Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CFD simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Response surface data for sensitivity study of industrial spray injected fluidized bed reactor

An industrial fluidized bed reactor was designed to convert an aqueous solid laden stream into a consistent granular product. CFD simulations were run using the MFiX two-fluid model for this fluidizing bed operating at 650 °C. A set of simulations were run over a Latin-hypercube sample of five model parameters – bed particle size, bed particle density, coal particle size, spray feed flow rate, and fluidizing gas flow rate. Data from the simulations were collected on three quantities of interest – bed differential temperature, low solids velocity, and bed voidage. The data presented here is the full span of response surfaces generated using the process Gaussian response surface model in the Dakota code, as well as the table of data for coefficients of the fitted model. The fits to the five-dimensional Gaussian Process models were 0.7797, 0.8664, and 0.9440 for the temperature, velocity, and solids packing, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comprehensive Model of Single Particle Pulverized Coal Combustion Extended to Oxy-Coal Conditions

Oxy-fired coal combustion is a promising potential carbon capture technology. Predictive CFD simulations are valuable tools in evaluating and deploying oxy-fuel and other carbon capture technologies either as retrofit technologies or for new construction. But, accurate predictive simulations require physically realistic submodels with low computational requirements. In particular, comprehensive char oxidation and gasification models have been developed that describe multiple reaction and diffusion processes. Our work extends a comprehensive char conversion code (CCK), which treats surface oxidation and gasification reactions as well as processes such as film diffusion, pore diffusion, ash encapsulation, and annealing. In this work several submodels in the CCK code were updated with more realistic physics or otherwise extended to function in oxy-coal conditions. Improved submodels include the annealing model, the swelling model, the mode of burning parameter, and the kinetic model, as well as the addition of the chemical percolation devolatilization (CPD) model. We compare our results of the char combustion model to oxy-coal data, and further compared to parallel data sets near conventional conditions. A potential method to apply the detailed code in CFD work is given.

01 COAL, LIGNITE, AND PEAT↗

Increasing EDV Range through Intelligent Cabin Air Handling Strategies: Annual Progress Report

Computational fluid dynamics (CFD) simulations of a Ford Focus Electric demonstrated that a split flow heating, ventilating and air conditioning (HVAC) system with rear recirculation ducts can reduce cabin heating loads by up to 57.4% relative to full fresh air usage under some conditions (steady state, four passengers, ambient temperature of -5 deg C). Simulations also showed that implementing a continuous recirculation fraction control system into the original equipment manufacturer (OEM) HVAC system can reduce cabin heating loads by up to 50.0% relative to full fresh air usage under some conditions (steady state, four passengers, ambient temperature of -5 deg C). Identified that continuous fractional recirculation control of the OEM system can provide significant energy savings for EVs at minimal additional cost, while a split flow HVAC system with rear recirculation ducts only provides minimal additional improvement at significant additional cost.

33 ADVANCED PROPULSION SYSTEMS↗

New Insights for Improving the Designs of Flexible Duct Junction Boxes (Fact Sheet)

IBACOS explored the relationships between pressure and physical configurations of flexible duct junction boxes by using computational fluid dynamics (CFD) simulations to predict individual box parameters and total system pressure, thereby ensuring improved HVAC performance. Current Air Conditioning Contractors of America (ACCA) guidance (Group 11, Appendix 3, ACCA Manual D, Rutkowski 2009) allows for unconstrained variation in the number of takeoffs, box sizes, and takeoff locations. The only variables currently used in selecting an equivalent length (EL) are velocity of air in the duct and friction rate, given the first takeoff is located at least twice its diameter away from the inlet. This condition does not account for other factors impacting pressure loss across these types of fittings. For each simulation, the IBACOS team converted pressure loss within a box to an EL to compare variation in ACCA Manual D guidance to the simulated variation. IBACOS chose cases to represent flows reasonably correlating to flows typically encountered in the field and analyzed differences in total pressure due to increases in number and location of takeoffs, box dimensions, and velocity of air, and whether an entrance fitting is included. The team also calculated additional balancing losses for all cases due to discrepancies between intended outlet flows and natural flow splits created by the fitting. In certain asymmetrical cases, the balancing losses were significantly higher than symmetrical cases where the natural splits were close to the targets. Thus, IBACOS has shown additional design constraints that can ensure better system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Natural Circulation Patterns in the VHTR Air-Ingress Accident and Related Issues

Natural circulation patterns in the VHTR during a hypothetical air-ingress accident have been investigated using computational fluid dynamic (CFD) methods in order to compare results from the previous 1-D model which was developed using GAMMA code for the air-ingress analyses. The GT-MHR 600 MWt reactor was selected to be the reference design and modeled by a half symmetric 3-D geometry using FLUENT 6.3, a commercial CFD code. CFD simulations were carried out as the steady-state calculation, and the boundary conditions were either assumed or provided from the 1-D GAMMA code results. Totally, 12 different cases have been reviewed, and many notable results have been obtained through in this work. According to the simulations, natural circulation patterns in the reactor were quite different from the previous 1-D assumptions. A large re-circulation flow with thermal stratification phenomena was clearly observed in the hot-leg and the lower plenum in the 3-D model. This re-circulation flow provided about an order faster air-ingress speed (0.46 m/s in superficial velocity) than previously predicted by 1-D modeling (0.02~0.03 m/s). It indicates that the 1-D air-ingress modeling may significantly distort the air-ingress scenario and consequences. In addition, complicated natural circulation patterns are eventually expected to result in very complex graphite oxidations and corrosion behaviors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

aphBO-2GP-3B: a budgeted asynchronous parallel multi-acquisition functions for constrained Bayesian optimization on high-performing computing architecture

High-fidelity complex engineering simulations are often predictive, but also computationally expensive and often require substantial computational efforts. The mitigation of computational burden is usually enabled through parallelism in high-performance cluster (HPC) architecture. Optimization problems associated with these applications is a challenging problem due to the high computational cost of the high-fidelity simulations. In this paper, an asynchronous parallel constrained Bayesian optimization method is proposed to efficiently solve the computationally expensive simulation-based optimization problems on the HPC platform, with a budgeted computational resource, where the maximum number of simulations is a constant. The advantage of this method are three-fold. Firstly, the efficiency of the Bayesian optimization is improved, where multiple input locations are evaluated parallel in an asynchronous manner to accelerate the optimization convergence with respect to physical runtime. This efficiency feature is further improved so that when each of the inputs is finished, another input is queried without waiting for the whole batch to complete. Second, the proposed method can handle both known and unknown constraints. Third, the proposed method samples several acquisition functions based on their rewards using a modified GP-Hedge scheme. The proposed framework is termed aphBO-2GP-3B, which means asynchronous parallel hedge Bayesian optimization with two Gaussian processes and three batches. The numerical performance of the proposed framework aphBO-2GP-3B is comprehensively benchmarked using 16 numerical examples, compared against other 6 parallel Bayesian optimization variants and 1 parallel Monte Carlo as a baseline, and demonstrated using two real-world high-fidelity expensive industrial applications. The first engineering application is based on finite element analysis (FEA) and the second one is based on computational fluid dynamics (CFD) simulations.

97 MATHEMATICS AND COMPUTING↗

Computational Fluid Dynamics Analysis of Flexible Duct Junction Box Design

IBACOS explored the relationships between pressure and physical configurations of flexible duct junction boxes by using computational fluid dynamics (CFD) simulations to predict individual box parameters and total system pressure, thereby ensuring improved HVAC performance. Current Air Conditioning Contractors of America (ACCA) guidance (Group 11, Appendix 3, ACCA Manual D, Rutkowski 2009) allows for unconstrained variation in the number of takeoffs, box sizes, and takeoff locations. The only variables currently used in selecting an equivalent length (EL) are velocity of air in the duct and friction rate, given the first takeoff is located at least twice its diameter away from the inlet. This condition does not account for other factors impacting pressure loss across these types of fittings. For each simulation, the IBACOS team converted pressure loss within a box to an EL to compare variation in ACCA Manual D guidance to the simulated variation. IBACOS chose cases to represent flows reasonably correlating to flows typically encountered in the field and analyzed differences in total pressure due to increases in number and location of takeoffs, box dimensions, and velocity of air, and whether an entrance fitting is included. The team also calculated additional balancing losses for all cases due to discrepancies between intended outlet flows and natural flow splits created by the fitting. In certain asymmetrical cases, the balancing losses were significantly higher than symmetrical cases where the natural splits were close to the targets. Thus, IBACOS has shown additional design constraints that can ensure better system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Fluid Dynamics Analysis of Flexible Duct Junction Box Design

IBACOS explored the relationships between pressure and physical configurations of flexible duct junction boxes by using computational fluid dynamics (CFD) simulations to predict individual box parameters and total system pressure, thereby ensuring improved HVAC performance. Current Air Conditioning Contractors of America (ACCA) guidance (Group 11, Appendix 3, ACCA Manual D, Rutkowski 2009) allows for unconstrained variation in the number of takeoffs, box sizes, and takeoff locations. The only variables currently used in selecting an equivalent length (EL) are velocity of air in the duct and friction rate, given the first takeoff is located at least twice its diameter away from the inlet. This condition does not account for other factors impacting pressure loss across these types of fittings. For each simulation, the IBACOS team converted pressure loss within a box to an EL to compare variation in ACCA Manual D guidance to the simulated variation. IBACOS chose cases to represent flows reasonably correlating to flows typically encountered in the field and analyzed differences in total pressure due to increases in number and location of takeoffs, box dimensions, and velocity of air, and whether an entrance fitting is included. The team also calculated additional balancing losses for all cases due to discrepancies between intended outlet flows and natural flow splits created by the fitting. In certain asymmetrical cases, the balancing losses were significantly higher than symmetrical cases where the natural splits were close to the targets. Thus, IBACOS has shown additional design constraints that can ensure better system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A two-phase substrate model for enzymatic hydrolysis of lignocellulose: application to batch and continuous reactors

Abstract Background Enzymatic hydrolysis continues to have a significant projected production cost for the biological conversion of biomass to fuels and chemicals, motivating research into improved enzyme and reactor technologies in order to reduce enzyme usage and equipment costs. However, technology development is stymied by a lack of accurate and computationally accessible enzymatic-hydrolysis reaction models. Enzymatic deconstruction of cellulosic materials is an exceedingly complex physico-chemical process. Models which elucidate specific mechanisms of deconstruction are often too computationally intensive to be accessible in process or multi-physics simulations, and empirical models are often too inflexible to be effectively applied outside of their batch contexts. In this paper, we employ a phenomenological modeling approach to represent rate slowdown due to substrate structure (implemented as two substrate phases) and feedback inhibition, and apply the model to a continuous reactor system. Results A phenomenological model was developed in order to predict glucose and solids concentrations in batch and continuous enzymatic-hydrolysis reactors from which liquor is continuously removed by ultrafiltration. A series of batch experiments were performed, varying initial conditions (solids, enzyme, and sugar concentrations), and best-fit model parameters were determined using constrained nonlinear least-squares methods. The model achieved a good fit for overall sugar yield and insoluble solids concentration, as well as for the reduced rate of sugar production over time. Additionally, without refitting model coefficients, good quantitative agreement was observed between results from continuous enzymatic-hydrolysis experiments and model predictions. Finally, the sensitivity of the model to its parameters is explored and discussed. Conclusions Although the phenomena represented by the model correspond to behaviors that emerge from clusters of mechanisms, and hence a set of model coefficients are unique to the substrate and the enzyme system, the model is efficient to solve and may be applied to novel reactor schema and implemented in computational fluid dynamics (CFD) simulations. Hence, this modeling approach finds the right balance between model complexity and computational efficiency. These capabilities have broad application to reactor design, scale-up, and process optimization.

09 BIOMASS FUELS↗

Applying a Compact Porous Media Model to Numerically Derive Resistance Coefficients for Lattice Structures

Additive Manufacturing allows for exploring various geometries to achieve specific engineering criteria. Lattices are one geometry with unique properties, including being periodically repeating structures which allow flow through them to be represented as a porous media according to Darcy-Forchheimer equations. These equation’s coefficients are generally experimentally derived, but this work demonstrates the ability to numerically derive them with CFD. Simulations were performed using three-dimensional stead state Reynolds-averaged Navier-Stokes with a k-ω Shear Stress Transport turbulence model using Ansys Fluent. Three lattice geometries were investigated and drag coefficients were derived. The method was validated against externally published data for similar geometries demonstrating strong agreement, and grid convergence for all simulations was calculated with a Grid Convergence Index method. Wall roughness is demonstrated to have a non-negligible impact on results and roughness values are considered for the primary focus Octahedral geometry where both smooth wall and rough wall coefficients were derived. The porosity coefficients for the Octahedral geometry at 1.0 [m/s] were found to be 2.89×10 6 and 2.90×10 6 [1/(Pa*m*s)] for the permeability coefficients, 6.37×10 1 and 5.44×10 1 [m 2 /kg] for the inertial resistance coefficients, and with a max pressure drop of 5116.7 [Pa] and 4429.5 [Pa] for the smooth walls and rough walls, respectively. The derived numerical method enables rapid exploration and optimization of new lattice designs for diverse engineering applications.

42 ENGINEERING↗

Energy Efficiency of Distributed Environmental Control Systems

In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the resulting temperature stratification. These simulations showed that the advective flow between cubicles is very significant and severely limits the occupants’ ability to control the personal micro-environments by simply controlling the temperature of the incoming air. Subsequently, the existing thermal-circuit model was extended to include the phenomena described above. The modifications to the thermal-circuit model, which were incorporated such that the simulation time was only slightly impacted, showed that accounting for room stratification resulting from the use of floor swirl diffusers could lead to 10%-26% reduction in the annual energy consumed for HVAC in non-temperate climates. This trend was evident in both OSFA and HIYW scenarios. However, the ratio of energy usage in the two scenarios was little affected by the enhancements in the thermal model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Produced Water and Waste Heat-aided Blowdown Water Treatment: Using Chemical and Energy Synergisms for Value Creation

The project objective was to develop a cooling blowdown water (BDW) treatment process utilizing produced water (PW) and low-grade heat to maximize water reuse and saleable by-product generation while reducing chemical and energy footprints of the treatment. The proposed treatment process consists of mixing, softening, organics and suspended solids removal, reverse osmosis (RO), thermal desalination, and brine electrolysis. BDW samples collected from a local coal-fired power plant and PW samples from two shale gas production wells were used in this study. Each treatment unit was first designed and tested to quantify its treatment efficiency, and its chemical and energy requirements. In addition, a process model was developed and model simulations were conducted based on the experimental results and literature data to optimize the treatment process. A techno-economic analysis was conducted to quantify chemical and energy savings as well as production of 10-lb brine as a saleable product. With the field-collected BDW and PW samples, mixing experiments determined a volumetric mixing ratio 10:1 (BDW:PW) resulted in the best performance of multivalent ions removal and largest chemical savings for softening. Softening of the BDW/PW mixtures using alkaline chemicals (Na 2 CO 3 and NaOH) achieved 95%-100% removal of scaling-forming cations (Ca, Mg, Fe, Ba, Sr) and 60% of silicon, and 10% of total organic carbon (TOC). The mixing and softening treatments yielded an effluent with total dissolved solids (TDS) concentration of 23 g/L. Activated carbon (AC) filtration removed TOC to a low level (< 3 mg/L) and further removed remaining scale-forming divalent metals and silica from the softened water. The AC filtration resulted in a slight reduction of TDS from 23 g/L to 20 g/L, leaving behind only mostly monovalent ions (i.e., sodium and chloride) in the filtered water. These pretreatments yielded a feed water that met the criteria of the downstream reverse osmosis (RO) to prevent membrane fouling. A cross-flow RO system was used to further concentrate the TDS of the AC effluent. Various factors including TDS, pH, and applied pressure were examined and optimal conditions were determined for the co-treatment process. An integrated process consisting of mixing, softening, AC filtration and RO was used to treat a continuous flow (0.25 – 1.2 L/min, or 0.07 – 0.32 gpm) and successfully generated RO permeate as product water (TDS < 0.5 g/L) for reuse in cooling operation, and a concentrate (TDS ~ 45 g/L) to be further treated in a thermal desalination unit. These flow rates meet the FOA’s criterion of 0.01 – 1 gpm. Overall, the co-treatment of BDW/PW allowed shorter ramp-up time compared to treatment of BDW alone. It resulted in 40% and 55% savings of Na 2 CO 3(s) and NaOH, respectively, compared to treating the BDW and PW individually for the same level of softening. The co-treatment also resulted in a 29% energy saving compared to treatment of BDW only for the level of TDS concentration. A thermal desalination system was designed using CFD simulations and manufactured in the WVU Innovation Hub for further treatment of the RO concentrate to generate 10-lb brine. The system has a design flow rate of 2 gpm and has been successfully tested. A bench-scale brine electrolysis system was developed for on-site generation of chlorine/hypochlorite (Cl 2 /OCl - ) and caustic soda (NaOH) as useful chemicals for the co-treatment process. Using salt solutions (0.5 M and 1 M), the system achieved faradaic efficiencies of 93%-97% and 70%-77% for caustic soda and chlorine/hypochlorite generation, respectively. An economic analysis showed that the electricity costs for on-site generation of these chemicals were significantly lower than the chemical prices offered by suppliers. An industrial-scale process model consisting of mixing, softening, AC filtration, RO, thermal desalination, and brine electrolysis was developed using the Aspen Plus V9 in conjunction with Aspen Custom Modeler V9. The model serves as a solvable Aspen Plus model and as basis to form the costing infrastructure. In addition, techno-economic analysis considering capital, operating, and transportation costs was conducted. An optimization solution showed that produced water for mixing is still advantageous in low quantities. The optimum solution approaches a leveled cost of water (LCW) of 2 $/m 3 which becomes cost competitive with nominal water treatment prices.

20 FOSSIL-FUELED POWER PLANTS↗

A study on the scale dependence of mixing indices for Eulerian multiphase models

Abstract Mixing can vary based on the scale at which the system is observed, and a mixing index that can capture the features at different length scales is desirable. In this article, we analyze the scale dependence of the mixing indices developed for Eulerian multiphase models. Relevant length scales are distinguished by filtering solid fraction fields. The scale‐dependence study is first done on manufactured fields of solid fraction to assess the performance of the mixing indices. The study is extended to a two‐dimensional CFD simulation of the segregation of a bidisperse gas–solid mixture. The local mixing index performs well in capturing the spatial variation of mixing at different scales. The scale dependence of two global mixing indices is considered in the study, where the state of mixing is defined based on statistical measures. We demonstrate that the choice of measures influences the sensitivity of mixing indices to mixing at different scales.

Nagawkar, Barlev R.↗

Towards Adaptive Mesh Refinement for the Spectral Element Solver Nek5000

When performing computational fluid dynamics (CFD) simulations of complex flows, the a priori knowledge of the flow physics and the location of the dominant flow features are usually unknown. For this reason, the development of adaptive remeshing techniques is crucial for large-scale computational problems. Some work has been made recently to provide Nek5000 with adaptive mesh refinement (AMR) capabilities in order to facilitate the generation of the grid and push forward the limit in terms of problem size and complexity [10]. Nek5000 is an open-source, highly scalable and portable code based on the spectral element method (SEM) [4], which offers minimal dissipation and dispersion, high accuracy and exponential convergence. It is aimed at solving direct and large-eddy simulations of turbulent incompressible or low Mach-number flows with heat transfer and species transport. The approach chosen for adapting the mesh is the h-refinement method, where elements are split locally, which requires the relaxation of the conforming grid constraint currently imposed by Nek5000. Other challenges include the implementation of an efficient management of the grid as refinement is applied, the development of tools to localize the critical flow regions via error estimators and the extension of the current preconditioning strategy to non-conforming grids. In this paper, we present a new procedure to setup an algebraic multigrid solver used as part of the preconditioner for the pressure equation.

Offermans, N.↗

PowderJet: Spherical metal powder production via multi-orifice droplet-on-demand metal jetting

Leading metal additive manufacturing techniques, such as laser powder bed fusion and directed energy deposition, rely on high-quality spherical metal powders. However, traditional powder production methods like gas atomization face limitations, including low in-spec yield, asphericity, and internal porosity. We introduce PowderJet, a powder production platform that uses electromagnetic pulses to eject liquid metal droplets from a multi-orifice nozzle. Unlike stochastic methods, PowderJet tightly controls powder size, distribution, and purity through a droplet-on-demand approach. We detail the system’s design, operation, and performance using a combined experimental and computational fluid dynamics (CFD) framework. Initial results with Al4008 and Cu110 alloys demonstrate successful production, yielding unsieved aluminum powder batches with a mean diameter of 200 µm and a narrow size distribution (15 µm standard deviation). The produced powders are highly spherical, achieving a roundness > 0.95. PowderJet operates with a small melt volume (3 mL) and supports continuous refilling, enabling production rates between 30 and 140 cm³/hr depending on jetting frequency, number of orifices and particle size. CFD simulations show that future systems could achieve rates exceeding 1000 cm³/hr for particle sizes as small as 40 µm. PowderJet’s high yield of in-spec powder makes it ideal for producing precious or hazardous materials that are inefficient to manufacture using conventional methods. This platform offers a scalable, precise, and efficient solution for producing high-quality powders tailored for advanced manufacturing applications.

Atomization↗

Passive decay heat removal system design for the integral inherent safety light water reactor (I 2 S-LWR)

The Integral, Inherently Safe Light Water Reactor (I 2 S-LWR) is an innovative Pressurized Water Reactor (PWR) concept being developed by a multi-institutional team led by Georgia Tech and in collaboration with Westinghouse, under the Department of Energy’s Nuclear Energy University Programs Integrated Research Projects (DOE NEUP IRP). The University of Michigan leads the design of the thermalhydraulic and passive safety systems, in collaboration with Westinghouse and Bringham Young University. The I 2 S-LWR features an integral primary system configuration and is more conducive to the implementation of inherent safety features by eliminating potential accidents. In this paper, a novel passive Decay Heat Removal System (DHRS), is presented, consisting of a primary loop, an intermediate loop and a cooling tower loop. This passive system is designed to remove the I 2 S-LWR decay heat in the case of emergency heat removal transients, without the need for external power or operator action. The proposed DHR uses atmosphere as ultimate heat sink, to achieve indefinite decay heat removal. In this paper, firstly, the design of primary and secondary DHRS heat exchangers is optimized. Then the DHR heat removal characteristics are studied using the best-estimate thermal hydraulic code RELAP5. In addition, CFD simulations have been performed in order to investigate the DRHS helical coil primary heat exchanger performance with different coil pipe arrangements, and optimize its design. The performance of the proposed DHRS concept is investigated in case of a Station Black-Out (SBO) scenario. Operation of two, three and four DHRS trains is studied respectively. The findings show that three out of four DHRS trains are sufficient to indefinitely remove the core decay heat successfully during a SBO, and keep the reactor in a safe state without the need of any other auxiliary active system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A new predictive multi-zone model for HCCI engine combustion

Here, this work introduces a new predictive multi-zone model for the description of combustion in Homogeneous Charge Compression Ignition (HCCI) engines. The model exploits the existing OpenSMOKE++ computational suite to handle detailed kinetic mechanisms, providing reliable predictions of the in-cylinder auto-ignition processes. All the elements with a significant impact on the combustion performances and emissions, like turbulence, heat and mass exchanges, crevices, residual burned gases, thermal and feed stratification are taken into account. Compared to other computational approaches, this model improves the description of mixture stratification phenomena by coupling a wall heat transfer model derived from CFD application with a proper turbulence model. Furthermore, the calibration of this multi-zone model requires only three parameters, which can be derived from a non-reactive CFD simulation: these adaptive variables depend only on the engine geometry and remain fixed across a wide range of operating conditions, allowing the prediction of auto-ignition, pressure traces and pollutants. This computational framework enables the use of detail kinetic mechanisms, as well as Rate of Production Analysis (RoPA) and Sensitivity Analysis (SA) to investigate the complex chemistry involved in the auto-ignition and the pollutants formation processes. In the final sections of the paper, these capabilities are demonstrated through the comparison with experimental data.

30 DIRECT ENERGY CONVERSION↗

Piston geometry and stroke optimization for high efficiency propane spark ignition engines

Propane has unique properties and offers interesting characteristics for high-efficiency spark ignition engines. Its high volatility reduces or completely eliminates fuel-wall wetting and facilitates fuel air mixing. Furthermore, propane has a research octane number of 112 and a high octane sensitivity of 15. Finally, its laminar flame speed is on the same order as that of conventional gasoline, and it exhibits high dilution tolerance. Modern spark ignition internal combustion engines rely on fast combustion rates and high dilution to achieve high brake thermal efficiencies. To accomplish this, high stroke-to-bore ratios and high geometric compression ratios have been used in new engine designs. Therefore, propane’s relatively high laminar flame speeds, high knock resistance, and dilution tolerance make it an excellent candidate fuel for modern spark ignition engines. The objective of this work is to co-optimize the piston geometry and the engine stroke to maximize the efficiency of a spark-ignition engine fueled with propane. 3D computational fluid dynamics (CFD) simulations employing the extended coherent flamelet model were used to study the parametric effects of piston shape and stroke length. A piston geometry based on high performing pistons was parameterized using four controlling parameters. The piston geometry and engine stroke design space was explored using deterministic and quasi-random sampling techniques. In conclusion, a Gaussian process regression model was built using the simulation data to explain the results observed.

33 ADVANCED PROPULSION SYSTEMS↗