Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Advanced Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Aircraft Turbine Engine Control Research at NASA Glenn Research Center

This paper provides an overview of the aircraft turbine engine control research at the NASA Glenn Research Center (GRC). A brief introduction to the engine control problem is first provided with a description of the state-of-the-art control law structure. A historical aspect of engine control development since the 1940s is then provided with a special emphasis on the contributions of GRC. With the increased emphasis on aircraft safety, enhanced performance, and affordability, as well as the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. The Controls and Dynamics Branch (CDB) at GRC is leading and participating in various projects to develop advanced propulsion controls and diagnostics technologies that will help meet the challenging goals of NASA Aeronautics Research Mission programs. The rest of the paper provides an overview of the various CDB technology development activities in aircraft engine control and diagnostics, both current and some accomplished in the recent past. The motivation for each of the research efforts, the research approach, technical challenges, and the key progress to date are summarized.

Garg, Sanjay↗

Aircraft Turbine Engine Control Research at NASA Glenn Research Center

This lecture will provide an overview of the aircraft turbine engine control research at NASA (National Aeronautics and Space Administration) Glenn Research Center (GRC). A brief introduction to the engine control problem is first provided with a description of the current state-of-the-art control law structure. A historical aspect of engine control development since the 1940s is then provided with a special emphasis on the contributions of GRC. The traditional engine control problem has been to provide a means to safely transition the engine from one steady-state operating point to another based on the pilot throttle inputs. With the increased emphasis on aircraft safety, enhanced performance and affordability, and the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. The Controls and Dynamics Branch (CDB) at GRC is leading and participating in various projects in partnership with other organizations within GRC and across NASA, other government agencies, the U.S. aerospace industry, and academia to develop advanced propulsion controls and diagnostics technologies that will help meet the challenging goals of NASA programs under the Aeronautics Research Mission. The second part of the lecture provides an overview of the various CDB technology development activities in aircraft engine control and diagnostics, both current and some accomplished in the recent past. The motivation for each of the research efforts, the research approach, technical challenges and the key progress to date are summarized. The technologies to be discussed include system level engine control concepts, gas path diagnostics, active component control, and distributed engine control architecture. The lecture will end with a futuristic perspective of how the various current technology developments will lead to an Intelligent and Autonomous Propulsion System requiring none to very minimum pilot interface, interfacing directly with the flight management system to determine its mode of operation, and providing personalized engine control to optimize its performance given the current condition and mission objectives.

Propulsion↗

Comparison of temperature adaptive calibration methods for laser induced fluorescence based fuel-in-oil instrument

Fuel dilution of engine oil (or fuel-in-oil, FiO) is an important issue as multiple and late-cycle fuel injection, integral to many combustion efficiency and emissions improvements (e.g., downsized boosted gasoline engines and catalyst thermal management) increases FiO rate. In addition to causing general wear and corrosion in engine due to decreased oil viscosity and pH buffering, FiO is also believed to cause destructive low speed pre-ignition (or super knock) in boosted SI engines. To understand the effects of engine operating conditions on the FiO rate, an optical diagnostic capable of measuring transient FiO on minute timescales was recently developed and demonstrated on a modified GM Ecotech engine system (Neupane et al., Applied Spectroscopy 2021). The measurement is based on adding a dye to the fuel and monitoring for its presence in oil via laser-induced fluorescence (LIF). The measured LIF signal is related to FiO concentration via pre-determined calibration factors using a multivariate classical least square (CLS) method.Since fluorescence quantum yield is a function of temperature, measured LIF intensity not only depends on FiO concentration but also oil temperature. To expand the applicability of the FiO diagnostic to transient oil-temperature conditions (e.g., cold start in practical engines), this study develops a method to account for oil-temperature variations. The effect of oil temperature (20°C - 95°C) on the LIF spectra of eight FiO samples ranging from ~0.8-15% was investigated. LIF intensities of the FiO samples decreased linearly with increasing temperature; the reductions being more significant at dye peaks. We develop a new calibration model (T-adaptive CLS) incorporating the temperature (T) effects on LIF intensity that enables simultaneous calculation of FiO and oil temperature. The improved FiO diagnostic with T-adaptive calibration is more robust, and applicable to varying oil-temperature conditions. For example, when strategies such as multiple/late fuel injections are applied to overcome cold-start instability due to use of low vaporization bio-based fuels such as ethanol, FiO rate is expected to be very high; the improved T-adaptive FiO diagnostic is hence relevant for engine- and fuel-system calibration and optimization. The diagnostic could also provide validation data for flow-field and spray interaction CFD models, further broadening the diagnostic’s utility for advancing engine technology and efficiency.

Neupane, Sneha↗

Methodological Aspects of Shielding and Activation Analyses for ITER Diagnostics Systems - Paper 125

It is expected that the diagnostics systems of the ITER tokamak will provide valuable measurement data about the first in its kind D-T fusion plasma with emission of 14 MeV neutrons. These systems must withstand the neutron and secondary photon radiation along the ITER operation. Under the neutron irradiation the ITER materials are getting radioactive and therefore an adequate shielding must be provided along all the time of ITER operation and shut-down for the reliable machine operation and for the safe personnel access to its components, such as the diagnostics ports. These are the prerequisites for the shielding and activation analysis of the ITER diagnostics systems discussed in this paper. This paper provides insight into the current tasks of neutronics support for the development of ITER diagnostics systems. The tasks themselves range from relatively straightforward ones such as Monte Carlo radiation transport calculations for shielding analyses of the diagnostics systems, to more advanced tasks of Shut-Down Dose Rate (SDDR) analyses for which the dedicated Rigorous 2-Step mesh-based (R2Smesh) and Direct 1-Step (D1S) methodologies were applied. The accuracy and precision of the ITER neutronics analysis is dependent on the methodological approaches and the implying modeling assumptions. In addition to the SDDR challenges, another distinguishing feature of fusion neutronics is a wide use of CAD-based neutronics modeling to design components of fusion devices such as ITER and DEMO. Basically, there are two possibilities of CAD geometry settings in Monte Carlo (MC) radiation transport models, either by the geometry format conversion of CAD models into the format of MC models by means of the interface programs such as McCad and MCAM or by the direct use of CAD geometry engine in MC calculations such as it was realized in the DAGMC code approach. Several conversion interfaces and the DAGMC software library have been tested on the 3D ITER model developed for the CAD-MCNP benchmark. It was concluded that the considered approaches have reached the maturity level to allow their application to real ITER design analyses.

61 RADIATION PROTECTION AND DOSIMETRY↗

Out-of-Pile Testing and Instrumentation Transient Water Irradiation System

Current initiatives to increase the burnup of conventional nuclear fuels past the approximate 62 GWd/t limit have been spurred on by direct savings to refueling and waste storage. The technical justification for a new license limit requires extensive qualification through experimental testing. Unlike beginning-of-life fuels, high-burnup fuels are more susceptible to fuel fragmentation, relocation, and dispersal (FFRD), therefore more data is needed to characterize fuels under key accident scenarios. The Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory has developed a testing apparatus architecture to test fuels and claddings at prototypic conditions. The Transient Water Irradiation System (TWIST) is the latest iteration of a testing device capable of conducting loss of coolant accidents (LOCAs) in TREAT. The Out-of-Pile Testing and Instrumentation TWIST (OPTI-TWIST) is an electrically heated device that is analogous to TWIST. OPTI-TWIST allows for detailed instrumentation and thermal-hydraulic characterization. TWIST ultimately aims to conduct the most advanced in-situ diagnostics to evaluate FFRD in a prototypic LOCA. Moreover, it will explore the phenomenological bifurcation of a decay-energy heat up driven LOCA and a stored-energy heat up driven LOCA. The instrumentation suite includes conventional thermocouples and pressure transducers in addition to an electro impedance sensor, an acoustic emission sensor, an optical pressure sensor, and an optical pyrometer. Characterizing these instruments in OPTI-TWIST eliminates complications of irradiation effects while preserving extreme thermal-hydraulic conditions. Finally, benchmarking both devices to a thermal-hydraulic code like the Reactor Excursion and Leak Analysis Program (RELAP)5-3D provides a unique opportunity for iteration. Pre-test predictions and post-test interpretations inform the physical designs, operational procedures, test conditions, and instrumentation types and positions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

EXTINCTION DROPLET SIZING MEASUREMENTS IN DIESEL RELEVANT SPRAYS

A new diagnostic for the quantification of Sauter Mean Diameter (SMD) in high-pressure fuel sprays has been recently developed using combined optical and x-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination (DBI) imaging, conducted at Georgia Tech, and liquid absorption measurements from x-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the Scattering Absorption Measurement Ratio (SAMR), quantifies two-dimensional distributions of path-integrated SMD, enabling construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial resolution of the corresponding droplet field. The spatially-resolved SMD measurements that result from the SAMR diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine CFD codes. The methodology for quantification of SMD distributions using the SAMR technique has been previously introduced. This thesis aims to extend the initial developmen of SAMR technique by presenting in detail: the experimental methodologies used in the SAMR technique, including the development of an ideal DBI setup for this technique; the data processing methodologies developed by the author; two-dimensional Sauter Mean Diameter measurements within diesel sprays for various experimental conditions; a summary of the various sources of measurement uncertainty; an assessment for how the sources of uncertainty affect the quantified SMD; and paths to improve the technique moving forward. The SMD results show that for low ambient density conditions droplets decrease in size as radial and axial position increases. For high ambient density conditions, however, the droplets show a stable size near the spray centerline and steadily increase in size as distance from the centerline increases. Additionally, this work provides 2-D droplet sizing maps which are particularly useful for model validation.

33 ADVANCED PROPULSION SYSTEMS↗

EXTINCTION DROPLET SIZING MEASUREMENTS IN DIESEL RELEVANT SPRAYS

A new diagnostic for the quantification of Sauter Mean Diameter (SMD) in high-pressure fuel sprays has been recently developed using combined optical and x-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination (DBI) imaging, conducted at Georgia Tech, and liquid absorption measurements from x-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the Scattering Absorption Measurement Ratio (SAMR), quantifies two-dimensional distributions of path-integrated SMD, enabling construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial resolution of the corresponding droplet field. The spatially-resolved SMD measurements that result from the SAMR diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine CFD codes. The methodology for quantification of SMD distributions using the SAMR technique has been previously introduced. This thesis aims to extend the initial development of the SAMR technique by presenting in detail: the experimental methodologies used in the SAMR technique, including the development of an ideal DBI setup for this technique; the data processing methodologies developed by the author; two-dimensional Sauter Mean Diameter measurements within diesel sprays for various experimental conditions; a summary of the various sources of measurement uncertainty; an assessment for how the sources of uncertainty affect the quantified SMD; and paths to improve the technique moving forward. The SMD results show that for low ambient density conditions droplets decrease in size as radial and axial position increases. For high ambient density conditions, however, the droplets show a stable size near the spray centerline and steadily increase in size as distance from the centerline increases. Additionally, this work provides 2-D droplet sizing maps which are particularly useful for model validation.

33 ADVANCED PROPULSION SYSTEMS↗

Fission Yields and Other Diagnostics for Nuclear Performance

I summarize advances in our understanding of basic nuclear physics cross sections and decay properties that are needed to characterize the magnitude and energy-dependence of a neutron flux, and to determine the amount of fission burnup in plutonium fuel. The number of fissions that have occurred in a neutron environment can be deduced from measurements of the fission products created, providing that the fission product yields are known accurately. I describe how our understanding of plutonium fission product yields has improved in recent years through a meta-analysis of various measured data, and through identification of fission product yield incident-energy dependencies over the 0.2-2 MeV fast energy region. This led to the resolution of a previous discrepancy between the Los Alamos and Lawrence Livermore National Laboratories in their plutonium yield assessments in the fast energy region, although more experimental work is still needed to resolve discrepancies at 14 MeV. Work is also described that has improved our understanding of (n,2n) cross sections that are used as diagnostics of the high-energy neutron spectrum – both on plutonium and americium, and on the radiochemical detectors yttrium, iridium, and thulium. Finally, some observations are made on the importance of continuing to develop our Evaluated Nuclear Data Files (ENDF) database using physics insights from differential cross section and integral laboratory experiments and from nuclear theory advances.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser diagnostics for microgravity droplet studies

Rapid advances have recently been made in numerical simulation of droplet combustion under microgravity conditions, while experimental capabilities remain relatively primitive. Calculations can now provide detailed information on mass and energy transport, complex gas-phase chemistry, multi-component molecular diffusion, surface evaporation and heterogeneous reaction, which provides a clearer picture of both quasi-steady as well as dynamic behavior of droplet combustion. Experiments concerning these phenomena typically result in pictures of the burning droplets, and the data therefrom describe droplet surface regression along with flame and soot shell position. With much more precise, detailed, experimental diagnostics, significant gains could be made on the dynamics and flame structural changes which occur during droplet combustion. Since microgravity experiments become increasingly more expensive as they progress from drop towers and flights to spaceborne experiments, there is a great need to maximize the information content from these experiments. Sophisticated measurements using laser diagnostics on individual droplets and combustion phenomena are now possible. These include measuring flow patterns and temperature fields within droplets, vaporization rates and vaporization enhancement, radical species profiling in flames and gas-phase flow-tagging velocimetry. Although these measurements are sophisticated, they have undergone maturation to the degree where with some development, they are applicable to studies of microgravity droplet combustion. This program beginning in September of 1992, will include a series of measurements in the NASA Learjet, KC-135 and Drop Tower facilities for investigating the range of applicability of these diagnostics while generating and providing fundamental data to ongoing NASA research programs in this area. This program is being conducted in collaboration with other microgravity investigators and is aimed toward supplementing their experimental efforts.

Winter, Michael↗

Component and Technology Development for Advanced Liquid Metal Reactors

The following report details the significant developments to Sodium Fast Reactor (SFR) technologies made throughout the course of this funding. This report will begin with an overview of the sodium loop and the improvements made over the course of this research to make it a more advanced and capable facility. These improvements have much to do with oxygen control and diagnostics. Thus a detailed report of advancements with respect to the cold trap, plugging meter, vanadium equilibration loop, and electrochemical oxygen sensor is included. Further analysis of the university’s moving magnet pump was performed and included in a section of this report. A continuous electrical resistance based level sensor was built and tested in the sodium with favorable results. Materials testing was done on diffusion bonded samples of metal and the results are presented here as well. A significant portion of this work went into the development of optical fiber temperature sensors which could be deployed in an SFR environment. Thus, a section of this report presents the work done to develop an encapsulation method for these fibers inside of a stainless steel capillary tube. High temperature testing was then done on the optical fiber ex situ in a furnace. Thermal response time was also explored with the optical fiber temperature sensors. Finally these optical fibers were deployed successfully in a sodium environment for data acquisition. As a test of the sodium deployable optical fiber temperature sensors they were installed in a sub-loop of the sodium facility which was constructed to promote the thermal striping effect in sodium. The optical fibers performed exceptionally well, yielding unprecedented 2 dimensional temperature profiles with good temporal resolution. Finally, this thermal striping loop was used to perform cross correlation velocimetry successfully over a wide range of flow rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Probe diagnostics in the far scrape-off layer plasma of Korea Superconducting Tokamak Advanced Research tokamak using a sideband harmonic method

Plasma characteristics in the far scrape-off layer region of tokamak play a crucial role in the stable plasma operation and its sustainability. Due to the huge facility, electrical diagnostic systems to measure plasma properties have extremely long cable length resulting in large stray current. To overcome this problem, a sideband harmonic method was applied to the Korea Superconducting Tokamak Advanced Research tokamak plasma. The sideband method allows the measurement of the electron temperature and the plasma density without the effect of the stray current. The measured plasma densities are compared with those from the interferometer, and the results show reliability of the method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Pretreatment Combined {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Staging on Radiation Therapy Treatment Decisions in Locally Advanced Breast Cancer

Purpose: To assess the diagnostic performance of pretreatment {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) and its impact on radiation therapy treatment decisions in patients with locally advanced breast cancer (LABC). Methods and Materials: Patients with LABC with Eastern Cooperative Oncology Group performance status <2 and no contraindication to neoadjuvant chemotherapy, surgery, and adjuvant radiation therapy were enrolled on a prospective trial. All patients had pretreatment conventional imaging (CI) performed, including bilateral breast mammography and ultrasound, bone scan, and CT chest, abdomen, and pelvis scans performed. Informed consent was obtained before enrolment. Pretreatment whole-body {sup 18}F-FDG PET/CT scans were performed on all patients, and results were compared with CI findings. Results: A total of 154 patients with LABC with no clinical or radiologic evidence of distant metastases on CI were enrolled. Median age was 49 years (range, 26-70 years). Imaging with PET/CT detected distant metastatic disease and/or locoregional disease not visualized on CI in 32 patients (20.8%). Distant metastatic disease was detected in 17 patients (11.0%): 6 had bony metastases, 5 had intrathoracic metastases (pulmonary/mediastinal), 2 had distant nodal metastases, 2 had liver metastases, 1 had pulmonary and bony metastases, and 1 had mediastinal and distant nodal metastases. Of the remaining 139 patients, nodal disease outside conventional radiation therapy fields was detected on PET/CT in 15 patients (10.8%), with involvement of ipsilateral internal mammary nodes in 13 and ipsilateral level 5 cervical nodes in 2. Conclusions: Imaging with PET/CT provides superior diagnostic and staging information in patients with LABC compared with CI, which has significant therapeutic implications with respect to radiation therapy management. Imaging with PET/CT should be considered in all patients undergoing primary staging for LABC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CSTI High Capacity Power

The SP-100 program was established in 1983 by DOD, DOE, and NASA as a joint program to develop the technology necessary for space nuclear power systems for military and civil application. During FY-86 and 87, the NASA SP-100 Advanced Technology Program was devised to maintain the momentum of promising technology advancement efforts started during Phase 1 of SP-100 and to strengthen, in key areas, the chances for successful development and growth capability of space nuclear reactor power systems for future space applications. In FY-88, the Advanced Technology Program was incorporated into NASA's new Civil Space Technology Initiative (CSTI). The CSTI Program was established to provide the foundation for technology development in automation and robotics, information, propulsion, and power. The CSTI High Capacity Power Program builds on the technology efforts of the SP-100 program, incorporates the previous NASA SP-100 Advanced Technology project, and provides a bridge to NASA Project Pathfinder. The elements of CSTI High Capacity Power development include Conversion Systems, Thermal Management, Power Management, System Diagnostics, and Environmental Interactions. Technology advancement in all areas, including materials, is required to assure the high reliability and 7 to 10 year lifetime demanded for future space nuclear power systems. The overall program will develop and demonstrate the technology base required to provide a wide range of modular power systems as well as allowing mission independence from solar and orbital attitude requirements. Several recent advancements in CSTI High Capacity power development will be discussed.

Winter, Jerry M.↗

CSTI high capacity power

In FY-88, the Advanced Technology Program was incorporated into NASA's Civil Space Technology Initiative (CSTI). The CSTI Program was established to provide the foundation for technology development in automation and robotics, information, propulsion, and power. The CSTI High Capacity Power Program builds on the technology efforts of the SP-100 program, incorporates the previous NASA SP-100 Advanced Technology project, and provides a bridge to NASA Project Pathfinder. The elements of CSTI High Capacity Power development include Converrsion Systems, Thermal Management, Power Management, System Diagnostics, and Environmental Interactions. Technology advancement in all areas, including materials, is required to assure the high reliability and 7 to 10 year lifetime demanded for future space nuclear power systems.

Winter, Jerry M.↗

Measurement of Sauter mean diameter in diesel sprays using a scattering–absorption measurement ratio technique

A new diagnostic for the quantification of Sauter mean diameter in high-pressure fuel sprays has been recently developed using combined optical and X-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination imaging, conducted at Georgia Tech, and liquid absorption measurements from X-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the scattering–absorption measurement ratio, quantifies two-dimensional distributions of path-integrated Sauter mean diameter, enabling the construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial resolution of the corresponding droplet field. The methodology for quantification of Sauter mean diameter distributions using the scattering–absorption measurement ratio technique has been previously introduced and demonstrated in diesel sprays using the Engine Combustion Network Spray D injector; however, a more detailed treatment of measurement uncertainties has been needed. In this work, we present a summary of the various sources of measurement uncertainty in the scattering–absorption measurement ratio diagnostic, like those due to the experimental setup, data processing methods, and theoretical assumptions, and assess how these sources of uncertainty affect the quantified Sauter mean diameter. The spatially resolved Sauter mean diameter measurements that result from the scattering–absorption measurement ratio diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine computational fluid dynamics codes. Careful evaluation and quantification of measurement uncertainties are important to support accurate model validation and to ensure the development of more predictive spray models.

42 ENGINEERING↗

A new dump system design for stray light reduction of Thomson scattering diagnostic system on EAST

Thomson scattering (TS) diagnostic is an important diagnostic for measuring electron temperature and density during plasma discharge. However, the measurement of Thomson scattering signal is disturbed by the stray light easily. The stray light sources in the Experimental Advanced Superconducting Tokamak (EAST) TS diagnostic system were analyzed by a simulation model of the diagnostic system, and simulation results show that the dump system is the primary stray light source. Based on the optics theory and the simulation analysis, a novel dump system including an improved beam trap was proposed and installed. The measurement results indicate that the new dump system can reduce more than 60% of the stray light for the diagnostic system, and the influence of stray light on the error of measured density decreases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray power and yield measurements at the refurbished Z machine

Advancements have been made in the diagnostic techniques to measure accurately the total radiated x-ray yield and power from z-pinch implosion experiments at the Z machine with high accuracy. The Z machine is capable of outputting 2 MJ and 330 TW of x-ray yield and power, and accurately measuring these quantities is imperative. We will describe work over the past several years which include the development of new diagnostics, improvements to existing diagnostics, and implementation of automated data analysis routines. A set of experiments on the Z machine were conducted in which the load and machine configuration were held constant. During this shot series, it was observed that the total z-pinch x-ray emission power determined from the two common techniques for inferring the x-ray power, a Kimfol filtered x-ray diode diagnostic and the total power and energy diagnostic, gave 449 TW and 323 TW, respectively. Our analysis shows the latter to be the more accurate interpretation. More broadly, the comparison demonstrates the necessity to consider spectral response and field of view when inferring x-ray powers from z-pinch sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗