Exploring improved simulation techniques for analysis and design of auto-magnetizing liner experiments.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Nuclear Power Plant (NPP) operating procedure is “a set of rules that describes how actions on the plant should be made if a certain system goal should be accomplished. U.S. NPPs use paper-based procedures (PBPs). PBPs are difficult to use. Common errors with PBPs are: following the wrong procedure, omit a step etc. Computer based procedures (CPBs) offer great improvement in ensuring plant safety. Some studies rely on experienced operators to understand the procedure content and then reorganize the procedure with digitally executable capabilities. Other studies utilize the procedure format to design rules to extract information from the operating procedures. Existing studies in procedure parsing are manual, laborious and extract limited information. This study aims to automatically extract critical information from operating procedures for generating computer interpretable representation of procedures. Such representation can further be used for automatic dynamic human reliability analysis and CPB design etc.
Abstract not provided.
Explore the source record for details and available documents.
Ultrafast nanocrystallography has the potential to revolutionize biology by enabling structural elucidation of proteins for which it is possible to grow crystals with 10 or fewer unit cells. The success of nanocrystallography depends on robust orientation-determination procedures that allow us to average diffraction data from multiple nanocrystals to produce a 3D diffraction data volume with a high signal-to-noise ratio. Such a 3D diffraction volume can then be phased using standard crystallographic techniques."Indexing" algorithms used in crystallography enable orientation determination of a diffraction data from a single crystal when a relatively large number of reflections are recorded. Here we show that it is possible to obtain the exact lattice geometry from a smaller number of measurements than standard approaches using a basis pursuit solver.
Automated demand response (Auto-DR) is expected to close the loop between buildings and the grid by providing machine-to-machine communications to curtail loads without the need for human intervention. Hence, it can offer more reliable and repeatable demand response results to the grid than the manual approach and make demand response participation a hassle-free experience for customers. However, many building operators misunderstand Auto-DR and are afraid of losing control over their building operation. To ease the transition from manual to Auto-DR, we designed and implemented granular control of Auto-DR systems so that building operators could modify or opt out of individual load-shed strategies whenever they wanted. This paper reports the research findings from this effort demonstrated through a field study in large commercial buildings located in New York City. We focused on (1) understanding how providing granular control affects building operators’ perspective on Auto-DR, and (2) evaluating the usefulness of granular control by examining their interaction with the Auto-DR user interface during test events. Through trend log analysis, interviews, and surveys, we found that: (1) the opt-out capability during Auto-DR events can remove the feeling of being forced into load curtailments and increase their willingness to adopt Auto-DR; (2) being able to modify individual load-shed strategies allows flexible Auto-DR participation that meets the building’s changing operational requirements; (3) a clear display of automation strategies helps building operators easily identify how Auto-DR is functioning and can build trust in Auto-DR systems.
Purpose: To compare the quality of volumetric modulated arc therapy (VMAT) or intensity-modulated radiation therapy (IMRT) plans generated by an automated inverse planning system with that of dosimetrist-generated IMRT treatment plans for patients with stage III lung cancer. Methods and Materials: Two groups of 8 patients with stage III lung cancer were randomly selected. For group 1, the dosimetrists spent their best effort in designing IMRT plans to compete with the automated inverse planning system (mdaccAutoPlan); for group 2, the dosimetrists were not in competition and spent their regular effort. Five experienced radiation oncologists independently blind-reviewed and ranked the three plans for each patient: a rank of 1 was the best and 3 was the worst. Dosimetric measures were also performed to quantitatively evaluate the three types of plans. Results: Blind rankings from different oncologists were generally consistent. For group 1, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.6, 2.13, and 2.18, respectively. The auto-VMAT plans in group 1 had 10% higher planning tumor volume (PTV) conformality and 24% lower esophagus V70 (the volume receiving 70 Gy or more) than the manual IMRT plans; they also resulted in more than 20% higher complication-free tumor control probability (P+) than either type of IMRT plans. The auto- and manual IMRT plans in this group yielded generally comparable dosimetric measures. For group 2, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.55, 1.75, and 2.75, respectively. Compared to the manual IMRT plans in this group, the auto-VMAT plans and auto-IMRT plans showed, respectively, 17% and 14% higher PTV dose conformality, 8% and 17% lower mean lung dose, 17% and 26% lower mean heart dose, and 36% and 23% higher P+. Conclusions: mdaccAutoPlan is capable of generating high-quality VMAT and IMRT treatment plans for stage III lung cancer. Manual IMRT plans could achieve quality similar to auto-IMRT plans if best effort was spent.
Recent developments in Radiation Oncology treatment planning have led to the development of software packages that facilitate automated intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning. Such solutions include site-specific modules, plan library methods, and algorithm-based methods. In this study, the plan quality for prostate cancer generated by the Auto-Planning module of the Pinnacle{sup 3} radiation therapy treatment planning system (v9.10, Fitchburg, WI) is retrospectively evaluated. The Auto-Planning module of Pinnacle{sup 3} uses a progressive optimization algorithm. Twenty-three prostate cancer cases, which had previously been planned and treated without lymph node irradiation, were replanned using the Auto-Planning module. Dose distributions were statistically compared with those of manual planning by the paired t-test at 5% significance level. Auto-Planning was performed without any manual intervention. Planning target volume (PTV) dose and dose to rectum were comparable between Auto-Planning and manual planning. The former, however, significantly reduced the dose to the bladder and femurs. Regression analysis was performed to examine the correlation between volume overlap between bladder and PTV divided by the total bladder volume and resultant V70. The findings showed that manual planning typically exhibits a logistic way for dose constraint, whereas Auto-Planning shows a more linear tendency. By calculating the Akaike information criterion (AIC) to validate the statistical model, a reduction of interoperator variation in Auto-Planning was shown. We showed that, for prostate cancer, the Auto-Planning module provided plans that are better than or comparable with those of manual planning. By comparing our results with those previously reported for head and neck cancer treatment, we recommend the homogeneous plan quality generated by the Auto-Planning module, which exhibits less dependence on anatomic complexity.
Purpose: Recently an ultrafast automatic planning system for breast irradiation using tangential beams was developed by modeling relationships between patient anatomy and achieved dose distribution. This study evaluates the performance of this system when applied to a different patient population and dose calculation algorithm. Methods: The system and its anatomy-to-dose models was developed at institution A based on 20 cases, which were planned using manual fluence painting technique and calculated WITH heterogeneity correction. Institution B uses field-in-field planning technique and dose calculation WITHOUT heterogeneity correction. 11 breast cases treated at Institution B were randomly selected for retrospective study, including left and right sides, and different breast size (irradiated volumes defined by Jaw/MLC opening range from 875cc to 3516cc). Comparisons between plans generated automatically (Auto-Plans) and those used for treatment (Clinical-Plans) included: energy choice (single/mixed), volumes receiving 95%/100%/105%/110% Rx dose (V95%/V100%/V105%/V100%) relative to irradiated volume, D1cc, and LungV20Gy. Results: In 9 out of 11 cases single/mixed energy choice made by the software agreed with Clinical-Plans. For the remaining 2 cases software recommended using mixed energy and dosimetric improvements were observed. V100% were similar (p=0.223, Wilcoxon Signed-Rank test) between Auto-Plans and Clinical-Plans (57.6±8.9% vs. 54.8±9.5%). V95% is 2.3±3.0% higher for Auto-Plans (p=0.027), indicating reduced cold areas. Hot spot volume V105% were significantly reduced in Auto-Plan by 14.4±7.2% (p=0.004). Absolute V105% was reduced from 395.6±359.9cc for Clinical-Plans to 108.7±163cc for Auto-Plans. D1cc was 107.4±2.8% for Auto-Plans, and 109.2±2.4% for Clinical-Plans (p=0.056). LungV20Gy were 13.6±4.0% for Auto-Plan vs. 14.0±4.1% for Clinical-Plans (p=0.043). All optimizations were finished within 1.5min. Conclusion: The performance of this breast auto-planning system remained stable and satisfactory when applied to a different patient population and dose calculation algorithm. The auto-planning system was able to produce clinically similar Rx dose coverage with significantly improved homogeneity inside breast tissue, in less than 1.5min.
The auto industry is one of the largest and most important sectors of the U;S. economy. At the time of the CRADA, the Big Three U.S. auto makers (Chrysler, Ford and GM) alone employed··608,000 workers·in this country and marketed some eight million new cars and trucks worth approximately $200 billion in sales revenues. When the impact of part suppliers, steel, aluminum, and electronics producers were included, the effect of a downturn in U.S. car manufacturing had a nationwide impact on jobs and the economy. For example, U.S. auto makers used 1/7 of all U.S. steel production and 1/6 of all U.S. aluminum production. Transplant Japanese factories cannot be expected to compensate for reductions by U.S. auto makers; in fact, transplants resulted in a net loss of U.S. jobs. In 1991, the Big Three U.S. auto makers sold 8.8 million new cars and trucks with over 620,000 employees while the Big Three Japanese firms (Toyota, Nissan, and Honda) sold 2.4 million new cars and trucks with only 37,000 U.S. employees. It was estimated that the Japanese owned, U.S.-located, auto assembly facilities enjoyed an $8-$9 an hour labor cost advantage over the U.S. Big Three by building new plants in rural areas and hiring young workers with smaller health care and pension needs. Most of the parts in the 2.4 million cars and trucks sold by Japanese auto makers come directly from Japan and the engineering activities were mostly performed in Japan before U.S. assembly began. The effect of these issues was reflected in the U.S. Japan trade imbalance; about two-thirds of Japan's trade surplus was attributable to autos and auto parts.
Auto-oscillations of magnetization driven by direct spin current have been previously observed in multiple quasi-zero-dimensional (0D) ferromagnetic systems such as nanomagnets and nanocontacts. Recently, it was shown that pure spin Hall current can excite coherent auto-oscillatory dynamics in quasi-one-dimensional (1D) ferromagnetic nanowires but not in quasi-two-dimensional (2D) ferromagnetic films. Here we study the 1D to 2D dimensional crossover of current-driven magnetization dynamics in wire-based Pt/Ni 80 Fe 20 bilayer spin Hall oscillators via varying the wire width. We find that increasing the wire width results in an increase of the number of excited auto-oscillatory modes accompanied by a decrease of the amplitude and coherence of each mode. We also observe a crossover from a hard to a soft onset of the auto-oscillations with increasing wire width. The amplitude of auto-oscillations rapidly decreases with increasing temperature suggesting that interactions of the phase-coherent auto-oscillatory modes with incoherent thermal magnons play an important role in suppression of the auto-oscillatory dynamics. Our measurements in this work set the upper limit on the dimensions of an individual spin Hall oscillator and elucidate the mechanisms leading to suppression of coherent auto-oscillations with increasing oscillator size.
In this paper we examine several display and automation considerations of a collision avoidance system that is currently under development: the Airborne Collision Avoidance System (ACAS) Xu. This study builds on previous work conducted as part of NASA’s Unmanned Aircraft Systems (UAS) Integration into the National Airspace System (NAS) project. ACAS Xu represents the next-generation successor to the Traffic Alert and Collision Avoidance System (TCAS II), wherein the Xu variant is intended for UAS applications. Whereas TCAS II exclusively issues RAs in the vertical dimension, a major distinction between ACAS Xu and previous collision avoidance (CA) systems is the introduction of horizontal and “blended” RAs (i.e., RAs with both horizontal and vertical components). This present work was conducted as an engineering analysis involving two parts. In Part 1, a two-by-two, within-subjects study was performed that manipulated how RAs were presented to a pilot situated at a UAS ground control station. Five participants experienced four experimental trials in which text and aural alerting characteristics were manipulated. In Part 2, another five participants experienced four trials in which the levels of automation were manipulated with regard to the CA and return-to-course (RTC) tasks. The results for Part 1 found no effect of display or alerting configuration on pilot performance. However, it was discovered that pilot response time to RAs greatly depended on the RA type. In particular, pilots were quicker to respond to vertical RAs (M = 4.52 seconds) than horizontal (M = 7.42 seconds) and blended (M = 9.68 seconds) RAs in which both dimensions were issued simultaneously. For Part 2 of the study, pilots found both auto-CA and auto-RTC functions equally useful. Most pilots were comfortable with the automation, however responses were mixed. Three of five participants indicated high levels of comfort with the auto-CA function, while two rated their comfort as low. Pilots’ comfort for the auto-RTC functionality was slightly higher: four out of five pilots gave high ratings, while one pilot gave a low rating. Overall, pilots ordinally ranked their preference for automated functions as auto-CA together with auto-RTC (when an aural alert announces a change between CA and RTC states), auto-CA, and auto-CA and RTC (without the aural state-change announcement). Recommendations for improving the display of automation are also discussed.
In this presentation we examine several display and automation considerations of a collision avoidance system that is currently under development: the Airborne Collision Avoidance System (ACAS) Xu. This study builds on previous work conducted as part of NASA’s Unmanned Aircraft Systems (UAS) Integration into the National Airspace System (NAS) project. ACAS Xu represents the next-generation successor to the Traffic Alert and Collision Avoidance System (TCAS II), wherein the Xu variant is intended for UAS applications. Whereas TCAS II exclusively issues RAs in the vertical dimension, a major distinction between ACAS Xu and previous collision avoidance (CA) systems is the introduction of horizontal and “blended” RAs (i.e., RAs with both horizontal and vertical components). This present work was conducted as an engineering analysis involving two parts. In Part 1, a two-by-two, within-subjects study was performed that manipulated how RAs were presented to a pilot situated at a UAS ground control station. Five participants experienced four experimental trials in which text and aural alerting characteristics were manipulated. In Part 2, another five participants experienced four trials in which the levels of automation were manipulated with regard to the CA and return-to-course (RTC) tasks. The results for Part 1 found no effect of display or alerting configuration on pilot performance. However, it was discovered that pilot response time to RAs greatly depended on the RA type. In particular, pilots were quicker to respond to vertical RAs (M = 4.52 seconds) than horizontal (M = 7.42 seconds) and blended (M = 9.68 seconds) RAs in which both dimensions were issued simultaneously. For Part 2 of the study, pilots found both auto-CA and auto-RTC functions equally useful. Most pilots were comfortable with the automation, however responses were mixed. Three of five participants indicated high levels of comfort with the auto-CA function, while two rated their comfort as low. Pilots’ comfort for the auto-RTC functionality was slightly higher: four out of five pilots gave high ratings, while one pilot gave a low rating. Overall, pilots ordinally ranked their preference for automated functions as auto-CA together with auto-RTC (when an aural alert announces a change between CA and RTC states), auto-CA, and auto-CA and RTC (without the aural state-change announcement). Recommendations for improving the display of automation are also discussed.
Mounting evidence suggests that radiation-induced damage to the hippocampus plays a role in neurocognitive decline for patients receiving whole-brain radiotherapy (WBRT). Hippocampal avoidance whole-brain radiotherapy (HA-WBRT) has been proposed to reduce the putative neurocognitive deficits by limiting the dose to the hippocampus. However, urgency of palliation for patients as well as the complexities of the treatment planning may be barriers to protocol enrollment to accumulate further clinical evidence. This warrants expedited quality planning of HA-WBRT. Pinnacle{sup 3} Automatic treatment planning was designed to increase planning efficiency while maintaining or improving plan quality and consistency. The aim of the present study is to evaluate the performance of the Pinnacle{sup 3} Auto-Planning on HA-WBRT treatment planning. Ten patients previously treated for brain metastases were selected. Hippocampal volumes were contoured on T1 magnetic resonance (MR) images, and planning target volumes (PTVs) were generated based on RTOG0933. The following 2 types of plans were generated by Pinnacle{sup 3} Auto-Planning: the one with 2 coplanar volumetric modulated arc therapy (VMAT) arcs and the other with 9-field noncoplanar intensity-modulated radiation therapy (IMRT). D{sub 2%} and D{sub 98%} of PTV were used to calculate homogeneity index (HI). HI and Paddick Conformity index (CI) of PTV as well as D{sub 100%} and D{sub max} of the hippocampus were used to evaluate the plan quality. All the auto-plans met the dose coverage and constraint objectives based on RTOG0933. The auto-plans eliminated the necessity of generating pseudostructures by the planners, and it required little manual intervention which expedited the planning process. IMRT quality assurance (QA) results also suggest that all the auto-plans are practically acceptable on delivery. Pinnacle{sup 3} Auto-Planning generates acceptable plans by RTOG0933 criteria without time-consuming planning process. The expedited quality planning achieved by Auto-Planning (AP) may facilitate protocol enrollment of patients to further investigate the hippocampal-sparing effect and be used to ensure timely start of palliative treatment in future clinical practice.
This study aimed to design automated volumetric-modulated arc therapy (VMAT) plans in Pinnacle auto-planning and compare it with manual plans for patients with lower thoracic esophageal cancer (EC). Thirty patients with lower thoracic EC were randomly selected for replanning VMAT plans using auto-planning in Pinnacle treatment planning system (TPS) version 9.10. Historical plans of these patients were then compared. Dose-volume histogram (DVH) statistics, dose uniformity, and dose homogeneity were analyzed to evaluate treatment plans. Auto-planning was superior in terms of conformity index (CI) and homogeneity index (HI) for planning target volume (PTV), significantly improving 8.2% (p = 0.013) and 25% (p = 0.007) compared with manual planning, respectively, and decreasing dose of heart and liver irradiated by 20 to 40 Gy and 5 to 30 Gy, respectively (p max ) of spinal cord by 6.9 Gy compared with manual planning (p = 0.000). Additionally, manual planning showed the significantly lower low-dose volume (V{sub 5}) for the lung (p = 0.005). For auto-planning, the V{sub 5} of the lung was significantly associated with the relative volume index (the volume ratio of PTV to the lung), and the correlation coefficient (R) and p-value were 0.994 and 0.000. Pinnacle auto-planning achieved superior target conformity and homogeneity and similar target coverage compared with historical manual planning. Most of organs at risk (OARs) sparing was significantly improved by auto-planning except for the V{sub 5} of the lung, and the low dose distribution was highly associated with PTV volume and lung volume in auto-planning.
Recently, the Lyman-α absorption observed in the spectra of high-redshift quasars has been used as a tracer of large-scale structure by means of the three-dimensional Lyman-α forest auto-correlation function at redshift z≃ 2.3, but the need to fit the quasar continuum in every absorption spectrum introduces a broadband distortion that is difficult to correct and causes a systematic error for measuring any broadband properties. Here, we describe a k-space model for this broadband distortion based on a multiplicative correction to the power spectrum of the transmitted flux fraction that suppresses power on scales corresponding to the typical length of a Lyman-α forest spectrum. In implementing the distortion model in fits for the baryon acoustic oscillation (BAO) peak position in the Lyman-α forest auto-correlation, we find that the fitting method recovers the input values of the linear bias parameter b F and the redshift-space distortion parameter β F for mock data sets with a systematic error of less than 0.5%. Applied to the auto-correlation measured for BOSS Data Release 11, our method improves on the previous treatment of broadband distortions in BAO fitting by providing a better fit to the data using fewer parameters and reducing the statistical errors on βF and the combination b F (1+β F ) by more than a factor of seven. The measured values at redshift z=2.3 are βF=1.39 +0.11 +0.24 +0.38 -0.10 -0.19 -0.28 and bF(1+βF)=-0.374 +0.007 +0.013 +0.020 -0.007 -0.014 -0.022 (1σ, 2σ and 3σ statistical errors). Our fitting software and the input files needed to reproduce our main results are publicly available.