Global kinetic ballooning mode simulations in BOUT++

We report on simulation results of a 3+1 gyro-Landau-fluid (GLF) model in BOUT++ framework, which contributes to increasing the physics understanding of the edge turbulence. We find that there is no second stability region of kinetic ballooning modes (KBM) in the concentric circular geometry. The first unstable β of KBM decreases below the ideal ballooning mode threshold with increasing ${{\eta}_{i}}$. In order to study the KBM in the real tokamak equilibrium, we find that the approximation of shifted circular geometry ($\beta \ll {{\varepsilon}^{2}}$ ) is not valid for a high β global equilibrium near the second stability region of KBM. Thus we generate a series of real equilibria from a global equilibrium solver CORSICA, including both Shafranov shift and elongation effects, but not including bootstrap current. In these real equilibria, the second stability region of KBM are observed in our global linear simulations. The most unstable mode for different β are the same while the mode number spectrum near the second stability region is wider than the case near the first stability region. Here, the nonlinear simulations show that the energy loss of an ELM keeps increasing with β, because the linear drive of the turbulence remains strong for the case near the second stability region during profile evolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ELM-free H-mode phase and decoupling of peeling–ballooning stability boundary in the MAST Upgrade tokamak

A linear magnetohydrodynamic (MHD) peeling–ballooning stability analysis of the edge-localized mode (ELM)-free phase of a MAST Upgrade (MAST-U) H-mode plasma is presented. In contrast to other similar discharges, #47018 is found to have a significantly higher and wider pedestal during its ELM-free H-mode phase that lasts for approximately 80 ms; this is made possible by the reduced core MHD mode activity on the q = 2 surface. During this period, there is sustained decoupling of peeling and ballooning branches of the stability boundary on J–α space, opening an access channel to the second stability regime with higher peaks in pedestal current density $J_{\mathrm{N,ped}}$ and pressure gradient (α). Such decoupling of the stability boundary has not previously been observed in MAST-U H-modes, and if such a condition can be readily reproduced, it opens a wide range of opportunities for MAST-U to explore low-collisionality peeling-limited pedestal regimes as well as advanced scenarios such as quiescent H-modes that are relevant to future reactors such as STEP and ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Finite magnetic well effects on resistive and drift-resistive ballooning modes in a shaped tokamak

The impact of plasma shaping through magnetic well modifications on the stability of resistive ballooning modes (RBMs) in tokamaks is analysed, also including finite diamagnetic flows. Furthermore, various limiting cases of the dispersion relation, obtained by matching the ballooning equation across the ideal and resistive layers, are analysed. It is found that stability is generally improved by the combination of vertical elongation and positive triangularity, although, in some cases, the growth rate of the unstable mode can be enhanced by these effects. Usually, vertically elongated plasmas with no triangularity are prone to exhibit worse stability properties. A value for the critical β above which RBMs are driven unstable is identified, and a connection with type-III ELM activity is established.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetic-ballooning-limited pedestals in spherical tokamak plasmas

Abstract A theoretical model is presented that for the first time matches experimental measurements of the pedestal width-height Diallo scaling in the low-aspect-ratio high- β tokamak NSTX. Combining linear gyrokinetics with self-consistent pedestal equilibrium variation, kinetic-ballooning, rather than ideal-ballooning plasma instability, is shown to limit achievable confinement in spherical tokamak pedestals. Simulations are used to find the novel Gyrokinetic Critical Pedestal constraint, which determines the steepest pressure profile a pedestal can sustain subject to gyrokinetic instability. Gyrokinetic width-height scaling expressions for NSTX pedestals with varying density and temperature profiles are obtained. These scalings for STs depart significantly from that of conventional aspect ratio tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HX-POL - A Balloon-Bourne Hard X-Ray Polarimeter

We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays from cosmic sources through the dependence of the angular distribution of Compton scattered photons on the polarization direction. On a one-day balloon flight, HX-POL would allow us to measure the polarization of bright Crab-like sources for polarization degrees well below 10%. On a longer (15-30 day) flight from Australia or Antarctica, HX-POL would be be able to measure the polarization of bright galactic X-ray sources down to polarization degrees of a few percent. Hard X-ray polarization measurements provide unique venues for the study of particle acceleration processes by compact objects and relativistic outflows. In this paper, we discuss the overall instrument design and performance. Furthermore, we present results from laboratory tests of the Si and CZT detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of dose discrepancies due to inhomogeneities and radiographic contrast in balloon catheter brachytherapy

Recently, a device called MammoSite, consisting of a balloon and a catheter, was developed to perform partial-breast irradiation using a high-dose-rate (HDR) brachytherapy unit with ease and reproducibility. However, the actual dose to the skin does not agree well with the calculated dose by the treatment planning system because of the difference between the calculation condition and the real treatment condition (i.e., homogeneous water and full scatter condition vs contrast solution and lack of full scatter condition). In this study, the authors experimentally estimated dose discrepancies due to contrast and lack of full scatter in breast HDR brachytherapy with MammoSite. Using metal-oxide-semiconductor field-effect transistor detectors and a breast phantom, the dose discrepancies between the calculation and the treatment conditions were measured according to contrast concentration (10% and 20% volume ratios), balloon size (35 and 60 cm{sup 3}), and source to detector distance ranging from 25 to 50 mm. The source was an Ir-192 isotope from Nucletron HDR unit. The dose discrepancies from the calculation condition due to both contrast and lack of full scatter combined ranged from about -1.4{+-}2.5% to -18.2{+-}2.0% in the studied cases (error bound is in two sided confidence interval of 80% based on Student's t distribution). In all cases, the effect of lack of full scatter was dominant to that of contrast and significant dose discrepancies existed between the calculation and the real treatment conditions, indicating that the actual skin dose is less than that which is currently calculated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tethered Balloon Systems

Among ARM’s aerial platforms are tethered balloon systems (TBS), which consist of a helium-filled balloon, tether, winch, and sensors. TBS provide a safe way to collect data inside clouds, including mixed-phase clouds, where icing is a concern for airborne platforms. These systems are also flown above and below clouds to gather data related to wind, turbulence, thermodynamic state, aerosols, and the cloud-top environment.

54 ENVIRONMENTAL SCIENCES↗

A tethered-balloon PTRMS sampling approach for surverying of landscape-scale biogenic VOC fluxes

To survey landscape-scale fluxes of biogenic gases, a100-meterTeflon tube was attached to a tethered balloon as a sampling inlet for a fast response Proton Transfer Reaction Mass Spectrometer (PTRMS). Along with meteorological instruments deployed on the tethered balloon and at 3-mand outputs from a regional weather model, these observations were used to estimate landscape scale biogenic volatile organic compound fluxes with two micrometeorological techniques: mixed layer variance and surface layer gradients. This highly mobile sampling system was deployed at four field sites near Barcelona to estimate landscape-scale BVOC emission factors in a relatively short period (3 weeks). The two micrometeorological techniques agreed within the uncertainty of the flux measurements at all four sites even though the locations had considerable heterogeneity in species distribution and complex terrain. The observed fluxes were significantly different than emissions predicted with an emission model using site-specific emission factors and land-cover characteristics. Considering the wide range in reported BVOC emission factors of VOCs for individual vegetation species (more than an order of magnitude), this flux estimation technique is useful for constraining BVOC emission factors used as model inputs.

Greenberg, Jim↗

Balloon measurements of cosmic ray protons and helium over half a solar cycle 1965-1969.

Evaluation of differential energy spectra for protons and helium covering the energy range from 100 to 260 MeV/nucleon obtained from balloon flights made each summer (1965 to 1969) at Churchill, Manitoba, with the aid of a Geiger-tube hodoscope operated in conjunction with two scintillation elements used to measure dE/dx and E. Supplementary data from balloon flights at Minneapolis, Minn., and Sioux Falls, S. Dak. and from calibration exposures to protons and electrons were used to define backgrounds and to verify the predicted detector response. The observed proton spectra are characterized over a wide range of energy (30 to 300 MeV) by a simple relationship between cosmic-ray intensity J and kinetic energy T: J = AT. The helium spectra also follow this law at solar maximum but rise less steeply near solar minimum. This characteristic behavior can be interpreted in terms of a simple model in which convection is balanced by adiabatic deceleration.-

Rygg, T. A.↗

Techniques in balloon X-ray astronomy.

Since the first balloon observation of the Crab Nebula balloon data have provided much information on the positions, spectra, time variability and pulsed nature of localized sources, and on the spectrum and isotropy of diffuse galactic and universal components. Measurements are limited to energies above about 20 keV by atmospheric attenuation at 2 to 3 g/sq cm depth and to below several hundred keV by detector sensitivity. Detectors usually consist of large-area Na I or Cs I scintillation counters with anticoincidence collimators for rejection of charged particles and scattered X-rays. Proportional counters are occasionally used at lower energies and solid-state detectors are used where extreme energy resolution is important. The instruments require a pointing capability on the order of 1.0 to 0.1 deg, depending on the collimator aperture. Digital data is either recorded on board or telemetered using a PCM technique.

Peterson, L. E.↗

Instrumentation for balloon and rocket experiments.

Description of a number of plasma, particle, and field detectors used on rocket investigations in and above the earth's atmosphere. Emphasis is on magnetospheric and solar-interplanetary studies. A balloon-borne X-ray telescope system with 20-min pointing accuracy is discussed. A PCM telemetry system used on both balloons and rockets to handle scientific data is described which includes a simple Doppler ranging system that gives location to 1.5 km. A system to reduce and analyze PCM data on the ground is discussed.

Anderson, K. A.↗

Balloon launched decelerator test program: Post-test test report

Balloon Launched Decelerator Test (BLDT) flights were conducted during the summer of 1972 over the White Sands Missile Range. The purpose of these tests was to qualify the Viking disk-gap band parachute system behind a full-scale simulator of the Viking Entry Vehicle over the maximum range of entry conditions anticipated in the Viking '75 soft landing on Mars. Test concerns centered on the ability of a minimum weight parachute system to operate without structural damage in the turbulent wake of the blunt-body entry vehicle (140 deg, 11.5 diameter cone). This is the first known instance of parachute operation at supersonic speeds in the wake of such a large blunt body. The flight tests utilized the largest successful balloon-payload weight combination known to get to high altitude (120kft) where rocket engines were employed to boost the test vehicle to supersonic speeds and dynamic pressures simulating the range of conditions on Mars.

Dickinson, D.↗

Results of the 1970 balloon flight solar cell standardization program

For the eighth consective year, high-altitude calibration of solar cells was accomplished with the aid of free-flight balloons. Flights were conducted to an altitude of 36,576 m which is above 99.5% of earth's atmosphere where all water vapor levels and significant ozone bands are absent. Solar cells calibrated in this manner are significant used as intensity references in solar simulators and in terrestrial sunlight. Discussed is the method employed for high altitude balloon flight solar cell calibration. Also presented are data collected on 52 standard solar cells on two flights conducted in 1970. Solar cells flown repeatedly on successive flights have shown correlation of better than + or - 1.0%.