Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A Hybrid Molecular–Nanophotonic Platform for On-Chip Cavity Quantum Electrodynamics and Collective Interactions

We present a hybrid solid-state cavity quantum electrodynamics (QED) platform that integrates a high density of coherent organic molecules with high-quality-factor nanophotonics. Thin anthracene crystals doped with dibenzoterrylene (DBT) are mechanically transferred onto prefabricated silicon nitride photonic crystal cavities, preserving both the cavity quality and molecular coherence. This approach decouples emitter synthesis from nanofabrication, providing a pathway for integrating other types of emitters. The high density of molecular emitters results in up to ten molecules being coupled to a single cavity. By tuning pairs of molecules into resonance within a single cavity mode, we observe cavity-mediated interactions in both dispersive and dissipative regimes. Furthermore, these results establish an accessible route to deterministic on-chip single- and multiphoton sources.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantum calculations of the cavity shift in electron magnetic moment measurements

The measurement of the anomalous electron magnetic moment g – 2 through quantum transitions of a single trapped electron is the most stringent test of quantum field theory. These experiments are now so precise that they must account for the effects of the cavity containing the electron. Classical calculations of this “cavity shift” must subtract the electron’s divergent self-field, and thus require knowledge of the exact Green’s function for the cavity’s electromagnetic field. We perform the first fully quantum calculation of the cavity shift in a closed cavity, which instead involves subtracting linearly divergent cavity mode sums and integrals. Using contour integration methods, we find perfect agreement with existing classical results for both spherical and cylindrical cavities, justifying their current use. Moreover, our mode-based results can be naturally generalized to account for systematic effects, necessary to push future measurements to the next order of magnitude in precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmic Axion Background detection using resonant cavity arrays

The axion is a well-motivated and generic extension of the Standard Model. If produced in the early universe, axions may still be relativistic today, forming a Cosmic Axion Background (CaB) potentially detectable in direct detection experiments. Although CaB is expected to be broadband, which makes it challenging to be detected, a high-quality-factor microwave cavity acts as a narrowband filter with response peaked at its resonant frequency. We propose a new strategy using multi-cavity arrays to distinguish signal from background noise by exploiting spatial correlations of the axion-induced electric field which are set by the cavity quality factor. We compute the two-point correlation function for electric fields in spatially separated cavities sourced by an isotropic CaB. Analyzing various cavity geometries, we find that stacked, wide-base cavity arrays offer coherent enhancement of the axion signal. We apply our formalism to prospective upgrades of the ADMX experiment, including configurations with four and eighteen coupled cavities. Although these arrays do not achieve a coherent enhancement, optimizing the geometry could potentially yield an $\mathcal{O}(1)$ improvement in the sensitivity to the CaB.

Axions and ALPs↗

An analytical model for vertical dual-cavity quantum-dot optical amplifiers

Novel closed-form model for the threshold conditions and the optical gains of vertical dual-cavity semiconductor optical amplifier (VDC-SOA) is derived. Expressions for the transfer functions that relate the average photon density inside the two cavities to the incident photon density are derived. The model is simple, accurate and easy to use for designing dual-wavelength laser amplifiers. Good agreement is obtained between the analytical model and numerical calculations. The transmitted and reflective bistability characteristics of quantum dot VDC-SOA have been investigated. The threshold condition of each mode is expressed in terms of the top-cavity and the bottom-cavity currents. The dual modes λ{sub o}{sup +} and λ{sub o}{sup −} show different bistability behavior as a function of the top cavity current when the device operates at fixed operating point below the threshold curve. We find that the contrast ratio of mode λ{sub o}{sup +} is a weak function of the device currents, and the hysteresis width increases when the top cavity current is increased. For mode λ{sub o}{sup −} large contrast ratio and hysteresis width are obtained when the two cavities exhibit equal currents. Our analysis also reveals that the spectral characteristics of mode λ{sub o}{sup +} are different from that of mode λ{sub o}{sup −}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical properties of niobium radio-frequency cavities

Radio-frequency cavities made of bulk niobium are one of the components used in modern particle accelerators. The mechanical stability is an important aspect of cavity design, which typically relies on finite-element analysis simulations using material properties from tensile tests on sample. This contribution presents the results of strain and resonant frequency measurements as a function of a uniform pressure up to 722 kPa, applied to single-cell niobium cavities with different crystallographic structure, purity and treatments. In addition, burst tests of high-purity multi-cell cavities with different crystallographic structure have been conducted up to the tensile strength of the material. Finite-element analysis of the single-cell cavity geometry is in good agreement with the observed behavior in the elastic regime assuming a Young's modulus value of 88.5 GPa and a Poisson's ratio of 0.4, regardless of crystallographic structure, purity or treatment. However, the measured yield strength and tensile strength depend on crystallographic structure, material purity and treatment. In particular, the results from this study show that the mechanical properties of niobium cavities with large crystals are comparable to those of cavities made of fine-grain niobium.

36 MATERIALS SCIENCE↗

Beam dynamics in independent phased cavities

Linear accelerators containing the sequence of independently phased cavities with constant geometrical velocity along each structure are widely used in practice. The chain of cavities with identical cell lengths is utilized within a certain beam velocity range, with subsequent transformation to the next chain with higher cavity velocity. Design and analysis of beam dynamics in this type of accelerator are usually performed using numerical simulations. A full theoretical description of particle acceleration in an array of independent phased cavities has not been developed. In the present paper, we provide an analytical treatment of beam dynamics in such linacs employing Hamiltonian formalism. We begin our analysis with an examination of beam dynamics in an equivalent traveling wave of a single cavity, propagating within accelerating section with constant phase velocity. We then consider beam dynamics in arrays of cavities, utilizing an effective traveling wave propagating along with the whole accelerator with the velocity of synchronous (reference) particle. The analysis concluded with the determination of the matched beam conditions. Finally, we present a beam dynamics study in 805 MHz Coupled Cavity Linac of the LANSCE accelerator facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

QM and QM/MM Studies of Uranyl Fluorides in the Gas and Aqueous Phases and in the Hydrophobic Cavities of Tetrabrachion

The structural properties and electronic structures of pentacoordinated uranyl complexes belonging to the [UO₂Fn(H₂O) 5-n ] 2-n series have been studied in the gas and aqueous phases using density functionals with relativistic pseudopotentials and all-electron basis sets in the gas-phase calculations in combination with COSMO in the aqueous phase. In addition, the conformational orientation and structural and electronic properties of [UO₂F₅]³¯ in the hydrophobic cavities of the right-handed coiled-coil (RHCC) protein of tetrabrachion have been determined using the hybrid QM/MM method. Although there is good agreement between the available experimental geometrical parameters and the values obtained in the aqueous phase using pseudopotentials or all-electron basis sets, variation of the uranyl U=O bond with the number of fluoride ligands is only truly captured after the inclusion of five water molecules in the second coordination sphere around the molecules. The docking procedure used in this work shows that there are only two possible orientations of the uranyl group of [UO₂F₅]³¯ embedded in the hydrophobic cavities of the RHCC protein. The two orientations are exclusively along the axes perpendicular to the protein axial channel with no possible orientation of the uranyl group along the axial channel because of both steric effects and interaction with the alkyl chain of the isoleucine residues pointing into the axial channel. In addition, the embedded complex is always positioned nearer to the isoleucine residues at the N-terminal ends of the hydrophobic cavities. Energy analysis, however, reveals that both conformations can only be observed in cavity 2, the largest hydrophobic cavity. The structural and electronic properties of the ligand embedded in this cavity are very similar to those of the gas-phase structure. A comparable study of [Pt(CN)₆]²¯ and the anticancer drug cisplatin, [PtCl₂(NH₃)₂], in cavity 2, revealed the existence of just two orientations for the former, similar to the uranyl complex, and multiple orientations for the latter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strong parametric dispersive shifts in a statically decoupled two-qubit cavity QED system

Qubits in cavity quantum electrodynamic (QED) architectures are often operated in the dispersive regime, in which the operating frequency of the cavity depends on the energy state of the qubit, and vice versa. The ability to tune these dispersive shifts provides additional options for performing either quantum measurements or logical manipulations. Here we couple two transmon qubits to a lumped-element cavity through a shared superconducting quantum interference device (SQUID). In this work, our design balances the mutual capacitive and inductive circuit components so that both qubits are statically decoupled from the cavity with low flux sensitivity, offering protection from decoherence processes. Parametric driving of the SQUID flux enables independent, dynamical tuning of each qubit’s interaction with the cavity. As a practical demonstration, we perform pulsed parametric dispersive readout of both qubits. The dispersive frequency shifts of the cavity mode follow the theoretically expected magnitude and sign. This parametric approach creates an extensible, tunable cavity QED framework with various future applications, such as entanglement and error correction via multi-qubit parity readout, state and entanglement stabilization, and parametric logical gates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cavity morphology in a Ni based superalloy under heavy ion irradiation with hot pre-injected helium. II

In the current investigation, TEM in-situ heavy ion (1 MeV Kr{sup 2+}) irradiation with helium pre-injected at elevated temperature (400 °C) was conducted to simulate in-reactor neutron irradiation induced damage in CANDU spacer material Inconel X-750, in an effort to understand the effects of helium on irradiation induced cavity microstructures. Three different quantities of helium, 400 appm, 1000 appm, and 5000 appm, were pre-injected directly into TEM foils at 400 °C. The samples containing helium were then irradiated in-situ with 1 MeV Kr{sup 2+} at 400 °C to a final dose of 5.4 dpa (displacement per atom). Cavities were formed from the helium injection solely and the cavity density and size increased with increasing helium dosage. In contrast to previous heavy ion irradiations with cold pre-injected helium, heterogeneous nucleation of cavities was observed. During the ensuing heavy ion irradiation, dynamical observation showed noticeable size increase in cavities which nucleated close to the grain boundaries. A “bubble-void” transformation was observed after Kr{sup 2+} irradiation to high dose (5.4 dpa) in samples containing 1000 appm and 5000 appm helium. Cavity distribution was found to be consistent with in-reactor neutron irradiation induced cavity microstructures. This implies that the distribution of helium is greatly dependent on the injection temperature, and helium pre-injection at high temperature is preferred for simulating the migration of the transmutation produced helium.

36 MATERIALS SCIENCE↗

THE STRUCTURE OF PRE-TRANSITIONAL PROTOPLANETARY DISKS. I. RADIATIVE TRANSFER MODELING OF THE DISK+CAVITY IN THE PDS 70 SYSTEM

Through detailed radiative transfer modeling, we present a disk+cavity model to simultaneously explain both the spectral energy distribution (SED) and Subaru H-band polarized light imaging for the pre-transitional protoplanetary disk PDS 70. In particular, we are able to match not only the radial dependence but also the absolute scale of the surface brightness of the scattered light. Our disk model has a cavity 65 AU in radius, which is heavily depleted of sub-micron-sized dust grains, and a small residual inner disk that produces a weak but still optically thick near-IR excess in the SED. To explain the contrast of the cavity's edge in the Subaru image, a factor of {approx}1000 depletion for the sub-micron-sized dust inside the cavity is required. The total dust mass of the disk may be on the order of 10{sup -4} M {sub Sun }, only weakly constrained due to the lack of long-wavelength observations and the uncertainties in the dust model. The scale height of the sub-micron-sized dust is {approx}6 AU at the cavity edge, and the cavity wall is optically thick in the vertical direction at H-band. PDS 70 is not a member of the class of (pre-)transitional disks identified by Dong et al., whose members only show evidence of the cavity in the millimeter-size dust but not the sub-micron-sized dust in resolved images. The two classes of (pre-)transitional disks may form through different mechanisms, or they may simply be at different evolution stages in the disk-clearing process.

79 ASTRONOMY AND ASTROPHYSICS↗

Advances in Nb 3 Sn superconducting radiofrequency cavities towards first practical accelerator applications

Abstract Nb 3 Sn is a promising next-generation material for superconducting radiofrequency cavities, with significant potential for both large scale and compact accelerator applications. However, so far, Nb 3 Sn cavities have been limited to continuous wave accelerating fields <18 MV m −1 . In this paper, new results are presented with significantly higher fields, as high as 24 MV m −1 in single cell cavities. Results are also presented from the first ever Nb 3 Sn-coated 1.3 GHz 9-cell cavity, a full-scale demonstration on the cavity type used in production for the European XFEL and LCLS-II. Results are presented together with heat dissipation curves to emphasize the potential for industrial accelerator applications using cryocooler-based cooling systems. The cavities studied have an atypical shiny visual appearance, and microscopy studies of witness samples reveal significantly reduced surface roughness and smaller film thickness compared to typical Nb 3 Sn films for superconducting cavities. Possible mechanisms for increased maximum field are discussed as well as implications for physics of RF superconductivity in the low coherence length regime. Outlook for continued development is presented.

43 PARTICLE ACCELERATORS↗

Enhanced tunable cavity development for axion dark matter searches using a piezoelectric motor in combination with gears

Most search experiments sensitive to quantum chromodynamics (QCD) axion dark matter benefit from microwave cavities, as electromagnetic resonators, that enhance the detectable axion signal power and thus the experimental sensitivity drastically. As the possible axion mass spans multiple orders of magnitude, microwave cavities must be tunable and it is desirable for the cavity to have a tunable frequency range that is as wide as possible. Since the tunable frequency range generally increases as the dimension of the conductor tuning rod increases for a given cylindrical conductor cavity system, we developed a cavity system with a large dimensional tuning rod in order to increase this. Here we, for the first time, employed not only a piezoelectric motor, but also gears to drive a large and accordingly heavy tuning rod, where such a combination to increase driving power can be adopted for extreme environments as is the case for axion dark matter experiments: cryogenic, high-magnetic-field, and high vacuum. Thanks to such higher power derived from the piezoelectric motor and gear combination, we realized a wideband tunable cavity whose frequency range is about 42% of the central resonant frequency of the cavity, without sacrificing the experimental sensitivity too much.

47 OTHER INSTRUMENTATION↗

Development of a cryocooler conduction-cooled 650 MHz SRF cavity operating at ~10 MV/m cw accelerating gradient

SRF cavities for particle acceleration are conventionally operated immersed in a bath of liquid helium at 4.2 K and below. Although this cooling configuration is practically and economically viable for large scientific accelerator installations, it may not be so for smaller accelerators intended for industrial applications such as the treatment of wastewater, sludge, flue gases, etc. In this paper, we describe a procedure to operate SRF cavities without liquid helium that can be used to construct electron-beam sources for industrial applications of electron irradiation (1-10 MeV electron energy). In this procedure, an elliptical single-cell 650 MHz niobium-tin coated niobium cavity is coupled to a closed-cycle 4.2 K cryocooler using high purity aluminum thermal links. The cryocooler conductively extracts heat (RF dissipation) from the cavity without requiring liquid helium around the cavity. We present construction details of this cryocooler conduction-cooling technique and systematic experiments that have demonstrated ~10 MV/m cw gradient on the cavity. By straightforward scaling up the cavity length and number of cryocoolers, the technique will provide the complete range of 1-10 MeV electron energy for industrial applications.

43 PARTICLE ACCELERATORS↗

Optically accessible high-finesse millimeter-wave resonator for cavity quantum electrodynamics with atom arrays

Cavity quantum electrodynamics (QED) is a powerful tool in quantum science, enabling preparation of nonclassical states of light and scalable entanglement of many atoms coupled to a single field mode. While the most coherent atom-photon interactions have been achieved using superconducting millimeter-wave cavities coupled to Rydberg atoms, these platforms so far lack the optical access required for trapping and addressing individual atomic qubits. We present a millimeter-wave Fabry-Pérot cavity with finesse 5.8⁢(1) ×10 7 at a temperature of 1 K providing generous transverse optical access (numerical aperture 0.56). Conflicting goals of strong atom-photon coupling and optical access motivate a near-confocal geometry. Close to confocality, however, postparaxial corrections to the cavity spectrum introduce unexpected degeneracies between transverse modes, leading to excess cavity loss. Modeling these corrections allows for tuning the cavity geometry to evade this loss, producing a high finesse that will enable cavity QED experiments with trapped atoms deep in the strong coupling regime.

Zhang, Tony [Stanford Univ., CA (United States); S↗

Fast Sideband Control of a Multimode Cavity Memory with Weak Dispersive Coupling to a Transmon

Mitigating ancilla-mediated error channels is a critical challenge in controlling high-quality superconducting cavities using circuit quantum electrodynamics (cQED). We address this by weakening the dispersive coupling while demonstrating fast, high-fidelity multimode control through transmon-mediated sideband interactions. We implement transmon-cavity SWAP gates with speeds up to 30 times larger than the bare dispersive coupling. Combined with transmon rotations, this enables universal state preparation in a single mode, though achieving unitary gates and extending control to multiple modes remains a challenge. In this work, we overcome this limitation by introducing two control strategies: (i) a shelving technique that stores populations in sideband-transparent states, and (ii) a method that exploits the dispersive shift to implement photon-number-selective transmon-cavity SWAP gates. We use these protocols to prepare Fock and binomial code states across any of the ten modes of a multimode cavity with millisecond coherence times—serving as a multimode quantum memory. We demonstrate unitaries that encode and decode an arbitrary qubit state from the transmon into corresponding vacuum and Fock state superpositions, as well as entangled NOON states of cavity mode pairs—a scheme extendable to arbitrary multimode Fock encodings in the cavity modes. Furthermore, we implement a new binomial encoding gate that converts arbitrary transmon superpositions into binomial code states in any cavity mode at a rate exceeding the dispersive shifts in our system, achieving an average post-selected state fidelity of 96.3% in a 4 μ⁢s gate time. By using precalibrated transmon and sideband pulses, our work demonstrates multimode control with significantly reduced calibration overhead, enabling efficient unitary operations using sideband interactions in multimode cQED systems.

Huang, Jordan [Rutgers Univ., Piscataway, NJ (Unit↗

Hybrid Physical Chemical Vapor Deposition of Magnesium Diboride Inside 3.9 GHz Mock Cavities

Magnesium diboride (MgB 2 ) is considered a candidate for the next generation superconducting radio frequency (SRF) cavities due to its higher critical temperature T c (40 K) and increased superheating field (H sh ) compared to other conventional superconductors. These properties can lead to reduced BCS surface resistance (R BCS S ) and residual resistance (R res ), according to theoretical studies, and enhanced accelerating field (E acc ) values. Here, we investigated the possibility of coating the inner surface of a 3.9 GHz SRF cavity with MgB 2 by using a hybrid physical-vapor deposition (HPCVD) system designed for this purpose. To simulate the actual 3.9 GHz SRF cavity, we also employed a stainless steel mock cavity for the study. The film qualities were characterized on small substrates that were placed at the selected positions within the cavity. MgB 2 films on stainless steel foils, niobium pieces, and SiC substrates showed transition temperatures in the range of 30-38 K with a c-axis-oriented crystallinity observed for films grown on SiC substrates. Dielectric resonator measurements at 18 GHz resulted in a quality factor of over 30 000 for the MgB 2 film grown on a SiC substrate. Furthermore, by employing the HPCVD technique, a uniform film was achieved across the cavity interior, demonstrating the feasibility of HPCVD for MgB 2 coatings for SRF cavities.

36 MATERIALS SCIENCE↗

Operation and investigation of a tilted bottom cavity for pyrgeometer characterizations

A new cavity for pyrgeometer characterizations has been built at the Infrared Radiometry Section of the World Radiation Center (WRC-IRS) at PMOD/WRC. The calculated effective emissivity of 0.99993{+-}0.00033 was obtained from Monte Carlo simulations taking into account the geometry and the measured temperature distributions of the cavity. The cavity is operated in a temperature range of -30 deg. C to +30 deg. C and is initially flushed with nitrogen to reduce the relative humidity in the cavity. The estimated uncertainties of retrieved pyrgeometer parameters k1, k2, and k3 are {+-}0.024, {+-}0.0008, and {+-}0.03, respectively. The relative uncertainty of pyrgeometer sensitivity C is 0.8%. The comparison with the cavity used since 1995 at PMOD/WRC gave average differences of 0.005, 0.00026, and 0.08 for k1, k2, and k3, respectively. The pyrgeometer sensitivity retrieved with the new cavity is on average 1.0% higher than with the original cavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗