, once the chromium has been depleted, they become ferromagnetic. Thus, structural alloy corrosion in an MSR results in development of a ferromagnetic surface layer whose depth increases with increasing corrosion. The corrosion sensor functions by employing the progressive increase in ferromagnetism as a transduction mechanism through including the corroding alloy in a magnetic circuit. Development of the sensor remains a work in progress. To date we have characterized the sensor response of structural alloy samples with varying degrees of corrosion at room temperature. Over the next year we plan to demonstrate sensor performance at MSR operating temperatures (up to 750 °C) in a piping geometry.

Holcomb, David↗