Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM SHAPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

On the controllability of a long flexible beam in orbit

The equations of planar motion for a long, flexible free-free beam in orbit are developed and include the effects of gravity-gradient torques and control torques resulting from actuators assumed to be located at specific points along the beam. The control devices are used to control both the orientation as well as the shape of the beam. Application of two classes of theorems to the linearized form of these equations is used to establish necessary and sufficient conditions for controllability for different combinations of number/location of actuators with the number of modes contained in the mathematical model. It is seen that the number of actuators, if properly located, can be less than the number of modes in the system model. A numerical example illustrates the controlled response to an initial perturbation in both pitch angle as well as beam shape.

Bainum, P. M.↗

High-pressure generation using double stage micro-paired diamond anvils shaped by focused ion beam

Micron-sized diamond anvils with a 3 μm culet were successfully processed using a focused ion beam (FIB) system and the generation of high pressures was confirmed using the double stage diamond anvil cell technique. The difficulty of aligning two second-stage micro-anvils was solved via the paired micro-anvil method. Micro-manufacturing using a FIB system enables us to control anvil shape, process any materials, including nano-polycrystalline diamond and single crystal diamond, and assemble the sample exactly in a very small space between the second-stage anvils. This method is highly reproducible. High pressures over 300 GPa were achieved, and the pressure distribution around the micro-anvil culet was evaluated by using a well-focused synchrotron micro-X-ray beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photocathode Laser Shaping for High Transformer Ratio Collinear Wakefield Acceleration

Beam-driven wakefield acceleration is one of the most promising advanced accelerator concepts. With this approach, the main beam is accelerated by absorbing the energy from a drive beam, which has a lower kinetic energy, but a much higher current. For efficient acceleration, it is important to shape the drive beam axially, to increase the so-called transformer ratio: the energy gain by the main beam over the energy loss of the drive beam. In most cases, the drive beam shaping is done with the help of beam phase space manipulations, along with removing portions of the beam with a scraper. Such shaping is complicated by itself, causing charge loss and thermal heating, but can also lead to beam instabilities, due to the alteration of the beam phase space. How the problem is being addressed: In this project, Euclid Techlabs proposes to reduce the complexity of this process by shaping the laser beam incident on the photocathode instead of the electron beam itself. This approach yields an additional “tuning knob” for shaping the electron beam. The photocathode laser pulse can be modified to have the desired longitudinal profile, which will result in the desired profile of the electron beam after acceleration in the photoinjector. Laser shaping is, in fact, analogous to previous electron beam shaping approaches. A chirped beam is passed through a dispersive element (spatial light modulator), and masked to achieve the desired shape.

43 PARTICLE ACCELERATORS↗

Controlled-Shape, Ultrasonic-Angle-Beam Standard Reflector

New ultrasonic angle-beam standard reflector uses impression of letter "l" steel-die stamp. NDE techniques and standard reflector apply to use of pulse-echo-type ultrasonic equipment for inspection of wrought metals including forgings and forging stock; rolled billet, bar or plate; and extruded bar, tube, and shapes. "l" reference standard reflector affords advantages of easy insertion in inspected item using common hand-tools and greatly reduced implementation time through elimination of machining operations.

Berry, J., Robertf.↗

The 3-D vision system integrated dexterous hand

Most multifingered hands use a tendon mechanism to minimize the size and weight of the hand. Such tendon mechanisms suffer from the problems of striction and friction of the tendons resulting in a reduction of control accuracy. A design for a 3-D vision system integrated dexterous hand with motor control is described which overcomes these problems. The proposed hand is composed of three three-jointed grasping fingers with tactile sensors on their tips, a two-jointed eye finger with a cross-shaped laser beam emitting diode in its distal part. The two non-grasping fingers allow 3-D vision capability and can rotate around the hand to see and measure the sides of grasped objects and the task environment. An algorithm that determines the range and local orientation of the contact surface using a cross-shaped laser beam is introduced along with some potential applications. An efficient method for finger force calculation is presented which uses the measured contact surface normals of an object.

Luo, Ren C.↗

The design and optimization of two low frequency energy harvesters employing 3C-SiC/AlN/Mo composite layers

This paper presents the design and simulation of twocantilever-based energy harvesters that employs cubic silicon carbide on silicon (3C-SiC-on-Si) wafer as the base material and bottom electrode. Aluminum Nitride (AlN) is employed as the piezoelectric/middle layer due to its excellent material properties and high stability in varying temperature and harsh environment. Molybdenum (Mo) serves as the top layer/electrode. The thickness of the structural layers are optimized through MATLAB and also analyzed via Finite Element Analysis using Intellisuite. Two designs are proposed at low resonant frequency, one with conventional cantilever beam, the other being a T-shaped cantilever beam. Both structures are simulated and their performances are compared.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-P-34: Dose Perturbation Caused by Sun Nuclear QED Diode When Used for Very Small Electron Fields

Purpose: Diodes are utilized by radiotherapy departments to help verify that treatment fields are being delivered correctly to the patient. Some treatment fields utilize electron beams along with a cerrobend cutout to shape the beam to the area to be treated. Cerrobend cutouts can sometimes be very small < 2×2-cm2. Some published work has addressed diode perturbation for cutout sizes down to 1.5-cm, this work addresses the diode perturbation of the Sun Nuclear QEDTM diode for cutouts as small as 0.5-cm in diameter. Methods: Measurements were taken with an A16 Exradin micro-chamber in Solid Water to 100-cm SSD. Dmax was determined for each cutout using various amounts of Solid Water in 1–2 mm increments to account for the dmax shifting in small fields. The diode was placed on top of the solid water to 100-cm SSD in the center of the cutout. Measurements were taken with no diode for comparison. The cutouts ranged in diameter from 0.5-cm to 5.0-cm and included the open 6×6 insert. Measurements were made for energies 6, 9, 12, 15,&18 MeV. Results: For 6 MeV, the percent dose reduction from the diode in the cutout field compared to the field without the diode ranged from 35% to 25% as a function of cutout size. For higher energies, this percentage decreased and generally was 25% to 15%. It was observed that dmax shifts significantly upstream for very small cutouts (<2-cm diameter) to less than 1 cm for all energies. Conclusion: The presence of diodes in small electron fields is enough to cause significant dose perturbation to the target volume. It is recommended that diodes for very small electron fields be used sparingly or possibly with a dose correction per treatment fraction(s), if the total projected delivered dose is going to be significantly different from that prescribed by the physician.

60 APPLIED LIFE SCIENCES↗

SU-E-T-601: Output Factor Calculation of Irregular Shape Electron Cutout at Extended SSD

Purpose: To calculate the output factor of irregular shape electron beam at extended SSD using modified lateral build-up-ratio method. Methods: Circular cutouts from 2.0cm diameter to maximum possible sizes were prepared for applicator cone size of 15×15cm. In addition, different irregular cutouts were prepared. Percentage depth dose (PDD) curves were measured for each cutout using 6, 9, 12 and 16-MeV at the standard SSD of 100cm. The scanning was done using Multidata system and Scanditronix diodes on 2100SC Varian LINAC. In addition, for each cutout and electron beam energy doses were measured at SSD values of 100, 105, 110, 115cm using EDR2 films and diodes. Results: The measured PDD were normalized to the depth of 1.0mm. The lateral build-up-ratio (LBR) and the lateral scatter parameter (sigma) were calculated for each circular cutout using the open 15X15-cm2 field as the reference field. Taking the linear increase of sigma with cutout size into account, PDD of the irregular cutouts were calculated at 100 cm SSD. Furthermore, using the dose measured at different SSDs, the effective SSD value for each circular cutout and electron beam energy was determined. Employing the LBR and the effective-SSD values of the circular cutouts along with the calculated PDD of the irregular cutouts, the output factors of the irregular cutout at different extended SSD values were calculated. Finally, the calculated output factors were compared with the measured values. Conclusion: In this research, it is shown that output factor of irregular shape electron beam at extended SSD can be determined by using the LBR and the effective SSD values of circular cutouts. The percentage difference of the calculated output factor from the measured output factor for irregular cutouts at extended SSD were within 3.0%.

07 ISOTOPE AND RADIATION SOURCES↗

Impact of MLC leaf width on the quality of the dose distribution in partial breast irradiation

Partial-breast irradiation (PBI) aims to limit the target volume for radiotherapy in women with early breast cancer after partial mastectomy to the region at highest risk of local recurrence, the tumor bed. Multileaf collimators are used to achieve conformal radiation beam portals required for PBI. Narrower leaf widths are generally assumed to allow more conformal shaping of beam portals around irregularly shaped target volumes. The aim was to compare 5-mm and 10-mm leaf widths for patients previously treated using PBI and assess subsequent planning target volume (PTV) coverage and organ at risk (OAR) doses for 16 patients. Several plans (5-mm leaf width or 10-mm leaf width) were generated for each patient using the original treated plan as the basis for attempts at further optimization. Alternating between different leaf widths found no significant difference in terms of overall PTV coverage and OAR doses between treatment plans. Optimization of the original treated plan allowed a small decrease in ipsilateral breast dose, which was offset by a lower PTV minimum. No significant dosimetric difference was found to support an advantage of 5-mm over 10-mm leaf width in this setting.

61 RADIATION PROTECTION AND DOSIMETRY↗

Beamlet based direct aperture optimization for MERT using a photon MLC

Purpose: A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. Methods: The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose–volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. Results: For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. Conclusions: A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.

60 APPLIED LIFE SCIENCES↗

Topological shaping of vortex neutron beams using forked phase gratings

Beams of light or matter that carry well-defined states of orbital angular momentum (OAM) are promising probes of topological and textured condensed matter systems such as magnetic skyrmions. Using spin-echo small-angle neutron scattering, a phase-sensitive technique that allows for a relatively low intensity beam, we demonstrate the production of vortex neutron beams from forked phase gratings of various topological charges. This type of interferometric verification of OAM we present here could be further extended to other platforms using probes that are similarly limited by the coherence and strength of the currently available sources.

Cold atoms & matter waves↗

The Physics of Gain Mechanisms in a Self-Amplified Spontaneous Emission Free-Electron Laser

This is the final report for the DoE BES contract DE-FG02-07ER46272. This grant began under a title that gives its history in a few words: The Physics of Gain Mechanisms in a Self-Amplified Spontaneous Emission Free-Electron Laser. At the time of adopting this name, the UCLA Particle Beam Physics Laboratory (PBPL) was at the forefront of the first demonstrations of SASE FEL, giving the experimental basis for the 4th generation X-ray light source now exemplified by the LCLS, a remarkable generation of machines that have revolutionize nanoscale and ultrafast science. The grant title indicates that physical aspects of the FEL are of interest, and implies that progress requires comprehensive investigations. These aspects include: the physics and technology of high brightness electron beam generation, phase space manipulations, advanced beam diagnostics, state-of-the-art undulators, studies of FEL mode characteristics, as well as the introduction of new theoretical models and start-to-end simulations, all yielding a deep understanding of the SASE FEL. The latest period (2010-13) of BES grant support has been the most productive yet for the UCLA PBPL, and the extensive list of accomplishments is illustrative of our central contributions to advanced FEL research. We give a concise overview here and review our research results in further detail below. In FEL and ultrafast beam physics, we have experimentally investigated: production of helical beams and FEL modes with orbital angular momentum; chirp-taper single-spike FEL gain; new FROG techniques optimized for FEL, introduced coherent imaging of beam profiles using transition radiation; and demonstrated a next generation cryoundulator. We have performed deep theoretical studies of these phenomena and other advanced FEL physics concepts, such as the space-charge amplifier. In high brightness beams, we have: introduced a new class of hybrid photoinjector for <100 fs beam production; developed new approaches to self-shaped ellipsoidal beams; used nonlinear plasma oscillations to create beam pulse trains; tested new plasmonic, high quantum efficiency cathodes, and developed new methods of beam measurement with um spatial/sub-fs temporal resolution. In ultrafast imaging, we have: developed advanced electro-optic timing systems, performed the 1st pump-probe study using single shot UED, demonstrated continuously time-resolved UED with RF deflection; made initial use of inverse Compton scattering (ICS) X-ray sources in application through single-shot inline phase contrast imaging, established single-shot X-ray diffraction, and observed ICS high harmonic generation and redshifting due to nonlinear effects. In 5th generation light source research, we have developed the techniques of narrowband, very high power coherent Cerenkov radiation sources based on dielectric wakefield devices. This work is represented by numerous publications in leading journals: e.g. Nature Physics, Physical Review Letters, Applied Physics Letters. The PBPL program’s influence on the field also extends to organization of the electron beam applications community; we have organized the first international UED workshops and the initial two meetings dedicated to 5th generation light source.

43 PARTICLE ACCELERATORS↗

Ku-band multiple beam antenna

The frequency reuse capability is demonstrated for a Ku-band multiple beam antenna which provides contiguous low sidelobe spot beams for point-to-point communications between any two points within the continental United States (CONUS), or regional coverage beams for direct broadcast systems. A spot beam antenna in the 14/21 GHz band which provides contiguous overlapping beams covering CONUS and two discrete beams covering Hawaii and Alaska were designed, developed, and tested. Two reflector antennas are required for providing contiguous coverage of CONUS. Each is comprised of one offset parabolic reflector, one flat polarization diplexer, and two separate planar array feeds. This antenna system provides contiguous spot beam coverage of CONUS, utilizing 15 beams. Also designed, developed and demonstrated was a shaped contoured beam antenna system which provides contiguous four time zone coverage of CONUS from a single offset parabolic reflector incorporating one flat polarization diplexer and two separate planar array feeds. The beams which illuminate the eastern time zone and the mountain time zone are horizontally polarized, while the beams which illuminate the central time zone and the pacific time zone are vertically polarized. Frequency reuse is achieved by amplitude and polarization isolation.

Chen, C. C.↗

Method for shaping and aiming narrow beams

A sonar method and apparatus is discribed which utilizes a linear frequency chirp in a transmitter/receiver having a correlator to synthesize a narrow beamwidth pattern from otherwise broadbeam transducers when there is relative velocity between the transmitter/receiver and the target. The chirp is so produced in a generator in bandwidth, B, and time, T, as to produce a time bandwidth product, TB, that is increased for a narrower angle. A replica of the chirp produced in a generator is time delayed and Doppler shifted for use as a reference in the receiver for correlation of received chirps from targets. This reference is Doppler shifted to select targets preferentially, thereby to not only synthesize a narrow beam but also aim the beam in azimuth and elevation.

Heyser, R. C.↗

Reflectors Made from Membranes Stretched Between Beams

Lightweight cylindrical reflectors of a proposed type would be made from reflective membranes stretched between pairs of identically curved and identically oriented end rails. In each such reflector, the curvature of the two beams would define the reflector shape required for the intended application. For example, the beams could be curved to define a reflector of parabolic cross section, so that light incident along the axis of symmetry perpendicular to the cylindrical axis would be focused to a line. In addition, by applying suitable forces to the ends of the beams, one could bend the beams to adjust the reflector surface figure to within a precision of the order of the wavelength of the radiation to be reflected. The figure depicts an example of beams shaped so that in the absence of applied forces, each would be flat on one side and would have a radius of curvature R on the opposite side. Alternatively, the curvature of the reflector-membrane side could be other than circular. In general, the initial curvature would be chosen to optimize the final reflector shape. Then by applying forces F between the beam ends in the positions and orientations shown in the figure, one could bend beams to adjust their shape to a closer approximation of the desired precise circular or noncircular curvature.

Dooley, Jennifer↗