Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CESIUM ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Vitrification of Hanford Tank Waste 241-AP-105 in a Continuous Laboratory-Scale Melter

Low-activity waste (LAW) stored in underground tanks on the Hanford site in Washington State is planned to be filtered for solids removal and processed through ion exchange columns for cesium removal at the Low-Activity Waste Pretreatment System facility. These pretreatment steps will allow the waste to be transferred to the Hanford Tank Waste Treatment and Immobilization Plant LAW facility for immobilization into glass. The liquid waste will be combined with glass-forming chemicals (GFCs) to form a waste feed slurry that can be fed to electric melters for vitrification. The process of continuously converting the aqueous feed slurry into a melt is dynamic and includes multiple reactions, degassing, and dissolution processes that depend on heat from the melt below. In this conversion process, waste components are partitioned into one of two streams: glass and off-gas. Processing information and chemical information associated with these waste product streams has been requested by Washington River Protection Solutions for actual tank waste from tank 241-AP-105 (referred to as AP-105). To acquire this type of information, a small-scale melter system was desired that would not require high volumes of input waste or the large resource commitment of a full-scale melter system, while also providing dynamic information that would be difficult to determine from batch reactions in a crucible system. A continuous laboratory-scale melter (CLSM), has been designed to operate with a continuous feeding process, while periodically pouring glass product and collecting off-gas. The CLSM vessel has been sized to collect the relevant process and chemical information from obtainable volumes of AP-105 waste samples. Two CLSMs were constructed: one in a non-radioactive environment for processing waste simulants and another in a fume hood capable of handling radioactive material for processing actual Hanford tank waste. This dual-system setup allowed for comparison between simulated and real tank waste with essentially identical test equipment. AP-105 waste simulant was first tested in the non-radioactive CLSM to determine the processability and desired operating window for the actual tank waste. Rhenium (Re) was added to the simulant to act as a surrogate for technetium-99 ( 99 Tc), a key waste component found in the actual tank waste. The partitioning of Re into the glass and off-gas products during the continuous feeding of simulant was determined, which allowed the Re retention, the mass flow rate of Re out of the CLSM via the glass product with respect to the mass flow rate of Re into the CLSM via the feed slurry, to be calculated. Key processing results and the average Re retention, from the CLSM test run with AP-105 simulant feed slurry are shown in Table ES.1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of inorganic ion exchange media

The primary objective of these tests outlined in the Test Plan for this work [15] and described herein was to demonstrate the vitrification of ion exchange media for cesium removal, either alone or in combination with a representative Hanford HLW stream. This included one formulation with chabazite as the only waste component and two formulations containing direct-feed fully washed AY-102 HLW solids combined with either CST or chabazite. Feed processing characteristics, glass production rate, melter emissions, and feed carryover were determined for each of the three feed compositions. This was accomplished through VGF and DM100 melter system testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced thermionic converter developments with microwave external pumping

This work reports ion generation in a cesium thermionic converter as part of advanced-model thermionic converter development research. A microwave with frequency in the range between 1-2 GHz is used to externally pump a thermionic converter as part of our effort in the verification of Lam's theory. It is found that the motive peak as predicted in the theory disappears whenever microwave power is used to excite the cesium plasma of the converter. The electron temperature is effectively heated by the microwave and the experimental data agrees with theory in the low-power output region.

Chiu, H. S.↗

Recent Performance and Ignition Tests of the pulsed SNS H- Source for 1-MW Neutron Production

After acquiring several reliable spare targets, SNS ramped the beam power from 850 kW to 1.4 MW, which required an increase in H- beam pulse length from 0.88 to 1.0 ms at 60 Hz. This increase initially produced slow 2-MHz power ramp-ups and, after several weeks of uninterrupted operation, it produced plasma outages every time the pulse length was raised above ~0.95 ms. Similar outages were previously observed towards the end of long service cycles, which were believed to indicate that the breakdown voltage of the high purity hydrogen started to exceed the induced electric fields. In 2011 the RF was reconfigured to start with 10 cycles of 1.96 MHz, which yielded the shortest H- beam rise times and apparently eliminated those plasma outages. The new, pulse-length dependent outages were eliminated by increasing the initial frequency to 1.985 MHz. However, careful frequency studies are unable to justify this frequency. In addition, the paper discusses the issues and solutions for the electron-dump voltage, which starts to sag and become unstable after several weeks of high current operation.

43 PARTICLE ACCELERATORS↗

CST Batch Contact Equilibrium Testing of TCCR Tank 10H Batch 1 and 1A Waste Supernate Samples

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with crystalline silicotitanate media to process radioactive waste solutions for the removal of Cs-137. TCCR currently focuses on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium saltcake solids) within the tank followed by at-tank ion exchange column treatment. Equilibrium batch contact tests conducted in the SRNL Shielded Cells laboratory and associated analyses indicated that both the Tank 10H Batch 1 (pre-production) and 1A (production) waste supernates are unique solutions for which CST cesium removal performance is lower than predicted by ZAM modeling. Cesium distribution coefficients (K d ), percent removal, and CST loading data for the TCCR production supernate batch are provided in Table ES-1. ZAM-based cesium loading predictions are compared to the observed loading for the production batch in Figure ES-1, where significantly lower performance was observed than predicted by the model. Even lower cesium loading results (versus ZAM) were observed previously for the in-tank “teabag” batch contact samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IMPACT OF THE SMALL COLUMN ION EXCHANGE PROCESS ON THE DEFENSE WASTE PROCESSING FACILITY - 12112

The Savannah River Site (SRS) is investigating the deployment of a parallel technology to the Salt Waste Processing Facility (SWPF, presently under construction) to accelerate high activity salt waste processing. The proposed technology combines large waste tank strikes of monosodium titanate (MST) to sorb strontium and actinides with two ion exchange columns packed with crystalline silicotitanate (CST) resin to sorb cesium. The new process was designated Small Column Ion Exchange (SCIX), since the ion exchange columns were sized to fit within a waste storage tank riser. Loaded resins are to be combined with high activity sludge waste and fed to the Defense Waste Processing Facility (DWPF) for incorporation into the current glass waste form. Decontaminated salt solution produced by SCIX will be fed to the SRS Saltstone Facility for on-site immobilization as a grout waste form. Determining the potential impact of SCIX resins on DWPF processing was the basis for this study. Accelerated salt waste treatment is projected to produce a significant savings in the overall life cycle cost of waste treatment at SRS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of feed variability on cesium removal with multiple actual waste samples from the Hanford site

Here, the Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. This lot of material was found to have superior performance in comparison to historic batches of CST. Ion exchange column and batch contact testing with supernate from Hanford tanks AP-105, AP-107 and AW-102 was performed to assess the impact of feed variability on system performance. These tests demonstrated that batch contact measurements provide a reasonable prediction of column capacities with some deviation in performance attributed to column dynamics. In addition, the variability in CST capacity for cesium in the various actual waste samples does not track with historical understanding of the competing cations, suggesting that tank waste samples contain other components that may significantly impact cesium loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NPB Cesium Space Experiment

Neutral Particle Beam (NPB) weapons systems are planned to perform the ballistic missile defense functions of nuclear weapon/decoy discrimination and warhead kill at appropriate energy levels and ion currents. Negatively charged ions are produced in a specialized ion source and focused into a high quality particle beam. NPB linear accelerators accelerate and steer the negatively charged ions using electric and magnetic fields. After acceleration and steering the neutralizer system strips away extra electrons from ions to form the electrically neutral particle beam. The neutral beam then travels through space to the target unaffected by the Earth's magnetic fields. Continuing technological advances have greatly reduced the size and weight of NPB accelerator systems. Ion current production has been enhanced by over 100 percent with the intermittent addition of cesium at the NPB ion source device. This increase in current is essential to attain the most light weight, compact NPB platforms and minimize expensive launch costs. Addition of cesium into the ion source has been identified by the NPB community as the highest priority risk reduction space experiment necessary prior to planned NPB accelerator experiments and later weapons systems. The NPB Cesium Space Experiment is planned to successfully demonstrate controlled cesium introduction and vaporization into a simulated ion source chamber. Microgravity effects on the cesium deposition will be studied as will the effects of small amounts of cesium on high voltage accelerator components that might be susceptible to electrical insulator break downs. The experiment design will simulate as closely as possible the environment, physical and operational characteristics of the actual NPB ion source.

Parsons, George M., III↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs137. TCCR currently focuses on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently-prepared CST media batches (9120- B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant. Simulant batch contact equilibrium cesium loading results for the three CST batches (including two lots of one batch) are provided in Table ES-1. The 35 °C data indicates that the archived IE-911 batch has a higher cesium capacity than recently-prepared CST media and that the minor TCCR CST 9120-B media lot (2099000035) has similar cesium removal performance to the major TCCR lot (2099000034). Tests conducted at 25 ºC for the archived IE-911 CST batch indicated lower cesium removal performance with this simulant batch than was observed recently with a different SRS Average Simulant batch. A dilution factor (DF) is typically utilized when modeling engineered CST media cesium loading performance to account for mass contributions from the binder material. In cases where CST performance is lower than expected, this factor includes corrections for the binder and for low performance. The ZAM (Zheng, Anthony, and Miller) Isotherm Model DF values are provided in Table ES-1 for each simulant batch contact result. DF values near 0.5 were determined for the 9120-B and 9140-B CST batch contact tests while DF values near 0.6 (20% higher) were determined for the tests with IE-911. These dilution factors are lower than recently observed with a different SRS Average Simulant batch (9140-B DF = 0.68; IE-911 DF = 1.0). Based on these results, it appears that some component in the simulant solution used for equilibrium testing may have resulted in reduced cesium loading on the CST media.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural Phase Transition Peculiarities in Ion-Molecular Perchlorate Crystals

Molecular relaxation processes are inspected in potassium and cesium perchlorates (KClO{sub 4} and CsClO{sub 4}, respectively) via Raman spectroscopy. A first-order phase transition in KClO{sub 4} and CsClO{sub 4} crystal perchlorates is found to be extended. A pretransition region is also detected in KClO{sub 4} and CsClO{sub 4} systems, wherein the vibrational band widths are shown to remain almost unchanged, but abruptly increase at the phase transition point.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary Determination of the Impact of Alkaline Earth Metals on Crystalline Silicotitanate

Savannah River Remediation (SRR) recently deployed the Tank Closure Cesium Removal (TCCR) system which utilizes an ion exchange process to remove 137 Cs from tank waste supernate. In TCCR, salt solution is filtered and then passed through ion exchange columns containing crystalline silicotitanate (CST) media, commercially known as UOP IONSIV™ R9120-B, which is highly selective for removing cesium. The current process focuses on dissolving salt in Savannah River Site (SRS) Tank 10H, followed by processing in the TCCR skid located near the tank. Prior to processing each batch of waste generated in Tank 10H, the projected maximum cesium loading on the CST is determined using an in-tank batch contact equilibrium test. This involves placing a small amount (~0.1 g) of CST in a “teabag” device and submerging it in the tank waste for a period of 10 days. Results from those earlier teabag tests had indicated much lower cesium loading than predicted by the equilibrium sorption model (ZAM). There are numerous possible explanations for this result; however, based on the observed loadings of Ca (and other metals) on the CST from the teabag tests, it was hypothesized that competition from these other ions may be limiting the cesium loadings.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The hydrothermal reactions of monosodium titanate, crystalline silicotitanate and sludge in the modular salt process: a literature survey

The use of crystalline silicotitanate (CST) is proposed for an at-tank process to treat High Level Waste at the Savannah River Site. The proposed configuration includes deployment of ion exchange columns suspended in the risers of existing tanks to process salt waste without building a new facility. The CST is available in an engineered form, designated as IE-911-CW, from UOP. Prior data indicates CST has a proclivity to agglomerate from deposits of silica rich compounds present in the alkaline waste solutions. This report documents the prior literature and provides guidance for the design and operations that include CST to mitigate that risk. The proposed operation will also add monosodium titanate (MST) to the supernate of the tank prior to the ion exchange operation to remove strontium and select alpha-emitting actinides. The cesium loaded CST is ground and then passed forward to the sludge washing tank as feed to the Defense Waste Processing Facility (DWPF). Similarly, the MST will be transferred to the sludge washing tank. Sludge processing includes the potential to leach aluminum from the solids at elevated temperature (e.g., 65 C) using concentrated (3M) sodium hydroxide solutions. Prior literature indicates that both CST and MST will agglomerate and form higher yield stress slurries with exposure to elevated temperatures. This report assessed that data and provides guidance on minimizing the impact of CST and MST on sludge transfer and aluminum leaching sludge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-energy beam transport studies supporting the spallation neutron source 1-MW beam operation

The H{sup -} injector consisting of a cesium enhanced RF-driven ion source and a 2-lens electrostatic low-energy beam transport (LEBT) system supports the spallation neutron source 1 MW beam operation with {approx}38 mA beam current in the linac at 60 Hz with a pulse length of up to {approx}1.0 ms. In this work, two important issues associated with the low-energy beam transport are discussed: (1) inconsistent dependence of the post-radio frequency quadrupole accelerator beam current on the ion source tilt angle and (2) high power beam losses on the LEBT electrodes under some off-nominal conditions compromising their reliability.

43 PARTICLE ACCELERATORS↗

Activation behavior for ion permeation in ion-exchange membranes: Role of ion dehydration in selective transport

Here we explored the mechanisms governing the selectivity of anion- and cation-exchange membranes for the transport of four monovalent anions (i.e., fluoride, chloride, bromide, and nitrate) and four monovalent cations (i.e., sodium, potassium, cesium, and ammonium), respectively. Our ion adsorption and transport tests with mixed ion solutions reveal that an ion with larger ionic radius and lower hydration energy is more favorably adsorbed onto the ion-exchange membrane but diffuses more slowly through the polymer matrix compared to an ion with smaller ionic radius and higher hydration energy. Individual anion (as sodium salt) or cation (as chloride salt) permeation tests at different temperatures were performed to evaluate the activation behavior of ion transport through the ion-exchange membranes by calculating the energy barrier and pre-exponential factor (i.e., the ion flux when the energy barrier is negligible) for ion transport from an Arrhenius-type equation. Our results show that an ion with smaller ionic radius and higher hydration energy experiences higher energy barrier (e.g., fluoride, 10.3 kcal mol -1 ) and possesses higher pre-exponential factor compared to an ion with larger ionic radius and lower hydration energy (e.g., bromide, 4.6 kcal mol -1 ). This correlation corroborates our main hypothesis that the activation behavior observed for ion transport is a result of ion dehydration at the water-membrane interface. Our proposed ion selectivity mechanism elucidates how ion dehydration governs the extent of ion permeation into the membrane and the subsequent transport through the charged polymer matrix. Future membrane design that promotes dehydration of target ions is challenging but can result in unprecedented ion selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capture and metathesis-based release of potassium salts by a multitopic ion receptor

Here, we report that the multitopic ion-pair receptor 2 is able to recognize and extract various cesium and potassium salts via three different ion recognition modes. Furthermore, it is capable of extracting and then releasing KNO 3 via ion-pair metathesis with CsClO 4 , allowing KNO 3 recovery.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of plasma grid bias on extracted currents in the RF driven surface-plasma negative ion source

Extraction of negative ions from the large inductively driven surface-plasma negative ion source was studied. The dependencies of the extracted currents vs plasma grid (PG) bias potential were measured for two modifications of radio-frequency driver with and without Faraday screen, for different hydrogen feeds and for different levels of cesium conditioning. The maximal PG current was independent of driver modification and it was lower in the case of inhibited cesium. The maximal extracted negative ion current depends on the potential difference between the near-PG plasma and the PG bias potentials, while the absolute value of plasma potential in the driver and in the PG area is less important for the negative ion production. The last conclusion confirms the main mechanism of negative ion production through the surface conversion of fast atoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗