Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Tensor decomposition in post-Hartree–Fock methods. II. CCD implementation

In a previous publication, we have discussed the usage of tensor decomposition in the canonical polyadic (CP) tensor format for electronic structure methods. There, we focused on two-electron integrals and second order Møller-Plesset perturbation theory (MP2). In this work, we discuss the CP format for Coupled Cluster (CC) theory and present a pilot implementation for the Coupled Cluster Doubles method. We discuss the iterative solution of the CC amplitude equations using tensors in CP representation and present a tensor contraction scheme that minimizes the effort necessary for the rank reductions during the iterations. Furthermore, several details concerning the reduction of complexity of the algorithm, convergence of the CC iterations, truncation errors, and the choice of threshold for chemical accuracy are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CCD SPECKLE OBSERVATIONS OF BINARY STARS WITH THE WIYN TELESCOPE. VI. MEASURES DURING 2007-2008

Results of 974 speckle observations of 546 binary stars are presented. Observations were obtained at the WIYN 3.5 m Telescope at Kitt Peak National Observatory during the time interval from 2007 January to 2008 June. In all cases, the relative separation and position angle of the components are measured, and the magnitude difference is determined in 809 cases. The precision of the results as judged from repeat observations and objects with very well-determined orbits is similar to previous papers in this series, namely {approx}3 mas in separation and <1 deg. in position angle in most cases. Similarly, the photometric precision remains consistent with previous WIYN speckle data, on average {approx}0.1 mag per observation. Six systems of special interest are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

A CCD PHOTOMETRIC STUDY OF THE CONTACT BINARY STAR GSC 03526-01995

We present the first two sets of complete light curves in the R and I bands observed in 2011 and 2012 photometrically for the contact binary GSC 03526-01995. The asymmetric light curves are analyzed with spot models using the Wilson-Devinney code. It is discovered that GSC 03526-01995 is a spotted marginal W-type W UMa contact binary system with a mass ratio of q 2.845({+-} 0.006) and a degree of contact factor f = 18.2%({+-} 1.5%). Combining new determined times of light minimum together with the others published in the literature, the period change of the system is investigated. A cyclic variation, with a period of 7.39 yr and a semiamplitude of 0.00896 days, is discovered. It is plausibly caused by the light-time effect via a third body. The photometric analysis indicates that the suspected third companion might itself be a binary consisting of two stars of 0.285 solar masses, suggesting that GSC 03526-01995 is a quadruple system containing four late-type stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of Pixel Area Variations in Fully Depleted Thick CCD

Future wide field astronomical surveys, like Large Synoptic Survey Telescope (LSST), require photometric precision on the percent level. The accuracy of sensor calibration procedures should match these requirements. Pixel size variations found in CCDs from different manufacturers are the source of systematic errors in the flat field calibration procedure. To achieve the calibration accuracy required to meet the most demanding science goals this effect should be taken into account. The study of pixel area variations was performed for fully depleted, thick CCDs produced in a technology study for LSST. These are n-channel, 100 {micro}m thick devices. We find pixel size variations in both row and column directions. The size variation magnitude is smaller in the row direction. In addition, diffusion is found to smooth out electron density variations. It is shown that the characteristic diffusion width can be extracted from the flat field data. Results on pixel area variations and diffusion, data features, analysis technique and modeling technique are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GafChromic EBT film dosimetry with flatbed CCD scanner: A novel background correction method and full dose uncertainty analysis

Film dosimetry using radiochromic EBT film in combination with a flatbed charge coupled device scanner is a useful method both for two-dimensional verification of intensity-modulated radiation treatment plans and for general quality assurance of treatment planning systems and linear accelerators. Unfortunately, the response over the scanner area is nonuniform, and when not corrected for, this results in a systematic error in the measured dose which is both dose and position dependent. In this study a novel method for background correction is presented. The method is based on the subtraction of a correction matrix, a matrix that is based on scans of films that are irradiated to nine dose levels in the range 0.08-2.93 Gy. Because the response of the film is dependent on the film's orientation with respect to the scanner, correction matrices for both landscape oriented and portrait oriented scans were made. In addition to the background correction method, a full dose uncertainty analysis of the film dosimetry procedure was performed. This analysis takes into account the fit uncertainty of the calibration curve, the variation in response for different film sheets, the nonuniformity after background correction, and the noise in the scanned films. The film analysis was performed for film pieces of size 16x16 cm, all with the same lot number, and all irradiations were done perpendicular onto the films. The results show that the 2-sigma dose uncertainty at 2 Gy is about 5% and 3.5% for landscape and portrait scans, respectively. The uncertainty gradually increases as the dose decreases, but at 1 Gy the 2-sigma dose uncertainty is still as good as 6% and 4% for landscape and portrait scans, respectively. The study shows that film dosimetry using GafChromic EBT film, an Epson Expression 1680 Professional scanner and a dedicated background correction technique gives precise and accurate results. For the purpose of dosimetric verification, the calculated dose distribution can be compared with the film-measured dose distribution using a dose constraint of 4% (relative to the measured dose) for doses between 1 and 3 Gy. At lower doses, the dose constraint must be relaxed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Poster – 13: Evaluation of an in-house CCD camera film dosimetry imaging system for small field deliveries

Purpose: Radiochromic film dosimetry is a standard technique used in clinics to verify modern conformal radiation therapy delivery, and sometimes in research to validate other dosimeters. We are using film as a standard for comparison as we improve high-resolution three-dimensional gel systems for small field dosimetry; however, precise film dosimetry can be technically challenging. We report here measurements for fractionated stereotactic radiation therapy (FSRT) delivered using volumetric modulated arc therapy (VMAT) to investigate the accuracy and reproducibility of film measurements with a novel in-house readout system. We show that radiochromic film can accurately and reproducibly validate FSRT deliveries and also benchmark our gel dosimetry work. Methods: VMAT FSRT plans for metastases alone (PTV{sub MET}) and whole brain plus metastases (WB+PTV{sub MET}) were delivered onto a multi-configurational phantom with a sheet of EBT3 Gafchromic film inserted mid-plane. A dose of 400 cGy was prescribed to 4 small PTV{sub MET} structures in the phantom, while a WB structure was prescribed a dose of 200 cGy in the WB+PTV{sub MET} iterations. Doses generated from film readout with our in-house system were compared to treatment planned doses. Each delivery was repeated multiple times to assess reproducibility. Results and Conclusions: The reproducibility of film optical density readout was excellent throughout all experiments. Doses measured from the film agreed well with plans for the WB+PTV{sub MET} delivery. But, film doses for PTV{sub MET} only deliveries were significantly below planned doses. This discrepancy is due to stray/scattered light perturbations in our system during readout. Corrections schemes will be presented.

60 APPLIED LIFE SCIENCES↗

Scalable Track Detection in SAR CCD Images

Existing methods to detect vehicle tracks in coherent change detection images, a product of combining two synthetic aperture radar images ta ken at different times of the same scene, rely on simple, fast models to label track pixels. These models, however, are often too simple to capture natural track features such as continuity and parallelism. We present a simple convolutional network architecture consisting of a series of 3-by-3 convolutions to detect tracks. The network is trained end-to-end to learn natural track features entirely from data. The network is computationally efficient and improves the F-score on a standard dataset to 0.988, up fr om 0.907 obtained by the current state-of-the-art method.

47 OTHER INSTRUMENTATION↗

Astro Skipper-CCD Detector

Cosmologists have determined that the majority of the universe is composed of dark energy and nonbaryonic (not made of atoms) dark matter. Dark energy is an unknown form of energy, hypothesized to be the cause of the accelerating expansion of the universe. Dark matter can not be detected electromagnetically, however cosmologists are confident it exists because of its gravitational effect on galaxies. In spiral galaxies, we observe stars that orbit at speeds that can not be accounted for by the gravitational force of visible matter. This puzzling result is contrary to standard Newtonian gravity, yet makes sense if one assumes the gravitational effects of an unseen mass[1]. Better, more sensitive detectors are required to perform detailed measurements of faint stars and galaxies that will allow us to further understand these phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗