Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ALARM SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Method for Determining the Sensitivity of a Physical Security System.

Modern systems, such as physical security systems, are often designed to involve complex interactions of technological and human elements. Evaluation of the performance of these systems often overlooks the human element. A method is proposed here to expand the concept of sensitivity—as denoted by d’—from signal detection theory (Green & Swets 1966; Macmillan & Creelman 2005), which came out of the field of psychophysics, to cover not only human threat detection but also other human functions plus the performance of technical systems in a physical security system, thereby including humans in the overall evaluation of system performance. New in this method is the idea that probabilities of hits (accurate identification of threats) and false alarms (saying “threat” when there is not one), which are used to calculate d’ of the system, can be applied to technologies and, furthermore, to different functions in the system beyond simple yes-no threat detection. At the most succinct level, the method returns a single number that represents the effectiveness of a physical security system; specifically, the balance between the handling of actual threats and the distraction of false alarms. The method can be automated, and the constituent parts revealed, such that given an interaction graph that indicates the functional associations of system elements and the individual probabilities of hits and false alarms for those elements, it will return the d’ of the entire system as well as d’ values for individual parts. The method can also return a measure of the response bias* of the system. One finding of this work is that the d’ for a physical security system can be relatively poor in spite of having excellent d’s for each of its individual functional elements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Rocket Engine Health Management: Early Definition of Critical Flight Measurements

The NASA led Space Launch Initiative (SLI) program has established key requirements related to safety, reliability, launch availability and operations cost to be met by the next generation of reusable launch vehicles. Key to meeting these requirements will be an integrated vehicle health management ( M) system that includes sensors, harnesses, software, memory, and processors. Such a system must be integrated across all the vehicle subsystems and meet component, subsystem, and system requirements relative to fault detection, fault isolation, and false alarm rate. The purpose of this activity is to evolve techniques for defining critical flight engine system measurements-early within the definition of an engine health management system (EHMS). Two approaches, performance-based and failure mode-based, are integrated to provide a proposed set of measurements to be collected. This integrated approach is applied to MSFC s MC-1 engine. Early identification of measurements supports early identification of candidate sensor systems whose design and impacts to the engine components must be considered in engine design.

Christenson, Rick L.↗

Operational Focused Data Analytics for Optimizing Radiation Portal Monitor-Based Nuclear Smuggling Detection Systems at Global Ports of Entry

The National Nuclear Security Administration’s Office of Nuclear Smuggling Detection and Deterrence has deployed a fleet of radiation portal monitors (RPMs) across the world at global ports of entry including seaports, airports, and land border crossings. These RPMs are integrated into radiation detection systems (RDS) that also include fixed cameras, optical character recognition (OCR) systems, primary scanning systems (e.g., X-ray or gamma-ray), and secondary scanning systems (e.g., spectroscopic radiation portal monitors, portable radiation detection systems). The data from these sensing technologies is collected at the Central Alarm Station (CAS) where servers and computers reside to control and operate the system. Operators utilize the data collected by the CAS and declared cargo information to make decisions on how to respond to an alarm.This work explores the use of CAS-located data, looking at both the sensor data streams and operator inputs, to perform analysis which supports customs and border protection agencies to improve training capability and operational effectiveness. We focus on analyzing site level effectiveness and behavior by rolling up CAS-located data collected from individual occurrences. To-date, more than 15 sites (e.g., seaports, airports, border crossings) have been analyzed in this manner with the goal of understanding system operations to verify effectiveness and recommend potential improvements. This work first aims to provide background information on relevant CAS-located data sources and our current operational system analytics process including example results. After summarizing our current analytic techniques, we discuss how the future data analytics systems can provide key benefits to improving operational performance while minimizing the burden these detection systems place on operators.

Kuhn, Michael↗

Smart connected worker edge platform for smart manufacturing: Part 2—Implementation and on‐site deployment case study

Abstract In this paper, we describe specific deployments of the Smart Connected Worker (SCW) Edge Platform for Smart Manufacturing through implementation of four instructive real‐world use cases that illustrate the role of people in a Smart Manufacturing paradigm through which affordable, scalable, accessible, and portable (ASAP) information technology (IT) acquires and contextualizes data into information for transmission to operation technologies (OT). For case one, the platform captures the relationships between energy consumption and human workflows for improved energy productivity while workers interact with machines during semiconductor manufacturing. The platform utilizes human cognition to identify anomalous machine behavior for root cause analysis of system faults via neural network (NN) that recognize alarm postures of workers with cameras. For case two, a smart assembly line is demonstrated for state monitoring and fault detection. Machine learning (ML) models are used to recognize system states and identify fault scenarios with human intervention. For case three, the platform monitors human–machine interactions to classify manufacturing machine states for proper operations and energy productivity. Internal energy states of individual or collections of manufacturing equipment are determined via NN based algorithms that disaggregate signals associated with smart metering typically deployed at manufacturing facilities. These methods predict the real time energy profile of each machine from the total energy profile of a manufacturing site. For case four, a software defined sensor system built with scientific workflow engines is demonstrated for contextualizing data from laser surface refraction for characterization, and diagnostics in the processing of additively manufactured titanium alloy.

Donovan, Richard P.↗

Innovative PLC Design for Optimized Potable Water Managment

My project here at Idaho National Laboratory (INL) was to work on Potable Water PLC Design (Programmable Logic Controllers). I was tasked in making a new panel design for the PLC system that will be moved from TRA BLDG 696 to TRA BLDG 608. This design needed to be updated since the old PLC system being about 20 years old. The manufacturer of the MicroLogix 1200 life expectancy showed it to be 10-20 years, and the system was discontinued in 2017. The new system we implemented was called CompactLogix Controller 5380, along with a new 24 VDC/10 Amp Power Supply. I made a design using Microsoft Visio, with the new material. But we needed to add it onto an Aluminum Panel that the system will be mounted onto, we need Unistrut’s for the aluminum panel to be mounted to. Some of the material we will still be using, like the R1 Alarm Relay, will be moving with the PLC system. The rest of the material will be new supplies that need to be updated systems, which the site is waiting for to complete the PLC system.

47 - OTHER INSTRUMENTATION↗

Microprocessor-based multichannel flutter monitor using dynamic strain gage signals

Two microprocessor-based multichannel monitors for monitoring strain gage signals during aerodynamic instability (flutter) testing in production type turbojet engines were described. One system monitors strain gage signals in the time domain and gives an output indication whenever the signal amplitude of any gage exceeds a pre-set alarm or abort level for that particular gage. The second system monitors the strain gage signals in the frequency domain and therefore is able to use both the amplitude and frequency information. Thus, an alarm signal is given whenever the spectral content of the strain gage signal exceeds, at any point, its corresponding amplitude vs. frequency limit profiles. Each system design is described with details on design trade-offs, hardware, software, and operating experience.

Smalley, R. R.↗

Microprocessor-based multichannel flutter monitor using dynamic strain gage signals

Two microprocessor-based multichannel monitors are described for monitoring strain gage signals during aerodynamic instability (flutter) testing in production type turbojet engines. One system monitors strain gage signals in the time domain and gives an output indication whenever the signal amplitude of any gage exceeds a pre-set alarm or abort level for that particular gage. The second system monitors the strain gage signals in the frequency domain and therefore is able to use both the amplitude and frequency information. Thus, an alarm signal is given whenever the spectral content of the strain gage signal exceeds, at any point, its corresponding amplitude vs frequency limit profile. Each system design is described with details on design trade-offs, hardware, software, and operating experience.

Smalley, R. R.↗

Pneumatic load compensating or controlling system

A pneumatic load compensating or controlling system for restraining a load with a predetermined force or applying a predetermined force to the load is described; it includes a source of pressurized air, a one-way pneumatic actuator operatively connected to a load, and a fluid conduit fluidically connecting the actuator with the source of pressurized air. The actuator is of the piston and cylinder type, and the end of the fluid conduit is connected to the upper or lower portion of the cylinder whereby the actuator alternatively and selectively restrains the load with a predetermined force or apply a predetermined force to the load. Pressure regulators are included within the system for variably selectively adjusting the pressurized fluid to predetermined values as desired or required; a pressure amplifier is included within the system for multiplying the pressurized values so as to achieve greater load forces. An accumulator is incorporated within the system as a failsafe operating mechanism, and visual and aural alarm devices, operatively associated with pressure detecting apparatus, readily indicate the proper or improper functioning of the system.

Rogers, J. R.↗

Apparatus for detecting at least one predetermined condition and providing an informational signal in response thereto in a medication infusion system

A medication infusion system provides redundant safety and includes condition detecting and informational alarm signal generating apparatus for indicating if (1) a fluid leak occurs in different portions of the system; (2) a programmable input from a patient or physician would result in exceeding a safe dosage limit; (3) the reservoir containing medication has been filled; (4) the intended medication pumping does not correlate with the pumping actually effected; (5) battery voltage is low; (6) the medication reserve is low; and (7) the system has been switched off. The apparatus may provide subcutaneous electrical, thermal, or audible stimulation to the patient and also provides a signal which a physician may monitor. The stimulation may be coded to separately identify each above-listed deviation in nominal system performance. In addition, the number of medication requests are correlated with actual medication dispensing to assure proper operation. An identification scheme is provided which matches the patient with his or her corresponding medication.

Fischell, Robert E.↗

Sensory redundancy management: The development of a design methodology for determining threshold values through a statistical analysis of sensor output data

Sensor redundancy management (SRM) requires a system which will detect failures and reconstruct avionics accordingly. A probability density function to determine false alarm rates, using an algorithmic approach was generated. Microcomputer software was developed which will print out tables of values for the cummulative probability of being in the domain of failure; system reliability; and false alarm probability, given a signal is in the domain of failure. The microcomputer software was applied to the sensor output data for various AFT1 F-16 flights and sensor parameters. Practical recommendations for further research were made.

Scalzo, F.↗

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring↗

A slope reversal video processor having amplitude and pulse width discrimination.

A timing discriminator whose output is relatively insensitive to input pulse width and amplitude is described. The video-handling technique is known as slope reversal processing and is based on tapped delay line estimation methods. The concept, design, breadboard construction, and preliminary laboratory test results are reviewed. The processor system features (1) a peak input voltage dynamic range of 80x starting at 100 microvolts; (2) a four stage preamplifier/line-driver having a voltage gain of 2400x; (3) a tapped delay-line estimator implemented for slope reversal triggering by differential comparison; (4) a nominal plus or minus 2.5 nsec shift of the output trigger leading edge over the entire input voltage range, (5) up to 7 dB discrimination against pulse widths less than 35 nsec; and (6) up to one order of magnitude reduction in the false alarm rate compared to a constant fraction system.

Hoge, F. E.↗

Development of nickel hydrogen battery expert system

The Hubble Telescope Battery Testbed employs the nickel-cadmium battery expert system (NICBES-2) which supports the evaluation of performances of Hubble Telescope spacecraft batteries and provides alarm diagnosis and action advice. NICBES-2 also provides a reasoning system along with a battery domain knowledge base to achieve this battery health management function. An effort to modify NICBES-2 to accommodate nickel-hydrogen battery environment in testbed is described.

Shiva, Sajjan G.↗

Aircraft Engine Sensor/Actuator/Component Fault Diagnosis Using a Bank of Kalman Filters

In this report, a fault detection and isolation (FDI) system which utilizes a bank of Kalman filters is developed for aircraft engine sensor and actuator FDI in conjunction with the detection of component faults. This FDI approach uses multiple Kalman filters, each of which is designed based on a specific hypothesis for detecting a specific sensor or actuator fault. In the event that a fault does occur, all filters except the one using the correct hypothesis will produce large estimation errors, from which a specific fault is isolated. In the meantime, a set of parameters that indicate engine component performance is estimated for the detection of abrupt degradation. The performance of the FDI system is evaluated against a nonlinear engine simulation for various engine faults at cruise operating conditions. In order to mimic the real engine environment, the nonlinear simulation is executed not only at the nominal, or healthy, condition but also at aged conditions. When the FDI system designed at the healthy condition is applied to an aged engine, the effectiveness of the FDI system is impacted by the mismatch in the engine health condition. Depending on its severity, this mismatch can cause the FDI system to generate incorrect diagnostic results, such as false alarms and missed detections. To partially recover the nominal performance, two approaches, which incorporate information regarding the engine s aging condition in the FDI system, will be discussed and evaluated. The results indicate that the proposed FDI system is promising for reliable diagnostics of aircraft engines.

Kobayashi, Takahisa↗

Executive Summary: Prototype Design, Analysis, and Results for a Liquid Radiological Waste Control Room

Under the United States Department of Energy Light Water Sustainability Program (LWRS), Idaho National Laboratory (INL) is collaborating with Palo Verde Generating Station (PVGS) to support human factors engineering efforts in the modernization of PVNGS’ radiological waste system (LRS) control room. The studies proposed and/or conducted by INL are designed to address the inconsistency between different human factors standards, guidance, and conventions. Guidance such as NUREG-0700 leave much of the information open to interpretation. INL will identify whether maintaining a design that is consistent with population stereotypes actually enhances performance, or whether there are alternative designs that yield performance that is better than the designs that maintain those stereotypes. The overall design concept for the LRS workstation includes system overview displays for the Evaporator system and the Boric Acid Concentrator system. A third display contains overview information for the rest of the LRS. The forth display contains alarm information. Each display will be presented on one of four monitors in the control room. The system overview displays contain embedded controls for valves and pumps, mini-trends, and micro-trends. The mini-trends present data for the controllers and contain alarm set point information as well as trending. All other relevant system parameters are shown on micro-trends. The semi-dull screen approach utilized present dynamic data in green, active components are white (gray when closed or off). The product stream flow paths are indicated by different colors. Alarm states are presented in saturated red and selected components are indicated by bright blue. In addition to the micro task study described below, the INL researchers also conducted an evaluation of the semi-dull screen approach as well as an ergonomic evaluation of the suggested upgrades in the local control room. A detailed report of all INL’s activities related to the modernization of the LRS conducted between October 2016 and September 2017 are found in these two reports; • INL-EXT-17-43226, Prototype Design, Analysis, and Results for a Liquid Radiological Waste Control Room, and • INL-EXT-17-43250, Evaluation of Control Room Interface Designs to Support Modernization in Nuclear Power Plants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving accuracy and reliability of 186-keV measurements for unattended enrichment monitoring

Improving the quality of safeguards measurements at Gas Centrifuge Enrichment Plants (GCEPs), whilst reducing the inspection effort, is an important objective given the number of existing and new plants that need to be safeguarded. A useful tool in many safeguards approaches is the on-line monitoring of enrichment in process pipes. One aspect of this measurement is a simple, reliable and precise passive measurement of the 186-keV line from {sup 235}U. (The other information required is the amount of gas in the pipe. This can be obtained by transmission measurements or pressure measurements). In this paper we describe our research efforts towards such a passive measurement system. The system includes redundant measurements of the 186-keV line from the gas and separately from the wall deposits. The design also includes measures to reduce the effect of the potentially important background. Such an approach would practically eliminate false alarms and can maintain the operation of the system even with a hardware malfunction in one of the channels. The work involves Monte Carlo modeling and the construction of a proof-of-principle prototype. We will carry out experimental tests with UF{sub 6} gas in pipes with and without deposits in order to demonstrate the deposit correction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Earthquake warning system for infrastructures : a scoping analysis.

This report provides the results of a scoping study evaluating the potential risk reduction value of a hypothetical, earthquake early-warning system. The study was based on an analysis of the actions that could be taken to reduce risks to population and infrastructures, how much time would be required to take each action and the potential consequences of false alarms given the nature of the action. The results of the scoping analysis indicate that risks could be reduced through improving existing event notification systems and individual responses to the notification; and production and utilization of more detailed risk maps for local planning. Detailed maps and training programs, based on existing knowledge of geologic conditions and processes, would reduce uncertainty in the consequence portion of the risk analysis. Uncertainties in the timing, magnitude and location of earthquakes and the potential impacts of false alarms will present major challenges to the value of an early-warning system.

99 GENERAL AND MISCELLANEOUS↗