Effects of Background Pressure and Electrical Configuration on the Velocity Field of the HERMeS Hall Thruster

A Laser-Induced Fluorescence test was performed during risk reduction testing on the HERMeS Hall thruster. This article focuses on the portion of the test to study trends in the ion acceleration characteristics with varying anode mass flow rate, background pressure, and electrical configuration. The acceleration zone of the HERMeS Hall thruster was observed to move upstream as the anode mass flow rate decreased and upstream as the background pressure increased. Examination of the characteristics of the ions near the pole covers suggested the possibility that thruster was no longer magnetically shielded at the extreme conditions of very low anode mass flow rate and high background pressure. The acceleration zone was also observed to move slightly upstream when the thruster body was floated as opposed to cathode-tied and did not move appreciably when the thruster body was grounded to the vacuum facility. Characteristics of the ions bombarding the pole covers did not vary across the tested electrical configurations.

Electric Propulsion↗

Modeling Electrolytic O2 Recovery from Metabolic CO2 for Advanced Closed Loop Life Support Systems in Extraterrestrial Human Missions

The International Space Station (ISS) is currently equipped with a complex, heavy, and power consuming system that recovers approximately 50% of O2 from metabolic CO2. Future long duration human missions to the Moon and Mars will necessitate a sustainable and highly efficient metabolic oxygen recovery system capable of yielding a minimum of 75% O2 recovery. A Macrofluidic Electrochemical Reactor (MFECR) technology development effort is currently underway at NASA Marshall Space Flight Center (MSFC) to significantly increase current metabolic O2 recovery efficiency, expand mission sustainability, and reduce complexity of the system. The novel design combines CO2 conversion to O2 along with C2H4 as byproduct and water electrolysis (currently conducted in two separate units) into a single compact unit that runs at standard conditions and is theoretically capable of generating O2 with a theoretical maximum metabolic CO2 conversion of 73% while consuming less than metabolic water. This paper presents a comprehensive multi-physic 3D model developed at MSFC on CO2 conversion to O2 and C2H4 at standard conditions via MFECR. The 3D spatial domain of the model is a replica of the actual MFECR’s 3D drawing generated for the MFECR fabrication and operated to recover O2 from CO2 yielding C2H4 as byproduct. Electrochemical (EC) physics that includes EC multicomponent reaction mechanisms, mass transport, and electrical current density distributions is coupled in the model with all the other physics phenomena involved in the MFECR’s process, such as two-phase flow, free and porous fluid regimes, multicomponent mass transfer, heat transfer, and DC electrical current generation along with Joule heating effect. The EC reaction sections of the MFECR consists of two porous gas diffusion electrodes (GDE) and an electrolyte serpentine channel sandwiched in the middle. The CO2 feeds the cathode serpentine channel and part of the O2 product is fed back to the anode serpentine chamber. An alkaline solution feeds the electrolyte serpentine chamber wetting the GDEs of both, the anode and cathode allowing the OH- ionic transport between them. The EC reactions in the cathode’s GDE yield C2H4 from CO2 and H2 from water while the EC reaction in the anode’s GDE yields O2. The authors will present in this paper the validation of the model using experimental data and the utilization of the validated model in building a reliable simulator that will not only assist the authors on the MFECR design but also the optimization of its operation in the ISS and future spatial human missions.

Jesus A Dominguez↗

Ion Velocity Characterization of the 12.5-kW Advanced Electric Propulsion System Engineering Hall Thruster

During development testing of the 12.5-kW Advanced Electric Propulsion System engineering unit Hall thruster, which is magnetically shielded, a laser-induced fluorescence test was performed. During this test, a third medium-energy ion population was found near the inner front pole cover in addition to two low-energy counter-streaming ion populations that were found in previous testing. This newly found ion population matched in characteristics with the single population found near the outer front pole cover. The measured characteristics of the medium-energy ions matched the behavior expected of them if they were energized by a plasma wave with magnetized electrons, such as a lower hybrid wave. Comparison of the data from this test to prior tests showed that this engineering thruster had very similar ion characteristics as the precursor laboratory thruster. The acceleration zone was found to move upstream with increasing background pressure, decreasing anode flowrate, and increasing magnetic field strength. For the low-energy ions, the energy of the ions arriving at the inner pole did not vary noticeably with background pressure but did increase with increasing magnetic field strength and decreasing anode flow rate. For the medium-energy ions, the energy of the ions increased with decreasing background pressure, decreasing anode flow rate, and increasing magnetic field strength. Testing at different cathode flow fraction showed that the energy of the low-energy ions from the cathode decreased with increasing cathode flow.

Electric propulsion↗

Origin of hot ions observed in a modified Penning discharge

Ions with a Maxwellian energy distriubtion and kinetic temperatures ranging from below 100 eV to several keV are observed in a steady state modified Penning discharge. Observations in the plasma, with capacitive probes at several azimuthal locations, are consistent with the existence of two distinct spokes rotating with different velocities in the sheath between the plasma and the anode ring. The faster (0.5 to 10 MHz) spoke consists of electrons rotating with the E/B drift velocity. The slow (0.1 to 1.0 MHz) spoke consists of ions whose measured thermal velocity is directly proportional to the spoke velocity. The interaction of the two spokes is apparently responsible for the observed electrostatic turbulence and ion thermalization. The anode sheath thickness is smaller than the ion gyrodiameter in this plasma. Thus the ions are in the electric field of the sheath for only a fraction of their orbit, and their E/B drift (spoke) velocity is smaller than that of the electrons.

Roth, J. R.↗

Mechanisms for the adhesion of silver to glow discharge sensitized perfluorinated ethylene propylene (PEP)

Details are given for the deposition of silver onto FEP for a batch coater capable of handling 864 square inches at a time. The effectiveness of the glow discharge is shown to be optimum when the FEP faces the anode. Using solid state theory based upon the work function difference, and the heuristic assumption that the surface of FEP is populated with fluoride ions, it is argued that an anode sensitized surface develops states receptive to electron transfer from silver, whereas a cathode sensitized surface is polarized only, and as a result cannot permanently trap charge. Thermodynamic arguments given show that an order of magnitude of 10 to the 9th power electrons are transferred into states to a depth of 10 nm.

Schutt, J. B.↗

Mass, momentum and energy flow from an MPD accelerator

The mass, momentum, and energy flows are measured over a current range of 8 to 50 kA and inlet mass flows of 2 to 36q/sec of argon. The momentum flux profile indicates that the accelerator produces a uniform, 2-inch diameter axial jet at the anode which expands into a Gaussian profile at an axial station 11 inches from the anode. The electromagnetic component of the thrust is found to follow the familiar quadratic dependence on arc current, while a more complex empirical relation is needed to correlate the gasdynamic contribution with the current and mass flow rate. Using available time-of-flight velocity profiles at a current of 16 kA and a mass flow of 5.9 g/sec, calculated flux profiles of mass and kinetic energy exhibit a tendency for some fraction of the inlet mass flow to leak out at a low velocity around the central high velocity core.

Cory, J. S.↗

Investigation of failure mechanisms in integrated vacuum circuits

The fabrication techniques of integrated vacuum circuits are described in detail. Data obtained from a specially designed test circuit are presented. The data show that the emission observed in reverse biased devices is due to cross-talk between the devices and can be eliminated by electrostatic shielding. The lifetime of the cathodes has been improved by proper activation techniques. None of the cathodes on life test has shown any sign of failure after more than 3500 hours. Life tests of triodes show a decline of anode current by a factor of two to three after a few days. The current recovers when the large positive anode voltage (100 V) has been removed for a few hours. It is suggested that this is due to trapped charges in the sapphire substrate. Evidence of the presence of such charges is given, and a model of the charge distribution is presented consistent with the measurements. Solution of the problem associated with the decay of triode current may require proper treatment of the sapphire surface and/or changes in the deposition technique of the thin metal films.

Rosengreen, A.↗

The influence of modifications of a fatigue loading history program on fatigue lifetime

Rectangular specimens of 7075 and 2014 aluminum alloys with two holes (stress concentration factor of 3.24) have been tested under axial fatigue loading on a six-rod test bed with modifications of the loading program, the surface particulars, and the frequency. The length of the precrack stage was investigated by use of a new crack detector. In most cases the two alloys behaved similarly, with similar life to crack start under the same loading. Some overloads lengthened the life. Truncation by omission of the lowest peak loads should be limited to about 20 percent of the ultimate load. Simplifying counting methods gave misleading results. Very thin surface layers of anodizing, protection by vinyl, dry nitrogen atmosphere, as well as stepwise reaming or grinding the surface of the holes, lengthened the life; thick anodized layers shortened the life. Compressing the hole surface by rolling had no influence. Frequencies at about 210 to 240 cpm produced shorter lives than those at 40 cpm. At 5.4 cpm the life was considerably longer. A model to better understand the precrack-stage fatigue mechanism is discussed.

Branger, J.↗

Pulsed electromagnetic gas acceleration

Photographs of the exhaust plume of a pulsed MPD discharge through selected narrow band spectral filters reveal a species structure related to the location of the argon mass injection ports. This species structure provides the key to interpretation of time-resolved interferometric velocity measurements in the exhaust. The resulting exhaust velocity increases monotonically from 8500 m/sec at a position 5 cm downstream of the anode face to 16,500 m/sec 40 cm downstream. The latter value is approximately twice the Alfven critical speed for argon. The growth of the axial electric field near the downstream face of the anode indicates that the discharge operates in a starved mode. Data from biased double probes imply an electron temperature of 0.8 eV in the exhaust plume.

Jahn, R. G.↗

Origin of hot ions observed in a modified Penning discharge.

Ions with a Maxwellian energy distribution and kinetic temperatures ranging from below 100 eV to several keV have been observed in a steady-state modified Penning discharge. Observations in the plasma, with capacitive probes at several azimuthal locations, are consistent with the existence of two distinct spokes rotating with different velocities in the sheath between the plasma and the anode ring. The faster (0.5-10 MHz) spoke consists of electrons rotating with the E/B drift velocity. The slow (0.1-1.0 MHz) spoke consists of ions, the measured thermal velocity of which is directly proportional to the spoke velocity. The interaction of the two spokes is apparently responsible for the observed electrostatic ?turbulence' and ion thermalization. The anode sheath thickness is smaller than the ion gyrodiameter in this plasma. Thus the ions are in the electric field of the sheath for only a fraction of their orbit, and their E/B drift (spoke) velocity is smaller than that of the electrons.

Roth, J. R.↗

Rechargeable Al/Cl2 battery with molten AlCl4/-/ electrolyte.

A molten salt system based on Al- and Cl2 carbon electrodes, with an AlCl3 alkali chloride eutectic as electrolyte, offers promise as a rechargeable, high energy density battery which can operate at a relatively low temperature. Electrode kinetic studies showed that the electrode reactions at the Al anode were rapid and that the observed passivation phenomena were due to the formation at the electrode surface of a solid salt layer resulting from concentration changes on anodic or cathodic current flow. It was established that carbon electrodes were intrinsically active for chlorine reduction in AlCl3-alkali chloride melts. By means of a rotating vitreous carbon disk electrode, the kinetic parameters were determined.

Holleck, G. L.↗

Sputter erosion and deposition in the discharge chamber of a small mercury ion thruster

A 5 cm diameter mercury ion thruster similar to one tested for 9715 hours was operated approximately 400 hrs each at discharge voltages of 36.6, 39.6, and 42.6 V, with corresponding discharge propellant utilizations of 58, 68, and 70 percent. The observed sputter erosion rates of the internal thruster parts and the anode weight gain rate all rose rapidly with discharge voltage and were roughly in the ratio of 1:3:5 for the three voltages. The combined weight loss of the internal thruster parts nearly balanced the anode weight gain. Hg(+2) ion apparently caused most of the observed erosion.

Power, J. L.↗

Quasi-steady plasma acceleration.

A coaxial plasma accelerator driven by protracted pulses of current in the range of 10,000 to 100,000 A and synchronized mass flows from 1.0 to 36 g/sec argon attains, after some tens of microseconds, a stable magnetoplasmadynamic acceleration mode. This 'quasi-steady' discharge form is characterized by constant terminal voltage and current, a diffuse, fixed current distribution within the discharge, and a steady plasma efflux at velocities of approximately 20 km/sec. Measured potential distributions reveal that the bulk of the arc voltage gradient, exclusive of the electrode falls, occurs within two diameters of the cathode, and is normal to it. The anode fall voltage varies inversely with local current density, implying substantially lower anode losses at higher power arc operation. Spectroscopic, potential, and velocity measurements indicate the existence of a characteristic mass flow rate for a given current, below which arc operation becomes erratic.

Jahn, R. G.↗