Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Cold Climate Air-Source Heat Pump Demonstration and Analysis: Experimental Study on Cold Temperature Performance

Space heating energy is the largest end use for U.S. residential buildings, accounting for nearly 45% of residential building energy consumption nationwide, and approximately 51% of space heating energy is consumed on-site by combusting natural gas (EIA 2020a). In Colorado, approximately 53% of the statewide residential building energy consumption goes to space heating, 76% of which is provided by natural gas (EIA 2020a). Heat pumps are an efficient, electric alternative space heating technology and have been proven viable for decades. However, historically air-source heat pumps (ASHPs) have been limited to temperate climates because of (1) subpar performance at extremely cold outdoor air temperatures, (2) the need for air conditioning in summer months, and (3) the availability of natural gas in colder climates. Relatively recent advances to cold climate ASHP technology, which typically relies on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance, enabling the technology to potentially save energy for many homes in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient performance of fan engine with water ingestion

In a continuing investigation on effects of rain-water ingestion into bypass fan engines, it is shown that the performance of axial-flow compressors and fans is fundamentally time-dependent during ingestion of water. A code named WINCOF-I has been developed for establishing the performance of axial-flow turbomachinery operating with air-water vapor-water droplet-water film mixture, Illustrative examples of predictions and effects are provided for the case of the air-compression system of a generic bypass fan engine. Utilizing performance maps so-generated, the effects of water ingestion into the generic engine have been determined under test cell conditions simulating ingestion, flight operation (altitude and flight Mach number), and power-demand setting.

Murthy, S. N. B.↗

Turbine for ordnance turbojet engine. 2: Cold-air performance with opened stator

A single-stage axial-flow turbine was investigated to determine the effect of increased stator throat area on the performance level of a turbojet engine turbine. The stator blades were bent to increase the throat area in order to move the compressor operating point in the engine farther away from surge. Results are compared with those obtained with the as-cast stator setting.

Kofskey, M. G.↗

High-Speed Cascade Tests of the NACA 65-(12A(sub 10))10 and NACA 65-(12A(sub 2)I(sub 8b))10 Compressor Blade Sections

Two-dimensional porous-well cascade tests of the NACA 65- (l2Al0) 10 and NACA 65-(l2A2I8b)10 blade sections were made at Mach numbers from 0.3 to choking in most cases. Data were obtained at solidities of 1.0 and 1.5 et inlet-air angles of 45 deg. and 60 deg. for both blade sections. With a solid--wall modification to the cascade tunnel, schlieren observations were made of the flow in cascade at a solidity of 1.5 and inlet-air angle of 45 deg. and at a solidity of 1.0 and inlet-air angle of 60 deg. Test results for the NACA 65-(12A10)l0 blade section show t hat the turning angles measured at low speed do not change significantly as the speed increases until the critical Mach number is exceed. Because of increasing separation from the highly cambered trailing-edge region, the turning angles for the NACA 65-(12A2I8b)10 blade section decreased as much as 4 deg. from low speed to critical speed. The high-speed performance of the NACA 65-(12A10)10 and the NACA 65-(12A2I8b)l0 blade sections is largely determined by the passage area distribution. The angle of attack for best operation at high Mach numbers is higher than the design angle of attack selected at low speed to have pressure distributions that are free of peaks.

Dunavant, James C.↗

Estimating Total Methane Emissions from the Denver-Julesburg Basin Using Bottom-Up Approaches

Methane is a powerful greenhouse gas with a 25 times higher 100-year warming potential than carbon dioxide and is a target for mitigation to achieve climate goals. To control and curb methane emissions, estimates are required from the sources and sectors which are typically generated using bottom-up methods. However, recent studies have shown that national and international bottom-up approaches can significantly underestimate emissions. In this study, we present three bottom-up approaches used to estimate methane emissions from all emission sectors in the Denver-Julesburg basin, CO, USA. Our data show emissions generated from all three methods are lower than historic measurements. A Tier 1/2 approach using IPCC emission factors estimated 2022 methane emissions of 358 Gg (0.8% of produced methane lost by the energy sector), while a Tier 3 EPA-based approach estimated emissions of 269 Gg (0.2%). Using emission factors informed by contemporary and region-specific measurement studies, emissions of 212 Gg (0.2%) were calculated. The largest difference in emissions estimates were a result of using the Mechanistic Air Emissions Simulator (MAES) for the production and transport of oil and gas in the DJ basin. The MAES accounts for changes to regulatory practice in the DJ basin, which include comprehensive requirements for compressors, pneumatics, equipment leaks, and fugitive emissions, which were implemented to reduce emissions starting in 2014. The measurement revealed that normalized gas loss is predicted to have been reduced by a factor of 20 when compared to 10-year-old normalization loss measurements and a factor of 10 less than a nearby oil and production area (Delaware basin, TX); however, we suggest that more measurements should be made to ensure that the long-tail emission distribution has been captured by the modeling. This study suggests that regulations implemented by the Colorado Department of Public Health and Environment could have reduced emissions by a factor of 20, but contemporary regional measurements should be made to ensure these bottom-up calculations are realistic.

03 NATURAL GAS↗

Detonation duct gas generator demonstration program

The feasibility of the generation of detonation waves moving periodically across high speed channel flow is experimentally demonstrated. Such waves are essential to the concept of compressing requirements and increasing the engine pressure compressor with the objective of reducing conventional compressor requirements and increasing the engine thermodynamic efficiency through isochoric energy addition. By generating transient transverse waves, rather than standing waves, shock wave losses are reduced by an order of magnitude. The ultimate objective is to use such detonation ducts downstream of a low pressure gas turbine compressor to produce a high overall pressure ratio thermodynamic cycle. A 4 foot long, 1 inch x 12 inch cross-section, detonation duct was operated in a blow-down mode using compressed air reservoirs. Liquid or vapor propane was injected through injectors or solenoid valves located in the plenum or the duct itself. Detonation waves were generated when the mixture was ignited by a row of spark plugs in the duct wall. Problems with fuel injection and mixing limited the air speeds to about Mach 0.5, frequencies to below 10 Hz, and measured pressure ratios of about 5 to 6. The feasibility of the gas dynamic compression was demonstrated and the critical problem areas were identified.

Wortman, Andrew↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Low-speed cascade investigation of loaded leading-edge compressor blades

Six percent thick NACA 63-series compressor-blade sections having a loaded leading-edge A4K6 mean line have been investigated systematically in a two-dimensional porous-wall cascade over a range of Reynolds numbers from 160,000 to 385,000. Blades cambered to have isolated-airfoil lift coefficients of 0.6, 1.2, 1.8, and 2.4 were tested over the usable angle-of-attack range at inlet-air angles of 30 degrees, 45 degrees, and 60 degrees and solidities of 1.0 and 1.5. A comparison with data of NACA RM L51G31, shows that the angle-of-attack operating range is 2 degrees to 4 degrees less than the range for the uniformly loaded section; however, the wake losses near design angle of attack are slightly lower than those for the uniformly loaded section. Except for highly cambered blades at high inlet angles, the 63-(C s oA4K6)06 compressor-blade sections are capable of more efficient operation for moderate-speed subsonic compressors at design angle of attack than are the 65-(C s oa10)10 or the 65-(c s oA2I8b)10 compressor-blade sections. In contrast to the other sections, the loaded leading-edge sections are capable of operating efficiently at the lower Reynolds numbers.

Emery, James C↗

Advanced Low-Emissions Catalytic-Combustor Program, phase 1

Six catalytic combustor concepts were defined, analyzed, and evaluated. Major design considerations included low emissions, performance, safety, durability, installations, operations and development. On the basis of these considerations the two most promising concepts were selected. Refined analysis and preliminary design work was conducted on these two concepts. The selected concepts were required to fit within the combustor chamber dimensions of the reference engine. This is achieved by using a dump diffuser discharging into a plenum chamber between the compressor discharge and the turbine inlet, with the combustors overlaying the prediffuser and the rear of the compressor. To enhance maintainability, the outer combustor case for each concept is designed to translate forward for accessibility to the catalytic reactor, liners and high pressure turbine area. The catalytic reactor is self-contained with air-cooled canning on a resilient mounting. Both selected concepts employed integrated engine-starting approaches to raise the catalytic reactor up to operating conditions. Advanced liner schemes are used to minimize required cooling air. The two selected concepts respectively employ fuel-rich initial thermal reaction followed by rapid quench and subsequent fuel-lean catalytic reaction of carbon monoxide, and, fuel-lean thermal reaction of some fuel in a continuously operating pilot combustor with fuel-lean catalytic reaction of remaining fuel in a radially-staged main combustor.

Sturgess, G. J.↗

Small engine components test facility turbine testing cell

NASA Lewis Research Center has designed and constructed a new state-of-the-art test facility. This facility, called the Small Engine Components Test Facility (SECTF), is used to test gas turbines and compressors at conditions similar to actual engine conditions. The SECTF is comprised of two separate facilities - a turbine test cell and a compressor test cell. The paper will describe the turbine test cell. The capabilities of the facility make it unique - no other facility of its kind is capable of combining its pressure, speed, and temperature ranges. Turbine inlet air ranges up to 9 atm (125 psig). The turbine exhaust pressure ranges from 0.15 atm (2 psia) to atmospheric pressure. Turbine inlet air temperatures range from ambient to 700 K (1260 deg R). The controllable speed of the turbine rotor ranges from 4000 to 60,000 rpm and the maximum power absorbed by the facility dynamometer is 1250 hp. The data acquisition system scans up to 2000 channels/sec. This paper will discuss in detail the capabilities of the facility, overall facility design, instrumentation used in the facility, and the data acquisition system. Actual research data is not discussed.

Nowlin, Brent C.↗

Small engine components test facility turbine testing cell

NASA Lewis Research Center has designed and constructed a new state-of-the-art test facility. This facility, called the Small Engine Components Test Facility (SECTF), is used to test gas turbines and compressors at conditions similar to actual engine conditions. The SECTF is comprised of two separate facilities - a turbine test cell and a compressor test cell. The paper will describe the turbine test cell. The capabilities of the facility make it unique - no other facility of its kind is capable of combining its pressure, speed, and temperature ranges. Turbine inlet air ranges up to 9 atm (125 psig). The turbine exhaust pressure ranges from 0.15 atm (2 psia) to atmospheric pressure. Turbine inlet air temperatures range from ambient to 700 K (1260 deg R). The controllable speed of the turbine rotor ranges from 4000 to 60,000 rpm and the maximum power absorbed by the facility dynamometer is 1250 hp. The data acquisition system scans up to 2000 channels/sec. This paper will discuss in detail the capabilities of the facility, overall facility design, instrumentation used in the facility, and the data acquisition system. Actual research data is not discussed.

Nowlin, Brent C.↗

Device for quickly sensing the amount of O2 in a combustion product gas

A sensing device comprising an O2 sensor, a pump, a compressor, and a heater is provided to quickly sense the amount of O2 in a combustion product gas. A sample of the combustion product gas is compressed to a pressure slightly above one atmosphere by the compressor. Next, the heater heats the sample between 800 C and 900 C. Next, the pump causes the sample to be flushed against the electrode located in O2 sensor 6000 to 10,000 times per second. Reference air at approximately one atmosphere is provided to the electrode of O2 sensor. Accordingly, the O2 sensor produces a voltage which is proportional to the amount of oxygen in the combustion product gas. This voltage may be used to control the amount of O2 entering into the combustion chamber which produces the combustion product gas.

Singh, Jag J.↗

Thrust Augmentation of a Turbojet Engine at Simulated Flight Conditions by Introduction of a Water-Alcohol Mixture into the Compressor

An investigation was conducted at simulated high-altitude flight conditions to evaluate the use of compressor evaporative cooling as a means of turbojet-engine thrust augmentation. Comparison of the performance of the engine with water-alcohol injection at the compressor inlet, at the sixth stage of the compressor, and at the sixth and ninth stages was made. From consideration of the thrust increases achieved, the interstage injection of the coolant was considered more desirable preferred over the combined sixth- and ninth-stage injection because of its relative simplicity. A maximum augmented net-thrust ratio of 1.106 and a maximum augmented jet-thrust ratio of 1.062 were obtained at an augmented liquid ratio of 2.98 and an engine-inlet temperature of 80 F. At lower inlet temperatures (-40 to 40 F), the maximum augmented net-thrust ratios ranged from 1.040 to 1.076 and the maximum augmented jet-thrust ratios ranged from 1.027 to 1.048, depending upon the inlet temperature. The relatively small increase in performance at the lower inlet-air temperatures can be partially attributed to the inadequate evaporation of the water-alcohol mixture, but the more significant limitation was believed to be caused by the negative influence of the liquid coolant on engine- component performance. In general, it is concluded that the effectiveness of the injection of a coolant into the compressor as a means of thrust augmentation is considerably influenced by the design characteristics of the components of the engine being used.

Useller, James W.↗

NASA Environmentally Responsible Aviation's Highly-Loaded Front Block Compressor Demonstration

The ERA project was created in 2009 as part of NASAs Aeronautics Research Mission Directorates (ARMD) Integrated Systems Aviation Program (IASP). The purpose of the ERA project was to explore and document the feasibility, benefit, and technical risk of vehicles concepts and enabling technologies to reduce aviations impact on the environment. The metrics for this technology is given in Figure 1 with the N+2 metrics highlighted in green. It is anticipated that the United States air transportation system will continue to expand significantly over the next few decades thus adversely impacting the environment unless new technology is incorporated to simultaneously reduce nitrous oxides (NOx), noise and fuel consumption. In order to achieve the overall goals and meet the technology insertion challenges, these goals were divided into technical challenges that were to be achieved during the execution of the ERA project. Technical challenges were accomplished through test campaigns conducted by Integrated Technology Demonstration (ITDs). ERAs technical performance period ended in 2015.

Environment↗

Venturi Air-Jet Vacuum Ejector For Sampling Air

Venturi air-jet vacuum ejector pump light in weight, requires no electrical power, does not contribute heat to aircraft, and provides high pumping speeds at moderate suctions. High-pressure motive gas required for this type of pump bled from compressor of aircraft engine with negligible effect on performance of engine. Used as source of vacuum for differential-absorption CO-measurement (DACOM), modified to achieve in situ measurements of CO at frequency response of 10 Hz. Provides improvement in spatial resolution and potentially leads to capability to measure turbulent flux of CO by use of eddy-correlation technique.

Hill, Gerald F.↗

Thermoacoustic refrigeration

A new refrigerator which uses resonant high amplitude sound in inert gases to pump heat is described and demonstrated. The phasing of the thermoacoustic cycle is provided by thermal conduction. This 'natural' phasing allows the entire refrigerator to operate with only one moving part (the loudspeaker diaphragm). The thermoacoustic refrigerator has no sliding seals, requires no lubrication, uses only low-tolerance machine parts, and contains no expensive components. Because the compressor moving mass is typically small and the oscillation frequency is high, the small amount of vibration is very easily isolated. This low vibration and lack of sliding seals makes thermoacoustic refrigeration an excellent candidate for food refrigeration and commercial/residential air conditioning applications. The design, fabrication, and performance of the first practical, autonomous thermoacoustic refrigerator, which will be flown on the Space Shuttle (STS-42), are described, and designs for terrestrial applications are presented.

Garrett, Steven L.↗

Oxygen production on Mars and the Moon

Significant progress was made in the area of in-situ oxygen production in the last year. In order to reduce sealing problems due to thermal expansion mismatch in the disk configuration, several all-Zirconia cells were constructed and are being tested. Two of these cells were run successfully for extended periods of time. One was run for over 200 hours and the other for over 800 hours. These extended runs, along with gas sample analysis, showed that the oxygen being produced is definitely from CO2 and not from air leaks or from the disk material. A new tube system is being constructed that is more rugged, portable, durable, and energy efficient. The important operating parameters of this system will be better controlled compared to previous systems. An electrochemical compressor will also be constructed with a similar configuration. The electrochemical compressor will use less energy since the feed stock is already heated in the separation unit. In addition, it does not have moving parts.

Sridhar, K. R.↗

Solid-State Compressor for Space Station Oxygen Recovery

At present, the life support system on the International Space Station Alpha vents overboard the carbon dioxide (CO2) produced by the crew members. Recovering the oxygen contained in the CO2 has the potential to reduce resupply mass by 2000 pounds per year or more, a significant weight that could be used for experimental payloads and other valuable items. The technologies used to remove CO2 from the air and to recover O2 from CO2 are flight-ready; however, the interface between the devices is a problem for the Space Station system. Ames Research Center has developed a new technology that solves the interface issue, possibly allowing closure of the oxygen loop in a spacecraft for the first time. CO2 produced by the crew is removed in the Carbon Dioxide Removal Assembly (CDRA). This device effectively produces a pure CO2 stream, but at a very low pressure. Elsewhere, the oxygen generation system which makes O2 by electrolyzing water produces a hydrogen stream. In principle the CO2 and H2 can react to form methane and water over a suitable catalyst. Water produced in this methane-formation reactor can be returned to the water electrolyzer, where the O2 can be returned to the cabin; however, the methane-formation reactor requires CO2 at a much higher pressure than that produced by the CDRA. Furthermore, the CO2 and H2 are often not available at the same time, due to power management and scheduling on the space station. In order to get the CO2 to the reactor at the right pressure and at the right time, a device or assembly that functions as a vacuum pump, compressor, and storage tank is required.

Finn, John E.↗