Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Advanced Detector Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Blocked impurity band hybrid infrared focal plane arrays for astronomy

High-performance infrared hybrid focal plane arrays using 10- x 50-element Si:As blocked-impurity-band (BIB) detectors (cutoff wavelength = 28 microns) and matching switched MOSFET multiplexers have been developed and characterized for space astronomy. Use of impurity-band-conduction technology provides detectors which are nuclear-radiation-hard and free of the many anomalies associated with conventional silicon photoconductive detectors. Emphasis in the present work is on recent advances in detector material quality which have led to significantly improved detector and hybrid characteristics. Results demonstrating increased quantum efficiency (particularly at short-wavelength infrared), obtained by varying the BIB detector properties (infrared active layer thickness and arsenic doping profile), are summarized. Measured read noise and dark current for different temperatures are reported. The hybrid array performance achieved demonstrates that BIB detectors are well suited for use in astronomical instrumentation.

Reynolds, D. B.↗

The AXAF/XRS test dewar - A versatile design

The X-Ray Spectrometer (XRS) to be flown on the Advanced X-ray Astrophysics Facility (AXAF) consists of an array of microcalorimeters and an Adiabatic Demagnetization Refrigerator (ADR). The ADR provides an operating temperature of 0.065 to 0.100 K. To support extensive development testing of the ADR and the detector array, a test dewar has been designed and built that surpasses specification requirements. Pumping on the liquid helium bath with a 47 l/s pump, we have achieved temperatures lower than 1.5 K with a hold time in excess of 72 hrs. The dewar can be operated without liquid nitrogen with a hold time of 36 hrs. This feature was incorporated in the design because boiling nitrogen may introduce microphonic noise to the detectors. To further reduce the susceptibility to microphonic vibration a unique suspension system utilizing Kevlar fibers was devised which provides both translational and rotational rigidity to the detector mount. Finally, the dewar is very manageable and may be rotated by only one person.

Weintz, Karl F.↗

Preliminary Results from the First Flight of ATIC: The Silicon Matrix

The Advanced Thin Ionization Calorimeter (ATIC) uses a silicon matrix detector to determine charge in conjunction with a scintillator hodoscope that measures charge and trajectory. Cosmic rays that interact in a carbon target have their energy determined from the shower that develops within a fully active calorimeter composed of a stack of scintillating BGO crystals. The silicon matrix consists of 4480 individual silicon pads, each capable of measuring the signal from cosmic rays with atomic numbers from 1 to 26. Preliminary results will be presented describing the performance of the silicon matrix during the 16-day maiden flight of ATIC around Antarctica.

Adams, J. H., Jr.↗

Preliminary Results From the First Flight of ATIC: The Silicon Matrix

The Advanced Thin Ionization Calorimeter (ATIC) uses a silicon matrix detector in conjunction with a scintillator hodoscope to determine the incident cosmic ray's charge. Cosmic rays that interact in a carbon target have their energy determined from the shower that develops within a fully active calorimeter composed of a stack of scintillating BGO crystals. The silicon matrix consists of 4480 individual silicon pads, each capable of measuring the signal from cosmic rays with atomic numbers from I to 26. Preliminary results will be presented describing the performance of the silicon matrix during the 16-day maiden flight of ATIC around Antarctica.

Adams, James H., Jr.↗

Photonic Integrated Circuits

Integrated photonics generally is the integration of multiple lithographically defined photonic and electronic components and devices (e.g. lasers, detectors, waveguides passive structures, modulators, electronic control and optical interconnects) on a single platform with nanometer-scale feature sizes. The development of photonic integrated circuits permits size, weight, power and cost reductions for spacecraft microprocessors, optical communication, processor buses, advanced data processing, and integrated optic science instrument optical systems, subsystems and components. This is particularly critical for small spacecraft platforms. We will give an overview of some NASA applications for integrated photonics.

Laser↗

Photonic Integrated Circuits

Integrated photonics generally is the integration of multiple lithographically defined photonic and electronic components and devices (e.g. lasers, detectors, waveguides passive structures, modulators, electronic control and optical interconnects) on a single platform with nanometer-scale feature sizes. The development of photonic integrated circuits permits size, weight, power and cost reductions for spacecraft microprocessors, optical communication, processor buses, advanced data processing, and integrated optic science instrument optical systems, subsystems and components. This is particularly critical for small spacecraft platforms. We will give an overview of some NASA applications for integrated photonics.

laser↗

Large area sheet task. Advanced dendritic web growth development

The development of a silicon dendritic web growth machine is discussed. Several refinements to the sensing and control equipment for melt replenishment during web growth are described and several areas for cost reduction in the components of the prototype automated web growth furnace are identified. A circuit designed to eliminate the sensitivity of the detector signal to the intensity of the reflected laser beam used to measure melt level is also described. A variable speed motor for the silicon feeder is discussed which allows pellet feeding to be accomplished at a rate programmed to match exactly the silicon removed by web growth.

Duncan, C. S.↗

Handheld readout electronics to fully exploit the particle discrimination capabilities of elpasolite scintillators

In this study, a new class of elpasolite scintillators has garnered recent attention due to the ability to perform as simultaneous gamma spectrometers and thermal neutron detectors. Such a dual-mode capability is made possible by pulse-shape discrimination (PSD), whereby the emission waveform profiles of gamma and neutron events are fundamentally unique. To take full advantage of these materials, we have developed the Compact Advanced Readout Electronics for Elpasolites (CAREE). This handheld instrument employs a multi-channel PSD-capable ASIC, custom micro-processor board, front-end electronics, power supplies, and a 2 in. photomultiplier tube for readout of the scintillator. The unit is highly configurable to allow for performance optimization amongst a wide sample of elpasolites which provide PSD in fundamentally different ways. We herein provide an introduction to elpasolites, then describe the motivation for the work, mechanical and electronic design, and preliminary performance results.

42 ENGINEERING↗

LDR system concepts and technology

The Large Deployable Reflector is a 20 meter diameter infrared/submillimeter telescope planned for the late 1990's. The Astronomy Survey Committee of the National Academy of Sciences (Field Committee) recommended LDR as one of the two space based observatories that should start development in the 80's. LDR's large aperture will give it unequaled resolution in the wavelength range from 30 to 1000 microns. To meet LDR performance goals will call for advances in several technology disciplines including: optics, controls, thermal control, detectors, cryogenic cooling, and large space structures.

Pittman, B.↗

Advances in imaging instrumentation for nuclear cardiology

Advances in imaging instrumentation and technology have greatly contributed to nuclear cardiology. Dedicated cardiac SPECT cameras incorporating novel, highly efficient detector, collimator, and system designs have emerged with the expansion of nuclear cardiology. Solid-state radiation detectors incorporating cadmium zinc telluride, which directly convert radiation to electrical signals and yield improved energy resolution and spatial resolution and enhanced count sensitivity geometries, are increasingly gaining favor as the detector of choice for application in dedicated cardiac SPECT systems. Additionally, hybrid imaging systems in which SPECT and PET are combined with X-ray CT are currently widely used, with PET/MRI hybrid systems having also been recently introduced. The improved quantitative SPECT/CT has the potential to measure the absolute quantification of myocardial blood flow and flow reserve. Rapid development of silicon photomultipliers leads to enhancement in PET image quality and count rates. In addition, the reduction of emission–transmission mismatch artifacts via application of accurate time-of-flight information, and cardiac motion de-blurring aided by anatomical images, are emerging techniques for further improvement of cardiac PET. This article reviews recent advances such as these in nuclear cardiology imaging instrumentation and technology, and the corresponding diagnostic benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlinear Signal Processing for Removing Microphonic Noise from Nuclear Spectrometer Measurements: Sparse Linear Modeling via L1 Norm Regularization [Slides]

The focus of this initial work is to apply recent breakthroughs in sparse linear modeling and nonlinear signal processing to the problem of removing microphonic noise from nuclear spectrum measurements. The resolution of nuclear spectrum measurements is commonly degraded by microphonic noise caused by the vibration of supporting equipment (i.e. cryocoolers) as well as motion of the detector itself in mobile applications. Current signal processing techniques cannot remove microphonic noise without modifying the desired characteristics of the spikes induced by nuclear detection events. The LANL Engineering Institute has been working with NEN‐1 to remedy this problem. Initial work focused on developing active control systems to cancel the vibrations experienced by nuclear detectors. As work on progressed along these lines the team realized that a more robust, lower‐energy, lower‐cost solution to the microphonic noise problem could be realized using recent breakthroughs in nonlinear signal processing. Over the course of the last decade significant advances have been made in the field of sparse linear modeling using L1 norm minimization to find linear representations of sparse signals. The problem of removing microphonic noise from nuclear detection measurements appears to be well suited to the L1 minimization approach because these measurements tend to be inherently sparse in two different domains. The nuclear detections are sparse in a spike domain, and the microphonic noise is sparse in the Fourier basis. L1 minimization allows us to decompose the measurements into these two domains. The result is that we can potentially separate the spikes from the microphonic noise. Initial investigations into this technique look very promising. In this work microphonic noise is induced in an HE‐3 detector by a wrench impact. A pulser is used to generate uniform, synthetic, nuclear events and is fed into the detector front end electronics. Nearly all the microphonic noise is separated from the spike measurements. The histograms in Figure 2 illustrate that spectrum widening caused by noise is significantly reduced. The goal of future work to further develop this technique to account for variations in spike characteristics, as well as to use adaptive signal processing and modern Graphical Processing Unit (GPU) technology to speed up the signal decompositions.

42 ENGINEERING↗

A linear collider vision for the future of particle physics

In this paper we review the physics opportunities at linear e + e - colliders with a special focus on high centre-of-mass energies and beam polarisation, take a fresh look at the various accelerator technologies available or under development and, for the first time, discuss how a facility first equipped with a technology that is mature today could be upgraded with technologies of tomorrow to reach much higher energies and/or luminosities. In addition, we discuss detectors, alternative collider modes, as well as opportunities for beyond-collider experiments and R&D facilities as part of a linear collider facility (LCF). The material of this paper supports all plans for e + e - linear colliders and the additional opportunities they offer, independently of technology choice or proposed site, as well as R&D for advanced accelerator technologies. This joint perspective on the physics goals, early technologies and upgrade strategies has been developed by the LCVision team based on an initial discussion at LCWS2024 in Tokyo and a follow-up at the LCVision Community Event at CERN in January 2025. It heavily builds on decades of achievements of the global linear collider community, in particular in the context of CLIC and ILC.

43 PARTICLE ACCELERATORS↗

Development of a multidimensional gamma-spectrometer

A high-sensitivity multidimensional gamma-spectrometer is being developed within the shallow underground laboratory at Pacific Northwest National Laboratory (PNNL, USA). The system consists of two Broad Energy Germanium (BEGe) detectors, inside a low-background lead and copper shield, fitted with a cosmic veto background reduction system. The detector has advanced functionality, including operation in single or combined detector mode, with reductions in the cosmic background by 49.6% and Compton suppression of 6.5%. For selected radionuclides this provides an overall MDA improvement of 52.7%. Utilizing both detectors for simultaneous measurements of thermally irradiated highly enriched uranium (HEU) increased peak identification and reduced uncertainty by 27.6%. The design uses commercially off-the-shelf (COTS) components, for which the configuration is described, to provide a practical and powerful solution for low-level nuclear measurements.

Compton suppression↗

X-Ray Phase Contrast Imaging (XPCI) System

Sandia National Laboratories (Sandia) and Carestream Health, Inc. (CHI) collaborated on the development of a grating-based X-ray Phase Contrast Imaging (XPCI) system at Sandia. The purpose of the agreement was to share research and development knowledge, resources, and capabilities in the advancement of XPCI that would be mutually beneficial to CHI and Sandia. In the course of this agreement Sandia designed and built an XPCI apparatus including opto-mechanical design, source and x-ray detector selection, software interface, hardware assembly, and system alignment. Data acquisition and image reconstruction were demonstrated at both CHI and Sandia. XPCI is a new imaging modality that enables non-destructive inspection of low density materials not previously possible with conventional x-ray. The technique fills a capability gap valuable to both the industry partner in their technical portfolio and in national security applications important to Sandia and the DOE mission space.

47 OTHER INSTRUMENTATION↗

A Paris-Edinburgh Cell for High-Pressure and High-Temperature Structure Studies on Silicate Liquids Using Monochromatic Synchrotron Radiation

A Paris-Edinburgh press combined with a multi-channel collimator assembly has been commissioned at the GeoSoilEnviro Center for Advanced Radiation Sources (GSECARS) beamline for monochromatic X-ray scattering, with an emphasis on studying low-Z liquids, especially silicate liquids at high pressure. The Paris-Edinburgh press is mounted on a general-purpose diffractometer, with a pixel array detector mounted on the detector arm. The incident monochromatic undulator beam with energies up to 60 keV is focused both horizontally and vertically to a beam size about 30 × 30 µm. With this setup, background scattering from the surrounding pressure media is completely removed at 2θ angles above 10° for samples larger than 1.05 mm in diameter. Thirty minutes is typically sufficient to collect robust X-ray scattering signals from a 1.6 mm diameter amorphous silicate sample. Cell assemblies for the standard Paris-Edinburgh anvils have been developed and pressures and temperatures up to 7 GPa and 2300 K, respectively, have been maintained steadily over hours. We have also developed a cupped-toroidal Drickamer anvil to further increase pressure and temperature capabilities. The cupped-toroidal Drickamer anvil combines features of a modified Drickamer anvil and the traditional Paris-Edinburgh anvil. Pressures up to 12 GPa have been generated at temperatures up to 2100 K.

58 GEOSCIENCES↗

Identifying, studying and making good use of macromolecular crystals

As technology advances, the crystal volume that can be used to collect useful X-ray diffraction data decreases. The technologies available to detect and study growing crystals beyond the optical resolution limit and methods to successfully place the crystal into the X-ray beam are discussed. Structural biology has contributed tremendous knowledge to the understanding of life on the molecular scale. The Protein Data Bank, a depository of this structural knowledge, currently contains over 100 000 protein structures, with the majority stemming from X-ray crystallography. As the name might suggest, crystallography requires crystals. As detectors become more sensitive and X-ray sources more intense, the notion of a crystal is gradually changing from one large enough to embellish expensive jewellery to objects that have external dimensions of the order of the wavelength of visible light. Identifying these crystals is a prerequisite to their study. This paper discusses developments in identifying these crystals during crystallization screening and distinguishing them from other potential outcomes. The practical aspects of ensuring that once a crystal is identified it can then be positioned in the X-ray beam for data collection are also addressed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Chemochromic Hydrogen Leak Detectors

At NASA, hydrogen safety is a key concern for space shuttle processing. Leaks of any level must be quickly recognized and addressed due to hydrogen s lower explosion limit. Chemo - chromic devices have been developed to detect hydrogen gas in several embodiments. Because hydrogen is odorless and colorless and poses an explosion hazard, there is an emerging need for sensors to quickly and accurately detect low levels of leaking hydrogen in fuel cells and other advanced energy- generating systems in which hydrogen is used as fuel. The device incorporates a chemo - chromic pigment into a base polymer. The article can reversibly or irreversibly change color upon exposure to hydrogen. The irreversible pigment changes color from a light beige to a dark gray. The sensitivity of the pigment can be tailored to its application by altering its exposure to gas through the incorporation of one or more additives or polymer matrix. Furthermore, through the incorporation of insulating additives, the chemochromic sensor can operate at cryogenic temperatures as low as 78 K. A chemochromic detector of this type can be manufactured into any feasible polymer part including injection molded plastic parts, fiber-spun textiles, or extruded tapes. The detectors are simple, inexpensive, portable, and do not require an external power source. The chemochromic detectors were installed and removed easily at the KSC launch pad without need for special expertise. These detectors may require an external monitor such as the human eye, camera, or electronic detector; however, they could be left in place, unmonitored, and examined later for color change to determine whether there had been exposure to hydrogen. In one type of envisioned application, chemochromic detectors would be fabricated as outer layers (e.g., casings or coatings) on high-pressure hydrogen storage tanks and other components of hydrogen-handling systems to provide visible indications of hydrogen leaks caused by fatigue failures or other failures in those systems. In another type of envisioned application, chemochromic detectors of this type could be optoelectronically instrumented for monitoring to provide measured digital indications of color changes indicative of the presence of hydrogen.

Roberson, Luke↗

Reducing Radiation Damage Using Pulsed Electron Beams in the TEM

A rise in the development and the use of ultrashort-pulsed sources (i.e., femtosecond to picosecond) in transmission electron microscopes (TEMs) has led to numerous discoveries and paradigm tests of atomic to nanoscale structural dynamics well beyond the temporal limits of fast detectors. Vital to these advances are precise control over the electron emission process, typically via the photoelectric effect, or via temporal modulation of an initially continuous beam swept across an aperture. In addition to enabling ultrafast pump-probe experiments, fine control over the emission process allows for exploration of the effects of such pulsed beams on damage sustained by the specimen during observation. Unlike proposed diffract-before-destroy methods with electrons, these approaches would ideally be applied in the single-electron-per-packet regime, with sufficient time between the arrival of each electron at the specimen for all reversible energy-deposition events to fully recover. Indeed, some intriguing results using pulsed electron beams in TEMs have been reported here, including effects on the structure of catalyst particles and apparent prolonged exposures for polymer crystals

61 RADIATION PROTECTION AND DOSIMETRY↗