Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analog computation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Nonvolatile Array Of Synapses For Neural Network

Elements of array programmed with help of ultraviolet light. A 32 x 32 very-large-scale integrated-circuit array of electronic synapses serves as building-block chip for analog neural-network computer. Synaptic weights stored in nonvolatile manner. Makes information content of array invulnerable to loss of power, and, by eliminating need for circuitry to refresh volatile synaptic memory, makes architecture simpler and more compact.

Tawel, Raoul↗

Evaluation of a vibration diagnostic system for the detection of spur gear pitting failures

A vibration diagnostic system was used to detect spur gear surface pitting fatigue in a closed-loop spur gear fatigue test rig. The diagnostic system, comprising a personal computer with an analog-to-digital conversion board, a diagnostic system unit, and software, uses time-synchronous averaging of the vibration signal to produce a vibration image of each tooth on any gear in a transmission. Several parameters were analyzed including gear pair stress wave and raw baseband vibration, kurtosis, peak ratios, and others. The system provides limits for the various parameters and gives a warning when the limits are exceeded. Several spur gear tests were conducted with this system and vibration data analyzed at 5-min. intervals. The results presented herein show that the system is fairly effective at detecting spur gear tooth surface fatigue pitting failures.

Townsend, Dennis P.↗

Evaluation of a vibration diagnostic system for the detection of spur gear pitting failures

A vibration diagnostic system was used to detect spur gear surface pitting fatigue in a closed-loop spur gear fatigue test rig. The diagnostic system, comprising a personal computer with an analog-to-digital conversion board, a diagnostic system unit, and software, uses time-synchronous averaging of the vibration signal to produce a vibration image of each tooth on any gear in a transmission. Several parameters were analyzed including gear pair stress wave and raw baseband vibration, kurtosis, peak ratios, and others. The system provides limits for the various parameters and gives a warning when the limits are exceeded. Several spur gear tests were conducted with this system and vibration data analyzed at 5-min. intervals. The results presented herein show that the system is fairly effective at detecting spur gear tooth surface fatigue pitting failures.

Townsend, Dennis P.↗

Tensor-GMRES method for large sparse systems of nonlinear equations

This paper introduces a tensor-Krylov method, the tensor-GMRES method, for large sparse systems of nonlinear equations. This method is a coupling of tensor model formation and solution techniques for nonlinear equations with Krylov subspace projection techniques for unsymmetric systems of linear equations. Traditional tensor methods for nonlinear equations are based on a quadratic model of the nonlinear function, a standard linear model augmented by a simple second order term. These methods are shown to be significantly more efficient than standard methods both on nonsingular problems and on problems where the Jacobian matrix at the solution is singular. A major disadvantage of the traditional tensor methods is that the solution of the tensor model requires the factorization of the Jacobian matrix, which may not be suitable for problems where the Jacobian matrix is large and has a 'bad' sparsity structure for an efficient factorization. We overcome this difficulty by forming and solving the tensor model using an extension of a Newton-GMRES scheme. Like traditional tensor methods, we show that the new tensor method has significant computational advantages over the analogous Newton counterpart. Consistent with Krylov subspace based methods, the new tensor method does not depend on the factorization of the Jacobian matrix. As a matter of fact, the Jacobian matrix is never needed explicitly.

Feng, Dan↗

Data collection in IMS: It's not as easy as it looks

Data collection in Ion Mobility Spectrometry (IMS) is not as easy an endeavor as it appears. Despite the advent of high speed personal computers and fast analog-to-digital converters (ADC's), care must be taken to ensure that reliable data are obtained in a timely fashion. This is especially true in hyphenated techniques, e.g. GC-IMS, where the amount of data increases dramatically when gas chromatography-ion mobility spectrometry (GC-IMS) data is being collected. Using the Graseby GC-IMS, with a gate repetition rate of 33 Hz, it is theoretically possible to collect 33 spectra per second. This collection rate is not realistically obtained due to a number of factors. Among these factors are inaccuracy of the timing signal from the IMS, the necessity to store the data, disk input/output limitations, disk operating system limitations, and program overhead. Taking these factors into account, we have achieved a data collection rate of 20 spectra per second. This paper will describe these problems, demonstrate the practical effects these problems present, and present methods for minimizing these effects.

Davis, Dennis M.↗

Evaluation Of Vibration-Monitoring Gear-Diagnostic System

Report describes experimental evaluation of commercial electronic system designed to monitor vibration signal from accelerometer on gear-box to detect vibrations indicative of damage to gears. System includes signal-conditioning subsystem and personal computer in which analog-to-digital converter installed. Results show system fairly effective in detecting surface fatigue pits on spur-gear teeth.

Townsend, Dennis P.↗

PIV Investigations of the Flow Field in the Volute of a Rotary Blood Pump

A full-size acrylic model of a rotary blood pump was developed in order to utilize Particle Image Velocimetry (PIV) to make measurements of the fluid velocities and turbulent stresses throughout the device. The development of an understanding of the hemodynamics within the blood pump is critical to the development and validation of computational models. A blood analog solution, consisting of sodium iodide solution and glycerin, was developed to match physiological kinematic viscosity. The refractive indecies of the fluid, the pump casing and the impeller were matched to facilitate the use of PIV to make velocity measurements. Velocity measurements made in the volute exit/diffuser region are presented for pumps speeds of 3000-3850 rpm. At each speed data were obtained at a physiological pressure of 90 mmHg and at a maximum flow condition. Four hundred data pairs were used for each resultant mean velocity vector value, representing greater than an order of magnitude more data pairs than reported previously in the literature on similar devices and resulting in velocity uncertainty levels of approximately 2.9%.

Sankovic, John M.↗

Improving Evolvability through Generative Representations

One of the main limitations of computer automated design systems is the representation used for encoding designs. Using computer programs as an analogy, representations can be thought of as having the properties of combination, control-flow and abstraction. Generative representations are those which have the ability to reuse elements in an encoding through either iteration, a form of control-flow, or abstraction. Here we argue that generative representations improve the evolvability of designs by capturing design dependencies in a way that makes them easier to change, and we support this with examples from two design substrates.

Hornby, Gregory S.↗

PIV Investigations of the Flow Field in the Volute of a Rotary Blood Pump

A full-size acrylic model of a rotary blood pump was developed in order to utilize Particle Image Velocimetry (PIV) to make measurements of the fluid velocities and turbulent stresses throughout the device. The development of an understanding of the hemodynamics within the blood pump is critical to the development and validation of computational models. A blood analog solution, consisting of sodium iodide solution and glycerin, was developed to match physiological kinematic viscosity. The refractive indices of the fluid, the pump casing, and the impeller were matched to facilitate the use of PIV to make velocity measurements. Velocity measurements made in the volute exit/diffuser region are presented for pumps speeds of 3000-3850 rpm. At each speed data were obtained at a physiological pressure of 12 kPa and at a maximum flow condition. Four hundred data pairs were used for each resultant mean velocity vector value, representing greater than an order of magnitude more data pairs than reported previously in the literature on similar devices and resulting in velocity uncertainty levels of approximately 22.9%.

Sankovic, John M.↗

High-Temperature Switched-Reluctance Electric Motor

An eight-pole radial magnetic bearing has been modified into a switched-reluctance electric motor capable of operating at a speed as high as 8,000 rpm at a temperature as high as 1,000 F (=540 C). The motor (see figure) is an experimental prototype of starter-motor/generator units that have been proposed to be incorporated into advanced gas turbine engines and that could operate without need for lubrication or active cooling. The unique features of this motor are its electromagnet coils and, to some extent, its control software. Heretofore, there has been no commercial-off-the-shelf wire capable of satisfying all of the requirements for fabrication of electromagnet coils capable of operation at temperatures up to 1,000 F (=540 C). The issues addressed in the development of these electromagnet coils included thermal expansion, oxidation, pliability to small bend radii, micro-fretting, dielectric breakdown, tensile strength, potting compound, thermal conduction, and packing factor. For a test, the motor was supported, along with a rotor of 18 lb (.8-kg) mass, 3-in. (.7.6-cm) diameter, 21-in. (.53-cm) length, on bearings packed with high-temperature grease. The motor was located at the mid span of the rotor and wrapped with heaters. The motor stator was instrumented with thermocouples. At the time of reporting the information for this article, the motor had undergone 14 thermal cycles between room temperature and 1,000 F (.540 C) and had accumulated operating time >27.5 hours at 1,000 F (=540 C). The motor-controller hardware includes a personal computer equipped with analog-to-digital input and digital-to-analog output cards. The controller software is a C-language code that implements a switched-reluctance motor-control principle: that is, it causes the coils to be energized in a sequence timed to generate a rotating magnetic flux that creates a torque on a scalloped rotor. The controller can operate in an open- or closed-loop mode. In addition, the software has been modified to enable the simultaneous operation of the prototype motor or another, similar apparatus as both a motor and a magnetic bearing. Combined bearing/motor operation has been demonstrated at room temperature but had not yet been demonstrated at high temperature at the time of reporting the information for this article.

Montague, Gerald↗

Efficiently Verifiable Quantum Advantage on Near-Term Analog Quantum Simulators

Existing schemes for demonstrating quantum computational advantage are subject to various practical restrictions, including the hardness of verification and challenges in experimental implementation. Meanwhile, analog quantum simulators have been realized in many experiments to study novel physics. In this work, we propose a quantum advantage protocol based on verification of an analog quantum simulation, in which the verifier need only run an O ( λ 2 ) -time classical computation, and the prover need only prepare O ( 1 ) samples of a history state and perform O ( λ 2 ) single-qubit measurements, for a security parameter λ . We also propose a near-term feasible strategy for honest provers and discuss potential experimental realizations. Published by the American Physical Society 2025

Liu, Zhenning (ORCID:000000020794419X)↗

Some system considerations in configuring a digital flight control - navigation system

A trade study was conducted with the objective of providing a technical guideline for selection of the most appropriate computer technology for the automatic flight control system of a civil subsonic jet transport. The trade study considers aspects of using either an analog, incremental type special purpose computer or a general purpose computer to perform critical autopilot computation functions. It also considers aspects of integration of noncritical autopilot and autothrottle modes into the computer performing the critical autoland functions, as compared to the federation of the noncritical modes into either a separate computer or with a R-Nav computer. The study is accomplished by establishing the relative advantages and/or risks associated with each of the computer configurations.

Boone, J. H.↗

Toward Mixed Analog-Digital Quantum Signal Processing: Quantum AD/DA Conversion and the Fourier Transform

Signal processing stands as a pillar of classical computation and modern information technology, applicable to both analog and digital signals. Recently, advancements in quantum information science have suggested that quantum signal processing (QSP) can enable more powerful signal processing capabilities. However, the developments in QSP have primarily leveraged digital quantum resources, such as discrete-variable (DV) systems like qubits, rather than analog quantum resources, such as continuous-variable (CV) systems like quantum oscillators. Consequently, there remains a gap in understanding how signal processing can be performed on hybrid CV-DV quantum computers. Here we address this gap by developing a new paradigm of mixed analog-digital QSP. We demonstrate the utility of this paradigm by showcasing how it naturally enables analog-digital conversion of quantum signals—specifically, the transfer of states between DV and CV quantum systems. We then show that such quantum analog-digital conversion enables new implementations of quantum algorithms on CV-DV hardware. This is exemplified by realizing the quantum Fourier transform of a state encoded on qubits via the free-evolution of a quantum oscillator, albeit with a runtime exponential in the number of qubits due to information theoretic arguments. Collectively, this work marks a significant step forward in hybrid CV-DV quantum computation, providing a foundation for scalable analog-digital signal processing on quantum processors.

42 ENGINEERING↗

A Quantum Analog Coprocessor for Correlated Electron Systems Simulation

Analog quantum simulation is an approach for studying physical systems that might otherwise be computationally intractable to simulate on classical high-performance computing (HPC) systems. The key idea behind analog quantum simulation is the realization of a physical system with a low-energy effective Hamiltonian that is the same as the low-energy effective Hamiltonian of some target system to be studied. Purpose-built nanoelectronic devices are a natural candidate for implementing the analog quantum simulation of strongly correlated materials that are otherwise challenging to study using classical HPC systems. However, realizing devices that are sufficiently large to study the properties of a non-trivial material system (e.g., those described by a Fermi-Hubbard model) will eventually require the fabrication, control, and measurement of at least 0(10) quantum dots, or other engineered quantum impurities. As a step toward large-scale analog or digital quantum simulation platforms based on nanoelectronic devices, we propose a new approach to analog quantum simulation that makes use of the large Hilbert space dimension of the electronic baths that are used to adjust the occupancy of one or a few engineered quantum impurities. This approach to analog quantum simulation allows us to study a wide array of quantum impurity models. We can further augment the computational power of such an approach by combining it with a classical computer to facilitate dynamical mean-field theory (DMFT) calculations. DMFT replaces the solution of a lattice impurity problem with the solution of a family of localized impurity problems with bath couplings that are adjusted to satisfy a self-consistency condition between the two models. In DMFT, the computationally challenging task is the high-accuracy solution of an instance of a quantum impurity model that is determined self-consistently in coordination with a mean-field calculation. We propose using one or a few engineered quantum impurities with adjustable couplings to baths to realize an analog quantum coprocessor that effects the solution of such a model through measurements of a physical quantum impurity, operating in coordination with a classical computer to achieve a self-consistent solution to a DMFT calculation. We focus on implementation details relevant to a number of technologies for which Sandia has design, fabrication, and measurement expertise. The primary technical advances outlined in this report concern the development of a supporting modeling capability. As with all analog quantum simulation platforms, the successful design and operation of individual devices depends critically on one's ability to predict the effective low-energy Hamiltonian governing its dynamics Our project has made this possible and lays the foundation for future experimental implementations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time simulation of an automotive gas turbine using the hybrid computer

A hybrid computer simulation of an Advanced Automotive Gas Turbine Powertrain System is reported. The system consists of a gas turbine engine, an automotive drivetrain with four speed automatic transmission, and a control system. Generally, dynamic performance is simulated on the analog portion of the hybrid computer while most of the steady state performance characteristics are calculated to run faster than real time and makes this simulation a useful tool for a variety of analytical studies.

Costakis, W.↗

Efficacy of Compression Garments to Simulate Fluid Shifts during Lunar Bedrest

The effectiveness of JOBST(Registered TradeMark) compression stockings for fluid redistribution was examined in the lunar bed rest analog based on Digital Astronaut computer model predictions. NASA's future goals include missions to the moon which will require extended exposure to the lunar gravity environment. To prepare for these missions, physiological adaptations in various systems must be resolved. A bed rest at a 10 degree head-up tilt was used to simulate lunar gravity. Plasma volume (PV) loss may cause some of the cardiovascular adaptations which occur during space flight so PV is measured in the bed rest analog to evaluate fluid loss. PV varies from individual to individual so PV index (PVI) is used to determine the magnitude and time course of fluid shift and cardiovascular adaptation to 1/6 g. The Digital Astronaut, a computer simulation tool, predicts a 6% PV loss during an extended simulated lunar mission for a male with a body surface area of 1.95 m(exp 2). Simple geometry calculations suggest that 10 degree head-up tilt is most useful for simulated measurement of deconditioning in bone and muscle, however, 2 degree head-up tilt may best imitate cardiovascular fluid shifts. In order to reconcile these different models, compression stocking must be used in the 10 degree paradigm to better approximate expected cardiovascular changes.

Brinley, Alaina↗