Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Blind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Evaluating a Commercial Dynamic Line Rating Software with the National PMU Dataset

To accelerate the development of data-driven applications for power systems, the Department of Energy (DOE) supported the collection and curation of a synchrophasor dataset spanning two years of observations from transmission utilities across the US. This National PMU Dataset (NPDS) was anonymized and distributed to awardees of a DOE research grant under nondisclosure agreements (NDAs) but has also been retained at PNNL to enable further research. Agreements with data contributors prevent the data from being shared outside the organization. However, establishing a blind research validation methodology is envisioned to maximize the value proposition of the NPDS. In this validation strategy, researchers may share algorithms/software (potentially as executables to protect intellectual property) with PNNL, and PNNL will share feedback about the software’s performance on subsets of the NPDS. Such a blind methodology ensures that sensitive information about critical infrastructure remains protected, but the value of the NPDS can be extended to research beyond PNNL. Through iterative feedback, the algorithms may be tweaked to address real-world artifacts. As the NPDS data is temporally and geographically diverse, it may capture features absent in smaller datasets used during the development of the algorithm under test. This report presents lessons learned from applying the blind validation methodology to LineID™, a synchrophasor-based dynamic line rating software developed by Topolonet Corporation. Improvements made to the software through iterative feedback, limitations of the validation methodology, as well as how the limitations of the NPDS affected the evaluation process are discussed. Observations indicate that the proposed validation methodology can be valuable for evaluating other tools in the future.

97 MATHEMATICS AND COMPUTING↗

Performance Demonstration Program Plan for Analysis of Simulated Headspace Gases

The Performance Demonstration Program (PDP) for headspace gases distributes blind audit samples in a gas matrix for analysis of volatile organic compounds (VOCs). Participating measurement facilities (i.e., fixed laboratories, mobile analysis systems, and on-line analytical systems) are located across the United States. Each sample distribution is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD) (DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardous Waste Facility Permit (NM4890139088-TSDF) issued by the New Mexico Environment Department (NMED). The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the Headspace Gas (HSG) PDP. Participating measurement facilities analyze blind audit samples of simulated TRU waste package headspace gases according to the criteria set by this PDP Plan. Blind audit samples (hereafter referred to as PDP samples) are used as an independent means to assess each measurement facility’s compliance with the WAP quality assurance objectives (QAOs). To the extent possible, the concentrations of VOC analytes in the PDP samples encompass the range of concentrations anticipated in actual TRU waste package headspace gas samples. Analyses of headspace gases are required by the WIPP to demonstrate compliance with regulatory requirements. These analyses must be performed by measurement facilities that have demonstrated acceptable performance in this PDP. These analyses are referred to as WIPP analyses and the TRU waste package headspace gas samples on which they are performed are referred to as WIPP samples in this document. Participating measurement facilities must analyze PDP samples using the same procedures used for routine waste characterization analyses of WIPP samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Demonstration Program Plan for Analysis of Simulated Headspace Gases

The Performance Demonstration Program (PDP) for headspace gases distributes blind audit samples in a gas matrix for analysis of volatile organic compounds (VOCs). Participating measurement facilities (i.e., fixed laboratories, mobile analysis systems, and on-line analytical systems) are located across the United States. Each sample distribution is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD) (DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardous Waste Facility Permit (NM4890139088-TSDF) issued by the New Mexico Environment Department (NMED). The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the Headspace Gas (HSG) PDP. Participating measurement facilities analyze blind audit samples of simulated TRU waste package headspace gases according to the criteria set by this PDP Plan. Blind audit samples (hereafter referred to as PDP samples) are used as an independent means to assess each measurement facility’s compliance with the WAP quality assurance objectives (QAOs). To the extent possible, the concentrations of VOC analytes in the PDP samples encompass the range of concentrations anticipated in actual TRU waste package headspace gas samples. Analyses of headspace gases are required by the WIPP to demonstrate compliance with regulatory requirements. These analyses must be performed by measurement facilities that have demonstrated acceptable performance in this PDP. These analyses are referred to as WIPP analyses and the TRU waste package headspace gas samples on which they are performed are referred to as WIPP samples in this document. Participating measurement facilities must analyze PDP samples using the same procedures used for routine waste characterization analyses of WIPP samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE ALMA SPECTROSCOPIC SURVEY IN THE HUBBLE ULTRA DEEP FIELD: IMPLICATIONS FOR SPECTRAL LINE INTENSITY MAPPING AT MILLIMETER WAVELENGTHS AND CMB SPECTRAL DISTORTIONS

We present direct estimates of the mean sky brightness temperature in observing bands around 99 and 242 GHz due to line emission from distant galaxies. These values are calculated from the summed line emission observed in a blind, deep survey for spectral line emission from high redshift galaxies using ALMA (the ALMA spectral deep field observations “ASPECS” survey). In the 99 GHz band, the mean brightness will be dominated by rotational transitions of CO from intermediate and high redshift galaxies. In the 242 GHz band, the emission could be a combination of higher order CO lines, and possibly [C ii] 158 μ m line emission from very high redshift galaxies ( z ∼ 6–7). The mean line surface brightness is a quantity that is relevant to measurements of spectral distortions of the cosmic microwave background, and as a potential tool for studying large-scale structures in the early universe using intensity mapping. While the cosmic volume and the number of detections are admittedly small, this pilot survey provides a direct measure of the mean line surface brightness, independent of conversion factors, excitation, or other galaxy formation model assumptions. The mean surface brightness in the 99 GHZ band is: T{sub B} = 0.94 ± 0.09 μ K. In the 242 GHz band, the mean brightness is: T{sub B} = 0.55 ± 0.033 μ K. These should be interpreted as lower limits on the average sky signal, since we only include lines detected individually in the blind survey, while in a low resolution intensity mapping experiment, there will also be the summed contribution from lower luminosity galaxies that cannot be detected individually in the current blind survey.

79 ASTRONOMY AND ASTROPHYSICS↗

The Magnificent Five Images of Supernova Refsdal: Time Delay and Magnification Measurements

In late 2014, four images of supernova (SN) "Refsdal," the first known example of a strongly lensed SN with multiple resolved images, were detected in the MACS J1149 galaxy-cluster field. Following the images' discovery, the SN was predicted to reappear within hundreds of days at a new position ~8'' away in the field. The observed reappearance in late 2015 makes it possible to carry out Refsdal's original proposal to use a multiply imaged SN to measure the Hubble constant H0, since the time delay between appearances should vary inversely with H0. Moreover, the position, brightness, and timing of the reappearance enable a novel test of the blind predictions of galaxy-cluster models, which are typically constrained only by the positions of multiply imaged galaxies. We have developed a new photometry pipeline that uses DOLPHOT to measure the fluxes of the five images of SN Refsdal from difference images. We apply four separate techniques to perform a blind measurement of the relative time delays and magnification ratios between the last image SX and the earlier images S1–S4. We measure the relative time delay of SX–S1 to be 376.0$^{+5.6}_{–5.5}$ days and the relative magnification to be 0.30$^{+0.5}_{–0.3}$. This corresponds to a 1.5% precision on the time delay and 17% precision for the magnification ratios and includes uncertainties due to millilensing and microlensing. In an accompanying paper, we place initial and blind constraints on the value of the Hubble constant.

79 ASTRONOMY AND ASTROPHYSICS↗

Color identification testing device

Testing device, which determines ability of a technician to identify color-coded electric wires, is superior to standard color blindness tests. It tests speed of wire selection, detects partial color blindness, allows rapid testing, and may be administered by a color blind person.

Brawner, E. L.↗

Imaging radar observations of Askja Caldera, Iceland

A 'blind' test involving interpretation of computer-enhanced like- and cross-polarized radar images is used to evaluate the surface roughness of Askja Caldera, a large volcanic complex in central Iceland. The 'blind' test differs from earlier analyses of radar observations in that computer-processes images and both qualitative and quantitative analyses are used. Attention is given to photogeologic examination and subsequent survey-type field observations, along with aerial photography during the field trip. The results indicate that the 'blind' test of radar interpretation of the Askja volcanic area can be considered suitable within the framework of limitations of radar data considered explicitly from the onset. The limitations of the radar techniques can be eliminated by using oblique-viewing conditions to remove geometric distortions and slope effects.

Malin, M. C.↗

Hydraulics and geology related to beach restoration in Lee County, Florida

The erosion problem on Captiva Island is discussed. It is due to a deficit in the sand budget of the littoral drift system; a system with losses due to attrition of the particles and mass losses into the lagoons, to offshore, and to lateral transport. The effect that reopening Blind Pass would have, and the placement of sediment retaining structures in the surf zone at the northern and southern limits of the Captiva beach system, wave examined. A geological approach was used to study the origin and dynamic changes that have occurred. Through hydraulic modeling, changes that will occur by reopening and stabilizing Blind Pass are predicted. It is concluded that if the island is to be stabilized, beach nourishment with proper amounts and particle size is a necessity and that jetties adequate to restrict lateral and offshore losses are essential. It is shown that the reopening of Blind Pass would have minimal effects on the passes to the north and south, and would improve the environmental conditions in the sound with no adverse effects on the beach system.

Winton, T.↗

Perception-action relationships reconsidered in light of spatial display instruments

Spatial display instruments convey information about both the identity and the location of objects in order to assist surgeons, astronauts, pilots, blind individuals, and others in identification, remote manipulations, navigation, and obstacle avoidance. Scientists believe that these instruments have not reached their full potential and that progress toward new applications, including the possibility of restoring sight to the blind, will be accelerated by advancing the understanding of perceptual processes. This stimulating challenge to basic researchers was advanced by Paul Bach-Y-Rita (1972) and by the National Academy of Science (1986) report on Electronic Aids for the Blind. Although progress has been made, new applications of spatial display instruments in medicine, space, aviation, and rehabilitation await improved theoretical and empirical foundations.

Shebilske, Wayne L.↗

Percolation of interaction diffusing particles

The connectivity properties of systems of diffusing interacting particles with the blind and myopic diffusion rules are studied. It is found that the blind rule case is equivalent to the lattice gas with J = 0 in all dimensions. The connectivity properties of blind rule diffusion are described by random site percolation due to the fact that the density on neighboring sites is uncorrelated.

Selinger, Robin Blumberg↗

Results of the NY-Alesund ozone measurements intercomparison NAOMI

Worldwide, about ten Differential Absorption Lidars are used for long-term monitoring of stratospheric ozone. These systems are an important component of the Network for the Detection of Stratospheric Change. Although DIALs are self-calibrating in principle, regular intercomparisons with other ozone-lidars, microwave radiometers or ozone-sondes are highly desirable to ensure high data quality at a well known level. The Network for the Detection of Stratospheric Change (NDSC) validation policy suggests that such intercomparisons be "blind", meaning all participants submit their data to an impartial referee, without seeing results from the other participants. Here we report on the "blind" intercomparison taking place from January 20th to February 10th 1998 at Ny-Alesund, Spitsbergen (78.92 deg N, 11.95 deg E). Participating groups were from the Alfred Wegener Institute, Potsdam, operating the NDSC DIAL system at Ny-Alesund, from the University of Bremen operating the NDSC microwave radiometer for ozone profiling at Ny-Alesund, and the NASA Goddard Space Flight Center group with the "NDSC travelling standard" STROZ-LITE. The first author acted as the impartial referee. Also used for the intercomparison were data from ECC-6A/Vaisala RS80 ozone sondes routinely launched at Ny-Alesund by the AWI group. A 1% KI solution (3 ml) and the 1986 ECC pump correction (1.092 at 5 hPa) are used. The ECC-data were available to all participants during the campaign and thus were not "blind". Table 1 summarizes the expected performance of the instruments participating in the ozone intercomparison reported in this paper.

Steinbrecht, W.↗

Ambient Light Intensity, Actigraphy, Sleep and Respiration, Circadian Temperature and Melatonin Rhythms and Daytime Performance of Crew Members During Space Flight on STS-90 and STS-95 Missions

Sleep disruption and associated waking sleepiness and fatigue are common during space flight. A survey of 58 crew members from nine space shuttle missions revealed that most suffered from sleep disruption, and reportedly slept an average of only 6.1 hours per day of flight as compared to an average of 7.9 hours per day on the ground. Nineteen percent of crewmembers on single shift missions and 50 percent of the crewmembers in dual shift operations reported sleeping pill usage (benzodiazepines) during their missions. Benzodiazepines are effective as hypnotics, however, not without adverse side effects including carryover sedation and performance impairment, anterograde amnesia, and alterations in sleep EEG. Our preliminary ground-based data suggest that pre-sleep administration of 0.3 mg of the pineal hormone melatonin may have the acute hypnotic properties needed for treating the sleep disruption of space flight without producing the adverse side effects associated with benzodiazepines. We hypothesize that pre-sleep administration of melatonin will result in decreased sleep latency, reduced nocturnal sleep disruption, improved sleep efficiency, and enhanced next-day alertness and cognitive performance both in ground-based simulations and during the space shuttle missions. Specifically, we have carried out experiments in which: (1) ambient light intensity aboard the space shuttle is assessed during flight; (2) the impact of space flight on sleep (assessed polysomnographically and actigraphically), respiration during sleep, circadian temperature and melatonin rhythms, waking neurobehavioral alertness and performance is assessed in crew members of the Neurolab and STS-95 missions; (3) the effectiveness of melatonin as a hypnotic is assessed independently of its effects on the phase of the endogenous circadian pacemaker in ground-based studies, using a powerful experimental model of the dyssomnia of space flight; (4) the effectiveness of melatonin as a hypnotic is assessed during the STS-90 (Neurolab) and STS-95 missions in a double-blind placebo-controlled trial. In both flight-based experiments, the effects of melatonin on sleep stages and spectral composition of the EEG during sleep will be determined as well as its effects on daytime alertness and performance; (5) the impact of space flight on sleep and waking neurobehavioral alertness and performance in 30-45-year-old astronauts is compared with its impact in a 77-year-old astronaut. This case study is the first to assess the effects of space flight on an older individual. Because the investigators are still blind to the treatment in this double-blind, placebo-controlled trial, preliminary results will be presented independent of the drug condition.

Czeisler, Charles A.↗

Microwave and Millimeter Wave Nondestructive Evaluation of the Space Shuttle External Tank Insulating Foam

The Space Shuttle Columbia s catastrophic failure has been attributed to a piece of external fuel tank insulating SOFI (Spray On Foam Insulation) foam striking the leading edge of the left wing of the orbiter causing significant damage to some of the protecting heat tiles. The accident emphasizes the growing need to develop effective, robust and life-cycle oriented methods of nondestructive testing and evaluation (NDT&E) of complex conductor-backed insulating foam and protective acreage heat tiles used in the space shuttle fleet and in future multi-launch space vehicles. The insulating SOFI foam is constructed from closed-cell foam. In the microwave regime this foam is in the family of low permittivity and low loss dielectric materials. Near-field microwave and millimeter wave NDT methods were one of the techniques chosen for this purpose. To this end several flat and thick SOFI foam panels, two structurally complex panels similar to the external fuel tank and a "blind" panel were used in this investigation. Several anomalies such as voids and disbonds were embedded in these panels at various locations. The location and properties of the embedded anomalies in the "blind" panel were not disclosed to the investigating team prior to the investigation. Three frequency bands were used in this investigation covering a frequency range of 8-75 GHz. Moreover, the influence of signal polarization was also investigated. Overall the results of this investigation were very promising for detecting the presence of anomalies in different panels covered with relatively thick insulating SOFI foam. Different types of anomalies were detected in foam up to 9 in thick. Many of the anomalies in the more complex panels were also detected. When investigating the blind panel no false positives were detected. Anomalies in between and underneath bolt heads were not easily detected. This paper presents the results of this investigation along with a discussion of the capabilities of the method used.

Shrestha, S.↗

Combining Ratio Estimation for Low Density Parity Check (LDPC) Coding

The Low Density Parity Check (LDPC) Code decoding algorithm make use of a scaled receive signal derived from maximizing the log-likelihood ratio of the received signal. The scaling factor (often called the combining ratio) in an AWGN channel is a ratio between signal amplitude and noise variance. Accurately estimating this ratio has shown as much as 0.6 dB decoding performance gain. This presentation briefly describes three methods for estimating the combining ratio: a Pilot-Guided estimation method, a Blind estimation method, and a Simulation-Based Look-Up table. The Pilot Guided Estimation method has shown that the maximum likelihood estimates of signal amplitude is the mean inner product of the received sequence and the known sequence, the attached synchronization marker (ASM) , and signal variance is the difference of the mean of the squared received sequence and the square of the signal amplitude. This method has the advantage of simplicity at the expense of latency since several frames worth of ASMs. The Blind estimation method s maximum likelihood estimator is the average of the product of the received signal with the hyperbolic tangent of the product combining ratio and the received signal. The root of this equation can be determined by an iterative binary search between 0 and 1 after normalizing the received sequence. This method has the benefit of requiring one frame of data to estimate the combining ratio which is good for faster changing channels compared to the previous method, however it is computationally expensive. The final method uses a look-up table based on prior simulated results to determine signal amplitude and noise variance. In this method the received mean signal strength is controlled to a constant soft decision value. The magnitude of the deviation is averaged over a predetermined number of samples. This value is referenced in a look up table to determine the combining ratio that prior simulation associated with the average magnitude of the deviation. This method is more complicated than the Pilot-Guided Method due to the gain control circuitry, but does not have the real-time computation complexity of the Blind Estimation method. Each of these methods can be used to provide an accurate estimation of the combining ratio, and the final selection of the estimation method depends on other design constraints.

Mahmoud, Saad↗

Deja Vu All Over Again: The Reappearance of Supernova Refsdal

In Hubble Space Telescope (HST) imaging taken on 2014 November 10, four images of supernova (SN) Refsdal(redshift z1.49) appeared in an Einstein-cross-like configuration (images S1S4) around an early-type galaxy in the cluster MACS J1149.5+2223 (z0.54). Almost all lens models of the cluster have predicted that the SN should reappear within a year in a second host-galaxy image created by the clusters potential. In HST observations taken on 2015 December 11, we find a new source at the predicted position of the new image of SN Refsdal approximately 8 from the previous images S1S4. This marks the first time the appearance of a SN at a particular time and location in the sky was successfully predicted in advance! We use these data and the light curve from the first four observed images of SN Refsdal to place constraints on the relative time delay and magnification of the new image (SX) compared to images S1S4. This enables us, for the first time, to test blind lens model predictions of both magnifications and time delays for a lensed SN. We find that the timing and brightness of the new image are consistent with the blind predictions of a fraction of the models. The reappearance illustrates the discriminatory power of this blind test and its utility to uncover sources of systematic uncertainty. From planned HST photometry, we expect to reach a precision of 12 on the time delay between S1S4 and SX.

galaxies: clusters: general – galaxies: individu↗

Mapping by VESGEN of Blood Vessels in the Retinas of Astronauts Pre- and Post-Flight to the ISS

Research by NASA [1] established that significant risks for visual and ocular impairments associated with increased intracranial pressure (VIIP) are incurred by microgravity spaceflight, especially long-duration missions. It is well established in physiology and pathology that a fundamental role of the microvasculature is to mediate fluid transfers and remodel actively in response to environmental, immune and other stresses. We therefore hypothesize that remodeling of retinal blood vessels necessarily occurs during accommodation of microgravity-induced fluid shifts prior to subsequent development of visual and ocular impairments. Potential contributions of retinal vascular remodeling to VIIP etiology are therefore being investigated by NASA's innovative VESsel GENeration Analysis (VESGEN) software for two studies: (1) U.S. crew members before and after ISS missions, and (2) head-down tilt in human subjects before and after 70 days of bed rest. We anticipate that results of the two studies will be complete by the Investigators Workshop (January 22, 2017). METHODS: For the 2013 NASA NRA award, we are concluding the analysis of 30 degree infrared (IR) Heidelberg Spectralis images of retinal blood vessels by VESGEN (patents pending), a mature, automated software developed as a translational and basic vascular research discovery tool, particularly for retinal vascular disease. Subjects of our retrospective study include eight ISS crew members monitored for routine occupational surveillance pre- and post-flight, who provided their study consents to NASAs Lifetime Surveillance of Astronaut Health (LSAH) in coordination with approval of the VESGEN retrospective study protocol by NASAs Institutional Review Board (IRB). The ophthalmic retinal images (average image resolution, approximately 5.6 microns per pixel) are blinded as to pre and post ISS status until the second portion of our study, when VESGEN results will be correlated with other ophthalmic and medical findings for the crew members. Due to image resolution challenges, a novel Matlab tool was developed for aligning pre and post images, and comparing (querying) the two images for differences in the morphology of small vessels. RESULTS: During the past year, LSAH approved the release of all astronaut retinal images to our study for VESGEN analysis. Substantial progress on the initial blinded portion of the study is in place. We anticipate that VESGEN analysis of the 32 Spectralis IR retinal images will be complete for presentation at the 2017 IWS meeting. CONCLUSIONS: Modified retinal vascular patterning may offer early-stage predictions of ocular changes resulting in decreased visual acuity for the VIIP syndrome. Novel insights provided by VESGEN into progressively pathological and blinding vascular remodeling in the human retina currently help to guide other NIH- and NASA-supported therapeutic studies of retinal disease and modeling of the VIIP risk. Results of our vascular investigation of the retinas of astronauts pre- and post-flight may help advance the understanding of both healthy and pathological adaptations to fluid shifts in microgravity associated with the VIIP syndrome. Preliminary results indicate that imaging of higher resolution, such as the new OCT angiography (OCT-A) technology, will be required to determine conclusively the role of the smaller retinal and choroidal vessels in VIIP etiology.

VESGEN↗

Finding (Or Not) New Gamma-Ray Pulsars with GLAST

Young energetic pulsars will likely be the largest class of Galactic sources observed by GLAST, with many hundreds detected. Many will be unknown as radio pulsars, making pulsation detection dependent on radio and/or x-ray observations or on blind periodicity searches of the gamma-rays. Estimates for the number of pulsars GLAST will detect in blind searches have ranged from tens to many hundreds. I argue that the number will be near the low end of this range, partly due to observations being made in a scanning as opposed to a pointing mode. This paper briefly reviews how blind pulsar searches will be conducted using GLAST, what limits these searches, and how the computations and statistics scale with various parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Primary Water Stress Corrosion Cracks in Nickel Alloy Dissimilar Metal Welds: Detection and Sizing Using Established and Emerging Nondestructive Examination Techniques

The U.S. Nuclear Regulatory Commission has established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) as a follow-on to the international cooperative Program for the Inspection of Nickel Alloy Components (PINC). The goal of PINC was to evaluate the capabilities of various nondestructive evaluation (NDE) techniques to detect and characterize surface-breaking primary water stress corrosion cracks in dissimilar-metal welds (DMW) in bottom-mounted instrumentation (BMI) penetrations and small-bore (≈400-mm diameter) piping components. A series of international blind round-robin tests were conducted by commercial and university inspection teams. Results from these tests showed that a combination of conventional and phased-array ultrasound techniques provided the highest performance for flaw detection and depth sizing in dissimilar metal piping welds. The effective detection of flaws in BMIs by eddy current and ultrasound shows that it may be possible to reliably inspect these components in the field. The goal of PARENT is to continue the work begun in PINC and apply the lessons learned to a series of open and blind international round-robin tests that will be conducted on a new set of piping components including large-bore (≈900-mm diameter) DMWs, small-bore DMWs, and BMIs. Open round-robin testing will engage universities and industry worldwide to investigate the reliability of emerging NDE techniques to detect and accurately size flaws having a wide range of lengths, depths, orientations, and locations. Blind round-robin testing will invite testing organizations worldwide, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from easy to very difficult to detect and size. This paper presents highlights of PINC and reports on the plans and progress for PARENT round-robin tests.

cracks↗